GE Zoneline HP PTAC A3B688DAALW1 WIRING DIAGRAM? Found a 6" L white wire with 1/4"F stake-ons loose from center terminal of Compressor capacitor 20/5uf going into the back wiring compartment. Not sure where it came loose from. There is a black multi stake-on terminal block up inside behind the capacitors. Attached it there to a unused spade but now fan does not run the indoor fan when in heat mode (compressor or elect. heat). Before the fan and electric heat worked but compressor just buzzed try


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

GE Zoneline HP PTAC A3B688DAALW1 WIRING DIAGRAM? Found a 6" L white wire with 1/4"F stake-ons loose from center terminal of Compressor capacitor 20/5uf going into the back wiring compartment. Not sure where it came loose from. There is a black multi stake-on terminal block up inside behind the capacitors. Attached it there to a unused spade but now fan does not run the indoor fan when in heat mode (compressor or elect. heat). Before the fan and electric heat worked but compressor just buzzed try


... GE Zoneline AZ55H07D Air Conditioner

We installed a Honeywell RTH230B thermostat on a Trane XE60 Air Handeler this winter. When we put the system on heat it works fine. However, when we put the system on auto for cool the compressor fan comes on but not the air handeler fan. On the air handeler the terminal strip from left to right is R W Y G B/C. The red wire on the R terminal comes from the contactor on the compressor unit. The other wire from the compressor unit is connected to a gray wire that goes to the thermostat. The W


I ran into this before and had to call Honeywell for help in the wiring...it seems the wiring was not done to standard, and they were able to help me get it straight in about 10 minutes and at no charge. ... Air Conditioners

On outside compressor for whole house AC: Critters ate wires. Have Blk & Red power in from breaker. 24vac switched from thermostat. 1 contactor with 24vac coil(original). 1 Capacitor w/ 3 terms labeled: C, fan, herm. compressor w/ 3 wires: #10 yel & blk, #14 red. fan w/ 3 # 18 wires: Blk, Orn, Blu. I need wiring. Here is what I think: All blacks connect together. Red power wire connects to contactor in. Fan orn & Compressor Yel go to contactor out. Capacitor is the problem. "C" marked terminal g


There should be a wiring diagram on the back of the access panel. If you can't read it, check online for model wiring diagram. Don't guess, you may cause more expensive damage. ... Air Conditioners

Lennox Conservator III G16, Furnace, Burners stay lite for 90 seconds; no blower; but exhaust fan runs continuous. If I use a jumper from the white heat wire (including white heat wire) to the green blower wire terminal (removed the green thermostat wire) the blower fan runs (non-stop) & igniter & burners restart every 10 mins. when I remove the jumper (& wire to specs from the thermostat to the furnace) igniter & burners kick on for 90 seconds then nothing on the unit works except the exhaust f


... Air Conditioners

Small orange wire from switch to capasitor burnt to red wire to compressor now outside fan won't run, can move brown wire from green terminal to orange wire terminal on cap and fan runs low speed


You need to replace the cap, there is no low speed, the capacitor is bad ... Ruud Central System Air Conditioner

Wiring compressor Replaced defective fan motor on my a/c unit. Old motor had three wires: black, yellow, brown. New generic motor has black, white, brown, brown w/white stripe. This new motor came with a new two terminal capacitor. Old cap. had three terminals. The black and white wires from motor connect across the line voltage and the other two wires connect across the capacitor. After install and trying to run the unit, found that compressor turns on for about two seconds and shuts down, but


The two terminal cap is only for the new fan motor. Connect the compressor wire back where you found it, on the 3 terminal cap. It's the terminal marked, "herm". The "common" terminal on the 3 terminal cap must still be connected to one side of the ... Carrier 38CKC036 Air Conditioner

LENNOX HS26-048-3P Installing Honeywell wifi thermostat. C terminal on control board was connected to X on the old thermostat. The X terminal wire on the old thermostat is connected to the C terminal on the control board. I used this wire to connect to the thermostat C terminal and now the compressor fails to come on. The slow flashing lights indicate the thermostat is asking for cool and the fan comes on, compressor does not come on.


... Air Conditioners

Ihave a Day & Night Furnace M/N:58GS050-3 Series 301 S/N:Z33A65482. My problem is with no wiring whatsoever landed @ terminal strip fan runs @ high speed constantly.With stat wired up & a call for heat I get no spark,just fan(fan switch -auto). 24vac is present into circuit board from transformer, but drops out to 15.xx @ R & C.If I apply 24v directly to R along w/other wiring,fan stops,but after ignition main burners light,fan never runs.


... Carrier Air Conditioners

Reset button for Ruud Achiever 14 heat pump/AC compressor? My Ac/heat thermostat was blowing fan on and would not turn off. I switched it off at the circuit box, and bought a new thermostat RTH221, wired it and it would not blow cool air when on cool nor warm air when on heat. Called the 800 number for Honeywell and tech said I had wired it correctly, to check outside and see if the compressor was running. It was not. This Ruud unit is only 8years old so I'm wondering if a reset button has


... Air Conditioners

I have to replace the start/run capacitor (97F9971 - Duel Capacitor/ 50, 7.5 370 VAC). I have marked the terminals before removing and purchased the new capacitor. The new capacitor has minor difference with the old one. The hermatic has 3 terminals, The Fan has two terminals The Compressor (C) has 4 terminals. Now in the old unit, two wires were connected to two opposite terminals on C, one in Herm and one in Fan. My question is: How will I know which terminal to connect in the new one


All the terminals are connected together so it won't matter which terminal you use, just as long as you have the Herm, Com, and Fan wires correct. Hope this helps! ... Air Conditioners

I have a Trane Heater/AC unit no heat pump with a thermostat model 802AS32DAA that has seven wires. I am going to a five wire heating/cooling thermostat. What do i do with the two extra wires? old thermostat red wire-RC slot (24 V from A/C) white wire-W1 (???) yellow wire-Y (A/C Compressor) green wire-G (A/C Fan) black wire-B (?????) Blue wire-Y2 (????) orange wire-W2 (24 V to Furnace new thermostat therminals G Rc Rh Y/O W/B Y1 Can you tell me what wires to connect to each


From Honeywell : "If your old thermostat had Six or more wires, the replacement you have is Wrong!" ... Air Conditioners

Have a duo therm penguin heat pump a/c when turning it on the compressor humms but no fan. the fan gets pretty hot upon the roof after 20 sec of operation. the main hot wire to the unit is pulling 18.5 amps when unit is turned on. fan spins freely! ??????


Check the cap for the fan. Will the fan start if you spin it when you hear the humming. Check the lock rotor amperage for the compressor to see if it is hung up. The cap if it is shared could knock out both the fan and comp so check both. ... Air Conditioners

I have a dometic heat pump a/c basement park model unit. The fan is not working. The compressor runs, but no air inside or out. I have power into the run cap. but not on the brown wire to the fan from the run cap. I also have no power to the fan high or low off of the relay board. Where do I go next to isolate?


... Dometic Air Conditioners

EMERSON FAN MOTOR WHICH HAS A BLK WIRE PURPLE WIRE AND A BROWN WIRE WENT DEAD. SO I BOUGHT A NEW FAN EMERSON CAME WITH 4 WIRES BLK ,WHITH, BR AND BRW AND BRW WITH WHITE STRIPE. I WIRED IT BLK TO THE CONTACTOR WHITE TO THE COMM THE YELLOW FROM COMPRESSOR TO THE HERM BRW TO THE FAN BRW WITH WHITE STRIPE TO THE COMM THERE IS A RED WIRE GOING FROM THE COM TO THE CONTACTOR WHEN I TURN THE AC UNIT THE COMPRESSOR COMES ON PUT FAN DOES NOT ?????


The two brown wires go to the fans capacitor. The capacitor should always be changed with the fan motor.\015\012\015\012It sounds like your unit has a dual capacitor. One side for the fan and the other for the compressor. All you will be ... Dometic Rooftop RV Air Conditioner

Haier hsu 18 heat pumps . I have 6 of them , all intermittently come up with e17. otherwise sometimes they will just blow fanned air ( compressor not running ) all day . The power source is fed to the indoor unit first, with the main power and data then fed along the same standard 4 core cable to the outdoor unit. I have fitted one of these units which had this problem to another site , and instead of wiring it as per the above way (as per instructions) I put the data cable seperate to the oth


... Haier Air Conditioners

IN DOOR FAN WILL BLOW BUT NOT THE COMPRESSOR - Fedders FPTHP15B208 Cooling Packaged Terminal Air Conditioner w/ Heat Pump & 14,000/14,000 Cooling B...


What I would do is see if maybe a terminal on the compressor is burnt. Easy fix. Looked up the model number to no avail. If you have separate capacitors for fan and compressor I would look for a swollen failed capacitor. Check and see if the compress ... Fedders FPTHP15B208 Cooling Packaged Terminal Air Conditioner w/ Heat Pump & 14,000/14,000 Cooling B...

Had a Goodman heating unit installed in Oct. 2009. Recently tried to turn ac on .but no action. Installer returned and hooked up some wiring which got fan working but no cold air. The outside compressor worked only when I manually closed the relay. What cculd be the problem.?


It sounds like the outside condenser wires are still not hooked up correctly or there is a problem with the 24v electrical inside the unit. Describing what you have, I'm just banking on the connections. Now, if you have a heat pump system, there will ... GE AJCQ08ACB Air Conditioner

Recently replaced blower wheel and blower wheel motor mounts,that problem was solved but now fan motor for the compressor runs non stop-wont shutoff except by breaker box.also changed thermostat at the same time.have i inadvertinly placed the wrong wire terminal in the wrong recepticle in either the blower motor or thermostat? If so,which one and where?How can it be fixed?The unit is a 1973 coleman evcon.


First question first, NO! this is a simple problem and a common one to fix, just change out the outside contactor coil, the contactor has a thin layer of silver on them to prevent them from arching and sticking together, over time this thin layer b ... Air Conditioners

RTH3100C thermostat Have 4 existing wires; Yellow(cooling),white Heating) green (Fan) and red (power) WWhat terminals to use at above stat?


The RTH3100 is a heat pump stat. Your wires indicate that you have a 1h/1c operation. This is the wrong stat for your application and will not work. ... Air Conditioners

I have a split system sanyo heat pump model # kmh0922. The evap. fan will not come on when called for in fan mode. When i put it to heat the indoor fan will also not come on. The compressor runs but the reversing valve seems to stay in the cooling mode. When it is put into cooling the indoor fan goes off after 15 seconds and will not come back on. (The condenser fan and compressor seem to act normal in cooling.) Any ideas as to what the problem could be? Thank you, Mike


Sounds like the blowers capacitor has gone bad ... Sanyo Air Conditioners

How do I wire a new condensor fan motor to the new capacitor? The old capacitor is longer and it has 3 terminals. the new capacitor is much smaller and oval. It has 2 terminals. the fan motor has 3 wires, black, brown, and purple. there is a red wire comming from the conductor and a yellow wire comming from somewhere else.


Before attempting any of these recommendations, First disconnect all the power sources and check your wiring diagrams on the motor and condensing unit.\015\012On the old capacitor if you look on the top near each of the three terminals. Are the ... Air Conditioners

Heating and air condition unit will not kick on when i try to turn the heat on in the morning. we have tried the auto fan and the on fan for both ac and heat...will only work for the ac. the breaker switch at the breaker box is the only solution we have found to get the unit to fire up and to start the heat for the unit...my brother has checked the wiring at the thermostate..mercury type..found no burned out wires...he changed the filter on the system...tried to clean all the contact points on


Hello , I can help you out here. First check the T-stat with all breakers on take the red t-stat wire and white t-stat wire and green t-stat wire , tie the 3 together and wait 5 minutes to see if anything starts up. If the heat starts running replace ... Air Conditioners

Air Conditioner compressor fan stops, Capacitor wired wrong?


Purple should be on "C".\015\012The fan motor may be destroyed now. Switch the wire and see if it keeps running or not. ... Air Conditioners

How to change 3 wire motor with 4 wire motor for outside ac unit fan motor?....old motor had blk wire going to a circuit board, also pur wire going to c terminal on cap, also brw wire going to f terminal on cap...... new motor , on the name plate , shows blk and wht wire going to line. also brw and brw/white stripe wires going to cap.... does the blk go to the same place as the old blk and the white does it go to the other line wire coming off the contactor? also which terminals do i attach t


You need this wire onto the "F"terminal- fan terminal as this is a 230 volt condenser fan motor all your doing is parrelling the cap ... Air Conditioners

Replaced a ge condensor fan 3 wire with new dayton the wires are different...old fan has a wire connectort mouted to it orange,black yellow, the new one 2brown 1 with white stripe, purple, black, i have new 2 connect compacitor and a 3 connect compacitor( herm, C, Fan) where do i hook new the fan wires, and where do i connect the compressor wires.


The new ge fan requires its own capacitor, the brown and the brown/white go direct to new fan capacitor. black to relay (leg one of power) purple to relay (leg two of power. the compressor will have a wire to the relay and the other to the herm termi ... Air Conditioners