I have a Carrier Weathermaker Infinity furnace model 58MVP100-F-1-20 with 3 zones and Carrier Comfort Zone II programable thermostat. I recently installed ageothermal heat pump system which includes a hot water coil in the furnace plennum. The heat pump is sized to meet loads except for the coldest days of winter - (below 0 F) - when the gas furnace is expected to kick in. My problem appears to be the Weathermaker's characteristics don't accommodate the low heat /slow response provided by


Answers :

Http://www.hvac-talk.com/vbb/archive/index.php?t-85094.html here is a site i found very useful
You can disconnect the wire attached to w2 on the new stat and that way the stat will be unable to turn on the furnace when you push it more than two degrees above the room temp. if you leave the wire connected to w2 then anytime the stats desired temp is set more than two degrees warmer than the house, the heat pump and the furnace are designed to come on together till the temp approaches two degrees of set point then the furnace shuts down and the pump maintains. this way the pump will do its thing till it gets cold. (below 40 degrees). when that happens you can go to the stat and switch to emergency heat. this will power up only the furnace as soon as there is a first stage call for heat. it will not wait to see what the pump is doing and go to heating with furnace right away. you simply switch back to normal heat setting when temps go back above 40 degrees. the furnace is actually wired to two terminals on the stat. w2 is backup heat terminal you disconnect and the x terminal or aux terminal is energized only when you are switched into emergency heat.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a Carrier Weathermaker Infinity furnace model 58MVP100-F-1-20 with 3 zones and Carrier Comfort Zone II programable thermostat. I recently installed ageothermal heat pump system which includes a hot water coil in the furnace plennum. The heat pump is sized to meet loads except for the coldest days of winter - (below 0 F) - when the gas furnace is expected to kick in. My problem appears to be the Weathermaker's characteristics don't accommodate the low heat /slow response provided by


Http://www.hvac-talk.com/vbb/archive/index.php?t-85094.html here is a site i found very useful ... Carrier Air Conditioners

We have a Carrier Heat pump. Today the heat pump and (gas) furnace turned off completely and the thermostat is blank. We've checked the fuses and they seem to be fine and everything else is working well. It's forecast to be in the high 30's over the next few days so having the heat pump/AC working is a necessity. The installer can't get here for 2 more days ( he doesn't work weekends). I don't have any idea what to do. Help - help!


Is the thermostat battery powered or powered by the transformer. If it is powered by the transformer then the transformer may have gone out. Turn the thermostat to off. Use a multimeter to check for 24 vac between R and G on the thermostat. If you do ... Air Conditioners

Dear FixYa Experts, I am a new home owner. I have a Kenmore Air Conditioner (heat pump?, see more details below) with Lincoln Gas Furnace. According to the former owner, the heating system will start heat pump first when the temperature is above -15C and then turn on the gas furnace when the temperature drops below -15C. Recently, when I turn on the heating system, only the gas furnace was always running but not the Kenmore air conditioner. And our average temperature was always above +5C for


... Kenmore Air Conditioners

I am trouble shooting a Bryant Hi-bred system that uses an air cooled heat pump with high efficiency gas furnace for backup and low ambient operation. How does the system decide whether to use the air cooled heat pump or the gas fired high efficiency furnace. It appears to be outdoor air temperature related, but I can't find the setpoint for it. The main zone Bryant thermostat appears to control the system, but it doesn't always bring the backup heat if the heat pump doesn't function.


If you are using honeywell vision pro 8000 t-stat you need an outdoor sensor program on t-stat would have to look up ... Bryant Air Conditioners

I have a Kewanee model#1736 hot water boiler furnance which is gas fired.I had to change the heat pump and the heat pump switch.The heat system is wired through a Webster Heating Contol unit which has three settings,Run,Auto,and Off.Normally when the heat control unit is in the Auto position the furnace and heat pump will start and run automatically until it reaches the desired thermostat temp. Then both the pump and the furnace would shut down at the same time until the thermostat falls below t


The thermostat turns the Boiler and the Heat Pump on simultaneously???....That doesn't sound right...normally the Thermostat brings on the heat pump first and if the temp continues to fall (Its Cold out) then the Boiler would kick in about 2 degrees ... Air Conditioners

I have an amana dual fuel heat pump with LP gas furnace. the furnace will not light. the ignitor heats up, acts like it's not getting LP to the burner and i don't get 24 volts to the pressure switch just above the gas valve, or to the gas valve itself. i cut the power to the unit, removed pintle to the gas valve to ck for gas to the valve and it's o.k.,. what do i need to check next, i don't know how to get codes out of self diagnostic system and don't know if these codes would effect the furnac


... Amana Air Conditioners

Carrier 58rav gas furnace won't stay lit. Vent assist fan comes on ,burners ignite but just before the main blower comes on the flames go out. then the fan runs for 30 secs then the process starts over again. Usually the 3rd time it stays lit and actually heats the house. I have changed the flame sensor and if i unplug the power for 10 min. it usually works OK for a few days and then starts doing it again.


Hello my name is Heath it will be my pleasure to assist you. If you replaced the flame sensor I would check the vent pressure switch check the hoses and the niplles that the hoses are connected to to be sure they are clear of aany dirt or rust. If yo ... Air Conditioners

Approx 2 years old. quit working during recent rain storm. have a backup furnace that kicks in when temps go below 35 degrees. new carrier thermostat (1yr old). furnace fan comes on blowing cold air, but heat pump does not come on. can go to e-heating and furnace works fine. no fuses on heat pump, no reset button and circuit breaker is fine. believe this is electrical, not mechanical. thanks


It sounds like the contactor is not pulling in . corrision maybe even a bug could prevent it from pulling. ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

Heat pump and gas furnace running at the same time.


An explanation....\015\012\015\012When in the heating mode, all heat pumps are dependent upon the outdoor conditions to remove heat energy from the environment and turn it into useful heat for your dwelling. \015\012\015\012 ... Air Conditioners

Hello, I have a Heater/Furnace problem. I have a Carrier 58RAV095-16 Natural Gas Furnace. My furnace keeps restarting it's heating process. Upon turning the heater on, a small fan will engage and run for about 60 seconds, then the fan turns off and the gas engages and the igniter clicks and you hear the gas combust and the flames spew out onto the heating rods(?) and after a minute or so, the big fan will turn on and begin circulating air throughout the house. Sounds all good so far? Well


... Air Conditioners

I have a lennox 2 stage gas furnace and a lennox XP15 heat pump controlled through the Lennox 7000 touchscreen thermostat. I want to disable the heat pump due to excessive noise due to lower temperature at this time of year (+5C and lower) and have the furnace operate without the dual fuel feature. Can this be done at the thermostat or it requried to disable at the furnace? Any input would be helpful. Unable to locate 'installer manual' for thermostat.


... Air Conditioners

We had a new Carrier Weathermaker Infinity Gas Furnace installed in our home on 9-21-99.The Carrier people said the furnace was in good condition this past October.But prior to that as of April 2010 the furnace started sending up really cool air. Was told by the Carrier serviceman that the Controlboard was running on high and low at the same time also found the Board fired.Then NO HEAT. Got a new Controlboard installed,that didn't work Still NO HEAT.Was told furnace needs a model Plug that was


... Air Conditioners

I have a gas furnace that was to have a 10acc air conditioner unit installed with it. Instead of the 10acc unit a 10hpr48 heat pump unit was installed, The house is 4 years old and the reversing valve has failed. The unit is not wired as a heat pump but as an ac unit with only three wires. A independent air conditioner repair company has said this installation is inproper.Is this unit installed to code and would lennox guarante a unit installed in this manner?


It should definitly be warrantied. their is nothing wrong with your set up however id have the contrator pull a new wire and go dual fuel withh outdoor sensor and get the full benifit of dual fuel. you should use the hp above 40 ... Air Conditioners

Carrier thermostat Hello, My Carrier electronic thermostat is connected to a heat pump.  It was set to the COOL position during a summer thunderstorm when the AC suddenly began running no matter what the SET temperature was.  It works normally when I change it to the AUTO position.  The HEAT and EHEAT positions work normally. I tried cutting power to the unit for 2 days, after which it worked normally even on COOL, but after a short power failure it resumed the problem of running the AC continuo


I hate to say it but Ive had trouble with Carrier's Tstats doing similar improper things. Unfortunatly the only repair is going to be replacement of the whole tstat. I recommend Honeywell's FocusPRO or VisionPRO tstat. Ive yet to have one fail and th ... Air Conditioners

I put a 3 ton RUDD 15 seer heat pump in my own home,R-410 A. Here is what it is doing. When I get the pressures near where the chart says,such as 150 357 on a 94 degree day I lose all my heat on the hot gas line and my split goes way down. As I remove freon and the pressures go down the hot gas line begins to get hot but then I get alot of bubbles in the sight glass. This thing is really driving me nuts do you have any advice for me. Also when I get the house down to say 73 degrees and it is 85


... Air Conditioners

Carrier 38YXA036320 My Carrier Model 38YXA036320 Heat Pump will not run. Fan and compressor will not start in heat or cool modes. When I select cool, I can stand next to the unit and I hear things being energized but nothing happens except a humming sound.


... Air Conditioners

First, my thermostat wouldn't shut off either my heat pump or my furnace (it runs both). Thought it was an issue with the thermostat...got a new one. Worked like a charm for 1 day. Now, there is a clicking noise coming from the heat pump - it did it at first when trying to turn it on....now, when it's warmer, it will turn on, then start to do it. Doesn't seem to be putting out hot air now. Any ideas? The thermostat came with a new box that sits inside the ceiling and it's been replaced, bu


Sounds like your unit may be tripping on a pressure switch due to low refrigerant or a dirty outdoor coil. You may be able to look through the cover with a flash light to see if the inside of the outdoor coil is stopped up. Otherwise, you will have ... Dometic Rooftop RV Air Conditioner

I hae a electric heat pump and gas furnace, when utilizing the heat pump i get chattering from a relay, i have replaced this relay with a new one but continue to get chatter any ideas


Chatter on a relay can mean a few things but since you have just tried to replace it, i wouls check the voltage at the relay,,,,\015\012chatter is caused by i mproper voltage at the relay, coil, ... Air Conditioners

KW capacity on model # FE402, Carrier furnace and heat pump 25HNB6


... Air Conditioners

Wiring diagram for low voltage heat pump to gas furnace to stat


... Goodman Air Conditioners

I have a Carrier Infinity 96 gas furnace with no heat


That means that the furnace is throwing a code to trouble shoot whats wrong. Most of the time, furnaces will have a code list on the inside of the door cover to explain what each code means, some of them don't. Its hard to say what it could be withou ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

Have a York Stellar 2000 model E1CS024A, serial MAWM027260. Replaced electric furnace last year with Goodman Gas Furnace. Installer disconnected old York thermostat T874R1145 and replaced it with a programmable Honeywell Focus PRO 6000. He also removed the York interface panel in the furnace room and simply connected W-W & BLK-BLK to the outside unit saying that it should work. Needless to say when it turned hot yesterday and I powered up the Heat Pump and requested cool on the thermostat nothi


... Air Conditioners

My Carrier brand gas furnace quits working, so I move the thermostat to 50 degrees, it clicks, then clicks at 70 degrees and starts working again, sometimes for one cycle or sometimes for a day or two. Then it quits again. I replaced the thermostat and it still does this, no change. It appears something in the furnace itself is causing the problem. Also, if I switch the power switch off and on, then the furnace starts working again temporarily.


Yes it is the relay that pulls in that turns the furnace on. Sometimes they get carbon build-up on the contacts. I guess the easiest way to describe how to locate the relay is to have someone operate the thermostat and you listen at the furnace for t ... Air Conditioners

Gmpn80 4 lp gas, strong smell of gas outside at vent discharge. 2 new heat xchangers, gas valve, burners, furnace works great except for above prob


The manifold pressures must be 11.5 in or mor up to 13 some places, see that its not beeran with nat gas orifices, if it has it must be pulled and clen heat exchangers ... Air Conditioners

I have a Rheem A/C Heat Pump split with gas backup. The gas unit is mounted in the air flow directly before the A/C HP coil. Should the gas unit be wired as stage two heat, or is it OK to wire it as just aux/EM heat? There is no other heating unit. What is the difference between stage two and aux? Please note that the aux gas heat cannot come on if the heat pump is running or it may hurt the heat pump due to the gas heat units location.


Stage 2 is okay as long as there is a fossil-fuel kit accessory wired in the field control wiring. EM heat would only allow gas furnace operation if the thermostat is set for EMER HT mode.......this is not ideal and not recommended. Dual-Fuel applic ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0908 seconds