My hotpoint eg900x fan oven has a problem. the fan oven no longer heats up, fan is working but no heat. oven works in normal mode


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

My hotpoint eg900x fan oven has a problem. the fan oven no longer heats up, fan is working but no heat. oven works in normal mode


... Air Conditioners

Intermittent heat I have a Carrier (Payne) unit (FA4ANF030) with intermittent heat output. The air works as does the fan when in heat mode, but usually no heat. Sometimes it will suddenly begin to put out heat normally and will function fine...until it doesn't. The thermostat was old, so I replaced it first. Seems to make no difference at all since it works exactly as before.


Check wiring of heater, it may have loosed connection or corroded connection. ... Air Conditioners

This is a heating and cooling through the wall heat pump. It works normally when heating is selected - the heat pump runs and both speeds of the fan blow warm air. But nothing runs when cooling is selected. In other words the unit works normally when "High Heat" or "Low Heat" is selected but nothing runs when "High Cool", "Low Cool" or "Fan Only" is selected. The position of the Fan Cycle Switch has no effect - behavior of the unit is the same in both positions of the Fan Cycle Switch.


You have a bad board or bad switch. I would say board. You can have service tech check this out. There is only so far you can go without knowledge of Controls ad electricity. Russ ... Air Conditioners

Friedrich YM18 230 volt heat pump. The unit has heated and cooled well for about 5 years. Just started heating mode recently and the unit no longer heats. Fan runs OK. Was able to get the heat strip to run for a few minutes (smelled the dust accumulated over the summer burning off). Now, no heating whatsoever. When in the "Money Saver" mode, nothing happens. Fan will not come on and unit will not heat. With "Money Saver" mode off, the fan runs.


... Friedrich Air Conditioners

Hi i recently purchased a used convair portable supacool 9 air conditioner the first time i switched it on it appeared to work ok but the next time i turned it on it is working on normal fan mode but when i turn it to air conditioner mode it is doing exactly the same as on normal fan mode the compressor does not appear to be working and is not making the extra noise that it was the first time i have tryed all the switchs including the thermostat but there is only a very simple to use set up any


... Convair Portable Air Conditioner

Amana PTAC Unit is not producing heat. Fan works fine. can not locate manual reset for heat although a label on the unit says there is one. I have an Amana pth153b35ae ptac unit that the heat will not come on. The compressor will run in the cooling mode but not in heat mode. I verified the switching valve is working and the capacitor seems to be fine as the compressor will run in cooling mode. The thermostats seem to be functional because relays can be heard clearly when changing temperature se


I know this is late but I had to add a solution to this problem since I had the exact same problem and was able to solve it. The probelm is not your control board. On these units, the heat pump compressor will not kick in unless the temperature you ... Amana PTH123B25AJ Heat Pump Air Conditioner

I have a Coleman Evcon gas furnace model# DGAT095ADA last year I replaced the T-O-D #60T82 - 313675 fan switch and works fine. This year the unit started fine, but slowly started taking longer & longer to heat up, then finally not heating up enough to trip fan switch. Manually tripping fan switch resulted in some warm air through system, but not enough to heat a house. Gas comes on and is blue what would be my next course of action ?


... Air Conditioners

I have a split system sanyo heat pump model # kmh0922. The evap. fan will not come on when called for in fan mode. When i put it to heat the indoor fan will also not come on. The compressor runs but the reversing valve seems to stay in the cooling mode. When it is put into cooling the indoor fan goes off after 15 seconds and will not come back on. (The condenser fan and compressor seem to act normal in cooling.) Any ideas as to what the problem could be? Thank you, Mike


Sounds like the blowers capacitor has gone bad ... Sanyo Air Conditioners

Sir, I have Neff double oven, abou 15 years old. Top oven heats but not to full capacity. Fan works and bottom grill and oven work. Rubber sealing strip around oven loose and needs replacing, which I can do. Would this solve poor heating in main oven or does it need a thermostat. Many thnaks for any help you can advise.


You won;t know for sure until you have replaced the oven seal. Try this first ... Air Conditioners

Pace Air 24HPEW-HEC Unit will not heat, though heat mode comes on, dehumidify and cool mode work, and fan works as advertised. Fault Code E4 presents at startup. Manual is off site. What is this code telling me?


If unit displays "e4"1? Check whether the winding resistance andoperation current of the compressor are normal.2?Check whether the high and low pressure is normalwhen the unit is running.3?Check (whether the ... Pace 12ACXWHEC Split System Air Conditioner

GE Zoneline HP PTAC A3B688DAALW1 WIRING DIAGRAM? Found a 6" L white wire with 1/4"F stake-ons loose from center terminal of Compressor capacitor 20/5uf going into the back wiring compartment. Not sure where it came loose from. There is a black multi stake-on terminal block up inside behind the capacitors. Attached it there to a unused spade but now fan does not run the indoor fan when in heat mode (compressor or elect. heat). Before the fan and electric heat worked but compressor just buzzed try


... GE Zoneline AZ55H07D Air Conditioner

I have an LG mini split ac / heat pump system ( LAN096 ) that is only 4 months old was working great in all ways until suddenly it quit heating. I am sure it happened quickly because I was nearby when very warm air changed to cool ( unheated ) and hasn't heated since. When I shut it down and restart it the indoor fan runs right away, which is not normal and the outdoor unit will run for a minute or so then shut down and stay off. The indoor fan will continue to spin as though it is set in a 'fan


... LG Air Conditioners

Hi, I have a wall mount midea split a/c model- MSG-36HR that will only heat. when put in cool mode it only blow's room temp air and the outdoor unit won't run. On heat mode it works normally. I have cycled power a couple of times, changed modes on the remote numerous times and just in case, changed the batteries in the remote. The unit is about 3 yrs old. Do you have any pointers. Cheers Tom


Most heat pumps are 'fail-safe to heat'. That is: the normal position of the valve which reverses the function is in the position which provides heat. The reversing valve must be powered to switch to the cooling position.Although the ... Midea Air Conditioners

Hi there I have an lg reverse cycle aircon model LWC122RH-2 and the heating seems to work fine on it at however when I try and put the cool mode on it desn't seem to get very cold and the cool light does not come on also the defrost light doesn't come on but the heat light and the fan light and timer lights all work and come on ...please help


... LG Heat cool Window Air Conditioner

On a comfort Aire Model A HMH 12as heat pump the condenser fan motor does not run on the heat mode. Unit operates normally in the cooling mode.


... Comfort-Aire HMH12AS-0 Air Conditioner

I have a AZ38H15DADM1 that works fine in heat mode and in AC mode it works great until it reaches the temp it thinks it should be, then it cuts off and never cuts back on without me physically turning the knob to the fan for a minute or so and then switching it back to AC. Any suggestions??


... GE Zoneline AZ38H12DAD Split System Air Conditioner

Fujitsu inverter ASTA24LCC aircon wont work on heat mode. Two flashes of red and green lights, followed by five flashes of red light and sequence continues with a pause between. Other modes, fan, cool etc work.


Check that the gas is not leaking, that would be the most likely cause. ... Fujitsu Air Conditioners

My oven isn't heating up. Te fan works and the grill and the light comes on but no heat for the oven


It turned out it was the circuit breaker. The burners worked but not the oven. ... Electrolux Air Conditioners

On a comfort Aire Model A HMH 12as heat pump the condenser fan motor does not run on the heat mode. Unit operates normally in the cooling mode.


... Comfort-Aire HMH12AS-0 Air Conditioner

Indoor Sanyo ductless split Model # KHS 2432 serial # 0012832, Works fan on and off functions and speeds. As soon as you set the remote to heating or cooling the unit beeps 5 times quickly and then the unit no longer responds to remote control. The blower will then run for 1 minute and then the the unit no longer will work. Power must be reset for blower operations to function again. Out door unit, has enough charge, Ambient temp 39 M#CH2432 S#0012424


... Sanyo Air Conditioners

HEAT PUMP I have an older Twin Temp heat pump. Last night it was working fine then it started making a buzzing noise it was still putting out heat but the noise would not stop. I'm guess it switched from heat pump mode to eletric heat? Is this normal for the loud buzz though? It did smoke up and smell burnt a little bit. I just thought what ever dust dirt was burning off the heating elements. Should I be worried?


It is not normal to have a loud buzz associated with the electric heat. Try turning the heat off and running the fan only to see if the buzz continues. The buzz could be coming from any number of sources including an electrical component, the blower ... Friedrich Air Conditioners

GSH130481CA condensor and ARUF48601ba fan coil. Server noise at intermittent times,in heat mode, usully in the middle of the night. Sounds as if from fan coil. Fan coil 50 ft from condensor. Fan operating normally with noise.


It may be your noticing the defrost cycle which can be noisy at times exspecially at nite when the unit will reverses it cycle temporarily ... Goodman Air Conditioners

I have a Rheem heat pump/air handler; it draws 2.9amps with only the fan running, 13amps when the heat pump is running and 38amps with the heat strips on. My question is why the unit draws that many amps when in heat pump mode? Isn't all of the work being done by the compressor outside?


You gave us some good clues, and figures to work with-- THANKS!!To answer your question: Your unit switches the one compressor, from cooling, to heating, by reversing some valves-- Same compressor-- just routing the refrigerant i ... Air Conditioners

Hello, I have two Yokohama Split type air conditioners that work fine for cooling, but when switched to heat they just blow air at room temperature and then after about 1 minute go into a standby mode indefinately. They work perfectly for cooling. All fans work perfectly and the compressor works perfectly for cooling. Thanks...


... Air Conditioners

I have 2.5TON heat pump that works fine in ac mode but does not heat only have heat in emergency .condenser fan does come on when heat is selected


The heat pump is either wired wrong on the low voltage side or the reversing valve is sticking. these need checked by a tech. if you are showing emergency heat then your thermostat is meant for a heat pump and that is also a good place for the tech ... Air Conditioners