Fedders central air unit starts and turns off. unit outside continues to run. Any ideas why?


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Fedders central air unit starts and turns off. unit outside continues to run. Any ideas why?


... Air Conditioners

I have a Goodman Heat Pump System. When I turn the thermostat up to call for heat the outside unit starts and the inside unit(Air Handler) starts. However the inside unit only runs for about one minute then shuts off while the outside unit continues to run normally? Any ideas?


... Goodman CLQ36AR49 Air Conditioner

Central air My central air unit continues to freeze up on the outside, as well as on the inside on top of the furnace. I had it checked and was told the return flow was the problem and to take the fliter off and make the return flow larger. This has done nothing!!! It continues to ice over. Any ideas? Please..it is sooooooo hot here right now. Have never had a problem with this and all of a sudden it is freezing up. Thank you


HEY_ 2 viable options suggests them self to me, 1 - low airflow ----------2 low on freon charge! Thank-you-very-much! ... Whirlwind FH-778 Air Conditioner

I have a goodman ar24-1 blower motor that will not start. I have changed the capacitor, checked the thermostat, spun the blower motor but still will not start. Outside unit runs but no blower. Any ideas? This is a central air unit that is less than 6 years old.


Check the relay or sequencer that controls the blower if it has one of those. If the fan is controlled by a circuit board then you problem may be there. If it is controlled by a circuit board then you can check for power at the fan connection when th ... Goodman CKL24AR24 Air Conditioner

I have a Trane XE 1100 outdoor unit. I had to refill the freon gas 3-4 times in 3 years. The technician mentioned that I need to replace the outdoor unit. last night, the outside unit was running and the unit in the attic was running and the copper pipe was cold and wet, HOWEVER no air was coming out of the vents all over the house. Do you have an idea WHAT IS THE PROBLEM ? My question: Do you have an idea How much it costs to replace the outside unit ?


... Air Conditioners

I have central air ( Dimond 80 York Heating Air conditoning Unit ) My air conditoning unit has stopped working. The board has checked out ok.but there seems to be a voltage problem some where from inside to the the air conditoning unit outside, the voltage reading is 26 inside and only 10 outside not enough to start the unit . Do You have any idea as what the problem might be? Thank you, drewskie


Try the following step.....On a call for heat, the 24 volt thermostat sends a signal to the\015\012control module. The control module will indicate a call for heat with a\015\012light on the control either blinking or remain solid d ... Air Conditioners

Bryant air conditioner - outside unit will not run - before it quit running, air temperature in house rose from 65 degrees to 75 degrees. Inside fan continued to blow - air smelled like a car air conditioner that ran out of Freon. Bought Freon - need to know where to add it. The heat pump model # BF-163S bi directional but also coming from unit is another line that runs same direction with same type of valves. Air conditioner model # 697CN030 - B


... Air Conditioners

I have a goodman cpk j42 -1b ac unit on the outside and a central heat and air unit inside. the ac unit come on and runs fine but when it hit the temp the thermastat clicks and the fan outside goes of but the one inside stays running and will not turn off unless i hit the breaker. is it he fan relay at the outside ac unit?


Hello BWOOD Check the thermostat FAN button is in AUTO position not ON position.That might be it .The relay is in the blower unit but they RARELY become frozen/welded stuck on. ... Air Conditioners

We have had a coleman central air system for 5 yrs. It stopped blowing cold air into the house about a week ago. You can still here it running but no air is coming out. my husband replaced the fuses and over night it did the same thing so when my husband went to check out the unit outside he said that the line had ice on it. Is there a filter within the central air unit that needs replaced?


Ice is an indication that the refrigerant is not flashing off correctly in the evaporator coil. In most cases you can simply turn the unit off (until it completely thaws inside and out) and replace the filter. Make sure that all the vents in the hous ... Coleman Air Conditioners

Can somebody help me with my malfunctioning (central) unit? My Tempstar SmartComfort 2200 air compressor does not engage, no cooling in home. The fan runs outside and the inside thermostat works but t


... Air Conditioners

Sometimes, when the inside blower shuts down, the outside compressor and fan motor continue to run for some time. Other times, when the inside fan motor is running, the outside fan and compressor motors are not ... if I press the outside reset button, it starts up When both inside fan motor and outside fan and compressor motors are running, it works fine ... warm air blows out of registers. Other than that problem, both units work great!


Sounds like you have a dirty condenser. You are going to need to disconnect the power at the outside unit on the wall by pulling the fuse block out. Take a good look at the louvered covers that are attached to the outside of the unit. Remove the scr ... Ruud UAKA060 Air Conditioner

My coleman Mach Rv air conditioner with built in heat strip keeps tripping it's internal circuit breaker when running for any length of time. Just replaced heat strip with new one experienced same issue. I ended up with the fan continuing to run but only cold air comes out of the vents! When I removed the old unit and reset the circuit breaker it too worked again. Have no idea what is causing this to happen. The airconditing part of unit works just fine??? HELP! Ron


There should be an overload protection device in series with the low voltage wiring(t-stat wiring) Is it resting on the heat strip or too close to it? It is a saftey device to shut off the heat strips if the fan quits or a fire in the heat strip sec ... Coleman Mach III Air Conditioner

I have a Lennox Merit series residential AC unit, my furnace engages and blows air but the outside component WILL NOT turn engage! Furnance fans runs continuously with cycle as if outside unit was working but the outside unit will not engage.


... Air Conditioners

Hi, I have a samsung aqv18ja series split type air conditioner (cooling and heating) wall unit. the unit was install in 02/12/2009. By "one hour heating and air conditioning". In this short time service the outside compressor has been replace, the system has check and recheck,for cooling leak. the inside unit fan motor has been change. but the problem still exists. The inside unit fan continues to run when the unit is "off" and with the remote off.


Simple, check in your remote. There is an option button "Blow". Just press it. Your unit gets completely off. Please write back if helpful? ... Samsung Air Conditioners

I have a Dometic 15,000 btu, ducted air conditioner in my 30 ft fifth wheel. It seems like the unit has never cooled very efficiently. Dealer has checked out. I noticed yesterday, outside air over 100 degrees, that the air conditioner would put out good flow of cool air, but once in a while compressor would stop running even though not close to thermo setting. Fan would continue running. Any suggestions?


Not sure what the pressure sensor should ohm at but i would suspect a faulty sensor if everything else checks out. Its very common for these sensors to exhibit issues when they get hot. Also you may have a filter in the system that may be restricte ... Dometic Rooftop RV Air Conditioner

Outside unit does not run but fan continues to run inside blowing out hot air. system works fine for a while then the problem happens after system has ran for a while. water leaking from inside unit in house. unit is a coleman model #663CJ036-E. Any information we be helpful.


Your system may have multiple power disconnects that you should check first. You should have 2 double pole breakers in your breaker panel, one controls unit inside and one controls compressor outside. Make sure you try to reset these breakers by turn ... Coleman Air Conditioners

Central air unit sometimes comes on but after the unit outside kicks off the fan inside keeps running and the unit outside clicks and dont come back on


Hello,this can be caused by a defective capacitor, the cap helps to start the compressor and outdoor fan on the outdoor unit. Looks like a silver D size or larger cylindrical object. it will have a few wires going into the top of it. Usually they ... Air Conditioners

We just turned on our central air conditioner last night. today the temp of the house was 80 degrees. someone in the household placed the tempature on 70 degrees cool on auto. we have not felt any air coming out of the vents. the central air unit is running. any idea why this happened. our thermstat is not programmable.


Did you hear the indoor unit running (the fan blowing)? If so, there's a good chance that either the filter is plugged or more likely, the evaporator coil is iced up and preventing any air from flowing into the dwelling.\015\012\015\012T ... Air Conditioners

UNIT RUNS AN EXCESSIVE AMOUNT OF TIME AND AIR IS COOL NOT COLD COMING OUT OF VENTS CARRIER 58DLA / 58DLX CENTRAL AC FAN AND COMPRESSOR ARE OPERATING BLOWER IS WORKING UNIT IS TURNED ON TO AC TEMP SET AT 76 UNIT RUNNING FOR OVER AN HOUR OUTSIDE TEMP 80 THERMOSTAT REGISTERING 77


DOES THE HOUSE FEEL DRIER IF IT IS 80 OUTSIDE WITH ALOT OF HUMIDITY THE UNIT WILL RUN FOR A LONG TIME TO REMOVE THE MOISTURE(HUMIDITY) OUT OF THE HOUSE BEFORE TEMP DROPS DRAMATICALLY IS THERE WATER COMING OUT OF THE DRAIN PIPE OUTSIDE ... Carrier Air Conditioners

Central air unit problem.......It starts out blowing cold then will only blow room temp air after some time. I don't see anything freezing up..Filter is clear. The unit outside is not clogged up. The copper line running in is getting very hot..


Check your outside unit to see if fan is running. If it is running check to see if air is blowing out if not you have a bad capacitor. Some times if a capacitor shorts out the fan will run backwards and the line will get very hot same as if the fan i ... Air Conditioners

The outside unit is making a squealing noise. It's every now and then; not constant. Just started today. What's wrong? The fan is running fine. The air inside is cool. Just a high piercing squeal every now and then from the outside unit. Any ideas?


Sounds like its more than likely the fan motor. the bearings in the motor are notoriuos for making a squeeling noise. there arent any other parts that would make this noise. unless youre a special case. i doubt it. if youre mechanically inclined ther ... GE Quiet-Aire Ductless Split System Air Conditioner AS1CD12AA0/AS0CD12AA0

My carrier air conditioning unit does not cool below 72 degrees. I was continually running to the point the outside unit connection to the house was frosted. I turned the unit off and let sit for a few hours. Turned it back on and the Thermostat seems to be working; however the unit can not cool the house below 72 when it had in the past. Am I looking at a leak or re-charge???


The unit has lost part of it's charge, and will need recharged. For that reason a leak must be found and repaired or it all will reoccur again. ... Carrier 38CKC030 Air Conditioner

My colmen central air unit is not working properly. The Outside unit is not working. The problem initally arouse in June, but it "self corrected" after having the A/C unit turned off. Since that time the unit has run perfectly untill now. I did look for a reset button, but was unable to find one. The system (at most) is only 4 years old.


If nothing is running outside at times you probably have a weak contactor coil that is not pulling the contactor in all the time. If the outside fan comes on but not the compressor, the compressor is over heating and ... Coleman Air Conditioners

Details I have a problem with a Goodman Model GSH130601AA, ( 5 Ton, 13 Seer heat pump) central air unit, installed 06/15/2006. (I know, I saw online reviews but unit was put in before I saw negative e


The fan motor is bad and needs replaced. Depending on how mechanically inclined you are, you can replace it yourself fairly easy, the hardest part being the fan blade without a hub puller. Just take your old one in with you to a local A/C supply stor ... Air Conditioners

I have a 561c central air unit. I just replaced the fan motor and capacitor 6 days ago. The unit ran great for just that long now the fan won't come on and the outside unit is hot to the touch, I can assist the fan and it starts and runs great until it reaches the thermostat temp. When it turns off it won't come back on. Is it the start relay switch?


Sounds like you need another capacitor since it will run if you turn it by hand to get it started. If you have a clamp on ammeter check the current draw on the fan motor. ... Air Conditioners