I installed a new honeywell rthl111 series in Oct. 2012. I wired the blue wire to the RC because that was how the old thermostat was wired. The heat worked all winter but when I tried to change over to cool nothing would work. I checked the schematics online and realized I should have installed the blue wire to the B. I checked the fuse in the power panel and saw I had blown it. I changed it and rewired the thermostat the correct way. I tried again and still neither the cool or heat will work. A


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I installed a new honeywell rthl111 series in Oct. 2012. I wired the blue wire to the RC because that was how the old thermostat was wired. The heat worked all winter but when I tried to change over to cool nothing would work. I checked the schematics online and realized I should have installed the blue wire to the B. I checked the fuse in the power panel and saw I had blown it. I changed it and rewired the thermostat the correct way. I tried again and still neither the cool or heat will work. A


... Goodman Air Conditioners

I have an amana rha36b2a heat pump and am trying to hook up a new thermostat. It's a pro 1 iaq t905 programable thermostat. I have hooked up the green yellow white and red (and ran a jumper wire from rh to rc). I also ran a jumper wire from W to Y. I ran the brown wire to C. The thermostat works great for heating but won't cool. When cool is chosen the heat comes on. Help! I know the O and B on the thermostat are the heat and cooling changeover valves but what should I do to connect them if that


... Air Conditioners

I have an Amana RHE30A2B heat pump. I installed a new thermostat, Honeywell, last night and now the coils are not cooling & the unit is blowing hot air. I have double checked all the wiring & everything seems to work as it should. Is there a breaker or fuse on the outside unit that I am not aware of before I call a service man out. We also had an electrical storm last night. It could be a freak thing, but I am still concentrating on the thermostat.


Hello,If you can hear a click or see a light when you turn your thermostat from up to down you do have power there. Or, you can put a meter on your thermostat and see if there is any voltage or not. If not in either case, you can try this ... Amana Air Conditioners

Goodman GSH130301AB heat pump with Braeburn 1200 multi-stage thermostat - both less than 1 year old and installed in new construction. Heat can be set at 60, fan on AUTO, with room temp at 70 and heat will kick on and stay on. When this happens, turning thermostat to OFF does nothing - system continues to blow heat - and I can only shut it off by flipping the breaker. This only happens now and then - typically works fine. All wiring appears to be correct though reversing valve for cooling is


The reversing valve wire needs to be on the o terminal.nothing will be on the b terminal on the thermostat ... Goodman Air Conditioners

I just installed a P474-1100REC & P474-1100RF in place of a Honeywell Thermostat.I have a typical 4 wire 1 stage Cool 1 stage gas heat setup. The new thermostat is not working right. I noticed on the old thermostat there was a jumper wire from R to R1. Do I need a jumper wire set-up here as well? If I do where do I connect to? There is no R1. Please help


Does the new stat have a rc and an rh if so you will need a jumper between them ... Air Conditioners

We installed a Honeywell RTH230B thermostat on a Trane XE60 Air Handeler this winter. When we put the system on heat it works fine. However, when we put the system on auto for cool the compressor fan comes on but not the air handeler fan. On the air handeler the terminal strip from left to right is R W Y G B/C. The red wire on the R terminal comes from the contactor on the compressor unit. The other wire from the compressor unit is connected to a gray wire that goes to the thermostat. The W


I ran into this before and had to call Honeywell for help in the wiring...it seems the wiring was not done to standard, and they were able to help me get it straight in about 10 minutes and at no charge. ... Air Conditioners

We live in southwest Florida. Our HVAC system consists of a air conditioning system with heating coils when it is cool. Yesterday morning we tried the heat nothing come on. Later in the day I tried the air nothing. I tried turning in just the fan nothing. I just checked the breaker I have power where the wires are connected. I went out to the outside unit and pulled the cover. Pushed in a spring loaded plastic switch the fan on outside unit works and shut off when I released the switch. But noth


Hello. Sounds like you do have power. That spring loaded plastic switch is a 24v contactor. It pulls in when energized. If you push it in manually everything shoud run normal. Ck your 24v transformer. On one side (feed) you should have 115v or 220v ... Air Conditioners

I have 5 Hampton Bay ceiling fans originally installed in my 2001 home. 3 have light kits and work great. I am trying to install lights on the remaining 2 but get no power. The 2 wires (blue and white) have the proper connections that match the connectors to my light, but no light comes on. I checked with a volt-meter and it gives me zero volts. All of my wall power switches are on and the fans run but no power down to the light connector wires. Can you help me? THANK YOU........Joe


The supply power to the fan from the house should be HOT 24 / 7. The two lines going to the fan normally have wire nuts for connecting the leads on the fan to the house power supply line and the house common line. You want to tie the blue line on the ... Hampton Bay Air Conditioners

I installed a Honeywell TH5220d 1029 thermostat on a American Standard AC/Heat pump and the install and setup went fine. It cooles for about and hour and quit. I found the 5 amp fuse at the furnace blown. I replaced the fuse and it blew again in about 2 minutes. Have followed the wires, checked for shorted or crossed wires but it all seems OK. Tried one more time and blew the fuse right away.?? Any good idesa?


Red wire to R on thermostat red on furnace and red on heat pump Same with white except w1 on thermostat. Blue to common on thermostat common of furnace (probably brown but will be marked) and blue to common on heat pump. yellow to Y on thermostat and ... Air Conditioners

I have a hunter programmable thermostat model #44155c and Im trying to wire it to my goodman furnace. Its a 7 wire system with a white,yellow,red,green,brown,blue, and orange wire. The ac works fine but the heat wont shut off. Thanks


Make sure you do not have a jumper between the red and the white. Also make sure the wire is not hanging out from behind the screws. If the heat stayes on no matter what you do. The red wire has to be touching the white somewhere. \015\012The r ... LG LSC183VMA Split System Air Conditioner

HONEYWELL RTH230B thermostat: we just installed the honeywell rth230b. The fan is working, but it's not turning on the outside unit. We pressed down on the thermostat slightly and it triggered the outside unit on for a split second, but it wouldn't stay on. After reading one of your forums, we disabled the blue wire, and made sure red, green, and white were in correctly. (we don't have yellow). Any ideas? The fan and vents are blowing cool air, but the house is 83 degrees and climbing (because t


Hello,what you have to do now from here is that check the capacitor if the maize i.e (wire)_ that pass current over to the compressor is well fix because this well the unit get is own supply to the over load then the relay sec ... Air Conditioners

I installed the rth2310 and it seemed pretty straightforward. I had R, W, Y, G, on the old thermostat, and hooked them up to the same, with R to Rh with the jumper in place. Now, the snowflake cooling symbol is on all the time, and when I turn on the heat, it just runs all the time. This is a zoned system. I replaced another thermostat at the same time, and it works fine (it had a black wire going to Y, but otherwise the same).


You need a jumper between RC and RH. ... Air Conditioners

I own a non programmable digital thermostast RTH3100C THAT WAS INSTALLED AND KEPT MY AIR CONDITIONER COOLING WELL. HOWEVER, WHEN I TURN TO HEAT IT WOULD NOT HEAT THE PLACE. I JUST GOT COOL AIR. I WAS INFORMED BY YOUR CO. THAT THIS THERMOSTAT IS NOT FOR HEATING. I HAVE AN A/C WITH A PACKAGE OUTSIDE AND AN INSIDE AIR HANDLER WITH A HEAT ELEMENT. COULD IT BE LHAT IT WAS NOT PROPERLY WIRE. I ONLY HAVE THREE WIRES FROM THE OLD THERMOSTAT


Are there any wires on the e or aux terminals. those are the terminals for heat ... Air Conditioners

Carrier thermostat Hello, My Carrier electronic thermostat is connected to a heat pump.  It was set to the COOL position during a summer thunderstorm when the AC suddenly began running no matter what the SET temperature was.  It works normally when I change it to the AUTO position.  The HEAT and EHEAT positions work normally. I tried cutting power to the unit for 2 days, after which it worked normally even on COOL, but after a short power failure it resumed the problem of running the AC continuo


I hate to say it but Ive had trouble with Carrier's Tstats doing similar improper things. Unfortunatly the only repair is going to be replacement of the whole tstat. I recommend Honeywell's FocusPRO or VisionPRO tstat. Ive yet to have one fail and th ... Air Conditioners

I have a DuoTherm BriskAIr 13.5K BTU. The Dometic thermostat also controls my HydroFlame 8531-IV furnace. This morning, the furnace would not come on. I checked the wiring and there is no voltage at the thermostat blue wire on the furnace. If I jump 12 volts to the thermostat blue wire, the furnace works normally. Replaced thermostat; no change. I hear something clicking in the air conditioner unit when I switch the thermostat to furnace mode. I assume the A/C has a relay to control the thermost


If you look at control box at roof unit, they usually use a separate set of wires for furnace. See what colors they are attached to at harness to thermostat. Some just follow other harness, and come out at thermostat. (bypass control box) Once you've ... Dometic Rooftop RV Air Conditioner

I have an older Carrier Heat Pump which I am trying to update the thermostat control with a Hunter model 44550. The problem is that the wiring to the current thermostat is as follows, G= green wire, R= red wire, W2= blue wire, O= orange wire, Y= yellow wire, E= grey wire and C= white wire. If I am reading the schematic correct for the Hunter thermostate I am to wire as follows Green to G, Red to RC, Blue to W, Orange to O, Yellow to Y/Y1, C cap it as batteries are used. It does not tell me


JUMPER STAYS BETWEEN RC AND RH SO YOU HAVE INCOMING POWER FOR BOTH COOLING AND HEATING. THE WHITE WIRE YOU SAID C IS COMMON AND SHOULD BE USED IF POSSIBLE TO COMMON TERMINAL ON NEW STAT . IF THERE IS NO COMMON, THEN CAP IT BUT YOU'LL BE CHANGING BAT ... Carrier Air Conditioners

Heating and air condition unit will not kick on when i try to turn the heat on in the morning. we have tried the auto fan and the on fan for both ac and heat...will only work for the ac. the breaker switch at the breaker box is the only solution we have found to get the unit to fire up and to start the heat for the unit...my brother has checked the wiring at the thermostate..mercury type..found no burned out wires...he changed the filter on the system...tried to clean all the contact points on


Hello , I can help you out here. First check the T-stat with all breakers on take the red t-stat wire and white t-stat wire and green t-stat wire , tie the 3 together and wait 5 minutes to see if anything starts up. If the heat starts running replace ... Air Conditioners

RTH221 honeywell thermostat install, hooked up blue wire from old thermo that hooked to C to o/b connection on new thermostat no work did I screw something up as old thermo will not work as well now. was not supposed to hook blue wire up I found out later on Internet. any easn fix, blown fuse??? etc. Thanks


Hi,\012maybe a blown fuse if it has one... if not then you blew the transformer...\012Check on the circuit board in the furnace or air handler for a fuse...\012if there isn't one... then you will need to replace the 24v transformer. ... Honeywell Air Conditioners

Reset button for Ruud Achiever 14 heat pump/AC compressor? My Ac/heat thermostat was blowing fan on and would not turn off. I switched it off at the circuit box, and bought a new thermostat RTH221, wired it and it would not blow cool air when on cool nor warm air when on heat. Called the 800 number for Honeywell and tech said I had wired it correctly, to check outside and see if the compressor was running. It was not. This Ruud unit is only 8years old so I'm wondering if a reset button has


... Air Conditioners

Suburban sf30 rv unit.. I had a new board and limit switch installed. The service tech said it was working. I marked the wires when I removed the unit. I re installed the unit conecting the wires the same as when I removed the unit. I have 2 blue wires, 1yellow and 1 red coming from the furnace. There are 3 thermostat wires 1 grn, 1 wht and 1 red---The power source are 2 solid white wires and 2 blk and wht striped wires, there is power to the unit. I am at a loss as to why it will not work. T


... Dometic Rooftop RV Air Conditioner

I have an intertherm rpbmb030k combo a/c and heat. Had frion put in the unit over the summer and a new digital thermostat. Unit has worked great until we needed heat. Unit works great on aux. heat but keeps switching to to defrost mode when standard heat is on. Switched out the defrost board on the unit to no avail and an a/c guy checked to ensure the new thermostat was wired correctly.


Hi, if the unit had a leak in it, was the leak located and repaired? Did he check the pressures in the unit now? If it switches to the aux mode ( Heat Strips ) is normally caused when your primary unit, compressor and freon are low on charge. I would ... Intertherm P3RA-060K Air Conditioner

Goodman AC Unit with Heat Pump - Works great cooling when switched to heat the outside unit does not come on - inside comes on and uses emergency heat? What can I check? I first checked the contactor and it looks fine, the inside thermostat had low battery voltage...replaced batteries but still not working? Any help? Thanks


Because the outdoor unit works in cooling, it sounds as though the contactor and other components outside are working correctly. The problem sounds as though it might be somewhere in your thermostat. Has the thermostat been replaced recently? If so, ... Goodman CKL60AR60 Air Conditioner

I have a Tempstar model NFCP3600A1 (style # FCP3600A) ICP Heat Pump. Starting last week, the unit kept heating well over the set temperature. I swapped out the thermostat thinking it went bad, but it still continued heating and the "off" wouldn't work at the new thermostat either. Next, I checked for shorts in the thermostat wires and they seemed OK. I then replaced the TI 26FC-2 circuit board. Once the unit heated the house to the set temp, it continued running up to 75 degrees. "Off" and lowe


... Air Conditioners

I have a tempstar with 6 wires. Green, Blue, Red, Yellow,White, and Orange. I am trying to install a White Rodgers 300 thermostat and letters are not matching up. The thermostat has G, A, RC, RH, O, B, Y, and W. I don't know where to hook the blue wire which was labeled C. Unless it goes to RC and the red goes to RH could you please help? Thanks


You need to verify the function of each wire with Tempstar then cross it with the WR stat. Call the techline if you need further assistance 18002842925. ... Dometic Rooftop RV Air Conditioner

We have a Carrier Heat pump. Today the heat pump and (gas) furnace turned off completely and the thermostat is blank. We've checked the fuses and they seem to be fine and everything else is working well. It's forecast to be in the high 30's over the next few days so having the heat pump/AC working is a necessity. The installer can't get here for 2 more days ( he doesn't work weekends). I don't have any idea what to do. Help - help!


Is the thermostat battery powered or powered by the transformer. If it is powered by the transformer then the transformer may have gone out. Turn the thermostat to off. Use a multimeter to check for 24 vac between R and G on the thermostat. If you do ... Air Conditioners