I am working on a FEDDERS ductless mini split. Model# FESI-HHD012-H15D ( inside unit) Model# FEAU-YHD012-H15D (outside unit). The electrician wired it up to 220vac and its only a 120vac system. I hav

\015 I am working on a FEDDERS ductless mini split. Model# FESI-HHD012-H15D ( inside unit) Model# FEAU-YHD012-H15D (outside unit). The electrician wired it up to 220vac and its only a 120vac system. I have replaced both circuit boards and now I am getting a error code C5. It says "jump wire cap malfunction protection". Does anyone out there have any idea what that is saying? There is an EMI filter and two large capacitors 2200mfds each. Any help would be greatly appreciated.\015

Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I am working on a FEDDERS ductless mini split. Model# FESI-HHD012-H15D ( inside unit) Model# FEAU-YHD012-H15D (outside unit). The electrician wired it up to 220vac and its only a 120vac system. I hav


... Fedders Air Conditioners

I purchased an Amcoraire split system unit for my 2 story garage. Licensced electrician did the wiring and licensed HVAC co. installed the 2 indoor units and outside unit. Outdoor unit is Model # AOM 243 HX 24000 BTU Indoor units are both Model #AWM123 HX, 12000 BTU each When I turn the unit on, it runs for about 60 seconds and then I get an error code on the inside wall unit that says P7. My manual says this has something to do with voltage. I had the power company come out and they show the


Since the manual says the error code has something to do with voltage it means the voltage is either too high or too low. And as the electric company says the voltage is within limits the the error is as a result of the voltage fluctuating. All you h ... Amcor Air Conditioners

We live in southwest Florida. Our HVAC system consists of a air conditioning system with heating coils when it is cool. Yesterday morning we tried the heat nothing come on. Later in the day I tried the air nothing. I tried turning in just the fan nothing. I just checked the breaker I have power where the wires are connected. I went out to the outside unit and pulled the cover. Pushed in a spring loaded plastic switch the fan on outside unit works and shut off when I released the switch. But noth


Hello. Sounds like you do have power. That spring loaded plastic switch is a 24v contactor. It pulls in when energized. If you push it in manually everything shoud run normal. Ck your 24v transformer. On one side (feed) you should have 115v or 220v ... Air Conditioners

AMCOR 24,000 BTU split system. Worked fine two years, then today it had no power. Checked circuit breaker, it had popped. Reset CB and went to inside unit - would not turn on or off with remote or hard button. Checked wiring with an electrical tester, and wires to outside unit hot, as well as inside unit. No flashing codes, nothing. Unit won't turn on,even with power. Is there a fuse somewhere in the inner unit or outer unit?


I had this same problem. I disconnected the thermostat wire out side at the condenser and reconnected it and it started working. A couple days later it blew the breaker again this time I found the bus where the L1, L2. GR wire connect at the condense ... AmcorAire UCHW-H24AF2 Split System Air Conditioner

A/C need hlep with a carrier model # 40aq030-300bb. just bought a house with this unit inside but outside different unit, think its a Goodman. When turned to heat everything ok, but when turned to cool it still puts out heat. Think reversing valve is bad or switch controlling it may be bad. Not to familiar with the system and wiring diagram is gone. Somebody made a mess of the wires anyway, need some help if you have any. Thanx and... GOD Bless


Orange or O terminal on Tstat energizes valve in colling cycle. Go to outside unit jumper red to orange and see if Reversing valve energizes. If it does . Problem inside possible Tstat. You shoulf here the valve click. Have someone inside switch fro ... Air Conditioners

19 seer infiniti system, system will run for 2 mins. and then cut off and it will not show a code to the outside unit board or the thermostat. Replaced the thermostat and the outside low voltage wiring, then went to test mode on thermostat. Turned high cooling for 15 mins, it will run for 10 mins and then cuts off. It still does not show a code. If you go to the thermostat and turn it off, and reset it to cooling it will run for 2 mins and will cut off.


This cut off is very likely being caused by a defective compressor module thermo limiter (prevents overheating the compressor), replace it. ... Air Conditioners

Ruud heat pump outside unit not starting. Open and found contactor disengaged even though I have system on from inside. Low voltage wires come out of a circuit board checked for 24v, none. Then bypassed board by unplugging same yellow and brown wires plugged into the board and exiting but now I have 24v getting to contactor but it does not engage contactor. What could the problem be. I know a little a/c but these heat pumps are very complicated. Help please, I want to learn.


If you are getting the low voltage to the relay and it is not closing, then the relay may be either bad or stuck. Disconnect the 220v and see if the contacts can be manually closed. I always use a piece of wood or something non-conductive. If the ... Air Conditioners

Have a split unit a/c, outside unit starts, runs for about 5 mins then shuts off, electrician looked at it and said compressor drawing high amps and it's shutting it down due to overheating? could it be air in system or dirty condenser or evaporator?


It could be. It could also be a problem with the capacitor or a restriction in the refrigerant lines or a low charge due to a leak in the system. ... Mitsubishi Air Conditioners

Our rheem RAHE 036JAS central air's wire (electrical? it looks like it.) that's connected from the unit (gas heat) inside the house to the unit (compressor) outside the house was cut clean. who do i call to fix it? an electrician or an hvac tech? thank you.


... Air Conditioners

I have a friedrich mr18y3ea outside unit and mw18y3e inside unit what size wire for the two unit i think doublepole 20 amp outside unit 12 wire do you need a sept. wire for the inside unit or it come off the outside unit


... Friedrich Air Conditioners

My dog chewed up the t-stat wiring on my outside a/c unit (compressor?). I purchased some t-stat wire at Home Depot and replaced the wiring. At the outside unit, I connected the new white wire with the brown from the unit, and the new red wire with the yellow from the unit. This part was still connected from the previous install, so I copied from how it was wired before. For the wiring to the house, this was disconnected completely by the dog, so I connected the new white wire to the white w


Hello,Yes there is a 3 amp blade fuse(same as in a car) in the blower unit,take off the door and it is plugged in to the(curcuit) board.Pull it out and slip a new one in.That will restore the control voltage.Your repair sounds correct.Some times ther ... Air Conditioners

I have a Carrier HVAC unit model #38TKB62300 and the unit outside stopped working. From the exposed wires outside the unit, I noticed that when I pulled gently on some wires, it make a clicking sound. So I took off the cover and back panel and literally the wire connector, feel out of the box. I have detailed pictures of the wires that are not connected. There is a "Brown" wire and "Red" wire that are not connected, so I touched them together to find the Capacitor moving in and out. However,


There is a short either in the wiring or one of your motors ... Air Conditioners

System Malfunction, No communication with outside unit


I work on Carrier Infiity systems. The outside board has a Model plug on it. This tells the system what size unit it is. They do go bad. You can reset your self by turning the power off to the Air Handler. These system have 10 year warranty and if yo ... Air Conditioners

MSZGE12NA, OUTSIDE UNIT LED BLINKS SIX TIMES , INSIDE UNIT BLINKS CONTINUOUSLY. OUTSIDE UNIT WILL NOT RUN, INSIDE UNIT DOES. NO HEAT, COOL. CONTROL WIRE BARE "DRAIN" LINE CARRIES A LOAD THAT ARCED AGAINST OUTSIDE CABINET. THIS WIRE IS NOT ATTACHED AT EITHER END YET IS UNDER A LOAD. WHY IS A MYSTERY.


... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

I need the wiring diagram to wire a thermostat to the outside unit. Which wire goes where ? My Thermostat has four wires, green, red, white, and yellow. My Outside unit has three wires that are not connected ... a red wirte to a transformer, a yellow wire to what appears to be a relay, and a blue wire to the relay switch. Thanks.


The thermostat wires are this, Red is 24 volts hot, Yellow is cooling, Green is fan,indoor, and white is heat.The outdoor unit wires up to the indoor units terminal board, not the thermostat.The red will go to the R or red 24 volt wire at the furnace ... Air Conditioners

I have a yonan Ac model # kfr-35gw/gx1b split system the problem is the L1 wire coming from the unit outside to the relay is burning what could be the problem I checked the relay and it seems ok could it of been because of a loose connection. If it is the relay then the whole pc board needs to be replaced none of the parts are serviceable which leads to the second problem is I can't get anyone form the company who makes this to respond


... Air Conditioners

I have a Yonan split Ac model # kfr-35gw/gx1b split system the problem is the L1 wire coming from the unit outside to the relay is burning what could be the problem I checked the relay and it seems ok could it of been because of a loose connection. If it is the relay then the whole pc board needs to be replaced none of the parts are serviceable which leads to the second problem is I can't get anyone form the company who makes this to respond


... Air Conditioners

We salvaged a Goodman outside unit HDP24-1B and an inside WM25CR from one of our renovation projects. These were the best looking units from about 10 total in a Church we converted to daycare. The HVAC subcontractor tried to install the unit in our guest house and is having trouble due to no wiring diagram. He said if I find diagram he can hook up. All is done now except running wires from the inside unit to the outside unit. Can you help? After all this I hate to throw units away. Though


Hi,I have watched this question site here for days and as far as I can tell you have not received an answer to it...The problem is that the scope of this question is way beyond what can be effectively communicated...with out the pro ... Air Conditioners

I Installed a spit unit that I removed from my office. The brand is McQuary. The inside Evaporator unit is a model# WM20C/25C. The outside condenser unit is Model MDCX18-18. Somehow I connected the 240V wiring incorrectly and the outside unit doesnot start. Please provide me with the correct wiring installation


Is there a chance that the outside unit gets the line connection (from your breaker), and sends it to the inside unit? In that case, you'd wire the L1 to one leg of the 240, the L2 to the other, and the white would go to the neutral. Obviously you ... Air Conditioners

Ruud UPNE- 036JBZ 2 years old (outside unit) Ruud Acheiver air handler 1 year old inside unit... outside unit will not come on. voltage (120) ready at contacts. push manually and it comes on. yellow wire and brown wire go to board. no power on these when inside unit is running. power bill has doubled......must be running off heater coils? What would be the next thing to check. I did look at thermostat seems to be working normal. Can't get knowledgeable help.


... Air Conditioners

I have a Trane xe 1000 and the dog ate through the wires outside. There are now a blue and yellow wire coming out of the unit and red and white wires coming from the house. Without them connected the outside unit does not come on even though the blower in the house is blowing air. Which wires get reconnected?


... Air Conditioners

I turn on the Central A/C unit with the thermostat. The attic fan unit goes on and the system cools the house. When the system shuts down the fan unit shuts off but the outside compressor keeps running. The only way the outside compressor goes now off is when I flip the 240 switch on the main box. This just started. Is it a thermostat problem? Thanks.


Could be a thermostat problem but even more likely the contactor on the unit outside is stuck. In order to change this part you will have to get in to the outdoor unit. The contactor is the automatic switch that the thermostat energizes when the t ... Air Conditioners

I have an Amana a/c unit and the compressor outside keeps stopping however the fan goes on. The a/c service guys have been to my house 3 times and the wires each time were burnt. The last time they change the capacitor and and new heavier guage wires and it lasted for about a month. When trying to turn iton now I am back to the same situation. Do you think I should I go for a compressor or change the unit ? It is a 4 ton model BBC60a2A and the outside unit model number is RCE42A2A . Thanks


... Amana PTH123B35AJ Air Conditioner

We installed a Honeywell RTH230B thermostat on a Trane XE60 Air Handeler this winter. When we put the system on heat it works fine. However, when we put the system on auto for cool the compressor fan comes on but not the air handeler fan. On the air handeler the terminal strip from left to right is R W Y G B/C. The red wire on the R terminal comes from the contactor on the compressor unit. The other wire from the compressor unit is connected to a gray wire that goes to the thermostat. The W


I ran into this before and had to call Honeywell for help in the wiring...it seems the wiring was not done to standard, and they were able to help me get it straight in about 10 minutes and at no charge. ... Air Conditioners

I have a colman evcon split unit, I had a guy replace the thermostat (old electronic, new mercury) and everthing worked fine. One week later out side unit stopped and was frosted over on the outside. I can push the contactors on the outside unit and got power. I traced wiring down to transformer. I replaced the transformer with one with a circutbraker built in. When i turn the brakers on the transformer curcuit breaker trips...I followed the wiring on the transformer to the best of my ability, h


Hi, you do have a dead short in the control side of the system. Good that you bought a transformer with the breaker. Most people don't and will smoke several of them. Anyway, it is a split system. If it was iced up, it must be a heat-pump, not gas fi ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific