Having problems with your Air Conditioners ?

1990 Goodman air conditioner model CE36-130 is it a 3 ton or a 2.5 ton unit?


Answers :

3 ton 25 years is great service for a/c

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

1990 Goodman air conditioner model CE36-130 is it a 3 ton or a 2.5 ton unit?


3 ton 25 years is great service for a/c ... Goodman Air Conditioners

Evaporator Coil I have a Goodman A/C system (2 systems...1 for 1st floor, 1 for 2nd floor). The one for downstairs is 3.5 ton. the one for 2nd floor is 3 ton unit. Installed when house was built 5 1/2 years ago. The upstairs unit has had the evap coil replaced once, and repaired a leak once - 6 months ago. The downstairs unit has had the evap coil replaced twice -and is now leaking again. Model for the air handler is ARUF042-00A-1A. Goodman part# for the coil is P140142. Can I replace this coil


Yes, just count how many pins per inch and replace with the same number of pins per inch. ... Air Conditioners

I have a goodman air conditioner model # CK30-1T, is this a 1 ton unit


2&1/2 ton unit ... Goodman Air Conditioners

What should the psi be on 1 1/2 ton ac unit? - Goodman Air Conditioners


On r-22 should be 68-74psig on high side 230 to 260psig depending on heat load and ambient temperture ... Goodman Air Conditioners

My son has a Goodman Manufacturer Corp Heat Pump/air conditioner. Forced air I believe. The air conditioner quit. A repairman indicated that in order to replace the air conditioner the furnace will have to be replaced also. The air conditioner unit outside is Model No. CPE30-1-AB. Any thoughts?


I don't see any reason to change the furnace unless it's an air handler and not a furnace with a coil on top or bottom. And then, the only reason to change the inside unit when you change the outside unit is because it's a R-22 system and your going ... Goodman CKL30AR30 Air Conditioner

Details I have a problem with a Goodman Model GSH130601AA, ( 5 Ton, 13 Seer heat pump) central air unit, installed 06/15/2006. (I know, I saw online reviews but unit was put in before I saw negative e


The fan motor is bad and needs replaced. Depending on how mechanically inclined you are, you can replace it yourself fairly easy, the hardest part being the fan blade without a hub puller. Just take your old one in with you to a local A/C supply stor ... Air Conditioners

I have a Goodman 2.0 model no. ck24-1B and would like to change it to a 2.5 Ton 13 SEER R-410A Air Conditioning Condensing Unit. My furnace is a Goodman model # GMS8, GDS8 or GHS8 are they compatible


If it is a 410a system now you would have to change orfice. if its a r22 system now no way. ... Goodman Air Conditioners

Hi, I have to replace the capacitor (35 +2 microfarad) for my LG 1 ton, split Air Conditioner. The LG service guys had told that this model is nomore available with them. They tried some alternatives, but did not work out. So, in India, where would i get the exact capacitor for the LG 1 ton, split AC


Are you sure the capacitor is faulty? You can go up in U,F's but not down and if it is the capacitor it will work. For instance, you can use a 40x5. The larger number is to start the compressor ad the lower is for the outdoor fan motor. I know nothin ... Air Conditioners

Hello, We bought a Perry Home in Georgetown TX last March and it is still under its two year warranty. Our air conditioner stopped cooling today. It has been working well for over 1 year. We came home from work and the temperature is 86F inside and climbing. My wife left the house at noon and the temp was 76F (where we keep the thermostat in the summer). The Air conditioner outside unit's fan is operating and no noise. The inside blower is running normal - no problem. The model number on the o


You have a 10 year warranty on your AC. Call a Goodman rep and have it serviced. It will probably be a bad compressor capacitor. Bad wire or no refrigerant. ... Goodman Air Conditioners

Installing 1 1/2 ton Weatherking Heatpump and ADP WAK351807P2 air handler 1 /1/2 with 7.5KW back up heat kit. Can't seem to get the thermostat hooked correctly. I understand the Weather King product reversing valve is different wired than other models. Color of wires on outside unit and inside unit don't match. Is there an easy wiring guide? I understand the R G Y W, but get hung up on the O B. Installing a Honeywell Digital non programable RTH3100C thermostat.


O energizes the reversing valve when the thermostat is set for COOL. B energizes the reversing valve when the thermostat is set for HEAT.The O/B is usually a orange or black wire.You can't hurt anything if you choose O or B incorrectly. H ... Weather King 10AJA6001AH Air Conditioner

I have a Goodman Air Conditioner Model CK49-1B. The fan in the unit does not turn on when the thermostate is set for cooling; the fan in the furnace works and blows warm air. Checking outside I discover that the dog chewed three wires that are coming from the unit. The repair person told me that the dog shortout the CONTACTOR and had to be replaced it, he also replaced 12 inches of wires damaged by the dog.. He did the job in less than one hour and charged me $225.00. Did he over charge me? Late


Take a look on amazon for same parts, and compare the prices: Amazon com goodman air conditioner parts. I hope this was helpful. Cheers ... Goodman CLQ36AR49 Air Conditioner

I have a Carrier whole house Air Conditioner I want to replace. It is model 38EN048320. @ things: 1. What "ton" is that AC rated at? It's so old I can't find what size it is so hard to pick a replacement. 2. With todays models they are all high efficency, should I get the same size replacement or can you step down a notch based on the efficency in models made today? I know a contractor would figure this all out but I'm doing this job myself as I have done this before.


1. 3 Ton Up To 4 Ton 2. You should get the same size - high efficiency means that for the same heat extracted from the residence the unit consumes less electricity than an older one. How much less is explained in the ratings: if your prese ... Air Conditioners

Hi, we have a problem with our Weatherking heating unit/ air conditioner. We had it installed 07/20/06. It really never has worked properly. For the last 2 summers in run's constantly. Which of course makes our electric bills outragous. Our house is around about 2200 square feet. This unit is a 4 ton unit. What could be the problem. Please help. Thank you. The model # is 13AJA48A01


Lets look at the whole problem. Did you have a new unit inside. Is the charge correct for unit. 1 lb of refrigerant makes difference. Four tons should be big enough if you have proper insulation. I have three tons in a 2100 square foot house. Its ple ... Weather King 12AJA4801AH Air Conditioner

Ge model agv12abg1 window air conditioner thermal overload cut's unit off after about 2 minutes, (unit get's extremely hot on outside right upper corner of the case), but will cool in approx 1 minute and the unit will come back on for another approx 2 minutes, any ideas?


Sounds to me as if the heater and a/c may possibly coming on at the same time causing too many amps to be pulled from the electrical box causing the overload to be tripping. You should also check to insure there is a clean coil. If there is a dirty ... Air Conditioners

Air conditioner is turning on etc air is coming out but is not cooling. On the display screen on the unit is a error code CH flashes then a 1 flashes. LG neo plasma inverted split air con. Model S24AWN-N56


Hello NaevaPlesae visit the link provided below :http://www.mylg.co.uk/data%20for%20site/Multi%20F_dx_%20Fault%20Codes%20-%20Nov%2007.pdfhttp://www.abacusairconditioning.co.uk/lg%20split%20codes.pdfhttp ... Air Conditioners

Goodman air conditioner model #PC036-1a; when you put on heat the unit kicks on and blows out air with no problems but when you try to turn ac on, you can hear the motor click on like it's trying to start but no air blows out of the vents. thought it might be the relay switch? any suggestions


Try replacing the control board most the time its a relay stuck open for high speed on your fan ... Goodman Air Conditioners

My Everstar portable air conditioner model# MPK-10CR-1 will not drain into the bucket that comes with it. It is draining into the tray at the bottom of the unit then the unit turns off when the tray is full. Can you tell me how to get this unit to drain into the bucket?? thanks robin


Simple I believe...just run a weed eater line up the whole in the back where you have the clear tube. You can take the little back door off the power cord area to see inside where the water drips into the little tray before it goes down the hose tube ... Air Conditioners

Bryant air conditioner - outside unit will not run - before it quit running, air temperature in house rose from 65 degrees to 75 degrees. Inside fan continued to blow - air smelled like a car air conditioner that ran out of Freon. Bought Freon - need to know where to add it. The heat pump model # BF-163S bi directional but also coming from unit is another line that runs same direction with same type of valves. Air conditioner model # 697CN030 - B


... Air Conditioners

Heat pump drawing too many amps - Goodman Manufacturing Goodman GSH130301 Air Conditioner 2.5 Ton 13 SEER Heat Pump R22 - Dry Unit


If you are over drawing amps on start up and the breaker trips then you probably have a locked or"sticky compressor. You can check this by looking at the sticker on the compressor it will have a rating called LRA(locked rotor amps). If it your amp dr ... Goodman Manufacturing Goodman GSH130301 Air Conditioner 2.5 Ton 13 SEER Heat Pump R22 - Dry Unit

Hi there! I have a five-year old GE standalone (not in the window) air conditioner model APE09AJM1. Never had a problem in the past, but now I do. The fan works fine. However, the AC is not working correctly. The fan will run for about 35 seconds, than the unit will buzz and make a clicking sound for 1 second while the fan slows down, and then the cycle repeats. Air is coming out, but it isn't cold. Suggestions?


Hi you have a compressor that is drawing locked rotor amps. It is trying to start for a second, drawing lots of amps, causing the fan to slow down because of this. It is shutting of on its overload protector. Thats why you have no cooling. It may be ... Air Conditioners

How many tons is a goodman model #CKL 49 -1 - Goodman Air Conditioners


... Goodman Air Conditioners

Out door unit model number PV-6YARD This model number Air conditioner howmutch Ton


Seems to be 1/2 ton. Please write which brand it belongs to and also indoor model also. If not write BTU. 12,000 BTU = 1TR. Thanks. ... Air Conditioners

I have a Goodman a/c unit,comes on and runs but no colld air. fins spin and blower doesnt blow cold air. model # ckl 42 - 1.


The first thing I would do is a visual on the capacitor. This time of year with more use the capacitor will swell up and fail. ... Air Conditioners

Do I only need a new condenser, or a whole new split central air conditioner system? I currently have a Bryant 340AAV with a Bryant evaporator coil model no. CD6AXW036021ABAA, outside I have a Goodman Condenser model no. CE36-1GB, My compressor has failed, HVAC said replacing compressor would not be worth it. I was about to buy a used Rheem 10 seer condenser, but I read that the minimum is 13 seer and that if the inside is a different seer from outside that would result in it breaking down. I do


Hello!The HVAC shop is likely accurate when they told you it would not be cost effective replacing a compressor alone. My advice is to contact the HVAC contractor back, and ask him what they would recommend that the condenser ... Goodman CKL42AR42 Air Conditioner

I have a Lennox, central air unit and I need to know if its a 1 or 2 ton. The model # is HS29-024-2P Hope you can help. Also how old is this unit? Thanks


Im 100 percent certain it is 2ton unit\015\012-024= 24,000 btu ... Air Conditioners