Having problems with your Air Conditioners ?

Replacing the thermostat, took the old one off without marking the wires. Hooked it up by color and we get the furnace when we put it on cool. wires are green, red, yellow & blue (ground wire)on the wall. The new thermostat wires are red, yellow & green. Can you tell me which wires go where correctly?


Answers :

The normal wiring for stats is white=w=heat,red=r=24volts,green=g=fan,blue=c=common,yellow=y=cooling.
\015\012see what ties into your furnace board and match the terminals.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Replacing the thermostat, took the old one off without marking the wires. Hooked it up by color and we get the furnace when we put it on cool. wires are green, red, yellow & blue (ground wire)on the wall. The new thermostat wires are red, yellow & green. Can you tell me which wires go where correctly?


The normal wiring for stats is white=w=heat,red=r=24volts,green=g=fan,blue=c=common,yellow=y=cooling.\015\012see what ties into your furnace board and match the terminals. ... Honeywell Air Conditioners

I have an older Carrier Heat Pump which I am trying to update the thermostat control with a Hunter model 44550. The problem is that the wiring to the current thermostat is as follows, G= green wire, R= red wire, W2= blue wire, O= orange wire, Y= yellow wire, E= grey wire and C= white wire. If I am reading the schematic correct for the Hunter thermostate I am to wire as follows Green to G, Red to RC, Blue to W, Orange to O, Yellow to Y/Y1, C cap it as batteries are used. It does not tell me


JUMPER STAYS BETWEEN RC AND RH SO YOU HAVE INCOMING POWER FOR BOTH COOLING AND HEATING. THE WHITE WIRE YOU SAID C IS COMMON AND SHOULD BE USED IF POSSIBLE TO COMMON TERMINAL ON NEW STAT . IF THERE IS NO COMMON, THEN CAP IT BUT YOU'LL BE CHANGING BAT ... Carrier Air Conditioners

Thermostat with 4 wires, red, green, white and blue; no yellow wire to connect to new thermostat


... Air Conditioners

I need the wiring diagram to wire a thermostat to the outside unit. Which wire goes where ? My Thermostat has four wires, green, red, white, and yellow. My Outside unit has three wires that are not connected ... a red wirte to a transformer, a yellow wire to what appears to be a relay, and a blue wire to the relay switch. Thanks.


The thermostat wires are this, Red is 24 volts hot, Yellow is cooling, Green is fan,indoor, and white is heat.The outdoor unit wires up to the indoor units terminal board, not the thermostat.The red will go to the R or red 24 volt wire at the furnace ... Air Conditioners

HONEYWELL RTH230B thermostat: we just installed the honeywell rth230b. The fan is working, but it's not turning on the outside unit. We pressed down on the thermostat slightly and it triggered the outside unit on for a split second, but it wouldn't stay on. After reading one of your forums, we disabled the blue wire, and made sure red, green, and white were in correctly. (we don't have yellow). Any ideas? The fan and vents are blowing cool air, but the house is 83 degrees and climbing (because t


Hello,what you have to do now from here is that check the capacitor if the maize i.e (wire)_ that pass current over to the compressor is well fix because this well the unit get is own supply to the over load then the relay sec ... Air Conditioners

I am replacing a white-rodgers thermostat with a blue wire connected to a terminal label '4'. The only other reference to a '4' terminal is in the honerwell installation manual which says that if there is both an r and 4 terminals on the old thermostat it was incompatible. I returned it for a ritetemp guaranteed to be compatible though I'm still not sure what to do with the blue wire. on the old thermostat the red wire goes to rc, the yellow to y, white to w, and green to g. Does blue just go t


Blue just goes to B ... Air Conditioners

I am replacing the a/c blower motor and capacitor. The old motor has 1 brown wire to the capacitor, 1 yellow wire to the capacitor (the yellow then loops from the capacitor over to the wiring panel), 1 green wire to ground, and a black wire that comes from the wiring harness from the wiring panel. The black wire is plugged into a small white box on the side of the motor that has a port with three places to plug in wires. These are labeled black, red, and blue, but only the black is there, no red


\015\012Motor Wiring\015\012Old Motor\015\012Brown wire is Start\015\012Yellow wire is run or Power\015\012Black wire is High Speed or Common\015\012The other two taps are speed taps, but you have a single speed ap ... Air Conditioners

Trying to reconnect an old thermostat. The wires on the thermostat are yellow, white and there is a jumper wire between two points. There is a G which I presume is ground. The wires coming in are white, red (hot wire)light green and dark green. The light green came from the ground on the thermostat I am replacing. Any sugestions as to where to make the connections? Thanks


G (green) = fan\015\012w (White) = heat\015\012y (yellow) = a/c\015\012r (red) = power\015\012\015\012Connect white to w terminal and red to r terminal on t-stat since we know they are right, then touch one green to red ... Air Conditioners

I have a tempstar with 6 wires. Green, Blue, Red, Yellow,White, and Orange. I am trying to install a White Rodgers 300 thermostat and letters are not matching up. The thermostat has G, A, RC, RH, O, B, Y, and W. I don't know where to hook the blue wire which was labeled C. Unless it goes to RC and the red goes to RH could you please help? Thanks


You need to verify the function of each wire with Tempstar then cross it with the WR stat. Call the techline if you need further assistance 18002842925. ... Dometic Rooftop RV Air Conditioner

I have a Trane Heater/AC unit no heat pump with a thermostat model 802AS32DAA that has seven wires. I am going to a five wire heating/cooling thermostat. What do i do with the two extra wires? old thermostat red wire-RC slot (24 V from A/C) white wire-W1 (???) yellow wire-Y (A/C Compressor) green wire-G (A/C Fan) black wire-B (?????) Blue wire-Y2 (????) orange wire-W2 (24 V to Furnace new thermostat therminals G Rc Rh Y/O W/B Y1 Can you tell me what wires to connect to each


From Honeywell : "If your old thermostat had Six or more wires, the replacement you have is Wrong!" ... Air Conditioners

I have a Janitrol Heat Pump Thermostat HPT-18-60 and need assistance connecting my new Honeywell RTH7500D thermostat I have a Goodman Heat Pump System Indoor Unit Model#AWB24-05C REV D Outdoor Unit Model#CPLE18-1 Here is the wiring of the old thermostat Y-Yellow Wire G-Green Wire R-Red Wire O-Orange Wire W2-White Wire E-Blue Wire C-Black Wire Where should each of these be connected to the new thermostats terminals?


... Air Conditioners

I have a Intertherm P3rA-042K that runs the ac at the same time as the heat strips. I have a Honeywell RTH3100c I have the red wire at R the Yellow at Y the Green at G and the W2 at aux. I had a jumper between Aux and E like the manual said but it makes no difference. Also for some reason it was hooked up before with a blue wire joined with the red at the unit and the blue going to B at the thermostat. I removed the blue as i saw no use for it and it still doing the same thing. The unit froze up


Red, green, and yellow should all be from AC unit. What other wires do you have there, and are they separate from red , green, yellow? ... Intertherm P3RA-042K Air Conditioner

I just replace a Honeywell T87F28733844 Thermostat with a Honeywell RTH221 Thermostat since then my the furnance will not produce any heat. I replaced the thermocouple, but still no go. The pliot light is lit, but still no go. The wires that went to the T87F are yellow, green red and blue. The RTH calls for a yellow, green, red, and white, with a jumper jack in the Rh Rc. The blower for the fan works, and the ac works, but not the heater


The heat circuit uses 2 wires to the thermostat one is the power from the transformer, and the other goes to the gas manifold.\015\012\015\012The Rh and Rc is probably the power for heat and cool, and this is where the red would attach IF ... Air Conditioners

I installed a Digital Thermostat to an Evaporative cooler. The pump runs for a few minutes and the Fan kicks on afterwards for 10 seconds and shuts off. What did I do wrong? Master Cooler Model MC63C 60htz Wiring from Cooler: Black, Yellow, Red, White, Digital Thermostat Black(Power), Black/Orange(Pump), White (Common) Yellow (High), Red (Low), Green(Ground)


Check to see if your Tstat has dip switches on the back they may need setting. Is your tstat programable? If so check settings. Rus ... Mastercool 67680 Evaporative Cooler Air Conditioner

I have a carrier air/heating unit with pump. It has 8 wires. Brown,blue, white, yellow, green, black, orange,and red. I'm trying to install honeywell thermostat. The wires from my unit are suppose to go into these honeywell (RTH3100C) thermostat slots. hONEYWELL WIRE SLOTS E Aux Y G O L R B C The only thing i have to go on is the wire colors from my wall which were not labeled or coded in any way. I am not sure about the model# of our unit because it is so old that the model# has faded away the


Turn the power off to the air handler. Open the control cover. Write down what color wires go together at the wiring terminal. All 8 wires are probably not used.\015\012Post the findings here.\015\012In most cases,\015\012E= brown-e ... Carrier Air Conditioners

Ruud contour acheiver 90 plus trying to replace bad thermostat with Nest there is a black wire which goes to a "V" Not sure if this is also a power wire? the other wires are red to 24 V; blue to 24 C; Green to G; yellow to Y1;White to w Any help to connect to Nest second generation thermostat?


... Air Conditioners

I need to replace an old Thermostat that just has 3 wires coloured Red, Blue and Yellow. The Honeywell THR830TUK Thermostat I have bought shows 5 wires on the diagram. I'm not sure which wire goes into which Terminal. Can you please advise? Regards Tim


The honeywell THR830TUK thermostat does not require a neutral as shown in the instructions.Connect the LIVE to terminal "1" and your YELLOW SIGNAL wire to terminal "3".Connect your EARTH (if you have one) to the EARTH connection on the top left ... Air Conditioners

I am replacing a white rodgers thermostat with a honeywell rth3100c. i have matched my wire as e (brown) to e w2 (white) o aux y (yellow) to y g (green) to g o (orange) to o l blank r (red) t r b blank c blank now i have a blue wire which was hooked up to the x1 on the old thermostat. where does this wire go?


Blue (C) or sometimes (B) should be your common wire. Look at your schematics and locate common. Your Brown wire is (E) and is emergency heat, white wire (W) is Auxilary Heat, green wire (G) is fan relay, red wire (R) is power, yellow wire (Y) is C ... Air Conditioners

I bought a Hunter 44155C programmable thermostat to replace my Carrier non-programmable one. The wiring on the carrier is: W- white wire O- no wire G- green wire R- red wire C- blue wire Y- yellow wire Where do I put each of these wires on the Hunter? My available locations are: G RC RH Y/O W/B Y1 Thanks, David Martin


Hello,You need RH/RCjumper together=red wire...C=blue wire...G=green wire...Y=yellow wire...W=white wire...O/B unused for reversing valve for heat pump.Hope that helps. : ) ... Hunter Air Conditioners

Changing from a Trane Weathertron Heat Pump thermostat to a Honeywell TH5220D1003. The Trane unit had a white wire, green wire, red wire, orange wire, yellow wire, blue wire and a tan wire. Where do they go on my Honeywell TH5220D1003


... Honeywell Air Conditioners

Replace thermostat Purchased a HUD home and some one took the thermostate with them when they left, carrier model 38byc048340, but I'm not sure of the wire color codes the wires i have are listed below. Does carrier have a standard color code for the thermostat? white yellow red brown green orange blue


Typical color codes in Florida are;\015\012white to W1 for heat\015\012yellow to Y for compressor\015\012red to R-RC-RH for power in\015\012brown to W2 and or emergency /auxillary heat\015\012green to G or Fan\015\ ... Carrier Air Conditioners

I'm installing a Honeywell RTH7600B programmable thermostat and replacing a Honeywell T87F2873. The new one calls for a Red, Green, White, and Yellow wire, while I only have a Red, Green White and Blue. How should I connect the new thermostat?


Every thing the same except take your blue wire and replace the yellow for it. So when you hook it to t-stat goes like thisRed to R White to WGreen to GBlue to Y ... Air Conditioners

Ceiling fan 3 speed pull chain KTE switch broken 4 wire L=BLACK 1=BLUE 2=RED 3=YELLOW All wires match fan colors except blue splices to a black. Fan is model EF200D UL E130543. Can u help with a correct KTE replacement switch? Thank You Billy


... Air Conditioners

I am replacing a White Rogers 1F58-77 with a Honeywell RTH2300. When I removed the old stat the wire colors are white, red, orange, green, yellow, and blue. G- green wire Y- Yellow wire R- Red wire W- White wire O-Orange wire X1- Blue wire I hooked up all the wires except the blue. Instructions with the Honeywell unit said not to hook up the blue wire if there is an orange wire to hook up which I did. The problem, when I light off the A/C (heat pump) the compressor comes on but the


Yes you did correct. Tape of f blue wire. On your thermostat you should have el/gas turn top el and fan should work Russ ... Air Conditioners

Rheem Model RQNJ-A042JK Heat Pump Unit wired to a protech 520 Thermostat. Everything OK in auto mode. Fan will not run in on mode. All wiring connected except orange and black. Do not have original manuals for either unit. Installer went AOL and out of business without leaving me the manuals. Anyone have a solution. I know that Rheem is notorious for their wiring color tricks and I do not want to screw something up. Here is the wiring as it is now: Red - R Blue - B Yellow - Y White - E Jumper -


Connect the orange to the o terminal.\015\012Dave ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific