Gibson air handler blower motor runs slow - Gibson Air Conditioners


Answers :

Change the fan capacitor.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Gibson air handler blower motor runs slow - Gibson Air Conditioners


Change the fan capacitor. ... Gibson Air Conditioners

Bryant plus 80 t blower motor running slow - Air Conditioners


... Air Conditioners

The model number as listed on the receipt is CKQ24. The Blower moter in the air-handler is not running. When the fan-only switch is turned on, the blower motor will attempt to spin by pulsing for about 2 seconds. It will repeat the pulsing cycle in about 2 second intervals. There is no smell of burning. When the unit is set to AC and auto, the evaparator coils do chill. The blower motor is a variable speed motor with an external ECM. How do I test the ECM and/or motor? What should I look for in


Personally I would get an exact replacement capacitor same voltage rating and microfarud rating. The capacitor will read something like 370v 5uf. I would be surprised if that's not the whole problem. If not it needs an exact evaporative fan replaceme ... Goodman CKL24AR24 Air Conditioner

Blower fan in the inside unit tries to turn on but wont. It can be turned manually and air conditioner comes on and runs fine. The " squirrel " cage spins completely freely and is not sticky or jammed. Is the motor bad or is it a run capacitor. Model number of inside unit is a49-15


\011Sound more like the cap, but if the motor is raging hot, it could be the motor, another thing it could is improper voltage although less likely. But Goodmans/ do have this weird fan relay issue were they just bite it some times. I wo ... Goodman Air Conditioners

My fan motor runs to slow and needs to be speeded up. The fan motor has been changed to a A O Smith. Air conditioner is a Goodman 3 ton.


AO Smith motor speeds are Red low Blue med. And black high. Just unplug from fan switch plug in new speed. Turn power of first. Rus ... Goodman Air Conditioners

Have a Payne pg8uaa furnace. Furnace only works when I run a jumper between R and W. Replace wiring to furnace. I suspect that the outside blower motor is the problem. When furnace is running the blower motor has a humming sound but does not blow air. At this point, I would like to know how you would diagnose a Tjernlund HSUL-J blower motor. Should the motor itself be replaced or should the fan prover be replaced?


You would have to test the motor as well as the capacitor on the motor capacitor goes for alot less then the motor though.here is the pdf manual on your blower h ... Air Conditioners

Motor runs but very very slow - Carrier 52FC0093 Air Conditioner


Your motor rpm less due to weak capacitor or winding weak. First replace capacitor and check. ... Carrier 52FC0093 Air Conditioner

Will a blower motor run on a weak capacitor - Air Conditioners


... Air Conditioners

Coleman EB23B heat pump: Air Handler Humming Loudly, Blower Runs


If you're mechanically inclined - and you seem to be - with all the stuff you've already done - you should be able to 'fix' this problem - if you decide to after reading what I have to say.\015\012\015\012First of all - the humming you he ... Coleman Air Conditioners

Rheem Air Handler will not run. This is a 2006 Rheem model RHLA-HM3617JA Air Handler. I replaced both the condenser and air handler circuit boards. I replaced the motor in the air handler.. The condenser works fine, the board flashes normal. The air handler board shows 0 volts on the X13Com brown lead,..28 Volts on the center, X13G green/black lead, 1 volt on the Bottom, Blue, X13SPD terminal. The 24VAC Terminal shows 27 volts. The 3 amp fuse is good. The transformer appears normal. I replaced


Have you hard wired your fan motor to verify that the motor and or the capacitor are good? If you do a continuity test of the motor leads(with electricity off of course) you can see if the motor has open or grounded windings. ... Ruud Handler Air Conditioner

Rheem Air Handler will not run. This is a 2006 Rheem model RHLA-HM3617JA Air Handler. I replaced both the condenser and air handler circuit boards. I replaced the motor in the air handler.. The condenser works fine, the board flashes normal. The air handler board shows 0 volts on the X13Com brown lead,..28 Volts on the center, X13G green/black lead, 1 volt on the Bottom, Blue, X13SPD terminal. The 24VAC Terminal shows 27 volts. The 3 amp fuse is good. The transformer appears normal. I replaced


We tried to bypass at the Tstat. Thanks for your time and interest. ... Air Conditioners

Blower motor in home air conditioner does not work


The most common failure for this problem is either the start/run capacitor or the fan motor. IF YOU ARE NOT experienced with electricity then I would strongly suggest hiring a technician. The volts are 220 with a potential of 50 amps in a common resi ... Air Conditioners

Hi I have got adouble storey house. I have moved into the house this year. My Fujitsu ducted air conditioner is not cooling well. I think the blowers are too slow. My model number is AOT60RPAGT. Cooling in downstairs is ok but upstairs in the bedrooms it is not good. When I put my hand close to the vents I can feel a bit of cold air but I think the blower is too slow. I have selected blower speed to max on the control panel but still it doesn't work satisfactory. Please advise. Thanks


... Fujitsu Air Conditioners

Air conditioner runs for a few hours and it works - it cools the house. Then it stops cooling - the fan still runs but it doesn't blow out cool air any more. It seems like it's overheating or something. It will blow out cool air if it has not been turned on in a while but once it's on too long it stops. I was told it could be the fan motor and the a/c guy changed the fan motor today but that didn't fix the problem. Now he says it might be the compressor or that I need a new system. I'm jus


The things I would check:\015\012Is the system properly charged with freon? Sytem may be overcharged.\015\012Is the compressor out on internal overload at the point of failure? If the overload isnt tripped and the compressor is having tro ... Air Conditioners

Sometimes, when the inside blower shuts down, the outside compressor and fan motor continue to run for some time. Other times, when the inside fan motor is running, the outside fan and compressor motors are not ... if I press the outside reset button, it starts up When both inside fan motor and outside fan and compressor motors are running, it works fine ... warm air blows out of registers. Other than that problem, both units work great!


Sounds like you have a dirty condenser. You are going to need to disconnect the power at the outside unit on the wall by pulling the fuse block out. Take a good look at the louvered covers that are attached to the outside of the unit. Remove the scr ... Ruud UAKA060 Air Conditioner

I have a Bryant 561C central air, 5 years old, The Motor on the outside unit of this air conditioner went out, trying to sve some money on a service call I ordered the new motor and put it in my self and was able to make it run but no cool air inside the house. The motor that I took out was made by General Electric with three wires coming out of it, now the new motor I bought was made by Emerson with 4 wires coming out of it, also the lady from the Bryant dealer where I bought the motor also sen


Hi there, \015\012\015\012here is the wiring diagram of you air con unit...\015\012\015\012http://w ... Air Conditioners

Blower fan motor wont start on carrier package unit air conditioner I have a Carrier 50ZPA042-301TP package unit


... Air Conditioners

Air Conditioning I have a ruud system with the air conditioner outside and the air handler upstairs in the attic. My systems appears to be running, and I can feel cold air at the vents, but I can barely feel it. Like there is no flow. The fan outside is running and the unit in the attic is running. I have no clue what the problem is. The large coil coming from the heat pump outside is cold and has condensation on it. It also seems to have a little ice. It has been extremely hot here in Ge


Open the access panel on the air handler in the attic and take a look at the evaporator coil. If you have no airflow, and you just changed the air filter, then you probably have a buildup of airborne crud on the coil that's blocking airflow. \015\01 ... Ruud UAKA030 Air Conditioner

Goodman air handler blower motor wiring


Purple goes to the transfornerthere is a double terminal and that is where it goes ... Goodman Air Conditioners

My air conditioner air handler humsbut moter does not turn on compressor runs ok Goodman air conditioner


Either bad motor ....or.... if you are lucky a bad run capacitor. you will need some sort of capacitor checker and multimeter to diagnose it further. ... Goodman CLQ36AR49 Air Conditioner

I have pane air handler, split sistem. When it runs air conditioner it also runs emergency heat at same time. If I tern the sistem off the emergency heat is still on. It blow worm air. How can I solve this problem? I changed kontrol board for new one, but it did not help. help me please...


You have a stuck relay.\015\012Locate the relay that powers up the heat strips and verify that it is closed when power is disconected.\015\012\015\012If it is, replace the relay.\015\012 ... Air Conditioners

Hi, just replaced the capacitor thinking that would solve the problem but it appears it did not. The motor outside would kick on the unit inside would kick on but the blower motor inside works sometimes and wont other times. Basically, the unit will work just fine all day then we notice the house is getting warm, check the inside unit and everything is running fine but the blower motor is not circulating the air. I have a goodman a30-10 unit. I read where some people said the relay could be bad


Turn off the power to the air handler(indoor unit). Remove the access panel. From the motor,trace the wires back to the fan relay. One wire will probably trace back to the incoming power terminal. The other is the fan relay. It could be intermittent ... Air Conditioners

Dometic 579 Series Brisk Air AC runs fine-blower still runs but every couple minutes it "kicks on and off" it will blow hot air and then cold air and continues to do this. Did not do this until we installed a new motor.


Sounds like it is skipping the motor I mean, I am assuming that it was replaced with the correct motor(rpms,hp,volts). As if it was not it will skip, like it is doing now. ... Dometic Rooftop RV Air Conditioner

I have a goodman ar24-1 blower motor that will not start. I have changed the capacitor, checked the thermostat, spun the blower motor but still will not start. Outside unit runs but no blower. Any ideas? This is a central air unit that is less than 6 years old.


Check the relay or sequencer that controls the blower if it has one of those. If the fan is controlled by a circuit board then you problem may be there. If it is controlled by a circuit board then you can check for power at the fan connection when th ... Goodman CKL24AR24 Air Conditioner

Hello, We bought a Perry Home in Georgetown TX last March and it is still under its two year warranty. Our air conditioner stopped cooling today. It has been working well for over 1 year. We came home from work and the temperature is 86F inside and climbing. My wife left the house at noon and the temp was 76F (where we keep the thermostat in the summer). The Air conditioner outside unit's fan is operating and no noise. The inside blower is running normal - no problem. The model number on the o


You have a 10 year warranty on your AC. Call a Goodman rep and have it serviced. It will probably be a bad compressor capacitor. Bad wire or no refrigerant. ... Goodman Air Conditioners