Having problems with your Air Conditioners ?

I have a goodman 5 ton a/c model gsc130601bc, it isn't cooling, keeps tripping main 60 amp breaker, blower is running at air handler. Tstat is calling for cool and contactor Is pulled in, it has a service breaker close to unit. I checked 80/5mfd capacitor with field meter, checks 79.5/4.9 mfd


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a goodman 5 ton a/c model gsc130601bc, it isn't cooling, keeps tripping main 60 amp breaker, blower is running at air handler. Tstat is calling for cool and contactor Is pulled in, it has a service breaker close to unit. I checked 80/5mfd capacitor with field meter, checks 79.5/4.9 mfd


... Air Conditioners

My air conditioner is blowing hot air instead of cool air.. what is wrong with it? a/c is blowing warm air. i checked the circuit breakers, all okay. check both fans, all okay. i pulled the filter, just a little dirty. i pulled the main panel off the unit and checked for a dirty coil, all okay. The unit is 2.5 years old and is suspended in the air in my garage. is there a clogged drain. should i get the bleach out? please help.


Check to see if you have power to the compressor. it my be a thermostate problem... ... Air Conditioners

NOT COOLING I AM HAVING A PROBLEM WITH THE UNIT. I HAVE WARM AIR BLOWING INSIDE, BUT WHEN I GO OUTSIDE TO CHECK THE UNIT THE FAN ON THE UNIT IS NOT RUNNING. I CHECKED THE BREAKER TO SEE IF IT WAS TRIPPED, BUT IT WAS FINE. I WENT BACK TO THE UNIT AND GOT REAL CLOSE TO IT. I CAN HEAR A LOW HUM NOISE AS IF POWER IS GOING TO IT, BUT THE FAN ON THE UNIT IS NOT TURNING. I PLACED MY HAND ON THE TOP CENTER OF THE UNIT, AND IT WAS REAL WARM. I DON'T KNOW WHAT THE PROBLEM IS. NEED HELP


A/c unit refrigerant charge is possibly low due to leakage, call a a/c engineer ! ... Air Conditioners

I have an Amana RHE30A2B heat pump. I installed a new thermostat, Honeywell, last night and now the coils are not cooling & the unit is blowing hot air. I have double checked all the wiring & everything seems to work as it should. Is there a breaker or fuse on the outside unit that I am not aware of before I call a service man out. We also had an electrical storm last night. It could be a freak thing, but I am still concentrating on the thermostat.


Hello,If you can hear a click or see a light when you turn your thermostat from up to down you do have power there. Or, you can put a meter on your thermostat and see if there is any voltage or not. If not in either case, you can try this ... Amana Air Conditioners

We live in southwest Florida. Our HVAC system consists of a air conditioning system with heating coils when it is cool. Yesterday morning we tried the heat nothing come on. Later in the day I tried the air nothing. I tried turning in just the fan nothing. I just checked the breaker I have power where the wires are connected. I went out to the outside unit and pulled the cover. Pushed in a spring loaded plastic switch the fan on outside unit works and shut off when I released the switch. But noth


Hello. Sounds like you do have power. That spring loaded plastic switch is a 24v contactor. It pulls in when energized. If you push it in manually everything shoud run normal. Ck your 24v transformer. On one side (feed) you should have 115v or 220v ... Air Conditioners

I have a duo therm a/c roof top unit that is not cooling properly it has been approx 2 years since the unit has been run I have checked breakers and fuses in breaker box I removed the cover from unit the compressor is running and getting hot the lines are cool but not cold the fan is running I am thinking that the unit is low on freon can some type of self tapping ports be installed to add freon or have ports soldered in place or could there be another underlying problem that can be checked or i


You have a leak in the system that needs repair. If you have to add freon to system there is a leak. You need a service tech to do the repair. If it is out of gas you may to replace it. Leaks do not correct themselves. Russ ... Dometic Rooftop RV Air Conditioner

AC Out. Two year old house. Goodman A/C, two units one for upstairs. Cleaned coils of both outside unit, replaced filters, re-set breakers. Upstairs is cooling. Downstairs unit is running outside, not circulating air inside (inside temp 87). Vents inside are cool to touch, no air. Outside unit fan is pulling, but air exhaust is cool. Compressor ? Should air be circulating even if compressor not functioning. Is there anything in attic exchange that would affect downstairs circulation. Thanks.


Assuming that the 2 systems are isolated, that there isn't any cross over between the systems...It is normal for an air conditioner system, from window unit to central, to be able to circulate the air, even if not cooling. This is known ... Air Conditioners

57915-341G9 AC. unit is tripping the 20amp breaker intermittenly. while unit is running it is pulling between 13 and 17 amps on high cool. then the compressor will drop out pulling 2.5 amps then it will spike up to 39 amps until the breaker pops. reset it and it will work fine sometimes and then start again.


Sounds like the compresser is bad,I have seen a freon overcharge also do this-but it is rare. ... Dometic 57915531 Air Conditioner

Goodman heat pump model CPKJ421B. Tripped breaker for outside unit two weeks ago. Reset breaker, tripped again today. Unit won't run now. Did some basic checks and found that the 28 vac from the inside unit was not going through the low pressure switch to pull in the 220 vac contacter for the compressor. Possibly either the refrigerant is low or the low pressure switch is bad. Could a faulty switch, maybe losing and regaining contact quickly, trip the breaker? Could the refrigerant, just before


... Goodman Air Conditioners

Ac was not cooling very well,breaker was hot -turned off-reset breaker-ran and cooled good, but would not shut off,the remote would not work-turned breaker offto stop unit -Now nothing works,manuel controls or other wise,breaker checks ok ,it is incorporated with hot water heater,which is 15 left side,ac 20 amp breaker right side.


Turn the breaker on and remove the cover from the A/C and check for proper voltage coming into the unit. If you don't have it the circuit breaker may be bad. If you do have it, set the thermstat to make the A/C try to come on and check the contactor ... Dometic Rooftop RV Air Conditioner

Hi, I have a samsung aqv18ja series split type air conditioner (cooling and heating) wall unit. the unit was install in 02/12/2009. By "one hour heating and air conditioning". In this short time service the outside compressor has been replace, the system has check and recheck,for cooling leak. the inside unit fan motor has been change. but the problem still exists. The inside unit fan continues to run when the unit is "off" and with the remote off.


Simple, check in your remote. There is an option button "Blow". Just press it. Your unit gets completely off. Please write back if helpful? ... Samsung Air Conditioners

I'm not sure about the Trane brand, but I'm having a hard time finding Armstrong service information and I was told this was a "Trane" I believe, or possibly a Ruud. I have a "combo pack" 3 ton heat/air unit. It quit working late summer, and I haven't had much time to look at it. It was totally dead, and I checked the main breaker service panel, none tripped, the fuse block on the house, both fuses were good. Opened the service panel on the unit and found one of the 120 volt "hot" leads had be


Okay, \015\012Yes this did get lost... Fixya was having toruble getting theri emails thorugh yahoo so I have changed my email to gmail and am getting notices again...\015\012\015\012Now, as far as fixing that....\015\012 ... Air Conditioners

Earlier this week, I noticed that the house felt "stuffy" but the thermostat showed everything to be cooling as expected. Last night, the house was definitely warmer than expected when we got home. My husband did some checking and found that the outside unit was running as normal, but there was no cool air coming through the vents inside the house. turning the a/c unit off at the thermostat did NOT turn off the outside unit...was only able to do this at the circuit breaker. It seems that the fan


If both fans runs (inside and outside), check if the compresor runs , if does probably the unit is low in freon and needs to be recharged after the freon leak has been fixed (remember this is a seal system and it shouldn't leak), but if the compresso ... Ruud UBHC Air Conditioner

Earlier this week, I noticed that the house felt "stuffy" but the thermostat showed everything to be cooling as expected. Last night, the house was definitely warmer than expected when we got home. My husband did some checking and found that the outside unit was running as normal, but there was no cool air coming through the vents inside the house. turning the a/c unit off at the thermostat did NOT turn off the outside unit...was only able to do this at the circuit breaker. It seems that the fan


Nope, nope, sounds like a stuck contactor in the electrical compartment of the condenser, but there are actually several things that could cause it. ... Air Conditioners

I have a Duo Therm Quick Cool, model 59516331, mounted on a 2001 Dutchman. With the A/C on it cools great but the compressor does not kick out or cycle. The unit runs until it freezes and can't blow air. When I shut the unit off manually from the thermostat the compressor continues to run, the only way to shut it off is to shut the breaker off. I am wondering if it could be the thermostat? I have checked everything I can think of. Any advice for me?


... Air Conditioners

Not Cooling When I checked the unit outside, the fan is blowing cold air. Both, the unit inside and outside are runing well, but air flow in the house is not cooling. I took a look at the breakers, but they are fine as well. Can this be the compressor?


Yes, the compressor might not be running. Possibly a bad run capacitor or maybe burnt wires on the contactor or compressor flags. ... Weather King 10AJA3601AH Air Conditioner

A/C not coming on. The thermostat is set properly to cool, the temp to 67. However, on the interior fan runs and it does blow cool air but seem weak. I went outside to the A/C unit, and nothing is moving. I checked the circuit breaker and the exterior fuse box, but nether are tripped. The A/C unit is a Goodman SSX 16 series.


Hi,You can use this link.(inspectapedia.com/aircond/aircond1123.htm).Hope it helps. ... Goodman Air Conditioners

Interkool 900 stopped cooling - what to check before calling for service? The unit has worked fine for 4 years. The fan runs, but the unit does not cool the wineroom anymore.


T seems like there is a problem with the thermosat, or the compressor. Its not sensing the temperature being to warm to kick the compressor on and cool it down. OR the compressor itself id dead. Hope I could help.\015\012 \015\0 ... Vintage Keeper Interkool 900 Air Conditioner

I have a suburban lp furnace and duotherm air/heat pump roof unit. duothern thermostat. 20 amp breaker kicked ( reset breaker) & furnace quit. NOW furnace fan comes on but does not light, and the front AC will not work either, when in the COOL position on STAT the unit blows warm air instead of cold. I replaced the Thermostat and a Tech guy checked the board in the furnace and it was OK. He also switched the board from the rear air with the front and nothing changed. Rear air and heat pump works


I'm not sure what the problem may be but you could try calling All\015\012Seasons RV Appliance Parts & Service. There number is\015\0121-800-344-0673 they have helped me in the past. That and there tech\015\012calls are free so it wouldn't hurt ... Dometic Rooftop RV Air Conditioner

Had a ac tech service central heating unit for the fall. Tech left and I left to do some errands . Now AC unit is not cooling its blowing warm air. I turned the circuit brks off and on inside and outside. I have also checked to see if unit was left on heater. thats not the problem. If I turn theAC on the fan does not turn on outside and there is no sound coming from the unit outside HELP!!! AC was working properly before this.


It may not help but it sounds like the tech took a control wire for the cooling circuit loose at the indoor air handler/furnace so that he could bring the heat on to check it, and forgot to hook it back up. That may not be the case, but if it is it w ... Air Conditioners

We changed the AC unit from putting out cool air to warm air and several minutes later there was a loud "pop" sound and the whole thing stopped working.... I checked the breakers on the side of the unit and only one of the two were tripped. I reset it and still nothing... powere is getting to the unit. UBHC horizontal in attic. Thanks


Hi there,\015\012 it sounds there is short circuit when you switch on your ac,\015\012resulting to trip off,you can also check the over load relay on control panel,there is a lever to reset on thermal relay of the circuit\015\0 ... Ruud UBHC Air Conditioner

My ac unit will not go below 77 degrees. It quit working about 1.5 weeks ago, and I had a service technican come and look at it. He replaced the capacitor and the unit started back up and would cool to 75 degrees (where I usually have it set). He checked the pressure of the unit as well and said that it was fine. However I came back from a trip and the thermostat read 77 degrees even though I have it set on 75, and the temperature will not go any lower. This is the same thing it was doing


Hi, It sounds to me like you have covered all of the basis. The evaporator coil should be clean if you keep your filter clean and the condensation is showing that it is cooling properly. Normally, when the temperature increases outside, you will loos ... Air Conditioners

Carrier Comfort 13 Puron model 24ACA3 / FV4NB006 installed 3/18/08 no longer cooling. Carrier AC1-100 Thermostat checked per manual - all default settings intact. Test override did not turn unit on though. All systems turned "on" - circuit breaker "on". Noticed last night that room temperature was rising so we turned target temperature down. Usually room temperature and target temperature are within a 1 or 2 degree swing. System did come on & cool once last night. Today though system is not comi


Verify 24 volts at the low voltage transformer inside the air handler.\015\012If it is OK, jump out the red/green and yellow thermostat wires. If everything comes on, replace the thermostat. ... Carrier 38CKC036 Air Conditioner

I have an american standard air cond. unit outside...I tried to turn it on yesterday and it comes on in the house but no cool air...on the outside the unit is not on, fans not turning etc. checked the breakers inside they are on.....what can I do to troubleshoot. I'm tired of calling the original guys who installed it. I have to call with every season change...winter, summer, winter, summer. I do remember last time I called they replaced something that if I paid extra which I did I could get the


Installed a new controller now nothing works.Marked wires as I removed then from the old controller and installed then into the proper connector on the new controller. Reinstalled old LUX controller and still nothing works. All circuit breakers ... American Standard WCZ036F Air Conditioner

I have a Dometic 15,000 btu, ducted air conditioner in my 30 ft fifth wheel. It seems like the unit has never cooled very efficiently. Dealer has checked out. I noticed yesterday, outside air over 100 degrees, that the air conditioner would put out good flow of cool air, but once in a while compressor would stop running even though not close to thermo setting. Fan would continue running. Any suggestions?


Not sure what the pressure sensor should ohm at but i would suspect a faulty sensor if everything else checks out. Its very common for these sensors to exhibit issues when they get hot. Also you may have a filter in the system that may be restricte ... Dometic Rooftop RV Air Conditioner