Having problems with your Air Conditioners ?

I have a goodman air conditioner model # CK30-1T, is this a 1 ton unit


Answers :

2&1/2 ton unit

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a goodman air conditioner model # CK30-1T, is this a 1 ton unit


2&1/2 ton unit ... Goodman Air Conditioners

1990 Goodman air conditioner model CE36-130 is it a 3 ton or a 2.5 ton unit?


3 ton 25 years is great service for a/c ... Goodman Air Conditioners

What ton rating is model number CK30-1B - Goodman Air Conditioners


2&1/2 ton. ... Goodman Air Conditioners

Evaporator Coil I have a Goodman A/C system (2 systems...1 for 1st floor, 1 for 2nd floor). The one for downstairs is 3.5 ton. the one for 2nd floor is 3 ton unit. Installed when house was built 5 1/2 years ago. The upstairs unit has had the evap coil replaced once, and repaired a leak once - 6 months ago. The downstairs unit has had the evap coil replaced twice -and is now leaking again. Model for the air handler is ARUF042-00A-1A. Goodman part# for the coil is P140142. Can I replace this coil


Yes, just count how many pins per inch and replace with the same number of pins per inch. ... Air Conditioners

My son has a Goodman Manufacturer Corp Heat Pump/air conditioner. Forced air I believe. The air conditioner quit. A repairman indicated that in order to replace the air conditioner the furnace will have to be replaced also. The air conditioner unit outside is Model No. CPE30-1-AB. Any thoughts?


I don't see any reason to change the furnace unless it's an air handler and not a furnace with a coil on top or bottom. And then, the only reason to change the inside unit when you change the outside unit is because it's a R-22 system and your going ... Goodman CKL30AR30 Air Conditioner

Details I have a problem with a Goodman Model GSH130601AA, ( 5 Ton, 13 Seer heat pump) central air unit, installed 06/15/2006. (I know, I saw online reviews but unit was put in before I saw negative e


The fan motor is bad and needs replaced. Depending on how mechanically inclined you are, you can replace it yourself fairly easy, the hardest part being the fan blade without a hub puller. Just take your old one in with you to a local A/C supply stor ... Air Conditioners

I have a Goodman 2.0 model no. ck24-1B and would like to change it to a 2.5 Ton 13 SEER R-410A Air Conditioning Condensing Unit. My furnace is a Goodman model # GMS8, GDS8 or GHS8 are they compatible


If it is a 410a system now you would have to change orfice. if its a r22 system now no way. ... Goodman Air Conditioners

I have a Goodman Air Conditioner Model CK49-1B. The fan in the unit does not turn on when the thermostate is set for cooling; the fan in the furnace works and blows warm air. Checking outside I discover that the dog chewed three wires that are coming from the unit. The repair person told me that the dog shortout the CONTACTOR and had to be replaced it, he also replaced 12 inches of wires damaged by the dog.. He did the job in less than one hour and charged me $225.00. Did he over charge me? Late


Take a look on amazon for same parts, and compare the prices: Amazon com goodman air conditioner parts. I hope this was helpful. Cheers ... Goodman CLQ36AR49 Air Conditioner

Goodman air conditioner model #PC036-1a; when you put on heat the unit kicks on and blows out air with no problems but when you try to turn ac on, you can hear the motor click on like it's trying to start but no air blows out of the vents. thought it might be the relay switch? any suggestions


Try replacing the control board most the time its a relay stuck open for high speed on your fan ... Goodman Air Conditioners

Hi, we have a problem with our Weatherking heating unit/ air conditioner. We had it installed 07/20/06. It really never has worked properly. For the last 2 summers in run's constantly. Which of course makes our electric bills outragous. Our house is around about 2200 square feet. This unit is a 4 ton unit. What could be the problem. Please help. Thank you. The model # is 13AJA48A01


Lets look at the whole problem. Did you have a new unit inside. Is the charge correct for unit. 1 lb of refrigerant makes difference. Four tons should be big enough if you have proper insulation. I have three tons in a 2100 square foot house. Its ple ... Weather King 12AJA4801AH Air Conditioner

Bryant air conditioner - outside unit will not run - before it quit running, air temperature in house rose from 65 degrees to 75 degrees. Inside fan continued to blow - air smelled like a car air conditioner that ran out of Freon. Bought Freon - need to know where to add it. The heat pump model # BF-163S bi directional but also coming from unit is another line that runs same direction with same type of valves. Air conditioner model # 697CN030 - B


... Air Conditioners

Out door unit model number PV-6YARD This model number Air conditioner howmutch Ton


Seems to be 1/2 ton. Please write which brand it belongs to and also indoor model also. If not write BTU. 12,000 BTU = 1TR. Thanks. ... Air Conditioners

Goodman 5 ton outdoor unit want come on - Goodman Air Conditioners


Check contactor on outside unit. ... Goodman Air Conditioners

Heat pump drawing too many amps - Goodman Manufacturing Goodman GSH130301 Air Conditioner 2.5 Ton 13 SEER Heat Pump R22 - Dry Unit


If you are over drawing amps on start up and the breaker trips then you probably have a locked or"sticky compressor. You can check this by looking at the sticker on the compressor it will have a rating called LRA(locked rotor amps). If it your amp dr ... Goodman Manufacturing Goodman GSH130301 Air Conditioner 2.5 Ton 13 SEER Heat Pump R22 - Dry Unit

How many tons is my Kenmore Central Air Unit - Goodman CKL60AR60 Air Conditioner


You can tell by the model # ... Goodman CKL60AR60 Air Conditioner

GPH1360H41 SCHEMATIC DIAGRAM - Goodman Manufacturing Goodman GPH1360H41 Air Conditioner 5 Ton 13 SEER All-In-One Package Unit Heat Pump


... Goodman Manufacturing Goodman GPH1360H41 Air Conditioner 5 Ton 13 SEER All-In-One Package Unit Heat Pump

Goodman ck49-18 is this a 4 ton unit? - Goodman CKL49AR49 Air Conditioner


Looks like a 4-ton ... Goodman CKL49AR49 Air Conditioner

How many tons is a goodman model #CKL 49 -1 - Goodman Air Conditioners


... Goodman Air Conditioners

Can a Goodman AC unit with a model number of a 24BTU-2 ton unit be upgraded to a 3 ton unit by changing the piston and the settings on the blower? They are also going to install a 3 ton compressor outside. Would this provide the same cooling capacity and performance of changing the actural HVAC unit to a 3 ton unit and would Goodman give me directions stating as much?


They would need to change the coil indoors to a 3 ton. If the blower speed can be increased it should be fine. ... Air Conditioners

3 ton unit compressor dont wnat to start - Goodman CLQ36AR49 Air Conditioner


There is a capacitor connected to the compressor and one connected to the fan ... the capacitors are used to start both (called starting capacitor) ...if its bad then the compressor/fan may buz but not start ..it will kick out once it gets hot .. tha ... Goodman CLQ36AR49 Air Conditioner

I have a goodman 5 ton a/c model gsc130601bc, it isn't cooling, keeps tripping main 60 amp breaker, blower is running at air handler. Tstat is calling for cool and contactor Is pulled in, it has a service breaker close to unit. I checked 80/5mfd capacitor with field meter, checks 79.5/4.9 mfd


... Air Conditioners

What should the psi be on 1 1/2 ton ac unit? - Goodman Air Conditioners


On r-22 should be 68-74psig on high side 230 to 260psig depending on heat load and ambient temperture ... Goodman Air Conditioners

Goodman ac unit model ck30-1a is not blowing cold air then the fan just stopped


... Air Conditioners

PCK048 Goodman Central Air Conditioner Unit Model Number PCKD48-1 or G0182770080 or PCK048-1


... Air Conditioners

What type of capacitor comes with a 5 ton Goodman Air conditioning unit model number CK60-1C


The best way to know what size capacitor it needs is to look on the label of the fan motor itself. It will tell you the size it needs. Condenser fan motors get replaced all the time with different capacitors needed. If you cant find a label or its to ... Goodman CKL60AR60 Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific