Having problems with your Air Conditioners ?

Carrier 38CK036330 Hi,  I totally know nothing about air conditioning. It's getting so hot in LA and we really need help since our house has a 18-month old child. We have a Carrier 38CK036330 central unit, and it's not cooling the house as we'd like it to. It's already about 13 years old and we are looking for a new one to replace it. The question is we cannot find this model anymore, or do we have to replace it with the same model?? What model or brand would you suggest for a 1350 square feet h


Answers :

The model numbers change.You have a 3 ton system.The make and model that you replace it with is not nearly as important as a quality install.Do your homework on picking a contractor that you can trust.Have them do a load calculation to make sure a 3ton system is right for your house.13 seer is the minimum you can get.You need to weigh the projected annual savings of higher seer units against the added cost of having them installed.Again,get a contractor you trust and go with the best warranty.None were stupid questions.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Carrier 38CK036330 Hi,  I totally know nothing about air conditioning. It's getting so hot in LA and we really need help since our house has a 18-month old child. We have a Carrier 38CK036330 central unit, and it's not cooling the house as we'd like it to. It's already about 13 years old and we are looking for a new one to replace it. The question is we cannot find this model anymore, or do we have to replace it with the same model?? What model or brand would you suggest for a 1350 square feet h


The model numbers change.You have a 3 ton system.The make and model that you replace it with is not nearly as important as a quality install.Do your homework on picking a contractor that you can trust.Have them do a load calculation to make sure a 3t ... Carrier 38CKC060 Air Conditioner

I have a Carrier whole house Air Conditioner I want to replace. It is model 38EN048320. @ things: 1. What "ton" is that AC rated at? It's so old I can't find what size it is so hard to pick a replacement. 2. With todays models they are all high efficency, should I get the same size replacement or can you step down a notch based on the efficency in models made today? I know a contractor would figure this all out but I'm doing this job myself as I have done this before.


1. 3 Ton Up To 4 Ton 2. You should get the same size - high efficiency means that for the same heat extracted from the residence the unit consumes less electricity than an older one. How much less is explained in the ratings: if your prese ... Air Conditioners

I have a Carrier model # 58MXA080-F-15112. I think my furnace is 30 plus years old. it isn't heating properly. The blower turns on and sometimes the flames come on, but sometimes they don't. As a result, the temperature just keeps dropping and dropping in the house. A furnace repair technician has been out twice. The furnace was displaying code 13. He replaced the limit switch and a another switch, but I'm having the same problem, but with no current code on the furnace. Any ideas?


A 13 code means the furnace cycled on limit more than three times consecutively and is in a lockout for 3 hours. A 14 is ignition lockout. An ignitor does not intermittently quit working. I'm the service mgr at our shop, and I know that particular fu ... Air Conditioners

I have a 10-year old Carrier Gas pack Model #48GS024060301. Turned on the heat for the first time this season and the unit did not turn on. I was able to turn on the house circulation fan and since it was a warm day today I also tested the A/C side and it worked fine. The inductor motor and fan were replaced last year. All the fins on the fan blade basically flew off on the first start up attempt last year. The entire unit, heating and A/C, were serviced within the last year by a certified p


If the induction motor ain't going I would look for a blown 3 amp (purple) fuse on the control board. If that was good I would check if any of the roll out switches were tripped. If a rollout switch was tripped check or air restrictions somewhere. ... Air Conditioners

I currently havea honeywell thermostat model# T8112D1005 (1) 0347 PF2A and a replacing it with a Honeywell TX1500E. My only issue is my old thermostat has a "R" wire that was connected up to it and my new unit only shows two options "RH" and "RC" it does not have an output of only "R". My question is where do I hook up the wire marked "R" from my old unit or do I even hook it up? The instructions mention if replacing a TM-11 to tape off the R wire and hook up the B wire to the B terminal. Im nit


... Honeywell Air Conditioners

All I need to know is this: The Chronontherm III died (my house is 20 years old and I believe it was original to the house) and I need a new thermostat. Can I replace the Honeywell Chronotherm III with the Honeywell model RTH221B? I'm looking for one that will be easily changed - hopefuly just pop it in place of the old one...


Hi,\012Yes, you can replace with that...just make sure that you mark the wires BEFORE removing them...so you can place them on the same terminals on the new t-stat...Here is a list of each common terminal and what their common ... Air Conditioners

I've had to replace the blower motor on an old GE electric furnace three times in the past year. The first time the motor just stopped working. So I replaced it with an A.O. Smith motor for the summer. It worked just fine during the summer. Winter comes along, switch the thermostat to heat and the house fills up with light smoke with a smell of burning plastic. I replace it again with the same brand and model # along with a new capacitor. It ran fine for about an hour or two, then it began to bl


This is definately not a good thing. This unit is a safety hazard to say the least. Check for recalls by reporting it to the consumer product safety. ... Air Conditioners

I have Bryant HRV and the motor has failed. I have received a new motor but there are two extra wires on the replacement motor. Below I have described the wiring diagram from the original motor with the replacement motor following. My question is - do the two additional wires need to be connected? The VRV unit is a Model VB5AAB015 and the serial number is 0494V00006. This unit was instaled in my house in 1994. the original motor is a Fasco No 7190-0921 and the Type is U90B1 The connection diagra


Wire nut and tape the blue and red wires they are not used. ... Carrier Air Conditioners

CARRIER AIR CONDITIONER/HEAT PUMP PROBLEM WOULD NOT RESPOND TO THERMOSTAT. UNIT IS AT LAKE HOUSE WHERE WE DO HAVE BAD STORMS. IN CHECKING, INSIDE PART OF UNIT HAD BURNED UP THE TRANSFORMER BUT NOT BLOWN THE FUSE. REPLACED TRANSFORMER . . . COULD SMELL AND THIS TIME TRANSFORMER STARTED TO MELT AND BLEW FUSE. SOMETIMES THE FAN WOULDN'T EVEN COME ON WHEN JUST SWITCHED FAN "ON" AT THE THERMOSTAT. QUESTIONS: WHAT WOULD KEEP BURNING UP TRANSFORMER. WE REPLACED WITH EXACT TYPE THAT WAS ORI


What I have always been told is if your 24 volt side burns out check the high volt side if the hi volt side burns out check the low volt side.A quick way if the primary side is burningout due to a problem with the low volt side:1 MA ... Air Conditioners

Rats ate wires in rv carrier 13.5 ducted ac. Replaced all chewed wires. fan turns on runs a few minutes When compressor kicks, Lights in trailer flicker and breaker pops In house. I have a 30 amp outlet installed jack on my house to plug trailer into. Breaker does not always pop In trailer. However there Is no ac what could be the problem? trailer mckenzie starwood bunkhouse 29 ft. It's not even 2 years old. Any advice would help. Blue wire was chewed the worst. I believe It runs from the copaci


You need an electrician be careful ... Air Conditioners

Boiler doesn't fire up. 25 years old Amana outdoor boiler model #3612M-A Mfg # P68191-1F,It had leak in pump housing and replaced, replaced igniter ,but no fire, no leak in system ,pump are keep running How to remove air from system and why it doesn't fire up , like to have step by step diagnosis chart Thank you.


Have a look at general maintenance tips below\015\012Boilers Inspection and Maintenance Tips ... Amana Air Conditioners

Hi All, I have a carrier reverse cycle airconditioning unit and about a week ago the digital thermostat blanked out. I spoke to an aircon repair tech and he suggested that the fuse is blown at the air handler and suggested that I can probably replace the fuse myself. My question is where is this fuse located in the carrier units, do I have to open panels or is it in a box like a fuse box in a car. I have no issues checking the fuse if I know where to find it LOL, The model of the unit is


It will be inside the unit main panel. Turn main power off and remove the main front panel. The fuse will be located on or near the fan control board. Typically they are a flat agc type fuse. 3-5 amps. The problem will be that if the fuse is blown ... Air Conditioners

In Dec 07 I had a complete Carrier AC/Gas Heating System installed in my home to replace my original system when my house was built in 1983.We upgraded the new system to 3-TON AC as the old AC was 2 and half ton. Since the new system was installed in the winter time it was not until the hot weather started in May that a problem arose. The first conclusion of the problem was that the coil was aligne incorrect the second was that we needed more air return so an addition vent was added. No


Air conditioning requires 400 cfm (cubic feet per minute) per ton of cooling so your old 2.5 ton system would have required 1000 cfm and your new 3 ton requires 1200 cfm. This is not a big change, but if your ductwork is too small it could cause pro ... Carrier Air Conditioners

I just need to know how to install this in an old house to replace a ceiling fixture and install a ceiling fan without having to make a huge hole in my ceiling. I can't find any instructions on the model 22200 that I would like to purchase.


If you're trying to replace a light fixture with a ceiling fan. The most important thing is to make sure that the electrical box in the ceiling can support the weight and momentum of a ceiling fan. If it's an old house, as you say, I suspect it's not ... Air Conditioners

Bought used Quorum fan Model HC 1990-CD will replace old Hunter fan. Question about wiring, control by chain only leads from fan white, blue, and black. Hard to pick the right expert Electrical


... Air Conditioners

I have a Carrier Airconditioner split system unit which I purchased in 1995. The model number is 42KNL018703. Can you tell me what kw output this is. I want to replace my current airconditioner with a similar output as it is now 15 years old. I am thinking a 7.0 kw output will do.


How much do I have to pay for a field power supply conn in my split system air conditioner carrier ... Carrier BCA101R Air Conditioner

Hi, I have a LG NEO PLASMA S18AHN SPLIT UNIT, It was already installed in our house upon us purchasing it, it would be approx 3 years old, has been pretty much running 24/7 and has been great up until recent, about 6months ago it stop and displayed the C6 error code, at this time I replace the external units motor start capacitor, it ran perfertly again for the next 4months, until it stopped again and again after reseting. When trying to run on Heat it comes straight up with "Defrost Mode" it


My lg 18 000 btu split neo plasma is on heating in any mode u put it\015\012what do u think is the problem ... LG Air Conditioners

I have 2 questions. I have a model # M6d18E7A-E Maytag window unit air conditioner and only the lights will come on. (no motor, fan, Nothing) I cant remember how old this unit is so is it worth fixing or should i replace it?


Hello. I can help you. The truth is that this is an old, inefficient unit. Replace it with a new energy saving model and you will be money ahead by the end of summer and a lot cooler. ... Air Conditioners

Changing filter It's winter time. I want to change the filter on my Carrier Weathermaker 8000. How do I do this? Is there anything else I should do? I just bought the house and wonder what should I do to the furance. Should I call someone and have it serviced? How old is the unit? When should it be replaced? Thank you for all your advice. [email protected]


The filter should be located in the return air flow duct either inside the furnace or in the ductworkyou should have it inspected by a service contractor as far as when it should be replaced depends on the condition of the heat exchanger ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

I have an old Fedders thermostat model CNX 110 T3B an am attempting to replace it with a programable thermostat. My question: Does the wire terminal marked Y-C control the compressor?


Yes y is for the compressor and c is for the common ... Fedders Air Conditioners

I have an 8 year old 2 1/2 ton carrier compressor unit. I have already replaced the running coil and contactor. I now want to clean the coils and fan blades on the motor. I have never had reason to remove the top grill. I looks as though the fan motor is attached, and I don?t want to do anything stupid ?if I can help it? or damage or disconnect any of the wires. what is the proper way for me to access the inside of the unit so as to be able to spray off any debris that may be on the coils. So fa


Hey Bernie, it is possible to remove the 4 screws on the grill that the motor is mounted to (not the bolts holding the motor to the grill)and pull up and twist so its upside down and have someone else hold it as to not put to much stress on the wires ... Carrier 38CKC042 Air Conditioner

I need to know what are the specs for (BDP Co.) Carrier Corp. Model 5410 1024, it is an old High Efficiency Heat Pump; maybe from the early 80's, I need to replace it and need to buy one of the same capacity


2 ton ... Air Conditioners

Carrier package heat unit Model 50TJ-006---600 Unit is around 20 degrees and at 425psig on the high side...frost lines on the evaporator coil...high is super hot and the suction line is mild...no cooling inside. Unit is 14 yoa...restriction is there, we have already removed the screen and replaced the high side dryer


Dear sir \015\012 we need sugation for this we having prob with compressure Crrier Package unit model no : 50TJ16-028B/S We having little Diffreance with power supply (each phase.like a Red is 217v ,yellow is 218v Blue is 221v ) is there any proble ... Carrier 50TJ028 Rooftop Electric Cool Air Conditioner

My house had a power surge and now my inside fan will not come on. It is a frigidaire heat pump 3 years old. Model # b5bm-t49k-c 4 ton unit. Outside unit is ok. i replaced the circuit board but still have the same problem. It is a 13 cer unit? i have 220 volts at the motor but unsre how to verify if it is bad. Any ideas would be appreciated


... Air Conditioners

Goodman heatpump model cpke30-18 installed new in 1997. just replaced the condenser motor. new fan runs cloclwise but the fan blade is for counter clockwise. it is blowing down not up. part house said that i have the correct part. old and new parts do match up. has three wires yellow - cap, black-motor starter and purple to control board. is there any was to change direction of motor. also the new fan does have a arrow for counter-clockwise direction. thanks


Does your new motor have two sets of short wires with connectors in the middle of them? If so then it is reversible and the instructions for doing so are printed on the motor data plate on the side of the motor.If it does not have these wires then re ... Air Conditioners