Details I have a problem with a Goodman Model GSH130601AA, ( 5 Ton, 13 Seer heat pump) central air unit, installed 06/15/2006. (I know, I saw online reviews but unit was put in before I saw negative e

\015 Details\012I have a problem with a Goodman Model GSH130601AA, ( 5 Ton, 13 Seer heat pump) central air unit, installed 06/15/2006. (I know, I saw online reviews but unit was put in before I saw negative experiences other people were having)....\012\012The capacitor is not swollen, (and I know that is not a positive indicator-) and the outside fan on top of unit does not turn, but will start to turn when revolved by hand and continues to do so for 30 min or so, after that feels hot (fan motor felt through cowling).\012Buzzing noise until fan on unit is started by hand.Compressor does not start at all, nor is running/cooling now.\012\012The inside fan on the unit runs fine, and the thermostat seems OK, at least shows inside temp. I can set to a temp, but it will not start unit.\012There was no indicator of trouble until Tuesday, 26 June 2012.It was running fine until then. I was cutting grass, went by unit and noticed it had stopped.\012If it will help with any ideas, the temperature Tuesday was 99 degrees with 84% humility.\012******* any equipment, including people. Any Ideas?\012I just can't afford a large repair bill.\012Thanks in advance\012Jim\015

Answers :

The fan motor is bad and needs replaced. Depending on how mechanically inclined you are, you can replace it yourself fairly easy, the hardest part being the fan blade without a hub puller. Just take your old one in with you to a local A/C supply store. The compressor is more than likely kicked off on thermal protection because of the fan motor, happens every time. After the compressor cools back down, the overload kicks back in and the compressor will start. I would also replace the capacitor while I was there, just for preventive maintience because they go out all the time, plus they are cheap. Just make sure you have the full 220v to the unit before diagnosing the problem, and make sure it is completely off when working on it, capacitors hold a charge, just in case you didn't know already. As for the Goodman problem, people never give the full story behind these units. For one, it may say Goodman on the cover, but the motor and compressor are made by the same companies other brands use, just look at the compressor brand, probably a Copeland or a Bristol used in various brands. Two, the reason that there are more negative things said about these units are simple, more units sold, more people have them, there will obviously be more to talk about. Kind of like more money, more problems. Nothing is built like it was 15 to 20 years ago. Goodman keeps their price low by not advertising for the most part. And then you have units like Lennox that are supposed to be good, cost more to buy, and absolutely too expensive when repairing and finding parts. Just so you don't think I'm a Goodman rep or anything, I prefer American Standard equipment over anything else Ha! This is of course all from a service aspect from dealing with this everyday, but still just an opinion. I hope I have helped you and get you to cooler days, and sorry about going on and on, just thought you might like a view from someone on the inside! Have a good one and good luck!

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Details I have a problem with a Goodman Model GSH130601AA, ( 5 Ton, 13 Seer heat pump) central air unit, installed 06/15/2006. (I know, I saw online reviews but unit was put in before I saw negative e


The fan motor is bad and needs replaced. Depending on how mechanically inclined you are, you can replace it yourself fairly easy, the hardest part being the fan blade without a hub puller. Just take your old one in with you to a local A/C supply stor ... Air Conditioners

We conected for the first time a frigidaire portable air conditioner. I dont have the manual. It works great, but I don't know where am I suppose to connect the black thin hose that came with the a/c system. When I woke up in the morning it was all floded. Can you help me do you think there is a leak, or is the black hose needs to be installed? I saw online that people put a pan to collect water


That black hose is for the drain as air conditioners collect moisture as a side effect of cooling the air. That black hose should connect on to the outside bottom of the unit. It wll flood if the drain hole or nipple are plugged or blocked off. The a ... Air Conditioners

I bought an Energy Knight about 10 years ago ductless btw. I was told that I could not install a y valve and put just a 2nd air handling unit in a room just. Below the room with the current air banker. I know I would need an old unit to match one that's so old but any ideas? Thanks Joe


... Air Conditioners

I am trying to get some information on Intertherm unit on the inside of a Manufactured Home, With the new Hud requirements they are saying the out door unit must be installed by the manufactures installation instructions that comes with the indoor unit, my question is will those installation instructions allow you to install a Trane or a Rheme unit ? I know they will work but are they allowed by the Instructions? Would you know if the Trane or Rheme units are Hud approved ? Thanks for any help


Hi, since you live in a Manufactured home and not a R.V., I see no reason why you cannot go with what ever type of condensing unit you want to install on a slab outdoors. The installation instructions for the Intertherm unit for installing the outdo ... Intertherm Air Conditioners

I have just purchased and installed a Samsung AQ12FEN. A qualified Airconditioner company installed the unit. The slpit unit installation is a back to back configuration It replaced a 8 year old split airconditioner that was removed.I purchased Samsung as it seems they use good technology and the unit is quiet according to the technical brochure. When it was installed and put on, the compressor noise was heard through the wall and was louder than the fan noise from the inside unit. It makes an


This could be caused by an installation problem. The system could be severly overcharged, causing the compressor to load up and can cause a failure. i would start there. Is your intaller qualified to install these systems? (does he know what he is do ... Samsung Air Conditioners

I have a Maytag M6P09S2A Air Room Conditioner. I know that it was manufactured by Fedder's and they filed Bankruptcy. The unit works great however when we went to put it away for the winter the drain valve actually broke off all the way to the unit (the plastic inside the unit broke as well). I need to know if I can find a place that may sell replacement parts for these units.


... Maytag M6P09S2ACOM Air Conditioner

I just installed a Goodman GSX130421 3.5 Ton R410a unit alnog with a Goodman CAPF3642c6 3.5 Ton Evap. The outside unit cam with a #076 oriface, along with instructions to put it in. The Evap came with a #78. I put the #76 in, I evacuated the Evapand lines back to the O/S unit. It held 1050 microns for 10 min. The unit hardly cools the Discharge is 430psi, Suction is pegged, outside temp is 93 deg F. High humidity. Where do I go from here?


Since you got it new i think the best way to get this fixed would be to cotact the manufaturer instead of playibg around with things, however these are the causes of the problem : your condenser may be dirty and the evaporator coils should be cleaned ... Goodman Air Conditioners

I have an Amcor 18000 BTU Mini-Split A/C with Heater and Remote. It has never run more than two days and then I get E4 error code. It is difficult to get anyone to service these units in rural areas. I have a guy who works on it and is a licensed HVAC service person but needs some guidance as he deos not normally work on mini-split units and does not know Amcor at all. As far as i know last time he put more coolant in it. I want to purchase several more mini-split units and I have a pla


CLICK HERE for the manufacturer site and your owners manual.\015\012\015\012E4 is an "Abnormality of Outdoor Unit."\015\012\015\012This could be ... Air Conditioners

We had a brand new unit put in a couple of years back. When it was installed it worked. Once winter came, it obviously was turned off. Then the following summer, it would turn on but just blow air, would not cool at all- so the unit installers came out and repaired it. It worked through the summer, then the following summer-it wouldnt cool again-they came back out and fixed it again. Third summer in a row-it is not working again!! A friend told me this morning, on new units there is a


Yes but you should have to keep resteting it you might have a major problem are you beiing charge for freon if so you have a bad condensor unit (it have a leak ) check your bill if the same thing happens again go see what the techs are doing ... Honeywell Air Conditioners

This is our first summer to use our Goodman central air conditioning unit and we are having alot of condensation on our windows and doors. We need to know if our service tech installed a unit too small for our home since we never had this problem with the brand that he removed to install the Goodman. Any response will be greatly appreciated!


Your issue may be just the opposite of what you suspect. If the unit is too small, it will run continuously, but may do a better job of de-humidifying the space because the A/C unit has more time to pull humidity out of the air.\015\012\ ... Goodman Air Conditioners

I had installed fujitsu vrf system ducting type ,outdoor unit model AO54UJBMR,indoor AR22...and I have a problem becouse Ihaven't installation manual and I don't know is it impossible set up outdoor to recognise each of three indoor units'withoout remote control (I have wired type rem. controller)


... Fujitsu 18C1 Air Conditioner

My 6 year old Heat pump RHE 60 on days when temp. gets up to 85F the Compressor struggles to come on some times up to 10-15 minutes.A hard start kit was installed when unit was 5 months old for similar problem but later they (service people) found it was caused by a burnt wire. I dont know if they left the hard-start kit on unit or removed it. I cant get installing dealer to find me a fix for this problem .


Hi,One of the methods to curb if the compressor is not working is " Installing Start Kit".There might be many reasons.Let me write main reasons :-\015\012\015\012\015\012Compressor will not start some or m ... Air Conditioners

We installed a Honeywell RTH230B thermostat on a Trane XE60 Air Handeler this winter. When we put the system on heat it works fine. However, when we put the system on auto for cool the compressor fan comes on but not the air handeler fan. On the air handeler the terminal strip from left to right is R W Y G B/C. The red wire on the R terminal comes from the contactor on the compressor unit. The other wire from the compressor unit is connected to a gray wire that goes to the thermostat. The W


I ran into this before and had to call Honeywell for help in the wiring...it seems the wiring was not done to standard, and they were able to help me get it straight in about 10 minutes and at no charge. ... Air Conditioners

50DF024 Unit had too much oil put in by someone that didn't know better. Compressor died of course. Burnout. I put in a reman comp (06E)and a suction line filter core with cleanout filter. After start up, ran smooth, some oil migrated back to crankcase. High oil level, drained a gallon, oil level barely 1/8 in sight glass. Ran unit for 2 wks, (14 hrs per weekday only)all ok. Changed a filter core again, upon start up, comp was shaking badly and drawing high current. Enough to trip breaker. Oil


... Carrier Air Conditioners

Hi there can u please help me with the commissioning of the above unit . my customer bought mdv iii with 9 indoors from china so all manuals are in chinese , we did the installation to the best of our knowledge and i feel its fine .having installed over 20 vrv daikin units . we wired the controll from the furthest ending with nearest ,well i am not sure weather there is to be bridge at the end but we did not put it. trying to run it well it comes on on cooling then it runs for a few minutes the


I believe you wired it correctly, E-22 should be something related to air-flow. check the Thermistor (R2T) for your Suction Pipe. ... Air Conditioners

Does anyone know how many watts are in a 7 1/2' and 8 1/2' baseboard heater. These were installed new, approx 30 yrs ago. I would like to install an electronic thermostat but need to know what the wattage is. Does it say anywhere on the units what the wattage is?


USUALLY AROUND THAT TIME THEY WHERE @ 2500 KW TO 4500 KW DEPENDING HOW LONG ARE THEY. ... Air Conditioners

I have a goodman 4 ton 15 seer heat pump that has been installed my installer is having a lot of trouble wiring up the low voltage wires and nothing works right .i have a programmable thormostat that worked fine with the old unit but i need to know if anyone knows where these low voltage wires connect . thanks for any help


What is the model # of the controller?The heat pump model # is helpful tooThanks!! ... Air Conditioners

I have a goodman 4 ton 15 seer heat pump that has been installed my installer is having a lot of trouble wiring up the low voltage wires and nothing works right .i have a programmable thormostat that worked fine with the old unit but i need to know if anyone knows where these low voltage wires connect . thanks for any help


Hello,\015\012I have a couple of tips that will help you to see where the wires hookup at. This is not any easy answer and that is why I split it into two tips. There are many combinations for heat pumps especially.. If there are bells and whis ... Air Conditioners

I installed a Mr. Slim system and 2 of the 3 units work fine. The third unit will turn on, but doesn't activate the condensor. In a few minutes the left light begins flashing. I put a multimeter to the outdoor unit and tested the voltage to the indoor units and each combo of wires showed about 240V until I tested the S1 and S3 of the suspect unit and it only showed 120V. Is there a simple solution to this or is possible problem with the circuit board. Thanks!


Sounds like you're missing a leg. check all fuses, you may have one bad one. ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

Have a heat pump mod# 13pja18ao1 r-22 unit trying to fix someone eles bad install . when i got there unit was flat they have alot of old issues with this comp won't kick in only fan even with ajump start kit does this unit have low pressure switch keeping it off diagram shows opt for this unit need to know more steps to take to find out problem


... Weather King 12AJA1801AH Air Conditioner

My unit stopped blowing cold and started blowing hot.i turned off unit looked into furnace and saw pilot was still lit.i put out gas pilot and turned unit back on and it is blowing semi cool air (like fan)but not cool as it should.checked outside ac and it is running....munual says to turn unit off for 2 hrs and if it does not do right then it is compressor.we are currently in the 2 hr process. Any help would be helpful at this point.is there a reset switch or anything I could do to troubleshoo


100 degree temps/high humidity puts an extreme load on air conditioners - but if everything is right with the AC - 'overheating is not a big problem.\015\012\015\012The first thing I would check is whether or not the compressor is running ... Weather King 10AJA4201AH Air Conditioner

Brand new unit have 3 ton inside and out but unit runs all day and will not hold temp i run my ac on 76 but as the day get hot the temp inside will not hold at 76 ARS says they dont know whats wrong but they installed the unit said i would have lower light bill but unit runs all day light bill 900 can someone help please with a solution


Call them back something is wrong if it is that new it is likely under charged. how big is your house square feet and what part of the country down south 400 square feet per ton if your house is more than 1250 square feet the unit is under sized ... Weather King 10AJA3601AH Air Conditioner

Installing thermastat took off amana thermastat and put on honeywell model rth3100c non programable, digital thermastat. but i did not lable wire when i disconnected wires. i put new honeywell on but can only get emergency heat. when i switch to air or heat i keep popping the 3 amp fuse in the relay circit which i just put on new cause i thought that was the problem till i found out my thermastat was bad.i was told by honeywell that it seems like i crossed a wire somewhere. but i need to know wh


Any wire can go to any terminal. unfortunately you now have to hand trace each onre to the device it powers and hook it up accordingly. a daunting task even for a pro. having said that the installer could have used the normal colrs for the usual wir ... Honeywell Air Conditioners

I have a 18000btu LG mini split heat pump installed about 1 year ago in vacation home. In heat mode the unit cycles on and off when room temp is within 2-3 degrees of set point. Cycle on time varies between 35 to 60 seconds (sometimes more). The off time is 2-3 minutes. During this time, I check inside temp with accurate digital themometer mounted at the air intake of the unit and the temp does not change, assume because unit does not run long enough. When I put temp set point more than 3 d


Hello.I think they are on to something with shortcycling on temp sensor.I think it should be sampling the return air instead of (inside coils ?).A 2*f dead band use to be built in (factory installed) to thermostats to prevent on/off, but ... LG LS-L1210CL Mini Split Air Conditioner

Just installed a new thermostat because the air/heat would not come on. I have put the new thermostat in and still nothing happens. I can hear the thermostat click but the fan nor the unit turns on. I have turn off the breaker and turned it back on but no luck. Is there a reset button on the unit, unit is a E1eb015ha


On some thermostats there is a delay when you first apply power. Look at the owner's manual and see if this applies to you. ... Intertherm P3RA-048K Air Conditioner

A detailed question is important to get you a relevant answers