Thermostat with 4 wires, red, green, white and blue; no yellow wire to connect to new thermostat

\015 I have an old mercury thermostat [Lennox/white Rodgers P/N 32M7601, Type LR27935 class 2 1F56W-92], and I purchased a Lennox Comfortsense 3000 non-programmable digital thermostat [Model No. L3011C] to replace it. \302\240I have a Lennox single-stage heat/cool system [Model No. HSXB15-060-230 condensing unit with a gas heat CBX32MV-060 inside unit]. \302\240The old thermostat is wired as follows:\012\012Wall. \302\240\302\240\302\240\302\240\302\240Old Thermostat\012Red. \302\240\302\240\302\240\302\240\302\240\302\240RH with jumper to RC\012Green. \302\240\302\240\302\240Green\012White. \302\240\302\240\302\240\302\240White\012Blue. \302\240\302\240\302\240\302\240\302\240\302\240Y with a yellow jumper to back of thermostat\012\012Therefore, the wires out of wall are comprised of red, white, green and blue\012My new thermostat has a terminal strip with Red, Green, Yellow, White, "L" and "C". I know that "C" is common and "L" is service indicator which will not be connected on new thermostat. \302\240However, without a yellow wire from wall, I am not sure whether I connect the blue from wall to "C" or "Y". \302\240\012I tried to install new thermostat and connected the red to red, green to green and white to white. \302\240But When I connected the blue from the wall to the Y on the terminal strip, there was no power to thermostat. \302\240When I moved the blue to C the thermostat had power and inside blower kicked on, but the condenser would not work.\012\012My question is how do I fix this problem of no yellow wire from wall? \302\240Do I need a jumper? \302\240Any help would be greatly appreciated.\015

Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Thermostat with 4 wires, red, green, white and blue; no yellow wire to connect to new thermostat


... Air Conditioners

I have a Janitrol Heat Pump Thermostat HPT-18-60 and need assistance connecting my new Honeywell RTH7500D thermostat I have a Goodman Heat Pump System Indoor Unit Model#AWB24-05C REV D Outdoor Unit Model#CPLE18-1 Here is the wiring of the old thermostat Y-Yellow Wire G-Green Wire R-Red Wire O-Orange Wire W2-White Wire E-Blue Wire C-Black Wire Where should each of these be connected to the new thermostats terminals?


... Air Conditioners

I'm installing a Honeywell RTH7600B programmable thermostat and replacing a Honeywell T87F2873. The new one calls for a Red, Green, White, and Yellow wire, while I only have a Red, Green White and Blue. How should I connect the new thermostat?


Every thing the same except take your blue wire and replace the yellow for it. So when you hook it to t-stat goes like thisRed to R White to WGreen to GBlue to Y ... Air Conditioners

I have a Trane Heater/AC unit no heat pump with a thermostat model 802AS32DAA that has seven wires. I am going to a five wire heating/cooling thermostat. What do i do with the two extra wires? old thermostat red wire-RC slot (24 V from A/C) white wire-W1 (???) yellow wire-Y (A/C Compressor) green wire-G (A/C Fan) black wire-B (?????) Blue wire-Y2 (????) orange wire-W2 (24 V to Furnace new thermostat therminals G Rc Rh Y/O W/B Y1 Can you tell me what wires to connect to each


From Honeywell : "If your old thermostat had Six or more wires, the replacement you have is Wrong!" ... Air Conditioners

I installed a new Honeywell Programable thermostat, When I turned on the AC it turned on the Heater... I followed the wiring but some of it is not making sense... G=Green, Y=Yellow, R=Red, C=Blue, W2=White, Y2=Brown... The problem is that I have an Orange and Black Wire left over, Which one do I connect to W? and do I have the wiring right... my unit is a central Heat & Air, not a heat pump.


Hi, the problem is you have bought the wrong thermostat for the unit if it is not a heat-pump. A heat pump will have W-1, W-2 for heat strips, and Y-2 is for 2nd stage cooling. G is Green for Fan, R is Red for Power, Y is Yellow for cooling, and W wo ... Goodman Air Conditioners

I am replacing a white-rodgers thermostat with a blue wire connected to a terminal label '4'. The only other reference to a '4' terminal is in the honerwell installation manual which says that if there is both an r and 4 terminals on the old thermostat it was incompatible. I returned it for a ritetemp guaranteed to be compatible though I'm still not sure what to do with the blue wire. on the old thermostat the red wire goes to rc, the yellow to y, white to w, and green to g. Does blue just go t


Blue just goes to B ... Air Conditioners

I need the wiring diagram to wire a thermostat to the outside unit. Which wire goes where ? My Thermostat has four wires, green, red, white, and yellow. My Outside unit has three wires that are not connected ... a red wirte to a transformer, a yellow wire to what appears to be a relay, and a blue wire to the relay switch. Thanks.


The thermostat wires are this, Red is 24 volts hot, Yellow is cooling, Green is fan,indoor, and white is heat.The outdoor unit wires up to the indoor units terminal board, not the thermostat.The red will go to the R or red 24 volt wire at the furnace ... Air Conditioners

Changing out an old mercury thermostat to a digital thermostat. The old therm. has Y=yellow, G=green, R=red, O=orange, C=blue, W2=white and E connected by jumper. Extra wires are black and tan. New therm. has W,Y,C,R,G,O,E. Any assistance appreciated


Y=yellow (a/c)G=green (fan)O=orange (reversing valve)C=blue (common)R=red (hot)W=white, jumper to E (emergency heat) ... Amana Air Conditioners

I need help with my central heat and air unit, it has a heat pump. the model number is GQ3RA-036K. I am changing the theromstat out and the wires are connected to it. there are eight wire colors that are orange,light blue,black, red, yellow,brown,green, white. on the new thermostat are letters that are r,w,y,g,l,b,o,e,aux. Which ones go where?


Normal\015\012 0\015\012 \015\012 \015\012 \015\012 \015\012 \015\012 \015\012 MicrosoftInternetExplorer4\015\012 \015\012\015\012\015\012\015\012\015\012\015\012 /* Style Definitions */\015\012 table.MsoNormalTable\015\012\011{mso-style- ... Air Conditioners

I replaced an old mercury T-stat (York with model number 2TH11704024) installed a new T-stat (RTH6350). The wires that I I have are O (orange), G (green), Y (yellow), T (gray but not used in new T-stat), R (red), L (black), C (blue but not used in new T-stat), W (white) and L (black). I connect all wires with their respective colors except that I connect the W in the AUX (jumped with the E). After I finalized all connections, the heat pump unit (York with model number ETFB024S06A) did not


Did you shut the power off to the air handler/furnace...... before you installed the new thermostat??? You may have shorted out the transformer or blown the transformer fuse...... If you try to put the Fan switch on the stat to Fan ON does the fan ... Air Conditioners

I have an older Carrier Heat Pump which I am trying to update the thermostat control with a Hunter model 44550. The problem is that the wiring to the current thermostat is as follows, G= green wire, R= red wire, W2= blue wire, O= orange wire, Y= yellow wire, E= grey wire and C= white wire. If I am reading the schematic correct for the Hunter thermostate I am to wire as follows Green to G, Red to RC, Blue to W, Orange to O, Yellow to Y/Y1, C cap it as batteries are used. It does not tell me


JUMPER STAYS BETWEEN RC AND RH SO YOU HAVE INCOMING POWER FOR BOTH COOLING AND HEATING. THE WHITE WIRE YOU SAID C IS COMMON AND SHOULD BE USED IF POSSIBLE TO COMMON TERMINAL ON NEW STAT . IF THERE IS NO COMMON, THEN CAP IT BUT YOU'LL BE CHANGING BAT ... Carrier Air Conditioners

I have an amana rha36b2a heat pump and am trying to hook up a new thermostat. It's a pro 1 iaq t905 programable thermostat. I have hooked up the green yellow white and red (and ran a jumper wire from rh to rc). I also ran a jumper wire from W to Y. I ran the brown wire to C. The thermostat works great for heating but won't cool. When cool is chosen the heat comes on. Help! I know the O and B on the thermostat are the heat and cooling changeover valves but what should I do to connect them if that


... Air Conditioners

Thermostat Connection ________________________________________ I just purchased a rheem rqpm series 4ton packaged heat pump and a honeywell pro th4210d thermostat. I had 15 kwatt heat strips installed in the heatpump as I live in norther florida where the temp might drop to 20 degrees occasionally. I am unclear as to how to connect the thermostat. The wires coming from the heatpump unit are red, yellow, blue, green, white, and brown. The thermostat terminals are as such: E Aux Y G O L R B


Jumper E to Aux, OR B + O, G--green, R----red(power), & C--------common. w2---------white, Y.....Yellow and finally the Brown-----------PRCrossed my fingers too & go for it. worst is a warning hum &/or sparking one one terminal whic ... Air Conditioners

Ruud contour acheiver 90 plus trying to replace bad thermostat with Nest there is a black wire which goes to a "V" Not sure if this is also a power wire? the other wires are red to 24 V; blue to 24 C; Green to G; yellow to Y1;White to w Any help to connect to Nest second generation thermostat?


... Air Conditioners

I need the wiring diagram for this thermostat, there are four wires that are hooked up red,white,blue for yellow and green. They connect to a honeywell relay that has five connection, y,g,w,c,and r, do i connect them the same way as colors match


On the fan relay hook up the red to r terminal the white to the w terminal and the green to the g terminal , now the blue needs to hook up to one of the two wires going to the outside condenser unit and the other going there goes on the c terminal . ... Carrier TSTATHCP Programmable Thermostat Air Conditioner

Replacing the thermostat, took the old one off without marking the wires. Hooked it up by color and we get the furnace when we put it on cool. wires are green, red, yellow & blue (ground wire)on the wall. The new thermostat wires are red, yellow & green. Can you tell me which wires go where correctly?


The normal wiring for stats is white=w=heat,red=r=24volts,green=g=fan,blue=c=common,yellow=y=cooling.\015\012see what ties into your furnace board and match the terminals. ... Honeywell Air Conditioners

Need to change a broken blower motor in RUUD central air unit. Old central air blower motor (GE electric) was connected with brown and orange wire to 15 MHD capacitor. Another orange wire from central air unit connected to orange motor wire on capacitor. Black wire from motor (Hi Speed) connected to central air unit. Blue and red wires not connected. New motor is an AO Smith FD6000A. Has Black, brown/white, brown, blue,yellow,red, white and black wires. Need to connect to a 5 MHD capacitor. M


On the motor should be a diagram detailing the wires. brown white goes to either side of the capacitor and brown wire to other side of capacitor. hi speed goes to normally open contact on the indoor fan relay and the wire designated common on the mot ... Air Conditioners

Trying to reconnect an old thermostat. The wires on the thermostat are yellow, white and there is a jumper wire between two points. There is a G which I presume is ground. The wires coming in are white, red (hot wire)light green and dark green. The light green came from the ground on the thermostat I am replacing. Any sugestions as to where to make the connections? Thanks


G (green) = fan\015\012w (White) = heat\015\012y (yellow) = a/c\015\012r (red) = power\015\012\015\012Connect white to w terminal and red to r terminal on t-stat since we know they are right, then touch one green to red ... Air Conditioners

I have a tempstar with 6 wires. Green, Blue, Red, Yellow,White, and Orange. I am trying to install a White Rodgers 300 thermostat and letters are not matching up. The thermostat has G, A, RC, RH, O, B, Y, and W. I don't know where to hook the blue wire which was labeled C. Unless it goes to RC and the red goes to RH could you please help? Thanks


You need to verify the function of each wire with Tempstar then cross it with the WR stat. Call the techline if you need further assistance 18002842925. ... Dometic Rooftop RV Air Conditioner

I have 5 wires, white, red, yellow, blue and green and am trying to install the Hunter programable thermostat model 44360. I am not sure which wires connect to what...help.


The standard code is red is power or [R] on your t-stat, yellow is cooling or [Y], blue is common or [C], and green is fan or [G]. This is standard across U.S.A. if the installer, installed it correctly. I as a rule of thumb look in the air handler t ... Hunter Air Conditioners

My old thermostat has 8 wires, red, white, green, gray, black, orange, blue and yellow. I have the 44110 model need help connecting the wires


Open unit and see what wires are running what never trust the colors.white heat'yellow cool'red 24v,green fan,blue prob your com, ... Air Conditioners

I am replacing a White Rogers 1F58-77 with a Honeywell RTH2300. When I removed the old stat the wire colors are white, red, orange, green, yellow, and blue. G- green wire Y- Yellow wire R- Red wire W- White wire O-Orange wire X1- Blue wire I hooked up all the wires except the blue. Instructions with the Honeywell unit said not to hook up the blue wire if there is an orange wire to hook up which I did. The problem, when I light off the A/C (heat pump) the compressor comes on but the


Yes you did correct. Tape of f blue wire. On your thermostat you should have el/gas turn top el and fan should work Russ ... Air Conditioners

I have a Trane XE1000 heat pump and a RiteTemp 6036 Thermostat. I have red,orange, black, white, yellow, green, blue & brown wires & need to know what to connect where?


... Air Conditioners

I just replace a Honeywell T87F28733844 Thermostat with a Honeywell RTH221 Thermostat since then my the furnance will not produce any heat. I replaced the thermocouple, but still no go. The pliot light is lit, but still no go. The wires that went to the T87F are yellow, green red and blue. The RTH calls for a yellow, green, red, and white, with a jumper jack in the Rh Rc. The blower for the fan works, and the ac works, but not the heater


The heat circuit uses 2 wires to the thermostat one is the power from the transformer, and the other goes to the gas manifold.\015\012\015\012The Rh and Rc is probably the power for heat and cool, and this is where the red would attach IF ... Air Conditioners

I am replacing a white rodgers thermostat with a honeywell rth3100c. i have matched my wire as e (brown) to e w2 (white) o aux y (yellow) to y g (green) to g o (orange) to o l blank r (red) t r b blank c blank now i have a blue wire which was hooked up to the x1 on the old thermostat. where does this wire go?


Blue (C) or sometimes (B) should be your common wire. Look at your schematics and locate common. Your Brown wire is (E) and is emergency heat, white wire (W) is Auxilary Heat, green wire (G) is fan relay, red wire (R) is power, yellow wire (Y) is C ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific