Having problems with your Air Conditioners ?

Blower motor in home air conditioner does not work

\015 The blower motor for the furnace and air conditioner does not run. The outside compressor runs.\015

Answers :

The most common failure for this problem is either the start/run capacitor or the fan motor. IF YOU ARE NOT experienced with electricity then I would strongly suggest hiring a technician. The volts are 220 with a potential of 50 amps in a common residential unit.

If you are knowledgeable in this area then make sure the motor has volts to it. If it does have volts and does not spin, it is bad. You can sometimes tell by feeling the motor it will probably be very hot. The compressor will eventually shut itself off when it over heats. It usually will restart after it cools down(sometimes many hours). The motor and capacitor are pretty generic and can be matched up at a local Grainger store or whatever Retail, specialty store that you have in your area.

I hope this helps:)

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Blower motor in home air conditioner does not work


The most common failure for this problem is either the start/run capacitor or the fan motor. IF YOU ARE NOT experienced with electricity then I would strongly suggest hiring a technician. The volts are 220 with a potential of 50 amps in a common resi ... Air Conditioners

Hello, We bought a Perry Home in Georgetown TX last March and it is still under its two year warranty. Our air conditioner stopped cooling today. It has been working well for over 1 year. We came home from work and the temperature is 86F inside and climbing. My wife left the house at noon and the temp was 76F (where we keep the thermostat in the summer). The Air conditioner outside unit's fan is operating and no noise. The inside blower is running normal - no problem. The model number on the o


You have a 10 year warranty on your AC. Call a Goodman rep and have it serviced. It will probably be a bad compressor capacitor. Bad wire or no refrigerant. ... Goodman Air Conditioners

Just bought a used 1987 Real-Lite truck camper. The roof air unit is Dometic as well as the LP/AC refrigerator. When turned to "cool" the air conditioner really draws down, dims the lights, and eventually blows the home AC breakers. It works fine on blower fan only but as soon as I engage the "cool" settings, big brown out. The fridge doesn't work at all. I'm in the Nashville area. Suggestions


To start with, if it's plugged in to a 15 amp breaker, and extension cord, the compressor starting up may just be enough to trip the breaker. It will draw close to 15 amps on start-up of compressor, and if there is a light extension cord used to plug ... Dometic Rooftop RV Air Conditioner

I have a wall mounted Kenmore 21,000 BTU/hr air conditioner model 106.8752192. The compressor and cooling portion of the air conditoner works fine. However, the blower motor bearing appears to be going bad. The noise at ''LO'' speed with the compressor off is gradually getting worse. Is it repairable? What is the estimated repair cost?


Sure it is repairable, in fact it's a relatively simple process if you are familiar with electronic devices and handy with tools.\015\012\015\012You will need to simply replace the blower motor and capacitor.\015\012\015\012Mo ... Air Conditioners

We are selling our house and have been leaving the air conditioner on for the last several days at 70. It has been keeping the house cool for visitors when we are at work. Yesterday I came home from work and the house was warm. I checked the air conditioner and it felt like it was blowing just air. Checked it throughout the night and still blowing just air, not cold anymore. I am thinking it ran out of coolant. I am not an expert or know anything about air conditioners. If you could give me your


It can be many things like a loose connection. It can be low of refrigerant or it can be the condenser fan has stopped working. Considering you are selling the house just call a qualified HVAC repairman and have it repaired. ... Air Conditioners

Blower motor no work - Air Conditioners


Bad fan motor or capacitor. Most of the time it is a fan relay. ... Air Conditioners

I have a split unit and the one wall unit does not work at all. I called an air conditioner contractor and he replaced the circut board and blower motor. When he turned the unit on it blew the new parts. Now he is telling me that it cannot be repaired. Can you please help ?


Hi,I have no idea, how they replaced the circuit board and blower motor without running the diagnostics or inspecting different components. It would be really hard without looking at the AC that what's wrong with it. It could be a problem ... Samsung AS18A6RB Air Conditioner

Air Conditioner seems to be working but the Blower Motor does not come on.


Some units use a relay to change fan speeds.Heat requires a slow speed while cool requires a faster speed, Take a ... Air Conditioners

I have land cruiser wagen model 1995 the proplem in air conditioner when oprate the plower switch to low or m1 or m2 or high is ok but when moving the thermostat to hot the blower motor is not working.


In some models the air conditioning system and the heating system are separate and you need to switch off the aircon if you use the heater. Or if it is a heatpump system, the fan will switch off while it is in reverse cycle allowing pressure to build ... Air Conditioners

Blower motor don,t work - Air Conditioners


That doesnt tell anything check your capacitor did it suddenly go out how old is it whats it on what happened when it went out have you ever had problems with it the most common thing is the capacitor its a canister with with wires plugged in it it m ... Air Conditioners

Hello i have Carrier Weathermaker 38tkb air conditioner unit. It's about 6 years old and when i got home today, the unit itself wasn't working. Although the blower fan in the furnace inside was blowing, the fan on the a/c unit outside was not moving. I can hear a humming sound coming from it and once in a while, you hear it trying to kick in (the lights in the house even dim a bit, which is unusual), but it never kicks in. The top center of the unit is extremely hot to the touch. I've checked


The humming noise and dimming of the lights is an indication something in the outdoor unit is locked up or has failed.Check the capacitor as it may have gone bad. If the capacitor is good, then you either have a failed motor, a failed co ... Air Conditioners

Hi, just replaced the capacitor thinking that would solve the problem but it appears it did not. The motor outside would kick on the unit inside would kick on but the blower motor inside works sometimes and wont other times. Basically, the unit will work just fine all day then we notice the house is getting warm, check the inside unit and everything is running fine but the blower motor is not circulating the air. I have a goodman a30-10 unit. I read where some people said the relay could be bad


Turn off the power to the air handler(indoor unit). Remove the access panel. From the motor,trace the wires back to the fan relay. One wire will probably trace back to the incoming power terminal. The other is the fan relay. It could be intermittent ... Air Conditioners

Blower fan motor wont start on carrier package unit air conditioner I have a Carrier 50ZPA042-301TP package unit


... Air Conditioners

Have a Payne pg8uaa furnace. Furnace only works when I run a jumper between R and W. Replace wiring to furnace. I suspect that the outside blower motor is the problem. When furnace is running the blower motor has a humming sound but does not blow air. At this point, I would like to know how you would diagnose a Tjernlund HSUL-J blower motor. Should the motor itself be replaced or should the fan prover be replaced?


You would have to test the motor as well as the capacitor on the motor capacitor goes for alot less then the motor though.here is the pdf manual on your blower h ... Air Conditioners

Problem I turned on my air conditioner this spring. I turned the switch to cool on and the air conditioner fan not going. I took cover off and got new capacitator didn't work. I took fan motor into electric shop and checked out fine. When I turn switch on the contact switch engages and there is a humming noise. But the fan does not work. the compressor doesn't start up. The model is at least 10 years old. How do we tell what the SER rating is?


Hi,\015\012There are two things to check....\015\012\015\012Do you have power coming into the contactor???\015\012\015\012Do you have power coming out of the contactor???\015\012\015\012If you have power goin ... Air Conditioners

I have an amana air command furnace/air conditioner. model ev4 gtc, serial number 569162. it is 25 years old, original furnace when we had home built. it had been working fine, on air conditioner setting. then it stopped working completely. i had this problem a few months ago, called a service person, who spent 5 minutes, told me it was a switch that needs reset if doors are off the unit for a certain period of time and charged me $68. i have tried to look at the layout of the furnace, but what


Hi,it is just a suggestion, don't you think it will be nice for you too get a new one to save you all the stress of repairing?. 25 years is good, but it can be better if you try a new one and there will be newer models which great future ... Amana Air Conditioners

Where can I find a manual for my coleman cam II central air conditioner for a mobile home? I recently purchased the mobile home and would like to know what steps to ntake to make it work at its best. Also, I find it puzzling that the air filter is set on top of the unit inside the mobile home. It looks to my limited knowledge of central air, as if someone set the filter on top of the unit because they did'nt know the correct location placement. Can you provide any comments or advice? Thanks


Check the website for Coleman/Intertherm for a manual, you will need the model and serial numbers of the unit. The filters for these typically sit on top of the unit, some come with frames, some lay directly on the coil. If you can't find a manual on ... Coleman Air Conditioners

Sometimes, when the inside blower shuts down, the outside compressor and fan motor continue to run for some time. Other times, when the inside fan motor is running, the outside fan and compressor motors are not ... if I press the outside reset button, it starts up When both inside fan motor and outside fan and compressor motors are running, it works fine ... warm air blows out of registers. Other than that problem, both units work great!


Sounds like you have a dirty condenser. You are going to need to disconnect the power at the outside unit on the wall by pulling the fuse block out. Take a good look at the louvered covers that are attached to the outside of the unit. Remove the scr ... Ruud UAKA060 Air Conditioner

Hi I have got adouble storey house. I have moved into the house this year. My Fujitsu ducted air conditioner is not cooling well. I think the blowers are too slow. My model number is AOT60RPAGT. Cooling in downstairs is ok but upstairs in the bedrooms it is not good. When I put my hand close to the vents I can feel a bit of cold air but I think the blower is too slow. I have selected blower speed to max on the control panel but still it doesn't work satisfactory. Please advise. Thanks


... Fujitsu Air Conditioners

My carrier air conditioner is not working. We have two exterior units. One for upstairs (smaller) and one for the downstairs(larger unit). That being said we have two seperate thermostats inside our home. The upstairs unit is working fine. The downstairs thermostat shows on Auto that the unit should be kicking on based on the temp. However, the outdoor unit for downstairs is not working. So far I have checked the downstairs vents and they are blowing air although not very cool. I also tu


Hi,The problem is in the outdoor unit...The compressor could be locked up, the condenser fan could be bad... or from what you are saying the contactor for the outdoor unit is either not pulling in or is bad...that also can be a result of ... Air Conditioners

My classic plus 26 air conditioner stop working. The blower is working, the compressor is working but we don't get any cool air. The drain is dry, no water is coming out. What could be wrong?


Hi,First thing to try is to remove the unit from where it is mounted. Carry it out and remove the unit from its case. This will require removing quite a few screws. the unit will slide out of the front of the case. wash all of the fin coils wit ... Movincool Classic Plus 26 Air Conditioner

Air conditioner runs for a few hours and it works - it cools the house. Then it stops cooling - the fan still runs but it doesn't blow out cool air any more. It seems like it's overheating or something. It will blow out cool air if it has not been turned on in a while but once it's on too long it stops. I was told it could be the fan motor and the a/c guy changed the fan motor today but that didn't fix the problem. Now he says it might be the compressor or that I need a new system. I'm jus


The things I would check:\015\012Is the system properly charged with freon? Sytem may be overcharged.\015\012Is the compressor out on internal overload at the point of failure? If the overload isnt tripped and the compressor is having tro ... Air Conditioners

Honeywell T8112 Air Conditioner Will Not Cool, But Blower Works


Make sure the system switch is in the cool position, then press run program button and allow a couple of minutes for system to cycle on, if it doesn't come on press the button for lowering the set point, set it to 72 degrees and then press the hold t ... Honeywell ER150B Air Conditioner

Air conditioner motor runs, fan not working - Haier Air Conditioners


Hi,If it is not running and the compressor is, then you have a bad motor...you can get a new motor easily online from www.grainger.com ... Haier Air Conditioners

Goodman B1370735S Air Handler Time Delay Relay Can these be troubleshooted? Our air conditioner quit and it has power to this board. The motor or anything else will not work. The upstairs thermostat is working.


... Goodman Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy