Installed a new Filtrete thermostat on a new Carrier high-efficiency furnace. I followed instructions exactly. It doesn't work. What did I do wrong? Furnace was installed in December. Broom handle cracked faceplate of Carrier thermostat and rendered it inoperable. Installed new thermostat according to instructions. Connected white wire (labeled V+ on the old Carrier thermostat) to the W terminal on the new Filtrete thermostat. Connected red wire (labeled Vg on the old Carrier thermostat) to the


Answers :

Thanks for the update, regarding the thermostat.Hope replacing the thermostat resolves the problem.Keep updated.Thanks.Helpmech.
Hi.Does the new thermostat has the same rating with the old one?

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Installed a new Filtrete thermostat on a new Carrier high-efficiency furnace. I followed instructions exactly. It doesn't work. What did I do wrong? Furnace was installed in December. Broom handle cracked faceplate of Carrier thermostat and rendered it inoperable. Installed new thermostat according to instructions. Connected white wire (labeled V+ on the old Carrier thermostat) to the W terminal on the new Filtrete thermostat. Connected red wire (labeled Vg on the old Carrier thermostat) to the


Thanks for the update, regarding the thermostat.Hope replacing the thermostat resolves the problem.Keep updated.Thanks.Helpmech. ... Air Conditioners

I have a carrier 38YKC036300 heat pump with an electric furnace. I am attempting to install a new bryant T6-PRH thermostat http://www.catalog.bryant.com/wcs/proddesc_display/0,,CLI1_DIV42_ETI4641_PRD1583_SIT70,00.html. The wires dont exactly match up with my old existing thermostat. My existing thermostat has the following connections: W2, C, R, G, E, O, and Y. My new thermostat has Rc, Rh, W/W1, G, Y/Y2, C, O/W2/B, Y1. Please tell me which wires go with which terminals on the new thermostat. P


Old Tstat New Tstat\015\012R Jumper Rc & Rh\015\012E W/W1\015\012G G\015\012Y Y/Y2\015\012C ... Carrier 38CKC036 Air Conditioner

I tried to replace my digital manual Honeywell thermostat that is only 6 months old (new construction) with a programable thermostat. I followed the instructions marking the wires and connecting them up the same way. There was one wire "C" wire that the old thermostat connection said was optional with batteries that there was no place to connect on the new thermostat. I taped it off and left it off. The new thermostat with batteries powered up but the AC would not respond, nor the fan, nor t


Your "R" terminal is basically your "hot" and your "C" terminal is basically your "neutral" to simplify explanation. The Furnace supplies the "R" power to the thermostat and then depending on what wire the thermostat sends the power back on determine ... Honeywell Air Conditioners

I'm installing a Honeywell RTH6350D thermostat. I'm replacing an old thermostat with mercury and only two wires connected to it. Unfortunately, these two wires are not labeled. How would I hook them up to the new thermostat.


One to R terminal the other to W terminal ... Air Conditioners

I want to install a new thermostat on my furnace, but the wire connections on the old thermostat are not marked. I have been unable to locate a diagram with wire labeling. Can you help?


Your t-stat has a override program on it look for the hold button and cancel the function. Should be able to just press the hold temp button and it will resume the normal program. ... Air Conditioners

I am replacing a white-rodgers thermostat with a blue wire connected to a terminal label '4'. The only other reference to a '4' terminal is in the honerwell installation manual which says that if there is both an r and 4 terminals on the old thermostat it was incompatible. I returned it for a ritetemp guaranteed to be compatible though I'm still not sure what to do with the blue wire. on the old thermostat the red wire goes to rc, the yellow to y, white to w, and green to g. Does blue just go t


Blue just goes to B ... Air Conditioners

I currently havea honeywell thermostat model# T8112D1005 (1) 0347 PF2A and a replacing it with a Honeywell TX1500E. My only issue is my old thermostat has a "R" wire that was connected up to it and my new unit only shows two options "RH" and "RC" it does not have an output of only "R". My question is where do I hook up the wire marked "R" from my old unit or do I even hook it up? The instructions mention if replacing a TM-11 to tape off the R wire and hook up the B wire to the B terminal. Im nit


... Honeywell Air Conditioners

RTH221 honeywell thermostat install, hooked up blue wire from old thermo that hooked to C to o/b connection on new thermostat no work did I screw something up as old thermo will not work as well now. was not supposed to hook blue wire up I found out later on Internet. any easn fix, blown fuse??? etc. Thanks


Hi,\012maybe a blown fuse if it has one... if not then you blew the transformer...\012Check on the circuit board in the furnace or air handler for a fuse...\012if there isn't one... then you will need to replace the 24v transformer. ... Honeywell Air Conditioners

I have a carrier air/heating unit with pump. It has 8 wires. Brown,blue, white, yellow, green, black, orange,and red. I'm trying to install honeywell thermostat. The wires from my unit are suppose to go into these honeywell (RTH3100C) thermostat slots. hONEYWELL WIRE SLOTS E Aux Y G O L R B C The only thing i have to go on is the wire colors from my wall which were not labeled or coded in any way. I am not sure about the model# of our unit because it is so old that the model# has faded away the


Turn the power off to the air handler. Open the control cover. Write down what color wires go together at the wiring terminal. All 8 wires are probably not used.\015\012Post the findings here.\015\012In most cases,\015\012E= brown-e ... Carrier Air Conditioners

Im changing an old honeywell thermostat with a new honeywell thermostat. the old on has wires 4 wires connected to 4 screws C,R,G,W but the new thermostat has a place where the wires go which are Rh,Rc,W,Y,G. will i be able to connect the new thermostat?


Yes, I believe that you will be fine. If the original wiring is correct then I have listed the basic wiring below. As always read the directions and make sure the wiring matches your system.Red wire = Rh (24v power, should have an exsi ... Honeywell Air Conditioners

I just installed a P474-1100REC & P474-1100RF in place of a Honeywell Thermostat.I have a typical 4 wire 1 stage Cool 1 stage gas heat setup. The new thermostat is not working right. I noticed on the old thermostat there was a jumper wire from R to R1. Do I need a jumper wire set-up here as well? If I do where do I connect to? There is no R1. Please help


Does the new stat have a rc and an rh if so you will need a jumper between them ... Air Conditioners

I have a Janitrol Heat Pump Thermostat HPT-18-60 and need assistance connecting my new Honeywell RTH7500D thermostat I have a Goodman Heat Pump System Indoor Unit Model#AWB24-05C REV D Outdoor Unit Model#CPLE18-1 Here is the wiring of the old thermostat Y-Yellow Wire G-Green Wire R-Red Wire O-Orange Wire W2-White Wire E-Blue Wire C-Black Wire Where should each of these be connected to the new thermostats terminals?


... Air Conditioners

5 ton carrier. we changed the condenser motor and marked where the wires connected. Old motor had yellow and brown to capacitor. New motor has an extra brown wire with white stripe... I connected it the same way as the old one without using the extra wire.... didn't work. Advise how to connect the new 5 wire motor... red and black wires I'm confident are connected correctly.


The best way to wire that motor is to connect a separate capacitor to it. The brown and brown w/white stripe go to the capacitor. The black and red wires go to the contactor. ... Air Conditioners

LENNOX HS26-048-3P Installing Honeywell wifi thermostat. C terminal on control board was connected to X on the old thermostat. The X terminal wire on the old thermostat is connected to the C terminal on the control board. I used this wire to connect to the thermostat C terminal and now the compressor fails to come on. The slow flashing lights indicate the thermostat is asking for cool and the fan comes on, compressor does not come on.


... Air Conditioners

Wiring compressor Replaced defective fan motor on my a/c unit. Old motor had three wires: black, yellow, brown. New generic motor has black, white, brown, brown w/white stripe. This new motor came with a new two terminal capacitor. Old cap. had three terminals. The black and white wires from motor connect across the line voltage and the other two wires connect across the capacitor. After install and trying to run the unit, found that compressor turns on for about two seconds and shuts down, but


The two terminal cap is only for the new fan motor. Connect the compressor wire back where you found it, on the 3 terminal cap. It's the terminal marked, "herm". The "common" terminal on the 3 terminal cap must still be connected to one side of the ... Carrier 38CKC036 Air Conditioner

Have a 4 wire ac/heat system, installed new thermostat, cannot reconnect them as the leads were not labeled and the old thermostat was broken


Give me the the model number and Mfg of your equipment along with the color codes at the unit, not the thermostat wire at the thermostat, and I can assit. Contact me directly.\015\012\015\012Richard (Rick) DrennanGlobal HVAC Distrib ... Air Conditioners

Am installing a ceiling fan and do not have the installation instructions. The fan has a black wire (labeled Motor), a white wire (labeled Neutral) and a blue wire (labeled Light). What is the proper connection to my black and white house wiring ?


When dealing with older houses, you run into this a lot, but the somewhat newer houses will actually have the 3 wires to hook up the ceiling fans. You can still use your 2 wires, but you will have to double up the motor and light wires. Wire nut the ... Air Conditioners

I just got a new honeywell thermostat and it when i first hooked it up it wouldnt turn on so i check to find out which connections on the thermostat when open i changed my wire to make it correct now when it turns on it doesnt turn off. i only have 2 wire that were on the old thermostat and the new one shows spots for 3 wire do i need to run a 3rd wire to get the furnace to shut off after it reaches desired temp? right now i have to disconnect the thermostatto shut it off.?


Hello my name is Heath it will be my pleasure to assit you. If you did not turn the power off to the furnace before rerplacing the thermostat then you may have burned out the board in the furnace. But first if there is a RH/Rc terminal in the new the ... Honeywell Air Conditioners

I have a Trane Heater/AC unit no heat pump with a thermostat model 802AS32DAA that has seven wires. I am going to a five wire heating/cooling thermostat. What do i do with the two extra wires? old thermostat red wire-RC slot (24 V from A/C) white wire-W1 (???) yellow wire-Y (A/C Compressor) green wire-G (A/C Fan) black wire-B (?????) Blue wire-Y2 (????) orange wire-W2 (24 V to Furnace new thermostat therminals G Rc Rh Y/O W/B Y1 Can you tell me what wires to connect to each


From Honeywell : "If your old thermostat had Six or more wires, the replacement you have is Wrong!" ... Air Conditioners

Thermostat with 4 wires, red, green, white and blue; no yellow wire to connect to new thermostat


... Air Conditioners

I am installing a new thermostat for my baseboard electric heat. The electric box has 2 wires comming into it. So I have 2 black, 2 white and 2 ground. The old thermostat had a place for all 4 wires (one side line one side load) the new thermostat is a honeywell RLV430 High voltage (at least I got the high voltage part right). It only has 2 wires so I am at a loss as to what to hook up where. My inclination is to hook the load to one and the line to the other. But I don' know if this is r


Hi tlef\015\012\015\012To answer your question;\015\012\015\012Tie the two whites together with a marette , and the two blacks to the thermostat , it doesn`t matter which wire goes where on the thermostat since there is no polarity.\015\ ... Air Conditioners

I replaced an old mercury T-stat (York with model number 2TH11704024) installed a new T-stat (RTH6350). The wires that I I have are O (orange), G (green), Y (yellow), T (gray but not used in new T-stat), R (red), L (black), C (blue but not used in new T-stat), W (white) and L (black). I connect all wires with their respective colors except that I connect the W in the AUX (jumped with the E). After I finalized all connections, the heat pump unit (York with model number ETFB024S06A) did not


Did you shut the power off to the air handler/furnace...... before you installed the new thermostat??? You may have shorted out the transformer or blown the transformer fuse...... If you try to put the Fan switch on the stat to Fan ON does the fan ... Air Conditioners

I installed a new honeywell rthl111 series in Oct. 2012. I wired the blue wire to the RC because that was how the old thermostat was wired. The heat worked all winter but when I tried to change over to cool nothing would work. I checked the schematics online and realized I should have installed the blue wire to the B. I checked the fuse in the power panel and saw I had blown it. I changed it and rewired the thermostat the correct way. I tried again and still neither the cool or heat will work. A


... Goodman Air Conditioners

I am replacing my old a/c fan motor with a new one. The old motor is an A.O Smith B13400-251 and has black, brown, and a purple wire and was connected to a dual capacitor. The new motor is an A.O Smith ORM5458 and has a white wire on one side and on the other is a black, brown, and a brown/white wire. The dealer sold us a single capacitor and i'm having a hard time figuring the wiring. Can anyone offer some instructions?


For one, thank you for posting all the info, it really helps! On your new motor, the white has became your purple, black is black, and your brown/brown and white wires go to each side of the new capacitor, there should only be 2 terminals. You can le ... Air Conditioners

Wiring instructions for Thermostat Honeywell with Carrier Package


Jumper R to Rc and hook hot wire from transformer to R usually red wire\015\012O = Reversing valve probably white or orange If you get heat when calling for cool or Vice Versa then switch wire from O to the B terminal.\015\012Y = Contac ... Air Conditioners