Air handler fan runs but condenser fan and compressor won't, I changed the relay switch but still no results, is it the capacitor? It is an Armstrong, model # SCU10E36A-4. Thanks.


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Air handler fan runs but condenser fan and compressor won't, I changed the relay switch but still no results, is it the capacitor? It is an Armstrong, model # SCU10E36A-4. Thanks.


... Air Conditioners

Dear Sir/Madam, I have a 12 years old Goodman split AC. Recently the blower in the air handler was not starting sometimes. I changed the capacitor, but the problem is still there. I guess that the fan relay switch may be bad. Where can I find the fan relay switch for Goodman center AC? The model no for air handler is AW24-05c, the serial no is 9904464660. You help will be much appreciated. Thanks, Sherman


... Goodman Air Conditioners

I have a Duo-Therm Penguin model#610115405 that cools and the fan changes speed(slower) when the room gets cooled and the compressor kicks out, but the fan will not shut down.I have the same unit fwd in my RV that works fine. I tried switching the thermostat,ptcr relay and the capacitor that is below the ptcr. Any other suggestions ? Dont see anything that else that I can easily switch to check.Still not shutting down?


Hi,\015\012the relay that is suppling the power to the fan is welded shut and is not opening. This often happens with relays, the contacts get pitted and then they heat up and weld fast. The relays that run the fan faster and slower are still w ... Dometic Rooftop RV Air Conditioner

I have a ruud model no. ubhc-17j11nfd and i am having a problem with my heat. when the heat does come on, the thermostat says it is on auxilary heat. the blower in the inside unit does not run. i changed the capacitor and now i get a really loud humming noise. the motor still does not spin. but when i spin the motor by hand then it seems to work fine.(the humming goes away) this happens every time when the heat goes off then back on. the only way to solve this is to keep the fan on constantly.


... Ruud UBHC Air Conditioner

I have a Fedders window AC unit, model: A2Q10F2BG-AC. It works in the Cool position. When switching to the HI FAN position it shakes and then stops. Changed the capacitor because it was not doing anything. I am not sure what to do next.


... Air Conditioners

I have a Goodman airhandler model #A24-10, serial #9305071035 and can not get fan motor to cut off except by turning off breaker. Ihave replaced two sequencers and checked out all 24volt wires to therm-o-stat, changed therm-o-stat and still got no results. Would appreciate and help you can give me. Thanks


... Goodman Air Conditioners

Have a Grand Aire Central Air and Heating unit a/heat pump...has been working fine. Switched it over to heat and nothing came on. Switched it back over to air, which was working and still nothing came on. Switched fan from ''auto'' to ''on'' and the fan will not come on. Used a screwdriver to push the contact in and everything runs (air and heat) as long as I am holding the contact in. Changed the t-stat, still the same problem. I really don't have the finances to call a pro in, any advice will


The fuse may be in line (red ) wire check control voltage if not present transformer (or fuse) needs replaced \015\012 the problem probably was caused by white wire (heat control voltage) has been wired to common not heat control ... Air Conditioners

How do I wire a fan motor and the two associated capacitors to make it run? I was given a Hunter Model 26136 ceiling fan motor and the two capacitors that came with it: 1st a two wire (red & black) 5F 250vac VCE 74132-01 and 2nd a four wire (green, brown and two gray wires) GY 5GR 5B 250 VAC VCE74133-01. Also I know I need to buy a 3 speed switch. I have no idea how to wire the motor, capacitors and switch together. John Bierke


... Air Conditioners

Indoor fan motor continue to run even if the thermostat is in auto position with the cool and heat switch in the off position. The furnance don't have a fan on and off switch in the furnance like most. The only way to turn the fan motor off is to turn off thr high power switch. I change indoor fan relay but the problem still exist.


Try this, disconnect the fanwire (green) on the furnace, if it shuts off then the hot wire from the thermostat is touching the green wire or bad thermostat. Thank-you-very-much! ... Intertherm Air Conditioners

Ruud furnace Model UGPH-10EBRJR Silhouette ll. blower fan stays on continously, (also draft blower) and the only way it will shut off is to disconnect power. I've replaced thermostat, fan limiter switch, switch on the blower housing, even replace circuit board (IFC). I've even disconnected the thermostat wires to circuit board and blower still comes on as aoon as power is connected. I've disconnected everything on the circuit board except for blower wires and 24 volt transformer and it still com


... Air Conditioners

I own an armstrong air unit after about 30 minutes the unit seems to get hot and the fan quits the compressor is still running I changed the motor on the fan and it still does the same thing I have also changed the braker and put in new wiring from the disconnect box to the unit. Please Help, Thanks Jimmy Watson


Chech the fans rotation , the fan is suppose to blow air out the top, also if you changed the fan out ,check for the blade on right, its suppose to scoop the air from the inside and blows it out the top,, also replace the capicator...sounds to me lik ... Air Conditioners

I have a Coleman Evcon gas furnace model# DGAT095ADA last year I replaced the T-O-D #60T82 - 313675 fan switch and works fine. This year the unit started fine, but slowly started taking longer & longer to heat up, then finally not heating up enough to trip fan switch. Manually tripping fan switch resulted in some warm air through system, but not enough to heat a house. Gas comes on and is blue what would be my next course of action ?


... Air Conditioners

I have dimmer switch controlled ceiling fan. What happens is the dimmer switch seems to works for a few weeks. Then it doesn't behave like a dimmer, but only as a switch - meaning that the fan gets on only at the maximum position of the dimmer. If dimmer is even slightly lowered from the maximum position, the fan gets off. This happened to a previous dimmer also and I have changed to a new one - but still same problem. What could be the cause?


It is better to switch over to the stepped switch type dimmer as the potentiometer( the control ) in these types wear off very easily.\012So when the carbon track loses contact the varation of the resistance to feed the SCR does not happen but ... Air Conditioners

I have a U-42 Janitrol gas furnace that will not start the exaust fan nor will it light the burner but the blower fan will come on. I have two identical units. I've swaped the exaust fans and the unit that was working strarted the other exaust fan - put the known working fan in the non-working unit and it still didn't come on. I switched the thermostats and still no positive results. Any suggestions?


... Air Conditioners

I have an intertherm central air unit in my mobile home that does not change fan speed when I click the fan speed switch. I've checked the fan relay which is good and energized in the ac mode which should put the speed switch in the circuit. It is a PSC fan motor and I haven't checked the capacitor.


You may ahve a bad switch but sometimes when they are worked on the servicrman bypasses the switch. Fan speeds are color coded black high blue med yellow med high and red low. Just for your info. Russ ... Air Conditioners

I have a Dometic 579 Series Brisk Air AC. The model Number is 57915.531. When I turn the fan on, nothing happens. If I reach up and turn the wheel blower the fan will start up and everything works. I replaced the fan motor and put on a new capacitor part # 3100248.412 was supplied. The fan still will not start on it's own. I still need to turn the wheel blower to get it started. Help!


My sheet shows part # 3100248.420 as fan run capacitor.You may have an updated number. Check voltage outputs labeled on it are same as on old one, and double check wiring is correct, to and from capacitor. Be careful not to mistake compressor start c ... Dometic Rooftop RV Air Conditioner

GOODMAN CMA80905CXBA FURNACE. INDUCTION BLOWER NOT ENERGIZING. GETTING 3 "BLINKS" FROM DIAGNOSTIC LIGHT (LOW PRESSURE SWITCH OPEN). THE A/C WORKS & THE BLOWER FAN COMES ON WHEN THE STAT IS IN THE HEAT MODE WITH THE FAN SWITCH ON. WHILE THE FAN IS ON , THE DIAGNOSTIC LED STILL BLINKS A CODE OF 3. THIS IS NOT A CONDENSING FURNACE. I BYPASSED THE STAT (W & R)TWISTED TOGETHER---SAME RESULT---DIAG LED COMES ON STEADY, THEN FOUR CLICKS, AND BACK TO THE CODE OF 3 BLINKS. CIRCUIT BOARD???? OR 120VAC NOT


The pressure switch is closed before the draft motor closes it.the board is telling you that this is not right.pull the wire(either) off of the pressure switch to see if furnace tries to light.if it does,you should replace the pressure switch. ... Goodman Air Conditioners

Blower fan stays running. Fan relay attached to small circuit board (coil tabs [timer?]). Capacitor on small circuit board had ''fallen out'' of ic board. Tried to get replacement board, and was sold just a standard relay - told that relay alone replaced the previous relay -and- circuit board configuration (?). Problem still exists (no change). Also changed thermostat just to eliminate as a possible cause, but seems like problem must be in the fan relay area. Question about the wires attache


... Carrier Air Conditioners

I have a horizontal magic chef gas heat/cool furnace (circa 1980) located in the attic. In the summer with the thermostat off and the fan switch on off, the fan on the unit will turn on all by itself when the attic temperature reaches around 100 degrees thus blowing warm air into the building. I have changed the thermost with same result. This fan is getting power from someplace. Nothing is on the wiring diagram showing a temperature switch on the unit. Where should I look to find what is cau


It has a thermister on it, but would recommend an attic fan will keep attic cooler and save money on cooling bills. ... Air Conditioners

I have an Amana a/c unit and the compressor outside keeps stopping however the fan goes on. The a/c service guys have been to my house 3 times and the wires each time were burnt. The last time they change the capacitor and and new heavier guage wires and it lasted for about a month. When trying to turn iton now I am back to the same situation. Do you think I should I go for a compressor or change the unit ? It is a 4 ton model BBC60a2A and the outside unit model number is RCE42A2A . Thanks


... Amana PTH123B35AJ Air Conditioner

Hello I have an LG window unit, model LWHD8000RY6 I hooked it up yesterday after having it in storage for the winter- dry, clean storage in my basement. It worked for about 2 hours, then the compressor turned off. The fan still runs, all of the display lights & switches function. I can hear the compressor trying to turn on, but it gives a quiet click-hum and then stops. The fan is still running, but no cold air. Any ideas?


... LG BG8000ER Air Conditioner

I have a LUX TX9000LC control, connected to a Carrier Model 394GA036100. The controls don't seem to control the furnace or air conditioning. The fan on the furnace runs continuously even when the switch on the control is in the off position. The only way I can turn the fan off on the furnace is to switch off the power to it. I put new batteries in the TX9000LC. No change. Thank you, Ron Casto


Ron, \015\012It sounds as though a "safety device" opened on your gas furnace......which shut off your furnace and has the fan running non-stop. Go to your gas furnace and look for manual reset switches......these switches typically have a smal ... Air Conditioners

My E.G. Air Cond.Compressor/condenser fan motor was replaced because it burnt; I replaced it with an O. Smith Electric Fan Motor. I also changed the capacitor. The new fan motor runs full speed for about 10 minutes and stops while the compressor is still runing. I need help to assure I have it wired corectly. I may need a manual which I do not have.


These motors have a wiring diagram on the motor. Make sure you don't have two different speeds connected together. ... Air Conditioners

I have a 2002 year model trailer, it has a Duo Therm Quick Cool High Efficiency by Dometic. Because the fan motor would not start by itself, it popped the breaker after a couple minutes the first time I turned it on this year. I took the top off the unit and give the fan a little spin and it would then run. Once again after a few minutes the breaker popped. I changed the capacitor for the fan but it does the same thing. Could it be the armature in the motor causing the problem? Any sug


Does the fan turn freely? Some oil might help but it sounds like you need a new fan motor. ... Dometic Rooftop RV Air Conditioner

Installed new Condenser fan motor on a split a/c unit fujitsu model AOU12C1 I also replaced the capacitor for it as well as the capacitor for the (run) on the compressor,compressor runs but...still fa


... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1761 seconds