Having problems with your Air Conditioners ?

I have a Maytag M6P09S2A Air Room Conditioner. I know that it was manufactured by Fedder's and they filed Bankruptcy. The unit works great however when we went to put it away for the winter the drain valve actually broke off all the way to the unit (the plastic inside the unit broke as well). I need to know if I can find a place that may sell replacement parts for these units.


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a Maytag M6P09S2A Air Room Conditioner. I know that it was manufactured by Fedder's and they filed Bankruptcy. The unit works great however when we went to put it away for the winter the drain valve actually broke off all the way to the unit (the plastic inside the unit broke as well). I need to know if I can find a place that may sell replacement parts for these units.


... Maytag M6P09S2ACOM Air Conditioner

Want to hack my AC so it runs cold air all the time or more than it does now, the cold air kicks on every now and then, but I want it to run all the damn time. Anyone know how I can mod the sensor or something to achieve this? Because I want my room to be an ice box. By the way it's a Maytag window unit works well when it's actually pumping out refrigerated air.


... Air Conditioners

Hi, I've an older but great friedrich Quietmaster SS12J10. The front grill is held in place by two separate white plastic holders that screw into the actual unit, that the grill then "clips" onto. I need to replace both plastic little units. Would you know where I can I find these parts? (Otherwise the front grill doesn't stay on.) Thanks very much. Elijah


Peace, As you requested here is a parts order #Toll Free 800-33837908AM -12 MIDNIGHT 7 DAYS A WEEK!If its in stock they usually get it to you next day if you ask!ngafmBless YouPlease rate my good servic ... Friedrich Air Conditioners

I have unit 48bne018301 mini split unit. For 2 summers now it is blowing a black substance almost like insulation all over, I have had the a/c man out 2 times and he has no idea. this substance is ruining everything it touches. there is no way to get tothe back of the unit under the coils, i dont know where to go. i am pretty upset since i feel something inside the unit is breaking down, and the reason i chose carrier is for the quality.please help. tel 252.261.5406. thank you


I have not heard of this in the Carrier mini splits, but sounds like you are on the right track, the back side of the indoor section is plastic and styrofoam, it could be breaking down. Did you check to see if the air filter is breaking down? \ ... Air Conditioners

B & D company air conditioner(model# 566DJ024-C) makes buzzing noise. I just bought a house and when I turned on the air...the unit outside makes a buzzing noise. The fans seems to work and cooler air is coming out of the vents(only ran it for a few min,didn't want further damage). I had the home inspected and the inspector said that the inside breaker is 30amps and the actual max for this particular unit is 25 amps. I don't know if that is the problem or something else...just thought I'd mentio


The circuit breakers Ampere rating has nothing to do with the buzzing noise. If you use a lesser Ampere Circuit Breaker it will trip every time the Air Con: starts, and if you use a very high Ampere Circuit Breaker it won't trip and give you the need ... Air Conditioners

I have an 1984 rudd 75,000btu forced hot air unit with pilot light, while cleaning unit an electrical connector broke off ! it looks like a blue plastic wing-nut, and It has 2 large black wires that go to the thermal cut off sensor. I dont know where it connects to???


The simple diagram for that specific problem it connected series to thermal cut off sensor.\015\012The two black wires, One came from a power supply line (it means an active power \015\012and the other one goes to the load motor) If you s ... Air Conditioners

I have a goodman Air conditioning unit CKL49-1. The fan motor connects to the top lid. Recently the metal cracked and broke and the fan fell down inside. I purchassed a new lid mounted the fan back on to the lid. It doesnt seem that any major damage was caused. I put everything back together the way it was. When I turn it on it will only go on for a sec then a switch inside turns it off. When i looked at the electrical on the ac i noticed when i turn it on a little spark on a switch and the swit


Sounds like it is overloading and tripping the circuit breaker (that thing that pops up). More than likely when the fan fell down it stopped the blade from turning which caused the motor to overheat, melting the windings insulation which caused them ... Goodman CKL49AR49 Air Conditioner

My Amcor Duo split A/C's compressor won't turn on. This is a new installation. Inside unit works and outside fan turns but compressor never turns on (no cold or heat). System passed pressure test and was evacuated well. Contractor doesn't know what to do.


... AmcorAire UCHW-H18AF2 Split System Air Conditioner

The heater is not working on our fujitsu AOT24U split system. The tray under the outdoor unit(installed inside factory above office) appears to have a gold/yellow oil in it.Is it oil from the compressor or refrigerent? Either way it doesnt look promissing! Can anyone shed some light on this problem and let me know what it will take to fix or if it can be fixed! Cheers Cold


... Fujitsu Air Conditioners

Bought frigidaire AC. Says remove INTERNAL packaging. I see styrofoam inside the unit but no way to get to it. Is it suppose to be there? I ask becAuse the side the syrofoam is on is near the air vent and does not blow cold air out as well as the side without styrofoam. Help!


That is the internal packaging they refer to, it should be a block of foam that is to be removed. You may have to take off the front cover to get to it. ... Frigidaire FAH085N1T Air Conditioner

AMCOR 24,000 BTU split system. Worked fine two years, then today it had no power. Checked circuit breaker, it had popped. Reset CB and went to inside unit - would not turn on or off with remote or hard button. Checked wiring with an electrical tester, and wires to outside unit hot, as well as inside unit. No flashing codes, nothing. Unit won't turn on,even with power. Is there a fuse somewhere in the inner unit or outer unit?


I had this same problem. I disconnected the thermostat wire out side at the condenser and reconnected it and it started working. A couple days later it blew the breaker again this time I found the bus where the L1, L2. GR wire connect at the condense ... AmcorAire UCHW-H24AF2 Split System Air Conditioner

I am trying to get some information on Intertherm unit on the inside of a Manufactured Home, With the new Hud requirements they are saying the out door unit must be installed by the manufactures installation instructions that comes with the indoor unit, my question is will those installation instructions allow you to install a Trane or a Rheme unit ? I know they will work but are they allowed by the Instructions? Would you know if the Trane or Rheme units are Hud approved ? Thanks for any help


Hi, since you live in a Manufactured home and not a R.V., I see no reason why you cannot go with what ever type of condensing unit you want to install on a slab outdoors. The installation instructions for the Intertherm unit for installing the outdo ... Intertherm Air Conditioners

Brand new unit have 3 ton inside and out but unit runs all day and will not hold temp i run my ac on 76 but as the day get hot the temp inside will not hold at 76 ARS says they dont know whats wrong but they installed the unit said i would have lower light bill but unit runs all day light bill 900 can someone help please with a solution


Call them back something is wrong if it is that new it is likely under charged. how big is your house square feet and what part of the country down south 400 square feet per ton if your house is more than 1250 square feet the unit is under sized ... Weather King 10AJA3601AH Air Conditioner

Our unit is now 6 years old. I have had a continuing problem with the fan unit rubbing on the enclosure. The only way I have been able to stop this is by partially unscrewing the top screws on the outside of the unit. The problem seems to be getting worse though, now I was forced to put a spacer between the inside and outside frame to force the inside unit away from the fan enclosure.


Is the fan actually hitting or could it be a vibration from the fan being out of balance ... Haier HWR08XC1 Thru-Wall/Window Air Conditioner

White plastic wheel on one side of the exhaust hose hook up hole spins/wobbles so the unit makes a very loud noise. Last time this happened to a previous unit it broke the plastic and the unit was useless. How can I fix this?


... Amana Portable Air Conditioner

I have a coleman evcon furnace a/c unit i have water in my floor which i think is a overflow from the cindensation line. i went uner my trailer and unhooked the rigid plastic line from the flexabile hose and blew out the rigid line. tryed to put a metal clotheshanger up the rubber hose line but only got so far. how do i get to the line from inside the house there are only 2 lines in the front 1 is the gas line and the other is the line from the a/c unit outside. unit inside is surrounded on 3 s


The front of the unit should lift up and off or pull straight out at the top (some are one way, some are the other) However, it sound like you can get to the outlet where the water should be coming out. May I suggest using a shop vac. I am a HVAC ... Air Conditioners

MY SHARP AF120FX ALSO DOESNT DRAIN AND THERE APPEARS TO BE NO DRAIN HOLE AND THE UNIT HAS ALWAYS BEEN ON AN ANGLE. THE UNIT FILLED WITH BLACK MOLD ON THE STYRO FOAM INSIDE TOP OF UNIT SO I SPRAYED IT WITH BLEACH N RINSED W SPRAYING WARM WATER INSIDE, THAT IS ALL IN THERE NOW AS WELL N NOT DRAINING... WHY DOESNT IT HAVE A DRAIN N HOW DO I GET WATER OUT?


Hi,Many newer units are made to retain the water and splash it onto the condenser coil...\012Clorox in the water will kill the mold and not hurt anything...\012You can carefully drill a hole if you want..heatman101 ... Sharp AF-S120FX Air Conditioner

I changed the fan motor because it had burnt. The capacitor was also changed. Recently, two months ago I had the unit serviced, which included the power washing of the inside and outside of the fins and roller. The unit worked well for two months. The unit presently is starting and tripping the main breaker fuse. The technician came and trouble shooted the problem and found that the wires going unto the compressor was burnt out, and corroded. This area has a cap on these wires as well as afelt p


Dear sir! First of all when water servicing any appliances,ask service man to check all loose wiring after service and also blow dry air near electrical ends to remove moisture or water drops.And also replace compressor contactor (Not relay) as ... Air Conditioners

My goodman ac unit is not blowing cool air inside, well not hardly blowing air at all but the outside unit is blowing cool air outside


... Goodman Air Conditioners

Not Cooling When I checked the unit outside, the fan is blowing cold air. Both, the unit inside and outside are runing well, but air flow in the house is not cooling. I took a look at the breakers, but they are fine as well. Can this be the compressor?


Yes, the compressor might not be running. Possibly a bad run capacitor or maybe burnt wires on the contactor or compressor flags. ... Weather King 10AJA3601AH Air Conditioner

Electrical diagram for model # e2eb-015 ha serial e2e9710-05442 replaced heat sequencer. Think heat and a/c running at same time. Inside coil froze up all the way to outside unit. Need electrical diagram for inside unit.


... Intertherm Air Conditioners

I have a air compressor that I know the fan is bad in the outside unit. The compressor is not turning on. Yesterday the only way that the fan would run is with a push, now today it won't run at all. If the fan is not at full strength, will the compressor turn on. I want to know if I need a new air conditoner or is there hope in fixing this unit...


There is definitely hope in fixing this one as long as its just the fan not working. Carrier can easily fix it for you if you want. If you are looking for any more specific information, I would be glad to help but I will need the model number of the ... Carrier Air Conditioners

Where can I find a manual for my coleman cam II central air conditioner for a mobile home? I recently purchased the mobile home and would like to know what steps to ntake to make it work at its best. Also, I find it puzzling that the air filter is set on top of the unit inside the mobile home. It looks to my limited knowledge of central air, as if someone set the filter on top of the unit because they did'nt know the correct location placement. Can you provide any comments or advice? Thanks


Check the website for Coleman/Intertherm for a manual, you will need the model and serial numbers of the unit. The filters for these typically sit on top of the unit, some come with frames, some lay directly on the coil. If you can't find a manual on ... Coleman Air Conditioners

NOT COOLING I AM HAVING A PROBLEM WITH THE UNIT. I HAVE WARM AIR BLOWING INSIDE, BUT WHEN I GO OUTSIDE TO CHECK THE UNIT THE FAN ON THE UNIT IS NOT RUNNING. I CHECKED THE BREAKER TO SEE IF IT WAS TRIPPED, BUT IT WAS FINE. I WENT BACK TO THE UNIT AND GOT REAL CLOSE TO IT. I CAN HEAR A LOW HUM NOISE AS IF POWER IS GOING TO IT, BUT THE FAN ON THE UNIT IS NOT TURNING. I PLACED MY HAND ON THE TOP CENTER OF THE UNIT, AND IT WAS REAL WARM. I DON'T KNOW WHAT THE PROBLEM IS. NEED HELP


A/c unit refrigerant charge is possibly low due to leakage, call a a/c engineer ! ... Air Conditioners

Hi. I have a LG heat pump/air conditioner. A split system with 2 indoor units. Model LMN095HV and LMN125HV. After a power failure by our local power company, I am getting a CH 05 error code. I have turned off th power to the units and waited several minutes and turned it back on with no luck. I know the code means poor or no communication with the outside unite. And I am getting the same code on both inside units. an you help? Thanks, Peter C [email protected]


Hi, this error is a communication error between your indoor and outdoor unit, check all wiring and connections - ch 5 is a communication error between the indoor unit and the outdoor unit.\015\012You can try turning the breaker off ... LG LSC183VMA Split System Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy