Having problems with your Air Conditioners ?

Outside unit does not run but fan continues to run inside blowing out hot air. system works fine for a while then the problem happens after system has ran for a while. water leaking from inside unit in house. unit is a coleman model #663CJ036-E. Any information we be helpful.


Answers :

Your system may have multiple power disconnects that you should check first. You should have 2 double pole breakers in your breaker panel, one controls unit inside and one controls compressor outside. Make sure you try to reset these breakers by turning off, then back on. Your unit inside may have a breaker on it and/or a disconnect also, make sure you check these. Your compressor, outside, should also have a disconnect that needs to be checked, some have a handle that you throw, up or down, and others have a plastic piece you can pull out and turn over to disconnect or connect. If you have the pull out piece, pull it out and make sure it's in good condition, not burnt or broken, if good, put back in. I don't know how carried away with diagnostics you want to get but, if you have a meter and feel comfortable with it, check for power at your disconnect outside. Then if you want to pull off side panel, check for voltage inside compressor where wires hook up. If you have power, turn it off and have a look at the condition of your wiring. If it looks good and you have power, I usually will try to replace the thermostat. If this doesn't work you may have a bad capacitor.
Water leaking inside could be caused by a break in the drain system pipes or, if you have a plugged filter, your unit could be freezing up. Make sure your filter is clean and check drfain pipes. If it is leaking inside, it doesn't sound like a freon problem because the unit is getting cold enough to sweat. You could also have a bad contactor inside the compressor.If the unit is freezing up after you clean your filter, check the cooling fins inside unit inside. If they are caked with dirt, you will need to clean them. They sell coil cleaner in spary cans at Home Depot, Lowes, etc.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Outside unit does not run but fan continues to run inside blowing out hot air. system works fine for a while then the problem happens after system has ran for a while. water leaking from inside unit in house. unit is a coleman model #663CJ036-E. Any information we be helpful.


Your system may have multiple power disconnects that you should check first. You should have 2 double pole breakers in your breaker panel, one controls unit inside and one controls compressor outside. Make sure you try to reset these breakers by turn ... Coleman Air Conditioners

Hi, I have a samsung aqv18ja series split type air conditioner (cooling and heating) wall unit. the unit was install in 02/12/2009. By "one hour heating and air conditioning". In this short time service the outside compressor has been replace, the system has check and recheck,for cooling leak. the inside unit fan motor has been change. but the problem still exists. The inside unit fan continues to run when the unit is "off" and with the remote off.


Simple, check in your remote. There is an option button "Blow". Just press it. Your unit gets completely off. Please write back if helpful? ... Samsung Air Conditioners

I have a Goodman Heat Pump System. When I turn the thermostat up to call for heat the outside unit starts and the inside unit(Air Handler) starts. However the inside unit only runs for about one minute then shuts off while the outside unit continues to run normally? Any ideas?


... Goodman CLQ36AR49 Air Conditioner

We have a weather king select 90plus not really sure of the model number but when we turned it on it was running fine then all of a sudden the outside temp was 90 and inside temp was 81 and it could get cool inside then we went downstairs and saw water at the bottom of the unit and the unit was sweating so we thought maybe it froze up,cut off unit for a while then cut back on and still water running from unit, company can in and said we have a leak somewhere and might need a new coil not sure th


Is this an upflow furnace? If it is, there needs to be a "P" trap in the condensate drain line. You need to check to see if there is. A "P" trap is a "U" shaped\015\012tube or fitting in the condensate drain line. The first time you run your un ... Air Conditioners

Ihave a l.g. lsu242he unit that is not working. The diagnostic light is fluttering and not giveing any code. Board has been replaced to no avail. Replaced board on inside unit. no change. condensor fan runs evan if inside unit is turned off. This unit ran perfect for aboutone month


Sounds like some of the low voltage wiring has shorted out. This will make the light flutter like that and will make the condenser fan motor run as well. If you replaced the boards and are getting the same issue, then the only thing is can be is a ... LG Air Conditioners

AC Condenser motor will stop at 1pm but inside unit is still running but no AC. If I turn the AC unit breaker unit off and then an hour later turn it back on. The unit runs fine all day until 1pm. Had a tech out and he checked the system and it's fine. He said I may have a thermostat problem and he would need to see the manual. My theromastat is programable (Carrier, 4 zone, Comfort II) with 3 remote temp sensors. How do I troubleshoot this?


I am having the same problem. The unit out side is off and I can have the thermostat off and it keeps blowing in the house. The weird thing is it turns it self on and off inside every 15 sec or so.. How can I stop this or why is it doing it? ... Carrier 38CKC060 Air Conditioner

Bryant air conditioner - outside unit will not run - before it quit running, air temperature in house rose from 65 degrees to 75 degrees. Inside fan continued to blow - air smelled like a car air conditioner that ran out of Freon. Bought Freon - need to know where to add it. The heat pump model # BF-163S bi directional but also coming from unit is another line that runs same direction with same type of valves. Air conditioner model # 697CN030 - B


... Air Conditioners

I purchased an Amcoraire split system unit for my 2 story garage. Licensced electrician did the wiring and licensed HVAC co. installed the 2 indoor units and outside unit. Outdoor unit is Model # AOM 243 HX 24000 BTU Indoor units are both Model #AWM123 HX, 12000 BTU each When I turn the unit on, it runs for about 60 seconds and then I get an error code on the inside wall unit that says P7. My manual says this has something to do with voltage. I had the power company come out and they show the


Since the manual says the error code has something to do with voltage it means the voltage is either too high or too low. And as the electric company says the voltage is within limits the the error is as a result of the voltage fluctuating. All you h ... Amcor Air Conditioners

Leaking water Ancient lennox central heat/air, to be replaced soon. However, has been running almost nonstop trying to keep up with the heat. Now I see water leaking from underneath the part of the central air unit inside the house. Is this dangerous, or just a nuisance I have to put up with until the unit is replaced in a week or two?


Sounds like ether you have a plugged condensate drain,or the drain pan is rusted out.If it it clogged you can squire a bit of water through to unclogg.If it is rusted youll have to wait it out.Good luck. ... Air Conditioners

I have a Champion Evaporative Cooler model WC44...I hear running water inside the unit when the cool modes are running. It is not a normal sound and has just started. There is no water leaking from the unit.


... Air Conditioners

Ac problems i have a goodman ac system. i can not get it to cool one side of the house. i have it turned down to 72 and the thermostat says it is 80 in the room. i can hear the return vent sucking air and the ac unit outside is running but no cold air is coming inside. the unit outside has cold air coming out the top when the fan inside it is turning


Hello from KOOLBREEZES, this is a simle problem and easy to fix. You have 2-lines going to / from your outside unit. a SMALL COPPER -line and a LARGE COPPER line with insulations. The fat line is suppose to have moisture on it wheres it,s not insulat ... Air Conditioners

Just cut on 8 year old Goodman CPLE24-1 AC for the summer. Ran 8 hours fine, Next morning noticed outside unit running, very little cool air blowing out of inside floor vents (like the blower fan was broken). Outside unit frozen. Capicitor replaced last July. (2) separate filters inside house returns clean. Whatz the problem? Help? Advice? Gotta fix it fast! By myself hopefully. Thanks!!!!


Due to the many different questions I see about Air Conditioning, I am including this overview to help us better understand each other for trouble shooting. A basic air conditioning system has a Thermostat, Air Handler or Furnace Fan and a Condensin ... Goodman CPLE24-1 Air Conditioner

I have an intertherm AC unit (model E2EB-015HA) and the inside unit is leaking and damaging my floor. We discovered this last summer and assumed it was a combination of condensation from the unit and freezing up. As it did freeze up and we caught it rather late. I did a good cleaning, filter replacment, and checked the line running out of the water-pan and it was not clogged and water was flowing well. I fixed some floor damage in my hallway and kept a close eye on the unit. This summer it has s


I realize this post is a few years old, but I keep having the same problem. Just got out from under my trailer draining water out of the insulation. I noticed when my unit was running that the water in the pan was being pulled back towards the insi ... Intertherm Air Conditioners

The outside unit is running but the inside blower motor will not come on. removed the blower and cleaned it up and plugged it in outside and it ran. the unit is 13 years old rheem crition unit. Where is the fan relay switch


There is no relay for the inside fanmotor.\015\012Switch the elektrical power off, then check the fuse on the inside circuit board.\015\012Goodluck! ... Air Conditioners

On our inside unit we have a serious problem. The condensation from the unit leaks down into the electrical system(being on the bottom) of the unit. I was told it was a design flaw. how do i keep the water from dripping on the electrical. Weve had to replace the electrical wires and boxes 3 times, have spent over $1000. Please help, we cant keep replacing the same thing.


U can try to get some good insulation wrap and wrap the coil box and also is the unit in a basement or attic if basement u can also ry cuttting a few vents in the dct down there like 2 6 inch by 10 inch holes and the unit wont create condenstaion i ... Air Conditioners

I have a goodwin ar36-1 central electric ac/heater that nothing is turning on at all. I checked the brerakrs but they are all on. i can not find any recet buttons or fuses on either the inside unit or outside unit. Is there a reset button or fuse for me to check on this unit? we were out of town for a couple days and the front door blew open.....so i am sure the heater was constantly running before the system comp-letely shut down. any help would be greatly appreciated! craig


Lol they usually don not have a true fuse in the disconnect box but a plug with a t handle that you pull out and flip over to disconnect the electricity and reverse to connect it. ... Goodman CLQ36AR49 Air Conditioner

I have a carrier 38YCBO48300 Over the years ithas a history of eating the start Caps Which I replace myself. This time the cap was leaking so I replaced it but the unit still will not run.The blower runs but not the outside unit. there is power and I hear a click when the system is turned on if I push in the relay the unit will start. but stop when I release it. I have checked the float switch in the condenser pan Any other ideas??


You must have a bad connection from either the thermostat or inside unit. Check the wire going from the outside unit to the inside unit. Look for any in-line fuses or the fuse on the circuit board. ... Carrier 38BRC048 Air Conditioner

Last night, the system began leaking substantial amounts of water, (condensation?) onto the closet floor where the unit is installed. The system has been running well all summer in this swelteringly miserable heat (+100 degree weather)in middle Ga. Is this a sign of coming failure or is it a normal reaction during these conditions? Your advice would be greatly appreciated!!!


Typical due to humidity. Is there a pan on the bottom to collect the condensate. It may have a clogged drain. ... Air Conditioners

The inside of my caravan smells of stagnant water and having elininated the water system I only have the ac unit to blame. Is this possible and whats the cure? When running the unit drips safely outside as its supposed to and does the job of cooling well.


Hello\015\012you may want to clean the ac coil with a mixture of bleach and water.\015\012\015\012Spray directly on coil,let sit for an hour then rinse with water. ... Dometic 57915531 Air Conditioner

I have a 2 year old Mr slim system inside unit MSY-A24NA, outside MUY-A24NA. "2 lights mode" stays on when temp in room is actually 4 degrees LOWER than set temp. This is new, operation used to be 2 lights dropped to 1 when room temp was 2 degrees above set temp. Humidity control also seems poor. Had 2 service shops here, they both confirmed freon is OK and since unit is running were uninterested in pursing further. Any guidance you can give will be a help


Check that there is not an abnormal moisture source such\015\012as leaks into the building or its wall or ceiling cavities from any\015\012other source. Check to see if the condensate drain from the air\015\012conditioner is producing water. I ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

What would cause a rooftop a/c unit to leak water inside the trailer only when the unit is running?


Hi,\012There is a drain to run the water outside and it is plugged...this units produces water when running as it dehumidifies the air...\012\012Here is a tip about trouble shooting your ... Dometic Rooftop RV Air Conditioner

Have a ge ac in window unit asto5 model leaks inside just recently . connot find any plug to pull for draining outside excess water inside ac cabnit . does it have one? been running this ac all summer and never have had a problem till just this week.


No drain plug but this model should have a SLINGER RING AROUND the end of the fan blades which picks up the water & sling it on the back coil which it is so hot & evaporates to help get rid of excess water .. So as for the water running ins ... GE Air Conditioners

On the primary side we have 208 1ph in the building the unit quit running when i got inside the unit the transformer was fryed. replaced old transformer and hooked the new to the orange lead which is 240 but it to burned up there is also oil leaking from the capacitor.


Replace the fuse in the plug. ... Air Conditioners

I have had a mitsubishi split system HVAC installed in my 150m apartment. It is installed inside the apartment in a small space with one window for inflow a second window for out flow. As we test the unit, 3 problems have come to our attention. (1) When it was really cold outside last Janaury the unit itself was leaking something that turned into ice. There was a pool of about 2 inches of ice on the floor and the wall had a covering and the hoses were encased in ice. The installer maint


The problem is in your Ac's compressor .It is wasting all the cooling gases and chemicals1)the ice you are seeing is the mixture of chemical & gases when get in contact with atmospheric air it converts into ice and pls dont touch that ice a ... Mitsubishi MS-A09WA Split System Air Conditioner

We have a 16 yr old basic 4 ton Carrier unit. Coolant was a little low when started it up this spring. Had it recharged but now believe there is a slow leak in the coil. Is this usually repairable? Could the compressor get damaged if it runs to low on coolant? And can the coolant leak fumes be harmful when inside the house? Thanks


If it has a small leak, it might be a pain to find but it is possible and yes it can damage the compressor. Also it can be harmful as it will displace oxygen. It's not combustible though. ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1119 seconds