Having problems with your Air Conditioners ?

Hoi... We have a Condura split aircon of 1.5 hp. 12.000 Kj/hr -R22 The in- and outset unit needs cleaning and has to be disconnected from each other. Here's my question: After connecting again and vac.sucking, how much Freon I have to add? Have I to add it by turning unit and what pressure I will see on my gauge.?I can repair my car air-con, have also tools gauges and pump but have no experience with split-aircons. Maybe you can tell me the way how to work after cleaning and connecting the un


Answers :

Hi Frans! I'm Roger. I have never had to disconnect the Evaporator from the Condenser to clean them but here is your answer. Use the access valves on the liquid side of the condenser. After evacuating, let the vacuum pull liquid R22 into the liquid line access valve to about 80 gauge pounds and close your refrigerant port on the manifold. Start the unit and add GAS to the suction port to bring your pressure up. If you have a scroll type compressor you can add liquid to the suction port but add gas just to be safe. Exactly how much you add depends on the efficiency of the compressor and how cold you want the discharge air to be. Normally we shoot for 34 to 40 degree evaporator with 18 to 25 degree temperature drop across the coil. R22 at 34 degrees is 60.2 PSI (Pounds per square inch) on your compound gauge. That's normally blue and on the left side of the manifold. The gauge that's hooked to the suction line. 40 degrees is 68.6 PSI. The amount it will take depends on the size of the condenser and length of your line set. Watch the amp draw on the compressor while charging. The name tag will have an RLA or FLA number that is the normal operating amperage of the unit. Add gas on till the suction line is cold at the compressor, then wait 5 or 10 minutes for the system to stabilize. Adjust you pressure again and you should be done. Let me know if you need anything else and if so, be as specific as possible. Roger

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Hoi... We have a Condura split aircon of 1.5 hp. 12.000 Kj/hr -R22 The in- and outset unit needs cleaning and has to be disconnected from each other. Here's my question: After connecting again and vac.sucking, how much Freon I have to add? Have I to add it by turning unit and what pressure I will see on my gauge.?I can repair my car air-con, have also tools gauges and pump but have no experience with split-aircons. Maybe you can tell me the way how to work after cleaning and connecting the un


Hi Frans! I'm Roger. I have never had to disconnect the Evaporator from the Condenser to clean them but here is your answer. Use the access valves on the liquid side of the condenser. After evacuating, let the vacuum pull liquid R22 into the liquid l ... Air Conditioners

I have a LG Multi type AC 9K BTU Std type Water leaking from UNIT into room, have checked the drain tube and unit is mounted level. and the grills clean The radiator panels under the grill are wet, Also the connection into the multi split outside unit is wet Please advise Alan Raybould


... LG LS-K2430HL Heat Cool Mini Split Air Conditioner

Daikin split cycle air conditioner FTXD50J heaps of water coming out of interior unit 1. Do I have to unblock drain hole on the interior unit or the external unit. Also dont have any compressed air 2. Also very whistley almost drowns out the TV can I lubricate the bearings? If so what do I lubricate it with and how do I get to them. 3. roller fan on inside unit is all gunked up almost solid with dust Can this be taken out and cleaned some how or how do I get it back to a new condition? many than


You will need to find where the unit is clogged and try and run something up through to snake it out. In regards to the whistling noise, this is usually caused when there is debris that has collected and the air is trying to be sucked through a prev ... Air Conditioners

Hi ...we have a split fujitsu air con for just over 5 years. The compressor in the outdoor unit is not starting up and the indoor unit blows ambient air. The operation light is lit and the timer light is continuously flashing when in use. Have reset the breaker and the units and also the remote to no avail. Can't find any info on the net or in the manual. Any tech help most appreciated. (Also doesn't seem to be a auto/manual reset buttn as such in the indoor unit)


There is a relay that the thermostat pulls in, in the unit outside. When this happens, the compressor pulls in and the unit outside will run. The compressor has to run before the unit will cool. ... Fujitsu 24C1 Air Conditioner

I have a sanyo split air conditioner unit. The indoor unit is a rs2422b and the outdoor unit is a c4822. The #26 led is flashing which indicates a communication error between indoor's main and sub unit. I checked and cleaned all the connections. The unit worked for a couple days, but now I am getting the same error code. Is there a problem with the board in the unit.


... Sanyo Air Conditioners

I have a Maytag S3BA-024KA Split System Air Conditioner. I have power to the system indoors and outdoors. The outdoor unit is clean and the Contactor is also clean with power going into it. The compressor is not running. I can push the contactors and the compressor fan will run but it will not operate by itself? Not sure what to do now.


... Air Conditioners

Split Airconditioner I have 18000 btu split type airconditioner, with R22 ,due to leakage it has lost all refrigrant ,I have all equipment to insert r22 my question is this do i also need to put oil in unit if yes then how much and how to put oil,can i put oil from suction side or is there any other way to do so ,kindly explain it to me comprehensively,Thanks in advance,my email is , Comment posted on Feb 24, 2009Rank: GuruRating: 87%, 26 votes You shouldn't have to add oil. The little bit that


You can add oil to unit from suction valve but you have to know how much == you have to remove the cmopressor drain it of oil and add the countity that wrighten on it between 500 and 750 cc appro as i understand your question when you know tha ... Cfm Daikin R410a Split System Air Conditioner

I have a Fujitsu Split air-con system - have power, but the maintenance and timber lights are flashing but unit not working - have cleaned the filters, changed the batteries to remote control unit.


I had the same problem with ast24rga-w which I resolved by removing the drain pipe from the outside and the use of compressed air towards the inside this made a bit of a mess on the ceiling which was cleaned with ease ... Air Conditioners

When turn on three eighth pipe freezes up air con does not blow cold air split system i also noticed the compressor is very hot even after the unit has been switched off.


This could be the result of a dirty filter, or in the case of no filter installed, dirty evaporator / condenser coils. The unit may also be low on refrigerant due to a leak and will need to be located and repaired before recharging. Refrigerants ar ... Mitsubishi Air Conditioners

I HAVE A LG LSK243C-1 SPLIT AIR CON AND IT DOES NOT OPERATE WHEN YOU TURN IT ON WITH THE REMOTE.I HAVE TRIED TURNING THE SWITCH ON THE CIRCUIT BOARD TO FORCED OPERATION AND ALL THAT HAPPENS IS THE MACHINE BEEPS CONTINUOUSLY.I HAVE ALSO NOTICED THAT THE FAN IN THE INDOOR UNIT TURNS SLOWLY INTERMITTANTLY


There are a lot of test variables to go thru for your unit. Since they are quite extensive, here is the service manual for your unit. It has a wealth of service information that will help you with the repair and any future problems you may encounter. ... LG LSC121PMA Split System Air Conditioner

We have a split system LG air con. Our local people cannot help us. The problem we have is that the unit seems to give off an offensive, unhealthy musky smell when not in use & also the temp when set at a certain degrees (eg. 23) within a few hours of use the temp drops to 19 deg or lower without lowering the controls.


There are two problems in your a/c. 1. Smell. 2. over freezing. The solution is 1.service the unit completely. 2. replace the room thermostat sensor. Sometimes, the room sensor may be working alright after servicing the unit. All the best. ... LG Air Conditioners

I have a maytag nmpeb08f2a portable ac, just started it up for the season. cleaned the filters and coils by wiping down . I also emptied bottom resevior. Im not getting cold air when on cool setting, tried lowering temp all the way. when i turn it on it will be cold for a short time, doesnt fell cold like befor, the temp will go down maybe 1 degree then, no more cool air. can i add refrigerant to this unit?


Frank, refrigerant is what it needs, but it should be done by a pro. Unless you have experience with this sort of thing, it's not a DIY project, ... Maytag Portable Air Conditioner M6P09S2A

I have a Tempstar 9000 airconditioning unit and while I was weed wacking I accidently cut a wire to the unit. I replaced the wire but now the unit wont turn on and also my furnace blower wont work even in the "on" position. I have a energy saver unit attched to the a/c unit as well. One wire connects to the a/c unit and the other to the energy saver. If I push the connector on the unit with the panel off the unit will run. Cansomeone tell me how to connect those four wires?


Hello TLOEKS You blew the transformer FUSE inside the blower unit! It should be a 5amp blade fuse like the one that goes in a car.It is located at the curcit board at the blower compartment.Replace that to restore low voltage power and every thing wi ... Air Conditioners

No cooling I received a call from my tenant that they have no ac. When i get my inspection of the unit to find an extremely durty air filter, which i replaced. Also i cleaned the a coil which was also full with dust. So i figured the time it took me to to do all that cleaning that the unit had time to reset it self. Long story short i still have no cooling at all still. through the first sequence of operation every thing seems ok . dtill no cooling


"You forgot the "first rule , check to see if everythings is working! If the filter was dirty , then you skipped the second line of defense to prevent dust from going into the vents is the squirrell cage blades. Air flows thru the filter first,,,2ond ... Goodman CKL36AR36 Air Conditioner

Condensation water is not draining properly on Goldstar AC window unit and backing up and dripping on the wood frame and floor below the unit. Is something blocked it just started happening. I am going to clean the little pipe that water drips from outside but it involves climbing a latter. Also I am going to clean the condenser coils...is there another reason or anything else I am missing and do you clean the condenser coils with little wire brushes? It occurs after the unit has been runnin


Yes,remove the ac unit from the window,and clean it out with a water hose out side,remove all debris from inside the unit,and tilt water out of unit.Make sure there is nothing in the way of the drain,and when the unit is put back in the window,make s ... Goldstar KG6000R Window Air Conditioner

We had a service technician come out and work on our a/c unit yesterday. He replaced the fan motor (only 2 years old) and insisyed that the fan blade needed cleaning. Next, he said we needed freon, but that the company policy stated that they would not add freon to a unit without first cleaning the coils ($188 for the cleaning). We have never had a technician tell us this before. Sounds like a way to make more $. Can you confirm if cleaning the outside coils is absolutely necessary before a


In short, yes, you have to have the outside coils clean before adding refrigerant so that you can correctly charge the unit. Dirty condenser coils will cause a rise in pressure inside the system because it cannot condense the refrigerant correctly. O ... Air Conditioners

I have an Energy Knight mini split unit. One works fine the other drips condensation EXCESSIVELY. Is something wrong in the unit itself or could the drainage tube be plugged inside the wall. If so, whats the fix? Also, I have another split unit and neither will turn on. This question was asked previously and it sounds like the fuse in the outside exchanger. Exactly how do I get to this fuse to check? Thank you.


... Comfort-Aire HMC24AD-1 Air Conditioner

I also have a grunaire dual zone mini-split that doesn't work worth a ****. I've had it looked at multiple times and had freon r410a added twice and still nothing. Without the high side - how do you know if you put too much or not enough. I also have a long run on one system being over 25ft from the compressor so its a longer run - but that one at least worked for a moment - the short run - never worked. Get the FC fault consistently on one unit - other unit just doen't blow cool - how do yo


An FC fault on a Grunaire is typically a defective PFC board in the outdoor unit or a Grossly overcharged system, where the drive cannot overcome the standing pressure to start the system up...the ONLY CORRECT way to charge one of these u ... Air Conditioners

E9 Showing on split unit display also blowing hot air not getting cold also unit outside is still running.


It is coz of Refrigerant leakge. ... Mitsubishi Air Conditioners

I have 3 Fujitsu heat / cooling multi split ductless units connected to one rooftop unit. Only in heating mode and only coming from the same indoor unit is a loud almost screeching/vibration sound. It can happen after the unit is on 30 mins or sometimes not until the next day. Repair techs are stumped as they don't see anything wrong and of course the noise doesn't happen when they are here. The noise is so loud I have to turn the unit off. Does anyone know what this could be?


... GE Zoneline AZ38H12DAD Split System Air Conditioner

After installing my klimaire mini split unit yesterday I heard the freon go through the unit and it worked great.Today when I turned the unit on the fan would work but the unit would not cool it also flashes a 7 on the led Could you please help me get the unit runing


For this you have to go into the the board located in the right side of the unit if your problem is what i think it is crosswire on the board. ... Cfm Klimaire KSWG009H113 Split System Air Conditioner

FUJITSU Air Conditioner Model AST24RGB-W is unable to switch on. Have checked safety switch and fuse on home circuit board and is OK. Power conected to outside unit is on and OK. Remote control has new batteries and display OK. Cleaned remote sensor panels on both remote and wall unit. ISSUE: When pressing the Start/Stop button the signal doesn't seem to be received by the wall unit. There is also no operation light on the Wall Unit. Unit does not turn on


What about the inside unit does it have power going to it. i would check the breaker for the inside unit. ... Air Conditioners

Unable to switch on. Have checked safety switch and fuse on home circuit board - OK Power on outside unit on and OK Remote control has new batteries and display OK Cleaned remote sensor panels on both remote and wall unit ISSUE: When pressing the Start/Stop button the signal doesn't seem to be received by the wall unit. There is also no operation light on the Wall Unit. Unit does not turn on


As per the problem which you mentioned it clearly indicates that problem is with the switch in the wall unit.but you mentioned that you checked the switch and it is OK.\015\012this means that the problem is with the main circuit control board o ... Air Conditioners

How do i connect my indoor air conditioner split wall unit to the breaker panel where is the indoor cord to connect to my electrical breaker


... Air Conditioners

E6 error I have a new Friedrich split A/C unit (ten days old). Just ran it for the first time and after a couple of minutes, E6 shows up on the display panel on the wall mounted unit. After some detecting, I discovered that the unit outside never comes on. The wall unit does blow but it seems to just be blowing air (yes, I have the remote set to "snowflake"...but the "snowflake" light on the display panel also turns off after the initial couple of minutes. I HOPE the problem is not in the wall (