Rudd central unit , turn A/C on[therm. inside] all U can hear is a Buzzing noise coming from the outside unit , found that [1] capacitor wire had been BURNT , changed wire , then changed capacitor , turned unit on[inside], 1st nothing ???? went inside & ck'd *breaker box* , fuse is operated by "dual arm[tied together] flipped off then on & went back turned a/c back on , came on for [maybe couple of minutes] then STOP'd , tried '1' more time , all U hear is the BUZZ noise? U could smell SMOKE & H


Answers :

Hello
\015\012Before you buy a new condensor fan motor check the contacts to the motor are not worn or pitted.
\015\012
\015\012Hold or push the contactor in by using an insulated screwdriver and see if the fan motor turns.
\015\012
\015\012Also the start cap you bought? was it the correct one meaning mfd micrfarad?
\015\012
\015\012If all the above checks out ok then you need a fan motor,you can wire the motor direct to check it also.
\015\012
\015\012From what you describe it sounds like the fan motor is burnt up and worn out,not uncommon.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Rudd central unit , turn A/C on[therm. inside] all U can hear is a Buzzing noise coming from the outside unit , found that [1] capacitor wire had been BURNT , changed wire , then changed capacitor , turned unit on[inside], 1st nothing ???? went inside & ck'd *breaker box* , fuse is operated by "dual arm[tied together] flipped off then on & went back turned a/c back on , came on for [maybe couple of minutes] then STOP'd , tried '1' more time , all U hear is the BUZZ noise? U could smell SMOKE & H


Hello\015\012Before you buy a new condensor fan motor check the contacts to the motor are not worn or pitted.\015\012\015\012Hold or push the contactor in by using an insulated screwdriver and see if the fan motor turns.\015\0 ... Air Conditioners

Hi, I have an 8,000 BTU unit. The unit is about 5 years old. It was running fine, no problems at all. Then whan I went to turn it back on after a few days-nothing. No noise, no air, nothing. It just did not turn back on. Before this happeend it cooled, it reponded to degree changes all was fine. The green light button on the test and retest comes on, but there is not a sound from the unit itself. Its like you would hit a power button that was not plugged in (but it is). This problem occur


After changing or cleaning your Filter, you need to reset the A/C. Follow the procedures below:\015\012\015\012Disconnect the power plug from the power supply.\015\012Clean the air filter.\015\012 ... Sharp AF-S80FX Air Conditioner

I have an Amana a/c unit and the compressor outside keeps stopping however the fan goes on. The a/c service guys have been to my house 3 times and the wires each time were burnt. The last time they change the capacitor and and new heavier guage wires and it lasted for about a month. When trying to turn iton now I am back to the same situation. Do you think I should I go for a compressor or change the unit ? It is a 4 ton model BBC60a2A and the outside unit model number is RCE42A2A . Thanks


... Amana PTH123B35AJ Air Conditioner

The fan on the Ruud furnice unit runs all the time but the Ruud ac unit is not kicking on . I know nothing about any of this but would like some Ideas what I might check. I went outside and could not find any kind of breaker on the outside unit. I do have a breaker inside and I turned it off and waited then turned it back on ..no change...


Some Ruuds have a red rubber cap reset button on the bottom of the unit or inside. Usually the fan quits and trips the switch. Or look at the metal run cap with 3 leads on it, if it looks bulged(concave on top) and not flat and sunk in, replace tha ... Ruud Central System Air Conditioner

NOT COOLING I AM HAVING A PROBLEM WITH THE UNIT. I HAVE WARM AIR BLOWING INSIDE, BUT WHEN I GO OUTSIDE TO CHECK THE UNIT THE FAN ON THE UNIT IS NOT RUNNING. I CHECKED THE BREAKER TO SEE IF IT WAS TRIPPED, BUT IT WAS FINE. I WENT BACK TO THE UNIT AND GOT REAL CLOSE TO IT. I CAN HEAR A LOW HUM NOISE AS IF POWER IS GOING TO IT, BUT THE FAN ON THE UNIT IS NOT TURNING. I PLACED MY HAND ON THE TOP CENTER OF THE UNIT, AND IT WAS REAL WARM. I DON'T KNOW WHAT THE PROBLEM IS. NEED HELP


A/c unit refrigerant charge is possibly low due to leakage, call a a/c engineer ! ... Air Conditioners

AMCOR 24,000 BTU split system. Worked fine two years, then today it had no power. Checked circuit breaker, it had popped. Reset CB and went to inside unit - would not turn on or off with remote or hard button. Checked wiring with an electrical tester, and wires to outside unit hot, as well as inside unit. No flashing codes, nothing. Unit won't turn on,even with power. Is there a fuse somewhere in the inner unit or outer unit?


I had this same problem. I disconnected the thermostat wire out side at the condenser and reconnected it and it started working. A couple days later it blew the breaker again this time I found the bus where the L1, L2. GR wire connect at the condense ... AmcorAire UCHW-H24AF2 Split System Air Conditioner

My unit is 4 years old. I always turn it off when I leave for work in the am and turn it back on when I get home in the pm. Last night I turned it on at 7:30pm. When I went to the front of the house about 45 minutes later, I noticed the unit outside was trying to turn on but would immediately turn off. I checked the breakers in the garage, turned them off and back on but still had the same problem. The fan inside the house is running but unit outside will not kick on. I looked for a magic


It could be a few things.. It could be the capacitor - which the most economical to replace first..\015\012\015\012If you are not really very mechanically inclined - get a trained pro to come out.. It is very dag ... Air Conditioners

One of my AC units froze up. I cut the unit off. after it defrosted I turned it back on soon after we smelled wires burning. I turned the unit off. Now when I turn the unit on the outside comp. goes on but the air handler will not turn on , I checked the low volt fuse it is fine and ther is no reset switch, what could have happened there are no burnt wires inside the air handler.


You may have a couple of problems now. The original issue of icing up is most commonly due to low refrigerant in the a/c. For this you will need a professional to correct.The second problem sounds like it may be a bad capacitor for the in ... Air Conditioners

I have a Frigidaire cooling and heating unit. Last night we had freezing rain and ice. I heard a weird noise coming from the unit then smelled a burning smell. I turned the unit off. The top vent outside was covered in ice blocking air flow. I cleaned off the ice and turned the unit back on and it just makes a humming noise. No air is blowing and I looked inside and the fan is not turning.


Sounds like the motor burned up when the ice blocked the air which it was not able to cool the motor it will need to be replaced. (the motor) ... Air Conditioners

I have a ruud model no. ubhc-17j11nfd and i am having a problem with my heat. when the heat does come on, the thermostat says it is on auxilary heat. the blower in the inside unit does not run. i changed the capacitor and now i get a really loud humming noise. the motor still does not spin. but when i spin the motor by hand then it seems to work fine.(the humming goes away) this happens every time when the heat goes off then back on. the only way to solve this is to keep the fan on constantly.


... Ruud UBHC Air Conditioner

RV ac fan runs backwards (blows out air on top of RV.) Runs correctly sometimes but after it satisfies and clicks off when it kicks back on, it runs backwards. The only thing that will turn it back around is to turn off unit and wait for around 30 minutes and turn back on. (won't reverse motion very quickly) Spoke to Coleman expert and was told it is the fan capacitor. Need instructions to identify and change the capacitor. Would like to fix myself since this will be the 3rd time to have it i


Hi, this is strange as I have never heard of this either!!! The capacitor is located by the motor and sometimes clamped to the motor. They can be the shape of a very small can, oval 3" tall with 2 leads on top with wires coming off the terminals. It ... Coleman Mach III Air Conditioner

I changed the fan motor because it had burnt. The capacitor was also changed. Recently, two months ago I had the unit serviced, which included the power washing of the inside and outside of the fins and roller. The unit worked well for two months. The unit presently is starting and tripping the main breaker fuse. The technician came and trouble shooted the problem and found that the wires going unto the compressor was burnt out, and corroded. This area has a cap on these wires as well as afelt p


Dear sir! First of all when water servicing any appliances,ask service man to check all loose wiring after service and also blow dry air near electrical ends to remove moisture or water drops.And also replace compressor contactor (Not relay) as ... Air Conditioners

My air condition inside unit seems to be freezing up and the air stops blowing through the vents after I turn it off it sounds like ice melting. after a few hours I can turn it back on ,it will blow throuh the vents again there is a fan on yhe front of the inside unit it is making noise. is that a exhaust vent not the one that blows air through the vents. how can I fix this myself


When does it make the noise, when on AC or heat?? 2 things if the fan is on the ac unit itself that's not the one that blows air thorugh your vents, if its the one inside the furnace that is the one that blows air through your vents, but remember th ... Goodman CKL60AR60 Air Conditioner

I wired the unitfrom the outside breaker box,on the inside unit i have a switch that cut the power to the unit and turns it on.when i turn that switch to on my unit started making noise like it trying to run so i turn my thermostat to on my heat acts like its coming on and then my transformer blows.this happen twice


It may be wiring is wrong.Make sure the ground goes to ground, and the other 2 , 110 volts each, go to correct contactor poles. ... Ruud UBHC Air Conditioner

We have a weather king select 90plus not really sure of the model number but when we turned it on it was running fine then all of a sudden the outside temp was 90 and inside temp was 81 and it could get cool inside then we went downstairs and saw water at the bottom of the unit and the unit was sweating so we thought maybe it froze up,cut off unit for a while then cut back on and still water running from unit, company can in and said we have a leak somewhere and might need a new coil not sure th


Is this an upflow furnace? If it is, there needs to be a "P" trap in the condensate drain line. You need to check to see if there is. A "P" trap is a "U" shaped\015\012tube or fitting in the condensate drain line. The first time you run your un ... Air Conditioners

A/C worked fine last year. Turned it on for the first time this year and the outside unit does not come on. The inside unit fan works just fine. I checked the circut breaker and turned on and off. No change. I revoved the cover and do not see any burnt wires or any problem. Not sure what to do next. I have a meter... what should the voltage be where the power comes into the unit at L1 ect. please help... thx


Check and see if you have 24volts at the contactor outside.if you do you have a bad contactor. if you don't take the tstat off the wall and take a jumper wire and jump out R to Y on the t-stat if i ... Air Conditioners

My LG LSN182HE will not turn on using remote or the one button. I check fuses and breaker and they are fine. Power is coming into the inside unit but nothing happens when I push the power button. I turned it on AC mode and it started running. When I went back into the room later the unit was off.


You should check the condition of capacitor, there may be a small transformer inside the unit, check it for 24vac. If your problem still exists then you can contact with LG technical support at ... LG LS-K2430HL Heat Cool Mini Split Air Conditioner

Hello,im charles we have a jbs unit ducted unit the indoor turns on but the outdoor does not. i have put new capacitors and by pass the contactor, but i get a humming noise out of the compressor and the fan does not turn. I think it the compressor but dont want to change it if i can make it work. what else can i do? its a sanyo 10kw compressor .


You can try a hard start kit that can be purchased from an a/c supply store. This hard start kit adds a little extra boost of power to the compressor that in the event the com,pressor is wanting to be a bit stubborn when turning on this kit will ass ... Air Conditioners

OK I am a dumb A--. I did not turn the power off to my Payne PG9MAA Condensing Gas Furnace. Also A/C. In my futile attempt at relocating the thermostat. I 1. did not turn off the unit 2. I did not have enough wire so I spliced in a new longer one. 3. Voila' there is absolutely nothing on the thermostat showing power. I used the voltage regulator and put the contacts one on red and the other I went in sequence to all the other wires and it read 11.00 or so volts.. If I changed the (lead) or


Depends if its a 12 volt or 24 volt system and if your meter is reading right also check meter then check red wire if its a 12 volt thats what you should have and 24 so on or you have a dead short good luck with that one just be calm a go thru all t ... Air Conditioners

Fan make a flapping noise when turning . we cleaned the unit inside the house and out. the unit started back cooling for about 1 hour, then the motor outside got hot and the fan started making a noise like a flapping sound


CHECK FREON LEVEL, CAPECITOR FIRST. PUT WD40 ALONG THE SHAFR OF FAN AND LET IT SIT FOR A WHILE. THIS WILL REMOVE RUST. ... Coleman Mach 15 Air Conditioner

8 year old Air conditioner only used in the last 3 years more than a week or two a year. capacitor changed last year Unit was working a week ago now fan is not turning, Connector clicks when turn on and off. when on I turn fan manually to see if motor might kick in and it does not. No lose wires. Quiet when turned on.


Outdoor units require there own power supply, check the breaker panel and the fuses in the disconnect switch box next to the unit if there are fused, If the capacitor that was changed last year was not the right rating or configuration it may need to ... Carrier 38CKC036 Air Conditioner

I have an Amana Prestige A/C compressor that is not turning on when my fan turns on to cool the house. I replaced the capacitor because my old one was bubbled up at the top. After I replaced it, it still did not kick back on when I turned on the A/C unit from inside. There is an override switch on the compressor that turns the compressor on manually but does not stay on.


... Air Conditioners

I changed my fan motor and squirl cage blower hooked all wires back like they were fan is not turning fast so the compresser is heating up. the old motor the motor mounts went out that why i changed it


If you have changed the motor, I assume that the RPM is the same as the motor you have removed.?\015\012Check the rotation of the new motor, if you have it turning in the wrong direction, it does not matter how fast it turns, it wi ... Dometic Rooftop RV Air Conditioner

Thermostat inside went up to 78 degrees which was set for 73 degrees. I checked filter filter was clogged. I cleaned filter. However could not get outside unit fan to go on even after turning off for 20 min. Also circut breaker was turned off and back on.


DID CIRCUIT BREAKER TURNED OFF BY ITSELF?\015\012If it is, there was too much circuit load, or compressor might be too hot.\015\0122. check outside unit fan, fan capacitor and compressor capacitor and CONTACT SWITCH.\015\012FAN IS A ... Air Conditioners

I have an XB10 Trane AC unit that was installed when my house was built in 2003. After running it for a while, the compressor either seems to shut down and I notice no cold air as though its just the fan. Sometimes when I start it back up my thermostat says ''wait''. Or it just blows the fan, even though its set for cold. I've had the capacitor replaced, a start up capacitor bridged to it. I've changed the filter and had the coils cleaned with a brush and garden house from the inside. I'v


... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1355 seconds