EA message on unit it a manuflow split KFR 35gwz/bm outdoor unit dont start


Answers :

EA Outdoor four way valve defect.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

EA message on unit it a manuflow split KFR 35gwz/bm outdoor unit dont start


EA Outdoor four way valve defect. ... AmcorAire UCHW-H12AF2 Split System Air Conditioner

SAME PROBLEMS 18k btu mini-split sys turn on blowing cold air for 3 mins, then turns warm for 3 mins then shuts down however the run lite blinks at 4 times intervals. outdoor unit fan alway runs at slow speed, even at start up. cleaning outdoor fan cleaning dont help. whats next? maybe the caps? thanks mike (us navy) at [email protected] in norfolk,va FAN MOVES FREELY, EVEN BY WIND BLOWN.


Glad to hear the issue is resolved.\015\012\015\012With regards. ... Air Conditioners

I have a 24000btu ramsond split system. running for a yr, had to change out fan condensor and capacitor. now the problem started when we noticed the outdoor unit was shaking like a washing machine. then it dosent blow cold anymore. i checked the capacitor for compressor, which showed no ohms. i swapped that out and it says that it has 3.8 ohms, but when i put the meter on the ohms symbol )))), it makes that constant ring, which my father in law say is straight shot to ground. so now i dont know


Hi, you can get a proper reading with a ohm meter when checking a run cap. All it will tell you is that the capacitor is not open internally inside if you have the ohm setting that sounds off. Its not ground or shorted to ground, but look on your met ... Air Conditioners

I have carrier split unit the problem is the when switch it on indoor unit runs but when outdoor unit runs it make cool just for 5 mins and all unit indoor and outdoor go shutdown and green light start blinking and after 5 mins unit starts again after 5 mins again shutdown . any sugges please.


... Carrier 38CKC036 Air Conditioner

LG split (3 indoor) LMU360CE system. The fans on the outdoor unit start and work. The compressors do not start-up. There is no error code on the indoor unit. On the outdoor unit the error code is continuous flashing of green LED #2. Any suggestions.


The LED #2 is only flashing while in disconnection or short in Thermistor (3 sec off / 0.5 sec on). If you want to change it, note: this is not an easy job to do! You will need to remove the top panel, then remove the control paneland then the front ... LG LMU360CE/LMN120CE Air Conditioner

I have a Sanyo Split System the indoor unit is a KHS0921 and the outdoor unit is a CH0921. When i first turn the indoor unit ON the fan will run for a few minutes and then go off. The outdoor unit never comes ON when there is a cll for cooling. The only way to get the fan to come ON again is to turn the breaker OFF and then back ON. The Operation loght will come ON when the fan is running but it will start flashing when the fan goes OFF. What should i look for?


... Sanyo Split System Air Conditioner

I have a AOBR12JGC outdoor unit. I start the unit everything goes normal, but after a few minutes the compresor tries to come on , but it cant. No error messages nothing. The A/C has ground. the unit is 6 months old. I have change indoor unit circuit board, outdoor circuit board and the compressor is OK. Any idea?


... Air Conditioners

I have the Mitsubishi split unit system with 24BTU for my bedroom, the problems starts after the compressor has started and the cold air has been blown through the indoor unit, this pleasure lasts for about 2 mins and then a strange sound from the outdoor unit , sounds like the power is getting low or some what, then it shuts itself down. A technician checked and said the compressor needs replacement..its 12 month old and works 6 hours a day!!!


Ok, it can be two things. \015\012\015\012The outside unit needs to be washed with a water hose to rinse any dirt and debris that can cause a restriction in airflow over the outdoor coils. If they are allowed ... Mitsubishi MSM18NW Air Conditioner

I have a problem with split-type ac unit, when the unit stops due to cooling, the unit doesnt turn on to cool operate again. I have to set the control to start the unit again. Someone recommends me to change the capacitor of the outdoor control unit. Or maybe I have to replace the a/c unit?


First of all I would change out the thermostat since you say you have to turn the unit on at each use. The capacitors only assist in the start of the compressor and fan. You main issue seems to be the activation after the unit has been off. I thin ... Carrier BCA101R Air Conditioner

Lg split ac outdoor unit delayed start


Acctullly when indoor unit on then outdoor unit take 3 to 5 minut taking on. and secondly when indoor unit regain its temoerature as we set on indoor ac then it trips the out door unit.when 3 to 4 degree exceed the temperature then it again s ... LG LS-K2430HL Heat Cool Mini Split Air Conditioner

Hi. I recently installed 1.5 T, 3 * Split AC, LG. Whole day the AC works fine and no problem in cooling too. But once in 2 day outdoor unit start making thudding noise continously and does not stop for 4 to 5 second and after that indoor unit stops cooling and just fan runs. No cooling is done after that and room temperature keep increasing. The green LED of compressor in indoor unit is ON, compressor does not work. To achieve cooling again I have to switch off whole unit for like half an hour a


HelloSounds like the compressor is shuting down on high heat.There could be a couple reasons for this.1 Check that proper voltage is being supplied to compressor.2 Freon level may be low.This would be a service call.3 Ba ... LG Air Conditioners

Hi ...we have a split fujitsu air con for just over 5 years. The compressor in the outdoor unit is not starting up and the indoor unit blows ambient air. The operation light is lit and the timer light is continuously flashing when in use. Have reset the breaker and the units and also the remote to no avail. Can't find any info on the net or in the manual. Any tech help most appreciated. (Also doesn't seem to be a auto/manual reset buttn as such in the indoor unit)


There is a relay that the thermostat pulls in, in the unit outside. When this happens, the compressor pulls in and the unit outside will run. The compressor has to run before the unit will cool. ... Fujitsu 24C1 Air Conditioner

Lg Neo plasma inverter split model s18ahn isn't heating or cooling properly. When in heating mode air con will go into defrost/preheat mode for 5 minutes and then air con will blow out air for 5 seconds and then go back into defrost/preheat mode. When in cooling mode indoor fan will pump out air but will not get cold. In both heating and cooling modes the outdoor unit will not start up and the outdoor fan will not spin. I have just replaced the main pcb board and that hasnt made a difference. Bo


... Air Conditioners

Hi, We have two Paragon split systems which effectively cool our large home. One system is playing up. It started 3 days ago where there is water dripping from the front of the unit and the green 'run' light is now flashing. I tend to think it's blocked somewhere, buy my husband cannot find where to check this. Our outdoor units are both under the house with very effective ventilation but the last 3 days have been extremely humid, however the other system is running perfectly. Any ideas? Thanks,


More then likely the blockage is inside the a-coil section. At the drain. To get to it easier remove the pvc drain line. As the drain line comes out of the collection pan it goes into a pvc line the 90 degrees elbow goes to floor. So cut the lin ... Air Conditioners

I have a lg 1.5 ton split ac , problem is compressor trip in 5 to 10 minutes ang agin start in 10 min..i will call service centre , he wl change capactor and service indoor n outdoor unit ,but problem will same, then he will say the problem in relay (pcp) circuit. tell me solution..


First check the compressor amps and the condenser fan rotation are correct if ok check power come to the compressor without interuption (from control in the indoor unit)if the remote setting are ok correct voltage to the compressor may high pressur ... Air Conditioners

Well when I try to turn it on, nothing happens but only red and green light start to blink. The outdoor and indoor unit do not run. Its a three phase electrical connection and they are ok but the split does not run only the light keeps on blinking.


How many blinks look at the diagnostics troubleshooter usually on the panel of the unit, then determine the problem. ... LG Air Conditioners

I have an lg lsk182v-3 split ac which has 5 flashes on the power light and won't start the outdoor unit can any body help please


... Air Conditioners

My split ac outdoor unit on starting cool but after some time it overheats and then trips off


... Air Conditioners

E5 error message on tempest split unit air conditioner Model KFR 25GW


... Air Conditioners

Fan nor working on the outdoor unit.Hisense HFR 0922 split cycle air con. Double checked the wiring and is OK according to instructions in manual. Compressor working, but fan won't start. This is the second unit we have intalled. The first one replaced straight away by ''The Good Guys''. Replacement appears to have same problem. Beginning to suspect we've missed something in the wiring? Has anyone experienced the same problem please?


Check capacitor and the fan control board. Do you have active and nutral from the board or does it get power from the comressor contactor? ... Air Conditioners

Domain Air Split system KFR-70GW/c will not start in either Warm or Cool mode. The External unit fan rotates but there is no compressor activity nor any internal fan operation. Can you please help me to fix this problem?


... Air Conditioners

Trane split air conditioning -XIL 14 MODEL- no cooling , condenser unit blowing cool air, compressor comes on once after start up and then dont't come on after that , condenser fan working


Shot of freon or loose signal wire between condenser and wall unit ... Air Conditioners

I have a Fujitsu inverter split system,outdoor(AOTZ24LBT). When I start it up, the red operation light is off and the green light flash twice every 10 seconds.The fan indoor unit is working but the co


... Air Conditioners

Fujitsu inverter air cond. just stopped working properly. Model outdoor AOT30PMAL, indoor unit AST30PBA-W. Code oper. red led flashes fast continously, green led (timer) repeats 13 slow flashes. After power reset, it takes rem. con. commands, however, while inside it looks normal, the fan in outdoor unit starts but compressor only makes attempts to start. After a number of series of 3-4 starting attempts, it stops and fan stops. Three way resistance test does not indicate open or short circuit c


Hello, my name is Heath and it will be my pleasure to assist you. Try using a hard start capacitor on the compressor. It sounds like the compressor is having a hard time starting and overamping the circuit. If you get a hard start capacitor it may he ... Inverter Air Conditioners

Fujitsu inverter air cond. Just stopped working properly. Model outdoor AOT30PMAL indoor unit AST30PBA-W. Code oper. Red led flashes fast continously green led (timer) repeats 13 slow flashes. After power reset it takes rem. Con. Commands however while inside it looks normal the fan in outdoor unit starts but compressor only makes attempts to start. After a number of series of 3-4 starting attempts it stops and fan stops. Three way resistance test does not indicate open or short circuit compress


It sounds like your inverter is at fault. You will need an inverter tester ( most good service techs will have one ) to prove that the output to the compressor is correct. If the inverter is okay then it will be the compressor at fault with a locatio ... Air Conditioners