Having problems with your Air Conditioners ?

I have a Trane Heater/AC unit no heat pump with a thermostat model 802AS32DAA that has seven wires. I am going to a five wire heating/cooling thermostat. What do i do with the two extra wires? old thermostat red wire-RC slot (24 V from A/C) white wire-W1 (???) yellow wire-Y (A/C Compressor) green wire-G (A/C Fan) black wire-B (?????) Blue wire-Y2 (????) orange wire-W2 (24 V to Furnace new thermostat therminals G Rc Rh Y/O W/B Y1 Can you tell me what wires to connect to each


Answers :

From Honeywell : "If your old thermostat had Six or more wires, the replacement you have is Wrong!"

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a Trane Heater/AC unit no heat pump with a thermostat model 802AS32DAA that has seven wires. I am going to a five wire heating/cooling thermostat. What do i do with the two extra wires? old thermostat red wire-RC slot (24 V from A/C) white wire-W1 (???) yellow wire-Y (A/C Compressor) green wire-G (A/C Fan) black wire-B (?????) Blue wire-Y2 (????) orange wire-W2 (24 V to Furnace new thermostat therminals G Rc Rh Y/O W/B Y1 Can you tell me what wires to connect to each


From Honeywell : "If your old thermostat had Six or more wires, the replacement you have is Wrong!" ... Air Conditioners

I have a carrier air/heating unit with pump. It has 8 wires. Brown,blue, white, yellow, green, black, orange,and red. I'm trying to install honeywell thermostat. The wires from my unit are suppose to go into these honeywell (RTH3100C) thermostat slots. hONEYWELL WIRE SLOTS E Aux Y G O L R B C The only thing i have to go on is the wire colors from my wall which were not labeled or coded in any way. I am not sure about the model# of our unit because it is so old that the model# has faded away the


Turn the power off to the air handler. Open the control cover. Write down what color wires go together at the wiring terminal. All 8 wires are probably not used.\015\012Post the findings here.\015\012In most cases,\015\012E= brown-e ... Carrier Air Conditioners

I have an older Carrier Heat Pump which I am trying to update the thermostat control with a Hunter model 44550. The problem is that the wiring to the current thermostat is as follows, G= green wire, R= red wire, W2= blue wire, O= orange wire, Y= yellow wire, E= grey wire and C= white wire. If I am reading the schematic correct for the Hunter thermostate I am to wire as follows Green to G, Red to RC, Blue to W, Orange to O, Yellow to Y/Y1, C cap it as batteries are used. It does not tell me


JUMPER STAYS BETWEEN RC AND RH SO YOU HAVE INCOMING POWER FOR BOTH COOLING AND HEATING. THE WHITE WIRE YOU SAID C IS COMMON AND SHOULD BE USED IF POSSIBLE TO COMMON TERMINAL ON NEW STAT . IF THERE IS NO COMMON, THEN CAP IT BUT YOU'LL BE CHANGING BAT ... Carrier Air Conditioners

I have a Janitrol Heat Pump Thermostat HPT-18-60 and need assistance connecting my new Honeywell RTH7500D thermostat I have a Goodman Heat Pump System Indoor Unit Model#AWB24-05C REV D Outdoor Unit Model#CPLE18-1 Here is the wiring of the old thermostat Y-Yellow Wire G-Green Wire R-Red Wire O-Orange Wire W2-White Wire E-Blue Wire C-Black Wire Where should each of these be connected to the new thermostats terminals?


... Air Conditioners

Thermostat wiring I have a Frigidaire Model R4GA FWA and Central A/C system. I am trying to replace the thermostat with a programable Hunter model. I do not have the original wiring diagram and the old thermostat is no help. The wiring colors I have is Green, Red, Brown, Yellow, White and Orange-(not used). The terminals on the new thermostat are RH, RC, Y/O, W/B, G, and Y1.


Your best bet and where i would start is to identify where the coulors are conected at the fernace. in the industry we use standard wireing coulors wher green is g for fan and red is rh=switched trans power for heating . rc=switched transformer pow ... Air Conditioners

I am replacing a white rodgers thermostat with a honeywell rth3100c. i have matched my wire as e (brown) to e w2 (white) o aux y (yellow) to y g (green) to g o (orange) to o l blank r (red) t r b blank c blank now i have a blue wire which was hooked up to the x1 on the old thermostat. where does this wire go?


Blue (C) or sometimes (B) should be your common wire. Look at your schematics and locate common. Your Brown wire is (E) and is emergency heat, white wire (W) is Auxilary Heat, green wire (G) is fan relay, red wire (R) is power, yellow wire (Y) is C ... Air Conditioners

Changing from a Trane Weathertron Heat Pump thermostat to a Honeywell TH5220D1003. The Trane unit had a white wire, green wire, red wire, orange wire, yellow wire, blue wire and a tan wire. Where do they go on my Honeywell TH5220D1003


... Honeywell Air Conditioners

I have a tempstar with 6 wires. Green, Blue, Red, Yellow,White, and Orange. I am trying to install a White Rodgers 300 thermostat and letters are not matching up. The thermostat has G, A, RC, RH, O, B, Y, and W. I don't know where to hook the blue wire which was labeled C. Unless it goes to RC and the red goes to RH could you please help? Thanks


You need to verify the function of each wire with Tempstar then cross it with the WR stat. Call the techline if you need further assistance 18002842925. ... Dometic Rooftop RV Air Conditioner

Replace thermostat Purchased a HUD home and some one took the thermostate with them when they left, carrier model 38byc048340, but I'm not sure of the wire color codes the wires i have are listed below. Does carrier have a standard color code for the thermostat? white yellow red brown green orange blue


Typical color codes in Florida are;\015\012white to W1 for heat\015\012yellow to Y for compressor\015\012red to R-RC-RH for power in\015\012brown to W2 and or emergency /auxillary heat\015\012green to G or Fan\015\ ... Carrier Air Conditioners

Rheem Model RQNJ-A042JK Heat Pump Unit wired to a protech 520 Thermostat. Everything OK in auto mode. Fan will not run in on mode. All wiring connected except orange and black. Do not have original manuals for either unit. Installer went AOL and out of business without leaving me the manuals. Anyone have a solution. I know that Rheem is notorious for their wiring color tricks and I do not want to screw something up. Here is the wiring as it is now: Red - R Blue - B Yellow - Y White - E Jumper -


Connect the orange to the o terminal.\015\012Dave ... Air Conditioners

I installed a new Honeywell Programable thermostat, When I turned on the AC it turned on the Heater... I followed the wiring but some of it is not making sense... G=Green, Y=Yellow, R=Red, C=Blue, W2=White, Y2=Brown... The problem is that I have an Orange and Black Wire left over, Which one do I connect to W? and do I have the wiring right... my unit is a central Heat & Air, not a heat pump.


Hi, the problem is you have bought the wrong thermostat for the unit if it is not a heat-pump. A heat pump will have W-1, W-2 for heat strips, and Y-2 is for 2nd stage cooling. G is Green for Fan, R is Red for Power, Y is Yellow for cooling, and W wo ... Goodman Air Conditioners

I have a hunter programmable thermostat model #44155c and Im trying to wire it to my goodman furnace. Its a 7 wire system with a white,yellow,red,green,brown,blue, and orange wire. The ac works fine but the heat wont shut off. Thanks


Make sure you do not have a jumper between the red and the white. Also make sure the wire is not hanging out from behind the screws. If the heat stayes on no matter what you do. The red wire has to be touching the white somewhere. \015\012The r ... LG LSC183VMA Split System Air Conditioner

At condense unit the diagram on the board has C,Y,O,W2,R on it.I just change the unit and the wires are confusing me. On the thermostat the wires being use are the R-red,W-Orange,Y-yellow,G-green,Y2-White.This is a heat pump unit.


Hi,\015\012\015\012Here is a tip that explans the wiring and the color designations...\015\012\015\012Thermostat Wiring a ... Air Conditioners

Changing out an old mercury thermostat to a digital thermostat. The old therm. has Y=yellow, G=green, R=red, O=orange, C=blue, W2=white and E connected by jumper. Extra wires are black and tan. New therm. has W,Y,C,R,G,O,E. Any assistance appreciated


Y=yellow (a/c)G=green (fan)O=orange (reversing valve)C=blue (common)R=red (hot)W=white, jumper to E (emergency heat) ... Amana Air Conditioners

My old thermostat has 8 wires, red, white, green, gray, black, orange, blue and yellow. I have the 44110 model need help connecting the wires


Open unit and see what wires are running what never trust the colors.white heat'yellow cool'red 24v,green fan,blue prob your com, ... Air Conditioners

I need help with my central heat and air unit, it has a heat pump. the model number is GQ3RA-036K. I am changing the theromstat out and the wires are connected to it. there are eight wire colors that are orange,light blue,black, red, yellow,brown,green, white. on the new thermostat are letters that are r,w,y,g,l,b,o,e,aux. Which ones go where?


Normal\015\012 0\015\012 \015\012 \015\012 \015\012 \015\012 \015\012 \015\012 MicrosoftInternetExplorer4\015\012 \015\012\015\012\015\012\015\012\015\012\015\012 /* Style Definitions */\015\012 table.MsoNormalTable\015\012\011{mso-style- ... Air Conditioners

I am replacing a White Rogers 1F58-77 with a Honeywell RTH2300. When I removed the old stat the wire colors are white, red, orange, green, yellow, and blue. G- green wire Y- Yellow wire R- Red wire W- White wire O-Orange wire X1- Blue wire I hooked up all the wires except the blue. Instructions with the Honeywell unit said not to hook up the blue wire if there is an orange wire to hook up which I did. The problem, when I light off the A/C (heat pump) the compressor comes on but the


Yes you did correct. Tape of f blue wire. On your thermostat you should have el/gas turn top el and fan should work Russ ... Air Conditioners

I need the wiring diagram to wire a thermostat to the outside unit. Which wire goes where ? My Thermostat has four wires, green, red, white, and yellow. My Outside unit has three wires that are not connected ... a red wirte to a transformer, a yellow wire to what appears to be a relay, and a blue wire to the relay switch. Thanks.


The thermostat wires are this, Red is 24 volts hot, Yellow is cooling, Green is fan,indoor, and white is heat.The outdoor unit wires up to the indoor units terminal board, not the thermostat.The red will go to the R or red 24 volt wire at the furnace ... Air Conditioners

I have a Trane XE1000 heat pump and a RiteTemp 6036 Thermostat. I have red,orange, black, white, yellow, green, blue & brown wires & need to know what to connect where?


... Air Conditioners

WIREING MAKE FOR LUX ATX1500E THERMOSTAT 6WIRES COLORS GREEN RED BLUE ORANGE YELLOW WHITE.?


... Air Conditioners

Replacing the thermostat, took the old one off without marking the wires. Hooked it up by color and we get the furnace when we put it on cool. wires are green, red, yellow & blue (ground wire)on the wall. The new thermostat wires are red, yellow & green. Can you tell me which wires go where correctly?


The normal wiring for stats is white=w=heat,red=r=24volts,green=g=fan,blue=c=common,yellow=y=cooling.\015\012see what ties into your furnace board and match the terminals. ... Honeywell Air Conditioners

Thermostat with 4 wires, red, green, white and blue; no yellow wire to connect to new thermostat


... Air Conditioners

Have a 4 wire input into my thermostat but the thermostat is a 5 wire unit for heat/ac and the thermostat is an intertherm. Will any thermostat for heat/ac work and is the wiring different. Wires I have are Red, White, Green, and Yellow. The thermostat has O, B, W, Y, G, RC, and RH.


Red wire goes to Rc with a jumper wire to Rh\015\012White wire goes to W\015\012Green wire goes to G\015\012Yellow wire goes to Y ... Air Conditioners

"i'm replacing my Rheem RBGC 08KA FAU blower motor. My dayton 3lu83j 4 speed motor has white, black, red, yellow,orange, brown, and brown with stripe wires. My old westinghouse motor has only one brown wire, a blue and yellow (both taped capped and not used). do i leave the orange, yellow and brown with stripe unused". Or do i also connect the brown with white stribe to the shared terminal on the condenser.


There should be a wiring diagram on the side of the new motor.The brown and the brown w/ white go to the new capacitor you should have bought with the motor.The black and white go to your L1 & L2 power source. The remaining wires must ... Dayton Air Conditioners

Need to change a broken blower motor in RUUD central air unit. Old central air blower motor (GE electric) was connected with brown and orange wire to 15 MHD capacitor. Another orange wire from central air unit connected to orange motor wire on capacitor. Black wire from motor (Hi Speed) connected to central air unit. Blue and red wires not connected. New motor is an AO Smith FD6000A. Has Black, brown/white, brown, blue,yellow,red, white and black wires. Need to connect to a 5 MHD capacitor. M


On the motor should be a diagram detailing the wires. brown white goes to either side of the capacitor and brown wire to other side of capacitor. hi speed goes to normally open contact on the indoor fan relay and the wire designated common on the mot ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific