Having problems with your Air Conditioners ?

I have a unit that it is blowing out cold air when have it on heat. I have had issues in the past where the heat stop working. I had the part fixed and now i have no heat again. Where i live it is 11 degrees and it not planning to get warmer no time soon. I need some advise asap because i had a tech come out to look at it and they are stating that the gas valve is receiving the correct amount of voltage but it is not opening and suspecting a cracked heat exchanger which all this sounds famil


Answers :

Check power goes to heating coil by a volt metre. I think, it's better to calla repairman to repair/replace the heating sensor or heating element.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a unit that it is blowing out cold air when have it on heat. I have had issues in the past where the heat stop working. I had the part fixed and now i have no heat again. Where i live it is 11 degrees and it not planning to get warmer no time soon. I need some advise asap because i had a tech come out to look at it and they are stating that the gas valve is receiving the correct amount of voltage but it is not opening and suspecting a cracked heat exchanger which all this sounds famil


Check power goes to heating coil by a volt metre. I think, it's better to calla repairman to repair/replace the heating sensor or heating element. ... Air Conditioners

My central heater is not blowing hot air, I am having to turn the thermostat on and off. I have the thermostat to 70, and the heater will blow hot air and then it will just circulate the air in the house, therefore bringing the temperature down. I looked at the unit and noticed that when the thermocople (heating element) goes red, the gas valve makes clicking and the flames come and then go out very fast. I noticed lots of clicking in coming from the gas valve. help please


Hi!!! relax your flame sensor is bad change and you will be fine..If it turns off and on change your flame sensor ... Air Conditioners

Robert Shaw 2000 wiper gas valve quit working on a ruud, 50 ga. heater being used for floor heat. The spark looks weak. The pilot looks weak as well. All the pins are clean looking and wires appear to be attacked well. The unit was purchased in 2003, run for a couple of months before we figured out the application wouldn't work. We moved it to another location were it has worked fine for two seasons. Pilot and burner tubes are clear. Oriface in pilot tude is tough to blow through, but it is tiny


... Air Conditioners

I have a 15 ton carrier gas pack at work with inducer motor and spark igniter with hall senser ..showed error 6 flashes on igc board which the drawing said was inducer motor or hall senser problem..replaced both..they were old and rusty..error still there..inducer runs for 1 to 2 minutes..times out starts over again..no ignition..cannot here gas valve solonoid/coil click..checked igniter and flame senser cleaned..but they looked great ..no cracks anywhere..replaced heat exchanger 2 years ago..pr


... Carrier Air Conditioners

I have an amana dual fuel heat pump with LP gas furnace. the furnace will not light. the ignitor heats up, acts like it's not getting LP to the burner and i don't get 24 volts to the pressure switch just above the gas valve, or to the gas valve itself. i cut the power to the unit, removed pintle to the gas valve to ck for gas to the valve and it's o.k.,. what do i need to check next, i don't know how to get codes out of self diagnostic system and don't know if these codes would effect the furnac


... Amana Air Conditioners

Older Sunbeam Heat Force 85,000 Btu, LP salamander heater with a spark igniter, small sealed circuit board, asco red hat gas valve and temperature switch. The temp switch is an Elmwood L295 1/2" diam. surface mounted ceramic, 2-terminal sensor. The Asco valve is a Red Hat normally closed gas 110v, 10.1 watt valve. On/Off control is a toggle switch. The problem: I turn the unit on....fan starts, gas valve opens, spark igniter light flame....all good for 15-20 seconds. Then the gas valve shut


Hi,The problem is that whatever is sensing the flame is not telling the control that the flame is on...Not sure what you have on that unit, but I suspect that it is a photocell that sees the light and then tells the board that there is fl ... Air Conditioners

Turn Thermostat to call for heat (here click)from the t-stat calling. I do not here the multiple click (ignitor)and then the flow of gas. I have a Honeywell VR8204M electronic gas valve. I have votage coming from the control board "PV" to my electronic valve. My question is do I have to change the entire electronic valve or should check some other things first.


That particular intermittent pilot gas valve uses one of three ignition control modules; S86F, S8600F, and S8610. Check the pilot assembly and look at the flame, could be a weak flame, dirty or clogged, if its not lit or weak, you&rsquo ... Honeywell Air Conditioners

Lost power, gas from the gas valve was still flowing into the heat exchanger even tho the piiolet was not lit..... should I replace the thermo coupling or the gas valve or both


Sounds like the valve stuck open. I'd do both just cause you are there. The thermocouple is not the much of an additional expense. No gas should ever flow with the power off. ... Air Conditioners

I have a 1985 Bryant central air Furnace model 395BAW048095 with a White Rogers 36E gas valve. The flue is metal and there is a fan within the furnace to create a vacume at the base of the flue pipe conection that turns on when a call for heat comes from the thermostat at startup to ignition. The spark fires but no gas is released by the valve for the pilot to lite. Added information: The blower fan is set to continually run, I replaced the pressure switch (306621) and the limit switch (HH12ZB18


... Air Conditioners

Heater: Rheem Classic 90 Model RGRJ In service since 7/02 Problem: Thermostat calls for heat Steady Green Light Inducer motor starts and runs lighter comes on and glows no gas, no flame Voltage across gas valve is zero no yellow light lighter goes out inducer motor quits blower is off no heat Troubleshooting activities: Resetting (power off then on) will bring on the flame 99% of the time checked for exhaust clogs, none found no evidence of water at inducer fan housing barb have


Failed control board. Replace circuit board. ... Air Conditioners

Hi , I have a Electronic pilot lighting system on my RUUD package unit. The pilot light flame keeps blowing out or is not working properly. I removed the panel to look and see what was wrong. I could not see any faults. The sparker worked just fine, the gas line tubing was fine no blockages( took it off to inspect it) every thing looked good. Worked fine for the last couple of weeks and now it will not ignite the pilot light to light the rest of the propane gas to heat the house. I tested the fl


Sounds like you have checked most things. A pilot will go out if it is dirty, if the gas valve is not holding or if the senser is dirty or bad. Remove the pilot and clean out the small orifice inside. Check all electrical connections, clean the senso ... Ruud UBHC Air Conditioner

Our whirlpool water heater is not heating. My husband replaced the thermocoupler and it still doesn't work. We have had it for 8-9 months. Whirlpool is sending a new gas valve. We are reading that this will continue to happen even with the new parts. Is there a universal gas valve that we could replace it with that will work or should we consider just purchasing a different hot water heater? The model number is BFG1F4034T3NOV.


... Whirlpool Air Conditioners

Dear Sirs Have purchased a air conditioning unit model 11-lg-251. The system is loosing its gas charge. it looks the system has an internal, leak do you know of any problems with the gas or liquid charge valves. Shuld I replace the valves, or do you have other solutions. Best regards Ori Afek [email protected]


Hello sir/mam \015\012 before replacing any part please check from where the gas is leaking if the leak is in the line soldering is requirede and if the leak is in the valve then replace the valve so please call the tech for ... Air Conditioners

I have a Burnham series 2 gas boiler with honeywell controls. The taco zone valve control calls for heat or hot water, the boiler attemps to fire but goes to retry mode. This continues until I recycle power and it fires. My plumber replaced the gas valve, no luck.


Hello. The culprit is most likely the spark electrode lead. Once the pilot lights it rectifies the current telling the pcb [printed circuit board] the pilot is on it is ok to light the main burner. Begin by replacing the electrode lead. If it is ... Air Conditioners

I smell an odor possibly electrical but I was unsure and had the gas company come and check. The gas company serviceman states the gas connections are good, nos gas smell in any areas of the house. The unit is putting out heat at the correct temperature but the smell of a burning odor worries me. What should I check to verify an electrical problem?


Any burnt wire inside the room smell easily sucked by a/c and spread over the room. And hence, please check any electrical appliances like iron box, electrical oven, like this.which may be faulty.If your unit has heating element (heating strip ... Ruud UBHC Air Conditioner

My 1985 Kenmore furnace is not starting. It has a Honeywell DSI. There is a nice spark going on, but it seems no gas is coming in. (The water heater is connected to the same gas line, and it fires-up allright) Looks like the honeywell valve does not allow the gas to pass thru. Any hints?


You need tools. You need to check if there is any open sensors not allowing electrical current to travel back to the gas valve and open up like normal. Turn the furnace on c ... Air Conditioners

The gas valve on my Honeywell Glow Worm Space Saver Mark II boiler has failed. The part number on the valve is V8600A 1024 2. It is a 24v valve. I have seen several on the web that look similar but have slightly different numbers. How critical is to buy a replacement with an identical part number? Which alternatives are compatible? Andrew Blundy


Hello my name is Heath it will be my pleasure to assist you. Use a 3606c this is a universal type that will work for you. ... Honeywell Air Conditioners

Hi im a 3rd yr appentice refrigeration mechanic ,,i need the following for an assingment ,flow charts on reverse valve stuck between heat and cool ,,tx valve bulb has lost its gas ,and worn compressor head valve ,can u give me these flow charts please


Hi I have reefer unit on my trailer and need to how to change the belt for compressor? ... Carrier Air Conditioners

Brivis Wombat 92 heating unit - I am having trouble getting the pilot light to stay lit. The gas is on, the igniter is sparking and the pilot light ignites but when I gently release the red gas valve after 60 seconds as prescribed in instructions the pilot light flame extinguishes itself. Have tried venting the gas line to get rid of oxygen and this isn't helping. Any ideas?


Hear of a PRIMUS pricker?This is a very stiff but fine wire that was used to clear the jet on an old primus stove. The gas jet head at the pilot has a fine hole to allow gas to flow. When you hold it open with the button it allows for the ... Air Conditioners

A 2 month old Goodman GMH95 natural gas furnace has been working properly until tonight. Now it starts up properly, but after 30 seconds (and right when the cirulator fan kicks on) it shuts the gas valve stopping the flame. LED light flashes 8 times, which is not an option on the trouble shooting guide. Unit will retry every few minutes and cycles this way over and over. It appears the control module is not receiving the gas flame detection signal. What do we need to do?


Goodman's control boards are very sensitive as well as the connections to the gas valves. Check the wires and make sure they are snug and tight. With it being only 2 months old, I doubt the board is bad or the flame sensor(unless it is a used syste ... Air Conditioners

I have a GMP100 gas furnace. I need the diagnostics table that provides the meaning of the status light states. I get flame for 20 seconds and then the gas is shut off and LED on control board blinks 3 times. The flame sensor looks clean. I wired the flame sensor lead to ground as a quick test but then the gas goes out in 6-7 seconds. Any thoughts?


Hi!!! you just answer your question.change your flame sensor cleaning it wont work..\015\012\015\012\015\012 ... Air Conditioners

Blower turns on when stat calls for heat but manifold is not being ignited (do not hear gas valve even trying to release gas). No spark either. Could it be insufficent gas pressure?


Here is the ignition sequence for a spark ignited furnace. This will help you understand what is happening/not happening.\015\012\015\012Thermostat calls for heat.\015\012\015\012draft inducer motor (DIM) starts drawing draft ... Weather King 12AJA4801AH Air Conditioner

Gmpn80 4 lp gas, strong smell of gas outside at vent discharge. 2 new heat xchangers, gas valve, burners, furnace works great except for above prob


The manifold pressures must be 11.5 in or mor up to 13 some places, see that its not beeran with nat gas orifices, if it has it must be pulled and clen heat exchangers ... Air Conditioners

I have a Rudd furnace model UGRA-04EMAES in heating cycle inducer makes pressure switch ignitor lites up no gas pressure i rplaced gas valve and board still no gas. Wat next?


Well first you want to verify that there is gas pressure coming from the connector. Turn off the valve and disconnect the connector. Then turn on the valve for 1 second and back off. You should get plenty of gas flow. Be careful doing this!. Then ins ... Air Conditioners

I'm working on a Payne gas pack furnace heater and a/c unit. I replaced the tstat cause the a/c worked but not the heat,also replaced the spark ignition module with gas valve,the transformer, and the contacter now nothing comes on.


Pull the fuses and check voltage line to line with the fuses out you should have 208 to 240 volts if you have 50 or so volts try line to ground if you have 120 on one leg it will back feed with the fuses in,because of the windings involved. in any ca ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific