Having problems with your Air Conditioners ?

I am having problems with my condensing unit, fedders mod# ch48acd1vf. The unit will come on for about a minute and shut off and does not come back on. I have 24 volts at the red and white wires and the 2 L.E.D.'s alternate blinking. The unit has only been installed for about 4 months. it is a heat pump


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I am having problems with my condensing unit, fedders mod# ch48acd1vf. The unit will come on for about a minute and shut off and does not come back on. I have 24 volts at the red and white wires and the 2 L.E.D.'s alternate blinking. The unit has only been installed for about 4 months. it is a heat pump


... Air Conditioners

I have a Trane xe 1000 and the dog ate through the wires outside. There are now a blue and yellow wire coming out of the unit and red and white wires coming from the house. Without them connected the outside unit does not come on even though the blower in the house is blowing air. Which wires get reconnected?


... Air Conditioners

Sanyo Condensing unit. blower fan doesnt come on unless unit runs,but unit only runs for about one minute and shuts off. led #6on cond. unit blinks and led on evap. coil #26 also blinks unit needs to be turned offon for it to restart.


First, the condensor fan is only supposed to run when the unit is on. As for the one minute run, then needing reset...this sounds like a "safety out". The air conditioner knows something is wrong and tries to protect itself. Being low on Freon wou ... Sanyo Air Conditioners

Suburban sf30 rv unit.. I had a new board and limit switch installed. The service tech said it was working. I marked the wires when I removed the unit. I re installed the unit conecting the wires the same as when I removed the unit. I have 2 blue wires, 1yellow and 1 red coming from the furnace. There are 3 thermostat wires 1 grn, 1 wht and 1 red---The power source are 2 solid white wires and 2 blk and wht striped wires, there is power to the unit. I am at a loss as to why it will not work. T


... Dometic Rooftop RV Air Conditioner

I have a RUUD AC Model UPFA 060JAS, Serial # 3687 F4787 3195. My dog ripped the wires apart on the outdoor unit. Wire coming out of the house (6) are colored red, blue, white, green brown, and yellow. Wires (4) out of the unit are colored red,green blue and white and there are 4 wire nuts. How should I match them up? Thanks. Paul


Paul, you will need to look at the indoor unit and determine which wires from outside are connected inside. let me know. more then likley they color coded it but better to be safe. also does the fan inside still run if you switch thermostat to fan ON ... Air Conditioners

MSZGE12NA, OUTSIDE UNIT LED BLINKS SIX TIMES , INSIDE UNIT BLINKS CONTINUOUSLY. OUTSIDE UNIT WILL NOT RUN, INSIDE UNIT DOES. NO HEAT, COOL. CONTROL WIRE BARE "DRAIN" LINE CARRIES A LOAD THAT ARCED AGAINST OUTSIDE CABINET. THIS WIRE IS NOT ATTACHED AT EITHER END YET IS UNDER A LOAD. WHY IS A MYSTERY.


... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

I am replacing a White Rogers 1F58-77 with a Honeywell RTH2300. When I removed the old stat the wire colors are white, red, orange, green, yellow, and blue. G- green wire Y- Yellow wire R- Red wire W- White wire O-Orange wire X1- Blue wire I hooked up all the wires except the blue. Instructions with the Honeywell unit said not to hook up the blue wire if there is an orange wire to hook up which I did. The problem, when I light off the A/C (heat pump) the compressor comes on but the


Yes you did correct. Tape of f blue wire. On your thermostat you should have el/gas turn top el and fan should work Russ ... Air Conditioners

Its a trane unit model# TUE060A936K3 in cooling mode condensor comes on the indoor fan does not in heating mode every thing comes on but the blower fan does not there is not a led light blinking code lable on the unit i it looks like its giving 4 blinks pause and repeat 4 blinks etc. what does this mean


Hi,\012Either the vent is blocked or the pressure switch that tells it that the purge blower is running is not working right...for some reason that switch is not making contact and so it will not let it light..\012\012heatman101 ... Air Conditioners

EMERSON FAN MOTOR WHICH HAS A BLK WIRE PURPLE WIRE AND A BROWN WIRE WENT DEAD. SO I BOUGHT A NEW FAN EMERSON CAME WITH 4 WIRES BLK ,WHITH, BR AND BRW AND BRW WITH WHITE STRIPE. I WIRED IT BLK TO THE CONTACTOR WHITE TO THE COMM THE YELLOW FROM COMPRESSOR TO THE HERM BRW TO THE FAN BRW WITH WHITE STRIPE TO THE COMM THERE IS A RED WIRE GOING FROM THE COM TO THE CONTACTOR WHEN I TURN THE AC UNIT THE COMPRESSOR COMES ON PUT FAN DOES NOT ?????


The two brown wires go to the fans capacitor. The capacitor should always be changed with the fan motor.\015\012\015\012It sounds like your unit has a dual capacitor. One side for the fan and the other for the compressor. All you will be ... Dometic Rooftop RV Air Conditioner

I HAVE A CARRIER 40FS160300 UNIT WITH A WHITE RODGER DIVISIONS 24A55-124 FAN/HEAT SEQUENCER. I WAS GIVEN A BEACON Q106 (REPLACES WHITE RODGERS 24A34-6) IT IS A FAN/HEAT SEQUENCER WITH A ON &OFF TIME: 1-110 SEC. WITH M1-M2 &M3-M4 ALWAYS FIRST ON AND LAST OFF, WITH A M5-M6 & M7-M8 RANDOM ON AND OFF. I AM LOOKING FOR SOME KIND OF WIRING SCHEMATICS AT WILL TELL ME HOW TO WIRE THIS BEACON Q106 TO MY CARRIER UNIT. I AM ON S.S.DISABILITY AND CANNOT AFFORD TO HAVE A REPAIRMAN TOO COME OUT TO MY HOME; S


... Carrier Air Conditioners

Room A/C won't turn on. LED on unit displays EE. I'm told that an easy way to resolve the problem causing this, a faulty time delay board, is to just by-pass the time delay board. I've opened up the unit, and have access to the board. I've plugged in the unit, but have left nothing on, so as to be able to identify where each of of the 4 wires now connected to the board is supposed to be reconnected after I disconnect the 4 wires and pull the board out. The 4 wires are red, white, green, and d


I am sorry I haven't got back to you sooner, I have been busy at work. I have your info now and will find out what you need to do. Give me a little more time. Thank you, Shastalaker7 ... Air Conditioners

My dog chewed up wiring on outside unit and i dont know where they hook up it is a 4 wire set up with red white blue and green large ac unit dog chewed thru little brown wire leading to house and now ac wont come on


That wire is to your thermostat which of course turns the A/C on/off. One thing you can do is to splice the wire back together w/ small wire nuts (available at hardware store or wal-mart, and just hook it up color to color and then tape w/ electrical ... Air Conditioners

My Everystar MPM1-10CR-BB6 model air conditioner will not come on. I had removed the cover in order to do a thorough cleaning of the cooling coils (vacuumed off all months of collected dust & dirt). Wne I put the cover back on, the unit would not power on. I removed the cover again and found that I had one of the screws had severed a wire to the control panel (the purple wire that leads to DM3). I spliced the wire and checked for continuity with an ohm meter but... the unit still will not po


I'll pass on the link to the users manual. Hopefully your questions should be present in that manual:http://www.2instructions.com/search.php?creference=D7bffqa2w3....................sodeep ... Danby DPAC8020 Air Conditioner

My Frigidaire FSA 12 PA5C : - indoor unit shows a blinking ELECT LED + TIMER LED always ON + OPERATE LED ON - no fan working(no air coming out off indoor unit) - outdoor fan not working Please help. Any RESET button somewhere ?


... Frigidaire FAS184 Air Conditioner

How to change 3 wire motor with 4 wire motor for outside ac unit fan motor?....old motor had blk wire going to a circuit board, also pur wire going to c terminal on cap, also brw wire going to f terminal on cap...... new motor , on the name plate , shows blk and wht wire going to line. also brw and brw/white stripe wires going to cap.... does the blk go to the same place as the old blk and the white does it go to the other line wire coming off the contactor? also which terminals do i attach t


You need this wire onto the "F"terminal- fan terminal as this is a 230 volt condenser fan motor all your doing is parrelling the cap ... Air Conditioners

My AC unit has three wires, green, white red. Coming off the house and off the unit. How do I wire them!!


Hi, if you are talking about the wires,high voltage wires coming from the breaker box, and the same coming from the outdoor unit which are also high voltage wires, you have to set a disconnect box and mount it with in 3 to 5 feet from the outdoor uni ... Goodman CLQ36AR49 Air Conditioner

Shut unit down for cleaning, outside unit will not start now, I have line voltage at the contactor but the contactor will not engage.one wire from the thermostat runs to a little black box next to the contactor (white) the red one runs to a device down by the dryer on one side and back to the black box on the other side. Both of these wires come out of the box and attach to either side of the contactor.Could this piece be the problem or is it the black box.If I manually engage the contactor the


You are talking about the low voltage transformer ... Ruud Handle Air Conditioner

I have a Ruud heat pump upql-jaz 2.0 ton brand new within 3 months. I believe it is wired incorrectly, the auxillary heat will not come one and I cannot find a wiring diagram to show to the electrician. complete wiring instruction for the inside unit would be ideal. THANK YOU in advance for your time and effort of your reply!!!


... Ruud Handler Air Conditioner

My dog chewed up the t-stat wiring on my outside a/c unit (compressor?). I purchased some t-stat wire at Home Depot and replaced the wiring. At the outside unit, I connected the new white wire with the brown from the unit, and the new red wire with the yellow from the unit. This part was still connected from the previous install, so I copied from how it was wired before. For the wiring to the house, this was disconnected completely by the dog, so I connected the new white wire to the white w


Hello,Yes there is a 3 amp blade fuse(same as in a car) in the blower unit,take off the door and it is plugged in to the(curcuit) board.Pull it out and slip a new one in.That will restore the control voltage.Your repair sounds correct.Some times ther ... Air Conditioners

Wiring diagram i've got a GE electric fan motor. says 208-230 volt, single phase. numbers painted on motor are GBDQ 5861A. five wires coming out of motor, black, white, red, orange and blue. what are these supposed to be hooked to? squirrel cage fan motor. appears to have been part of a colling unit. thanks, glenn my email is [email protected]


The white wire is nuetral, if you are trying to make a shop fan or something like that then you hook it to the white wire which goes to the wide spade on the outlet. The black one which is the hot and goes to the smaller blade (looking at an outlet ... Goodman CLQ36AR49 Air Conditioner

I'm replacing a trane weathertron with a lux tx9000ts. I have seven wires coming out of the wall. G=green, o=orange, x2=brown, y=yellow, r=red, w=white, and b=blue. Where does the x2(brown) go to? Also the unit outside will not come on if the fan switch is in the auto position on heat, any solutions?


... Air Conditioners

My 6 year old Heat pump RHE 60 on days when temp. gets up to 85F the Compressor struggles to come on some times up to 10-15 minutes.A hard start kit was installed when unit was 5 months old for similar problem but later they (service people) found it was caused by a burnt wire. I dont know if they left the hard-start kit on unit or removed it. I cant get installing dealer to find me a fix for this problem .


Hi,One of the methods to curb if the compressor is not working is " Installing Start Kit".There might be many reasons.Let me write main reasons :-\015\012\015\012\015\012Compressor will not start some or m ... Air Conditioners

Installed rooftop unit, themostat wires coming out of unit does not have red wire to hook to thermostat ?


... Air Conditioners

Hi, I'm currently having problem with my MiTsubishi Starmex. When switch on there would be LeD indicator that will light up under the operation indicator, however after a while it will changes to only one & it will keep on blinking & we can't feel the air coming out. May I know what does tis indicates? Do we need to do servicing on the unit? Thks, sharifah


... Mitsubishi Air Conditioners

Thermostat Connection ________________________________________ I just purchased a rheem rqpm series 4ton packaged heat pump and a honeywell pro th4210d thermostat. I had 15 kwatt heat strips installed in the heatpump as I live in norther florida where the temp might drop to 20 degrees occasionally. I am unclear as to how to connect the thermostat. The wires coming from the heatpump unit are red, yellow, blue, green, white, and brown. The thermostat terminals are as such: E Aux Y G O L R B


Jumper E to Aux, OR B + O, G--green, R----red(power), & C--------common. w2---------white, Y.....Yellow and finally the Brown-----------PRCrossed my fingers too & go for it. worst is a warning hum &/or sparking one one terminal whic ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific