I have a 4-ton Frigidfaire air conditioning unit on my 2400 square foot home, but I am not receiving the cooling I should receive. My split system model is #: FT4BF-048K. My air handlers Model is #:B4VM-X48K-C. I suspect my problem may be duct size. What should be the sizes of supply and return ducts on this unit? Phone 941-776-9270.


Answers :

Hi, the ducts are 18" round at the beginning and branch out to smaller sizes for other rooms. 10" for living areas, 8" for bedroom, down to 6" for bathrooms if they have them.If this unit was just installed, I would recommend getting the contractor out and do a balance of the duct work as they should have installed hand dampers to balance out the system, so you will have equal air distribution throughout. I would have went with a 5 ton unit for 2400 SQ.' home, but that's what the contractor recommended. If its only been there a short time, get them back out there as you may have other problems. If its not a new system, it may need to be serviced, outdoor coil washed, you may have a small freon leak, anything could be wrong. This is what I recommend, call out the contractor.
Sincerely,
Shastalaker7
A/C, Heating, & Refrigeration Contractor

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a 4-ton Frigidfaire air conditioning unit on my 2400 square foot home, but I am not receiving the cooling I should receive. My split system model is #: FT4BF-048K. My air handlers Model is #:B4VM-X48K-C. I suspect my problem may be duct size. What should be the sizes of supply and return ducts on this unit? Phone 941-776-9270.


Hi, the ducts are 18" round at the beginning and branch out to smaller sizes for other rooms. 10" for living areas, 8" for bedroom, down to 6" for bathrooms if they have them.If this unit was just installed, I would recommend getting the contractor o ... Frigidaire Air Conditioners

Dear Sir/Madam, I have a 12 years old Goodman split AC. Recently the blower in the air handler was not starting sometimes. I changed the capacitor, but the problem is still there. I guess that the fan relay switch may be bad. Where can I find the fan relay switch for Goodman center AC? The model no for air handler is AW24-05c, the serial no is 9904464660. You help will be much appreciated. Thanks, Sherman


... Goodman Air Conditioners

We have a Vulcan ducted heating unit model HX100, recently we have experienced problems with the unit where is it not heating the house, the unit goes on but blowing cold air. We have had a couple of technicians to repair it and still not working. One fixed the switch pressure & the other the flame sensor connection. We have been advised that we may need a new unit or repair the board. As we have an illness in the family, we would like to know whether we need to purchase a new unit as p


\015\012We had the same problem with our carrier heater 4 year or so ago. We had a technician and electrician try to resolve the problem. What the tech suggest was to replace the main component ... Air Conditioners

Condensing unit continues to run after air handler is stopped. Problem is intermittent. Thermostat replaced. Suspect air handler relay. which one?


When this happens, most often you'll have a stuck contactor coil on the condenser. If you buy it , it should cost $20---to 15.00 and you can add if you turn off the power (240volts) and the furnace power! ... Goodman Air Conditioners

I have a Jantrol heat pump & A/C. It is approximately 10 years old. For the last 3 summers the compressor unit will freeze when the air handler fans fails to come on. It worked fine for 2 weeks this year before it happened. I've be able to thaw it out and restart the unit and it works from days to weeks before this occurs again. The last time it happen, I had a problem getting the air handler fan to come back on, but it did eventually. I've been thinking it may be the sequencer, but now I'm wond


Hi,\015\012\015\012If you can safely check the supply to the motor when it should be on, then this is the best method to check it.\015\012\015\012Check the fan turns very freely - oil the bearings if it doesn't.\015\012 ... Goodman Air Conditioners

Ok..here's one. I have entire air duct system that is condensating ON THE OUTSIDE, UNDERNEATH. I noticed the problem before and after cleaning the coil in a closet air handler. Air runs fine, cools normal. But this condensation baffles me. It is even on the plenum! The pipes seem wrapped fine, and the plenum is good to go as well.


Not moving enough air or duct work is in a unconditioned space and needs to be insulate. what are your freon pressures, suction and liquid line temps, and indoor wetbulb ... Air Conditioners

Amana AC model MBR2000, installed mid May 2009. When outside temp gets above a certain level the AC does not cool. fan keeps running and it keeps trying but not work. When outside air gets cooler then starts to work again. Tech here twice. 1st time when AC was working - could not find problem, 2nd time when problem was occurring. 2nd time found burnt wire and replaced. Same problem started again 2 days later. AC unit is large enough for our house, is 18 Seer 2 stage. Any suggestions as to proble


Hi it sounds to me like what actvates the 2nd stage of the compressor is not turning the compressor on when the ambeint temiture reaches the point that it calls for the 2nd stage to start it may be an out door thermostat or a ambient senser and I wou ... Air Conditioners

Keeps freezing We installed a brand new Goodman Condensing Unit, Model #GSX130481, Serial #1304691511 and installed a new coil, Model #96-8W4N-0p/96-8, Serial #M0425130485 (Mortex Brand)in the existing Air Handler. The unit keeps freezing up. Can you give any insight on what might be the problem?


Low air flow or low on refrigerant. ... Goodman Air Conditioners

KENMORE Room air conditioner-Model #58078183890 - This is a very good, but older unit. The problem that I am now experiencing is that, it is now beginning to make loud intermittent noises (such that of a car?s old or slipped belt).I looked at the Air handling and cycle parts diagram, and noticed that the motor is oil free I believe and there is no belts. Can you please assist me as to what parts I may need to purchase?


What kind of intermittent noise are you hearing from the air conditioner? Is it like a knocking noise? If it sound's like knocking, then it's either the fan or bearing that holds the fan. First, the first thing that you need to check is ... Air Conditioners

There is a switch on my 1 1/2 ton Ruud furnace/Air handler that is not working properly. The unit would not turn on, even though the thermostat was working. I took the panel off of the air handler and found that a switch had been duct taped into the on position on the unit. Apparently, the tape had shifted and the switch was no longer in proper position. when i moved the switch, two green indicator lights lit up. When i turned the unit back on, the A/C worked. Clearly, there is a problem w


Helllo, this switch is called a door interlock switch. ... Air Conditioners

Replacement My airconditioner has started to leak water into the room, and is becoming noisier. Does any one know what would be the cureent model replacement for it? Also, the manual says if it is leaking into the room to tilt it back, but it is wedged in tightly, and has also never done this before, so I suspect this may not be the problem. Again, any suggestions? I have the same problem with my CW-1006FU. Last time I called in a repair person, this time I'm about ready to try and replac


Remove the front panel, & look for the drain tube that runs from the drip pan under the cold coil. It is likely blocked & may be cleared with a piece of coathanger wire. Be gentle.\015\012or\015\012Hi, If this is a new unit I woul ... Panasonic CW-1006FU Air Conditioner

I have a Ruud Achiever High Efficiency heat pump manufactured in 02-2002 model # UAMB 024JAZ 60 Hertz that the coils in the air handler inside the house freeze and won't cool the house. Our environment is South Florida and is humid. We set it on 74 and it constantly ran yesterday and never cooled below 76 when we discovered this problem. How do we prevent/fix this from happening again? Thanks in advance for any help you can give us.


Indoor coil freeze-up is always caused by lack of airflow over the coil. Check your filters, check the coil to be sure it has not been blanketed by dust that bypassed ir went through the filter, check that all vents in the house are open.Indoor ... Ruud UAMB Air Conditioner

System pressure for puron read 280 and 135 for low side. System is not cooling at all. Suction line at air handler is not cold at all. System has had problems with leaks and customer has told me some techs have added refrigerant which I suspect has affected the mixture of the refrigerant. What should I do to bring thge system up to it normal capabilities. Also amps for compressor was 8 and is rated for 23 RLA


The system must be leak checked, refrigerant recovered, evacuated, a drier installed, and recharged to the correct subcooling, (I assume this is a carrier since you reference "puron")\015\012the low side pressure seems to be in line the high si ... Air Conditioners

HI My Vulcan C-X Gas furnace Model 901 has got the pilot light on, but there is only cold air coming through the ducts. What seems to be the problems? Look forward to your reply. Thanks. Kevin


... Vulcan Air Conditioners

I have a problem with my heater i have a grandaire air handler and i changed all the parts and contacter keeps opening and closing.the model number is gb3bm-024k-a-10b


IS IT GETTING 24V CONSTANTLY? ... Air Conditioners

Rheem Air Handler will not run. This is a 2006 Rheem model RHLA-HM3617JA Air Handler. I replaced both the condenser and air handler circuit boards. I replaced the motor in the air handler.. The condenser works fine, the board flashes normal. The air handler board shows 0 volts on the X13Com brown lead,..28 Volts on the center, X13G green/black lead, 1 volt on the Bottom, Blue, X13SPD terminal. The 24VAC Terminal shows 27 volts. The 3 amp fuse is good. The transformer appears normal. I replaced


We tried to bypass at the Tstat. Thanks for your time and interest. ... Air Conditioners

Rheem Air Handler will not run. This is a 2006 Rheem model RHLA-HM3617JA Air Handler. I replaced both the condenser and air handler circuit boards. I replaced the motor in the air handler.. The condenser works fine, the board flashes normal. The air handler board shows 0 volts on the X13Com brown lead,..28 Volts on the center, X13G green/black lead, 1 volt on the Bottom, Blue, X13SPD terminal. The 24VAC Terminal shows 27 volts. The 3 amp fuse is good. The transformer appears normal. I replaced


Have you hard wired your fan motor to verify that the motor and or the capacitor are good? If you do a continuity test of the motor leads(with electricity off of course) you can see if the motor has open or grounded windings. ... Ruud Handler Air Conditioner

Have a RV Dometic Duotherm 13.5K Brisk Air Conditioner, Model No: 57915.331C. Have a ducted air conditioner system. Using Dometic Quick Cool Ducted Return Air Package Model No: 3105935.039. What is the correct Control Unit to use with this system?


... Dometic Air Conditioners

Air handler Is a 3 1/2 ton air handler too big for a 2 1/2 ton air conditioner? air conditioner FT3BA 030KA air handler B3BV 042k BB Also duct work in garage has a gap bringing in air from garage.


Yes and that's dangerous as fumes and exhaust may enter the house ... Air Conditioners

Carrier Air Conditioner Infinity System - Air Handler Sweating & Duct Work Condensation


If its an infinity. check and make sure you have a proper charge and no air infiltration from attic. also check blower speed on your humidity control in the controller set up ... Air Conditioners

Trane air handler model #TWV036B140A Fan wont stop


Sounds like you have a bad fan relay, the fan should shut of within 30 to 120 seconds after t-stat is satsified. ... Air Conditioners

Trane Air Conditioner air handler drips water


Amp draw on evap motor should run 80% of FLA to ensur max. efficency. Make sure fan is turning in the right direction water will run down coil if air isnt blowing it off. Gravity always takes over.make sure fan blades are clean and turning in the rit ... DeLonghi Trane 5t Rooftop Air Conditioner Ycy060g1m0ad

I have a Trane Model TRW036C100A0 heat pump with an American Standard Model TWE036C14FBO air handler. The heat pump outside is 20 years old and on it's last legs. The air handler is only about sev


... Air Conditioners

Installed goodman air handler, system has hot water coil in duct for heat, how should i wier the 6006, or 4006 control to turn the fan on, on the air handler? if the limit switch turns the fan on for heat, isn't it going to send 24 volts back up the green wire to the t-stat? old air handler ( york) had a fan center relay.


\015\012\011\011\011\011\015\012\011\011\011\015\012\011\011\011\015\012\015\012\011\011\011\015\012\011\011\015\012\015\012\011\011\015\012\011\011\015\012You abso ... Goodman Air Conditioners

Compressor I have a air condition unit that blows out cold air for a little while and then the air in neither cold nor hot. I had someone come and check it out and they said the compressor was bad. Is that really the problem or could it be something else? The model I have is Intertherm T3RC-042K. I just don't want to have to spend that much money on fixing the compressor and that is not the problem. If it is the problem, is it something that can be done yourself or does a professional need to do


If the unit does blow out cold air for a few minuets then quits it could be a low pressure cut out that will turn off the compressor because the unit is low charged mening there is a leak in the sealed system i would get a second opinion and show th ... Intertherm P3RA-042K Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific