Having problems with your Air Conditioners ?

We have an Encon Corinthian 3 speed ceiling fan with triple light. The switch for the fan no longer changes the speed. Is it possible to get another switch and how much would it cost? We tried to get one locally but could not get it to work. We were told to contact the manufacturer. Thank you for your consideration. Carol


Answers :

Hi!!\015\012
\015\012IF YOU ARE TALKING ABOUT THE PULL DOWN CHAIN SWITCH, YOU CAN GET A REPLACEMENT AT ANY LIGHTING STORE, ACE HARDWARE, HOMEDEPOT, ETC. (CALL FIRST) FOR LESS THAN $5. I SUGGEST TO TAKE THE OLD SWITCH TO GET AN EXACT REPLACEMENT. I TAKE IT THAT YOU KNOW HOW TO GET IT OFF AND ON, USING A PIECE OF MASKING TAPE LABEL THE WIRES OR TAKE A PICTURE, TO AVOID MIXING UP THE WIRES LATER. \015\012
\015\012GOOD LUCK!!

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

We have an Encon Corinthian 3 speed ceiling fan with triple light. The switch for the fan no longer changes the speed. Is it possible to get another switch and how much would it cost? We tried to get one locally but could not get it to work. We were told to contact the manufacturer. Thank you for your consideration. Carol


Hi!!\015\012\015\012IF YOU ARE TALKING ABOUT THE PULL DOWN CHAIN SWITCH, YOU CAN GET A REPLACEMENT AT ANY LIGHTING STORE, ACE HARDWARE, HOMEDEPOT, ETC. (CALL FIRST) FOR LESS THAN $5. I SUGGEST TO TAKE THE OLD SWITCH TO GET AN EXACT REPLACEMEN ... Air Conditioners

I have dimmer switch controlled ceiling fan. What happens is the dimmer switch seems to works for a few weeks. Then it doesn't behave like a dimmer, but only as a switch - meaning that the fan gets on only at the maximum position of the dimmer. If dimmer is even slightly lowered from the maximum position, the fan gets off. This happened to a previous dimmer also and I have changed to a new one - but still same problem. What could be the cause?


It is better to switch over to the stepped switch type dimmer as the potentiometer( the control ) in these types wear off very easily.\012So when the carbon track loses contact the varation of the resistance to feed the SCR does not happen but ... Air Conditioners

I have a Duo-Therm Penguin model#610115405 that cools and the fan changes speed(slower) when the room gets cooled and the compressor kicks out, but the fan will not shut down.I have the same unit fwd in my RV that works fine. I tried switching the thermostat,ptcr relay and the capacitor that is below the ptcr. Any other suggestions ? Dont see anything that else that I can easily switch to check.Still not shutting down?


Hi,\015\012the relay that is suppling the power to the fan is welded shut and is not opening. This often happens with relays, the contacts get pitted and then they heat up and weld fast. The relays that run the fan faster and slower are still w ... Dometic Rooftop RV Air Conditioner

I don't know what model my fan is, but it's only 3 years old and suddenly two days ago the light and fan quit working. We replaced the light switch on the wall-nothing. Took apart whatwe could of the fan to look at the wiring-all intact. We then replaced the battery in the remote and it instantly worked fine again. After putting it all back together it stayed lit with the fan working for about two hours at which time I turned it off using the wall switch. I immediately tried turning it back on a


That may be, because you were using the Remote Control to operate it, but then turned off the wall switch instead of turning it off using the Remote Control.Turn the wall switch back On and try to get the Remote Control to take back over ... Hampton Bay Air Conditioners

Installed the Altura 56" fan (56ATR), worked fine at all speed until we put on the light. Everything worked fine for about 10 minutes, then the fan stopped working, but the light stayed on. Kept trying to get the fan to start at any speed but no luck. Seems as though something may have burned out after we installed the light.


Both the fan and light have a common connection .. usually all the white wires are connected at one wire nut .. check to see if the fan wire has pulled out of the wire nut ... remove the wire nut and re-tighten it .. pull on each wire to make sure ea ... Air Conditioners

This is a heating and cooling through the wall heat pump. It works normally when heating is selected - the heat pump runs and both speeds of the fan blow warm air. But nothing runs when cooling is selected. In other words the unit works normally when "High Heat" or "Low Heat" is selected but nothing runs when "High Cool", "Low Cool" or "Fan Only" is selected. The position of the Fan Cycle Switch has no effect - behavior of the unit is the same in both positions of the Fan Cycle Switch.


You have a bad board or bad switch. I would say board. You can have service tech check this out. There is only so far you can go without knowledge of Controls ad electricity. Russ ... Air Conditioners

Have a whole house fan which has a 2 speed motor. Stopped working. I know there is power to the fan. checked with a voltmeter. Have taken off the 2 speed switch and connected the two black wires together, did not work. connected the two black wires and a red wire together, did not work. Is there a way to test the motor?


Test Motor: Gain access into the motor area then smell the motor. If you detect a strong odor (the shellac that coats the copper coil windings when the motor is burning or burnt out) then the motor is bad and needs to be replaced.\015\012Second ... Air Conditioners

Fan Hello, my ac unit blower on the inside is working fine but, the outside fan isn't. i just bought a new relay switch due to that what it was a few years back. but, it's not working the outside fan. so, my question could it be another relay switch? or the compressor? Thanks


Hi wild 36.\015\012I think the problem may be a bad run capacitor. If the outside unit is humming with no action, that may be it.\015\012\015\012This could also cause the outside unit circuit breaker to trip.\015\012\015 ... Air Conditioners

Carrier 58STA error code 31. the inducer fan worked last night and after several attempts of turning on and off the furnace switch i was able to get it to entually fire up. Today the inducer fan won't even come on and i am getting an error 31. Is it the fan, pressure switch, blockage or circuit board?


... Carrier Air Conditioners

My Airworks ceiling fan with remote stopped working. With Room light switch in 'on' position, remote no longer turns light on or controls fan speeds. Changed 9-volt battery but did not make a difference. In the compartment where 9-volt battery sits there is a small switch that has 4 tiny switches. Are these for any particular function of the ceiling fan? If it was only the bulb that needs replacement why should not the remote control the fan operation? Can you help or make suggestions to try?


... Air Conditioners

Hi, I have an 1985 Chelsea attic fan. The motor is still working fine, and it is turning the main bolt on which the fan blades are hung. This main bolt turns very fast, at the speed of the motor. The fan blades start slowly, and they used to accelerate to full speed, but now they just stay at a slow speed. What could be the problem? Thanks, Joe


It is the fan clutch. Like in a truck with a full time fan, it has a clutch that accelerates the fan as it is needed. Your clutch on the fan has probably burned out. ... Air Conditioners

Our Furnace doesnt seem to be working correct. We an: Air Pro BGM075128 and is Natural Gas. It will turn on when we turn up the thermostat.. but we never get any heat through the vents. There is a switch on the side that is "on" and one that is "fan". If we turn on the "fan" only cold air gets blown through. It looks like this is for cool air. So, if we leave the fan off and the "on" swith on, we get the furnace firing up, but no heat ever comes through the vents. I tested out the thermo


Sounds like the blower motor is not working, if the furnace is actually lighting up and the burns are ignited. You should set your thermostat to auto, as if it is on fan then the fan runs all the time until you take it off of fan. I am a little confu ... Air Conditioners

I have two Harbor Breeze Triton (Item #233576) ceiling fans purchased approximately 3 years ago. Neither have pulls, so the only way I can change the fan speed or dim the light is with the remote (the light can be shut on or off with a light switch, and I can also turn the fan off completely, if I want). A few weeks ago, one of the remotes stopped working...replaced the battery, etc., and nothing worked. I took the remote from the lesser used fan, changed the dips, and use it for that fan


... Air Conditioners

I have a Hampton Bay 3 speed ceiling fan with a broken fan switch. When I removed the housing the switch was broken apart and I could not tell where the wires go in the new switch. The wires are black, orange, yellow and purple and the terminals on the switch are marked L, 1, 2, and 3. Which wire goes to which terminal?


Black is the groundOrange , Yellow and purple are SPEEDs 1,2,3 respectfullyconnect them and test it out,, you will see what speed it spins,, hange round the wires if necessary.. Basically if black connect to yellow u get spd 1, blk orange ... Hampton Bay Air Conditioners

My carrier A/C YHB243D this window unit was working find. But about one week ago only blows out cold air and sometimes only hot air but now it blows only regular air, and doesn't work nither the cool or heat air. what could be wrong with it?_a) could be- the thermostate that goest at it front with its condenser unit? b) could be the whole temperature switch ? or what else can be its problem, please help! and tell me where I can get the replacement part


... Carrier Air Conditioners

Replacement fan I'm trying tov locate a replacement upper fan for this portable ubit. I called my local rep who directed me to the Fedders main location. I called and the recording says to check online, I can get an exploded parts list and can order from there. I do not see any thing like that. I sent 2 different email messages and have gotten an acknowledgement email but no more than that. HOW hard could it be to get a replacement part? Anybody have any ideas on how to get a replacement motor f


Please check the of fan , no of blades and direction of flow & also if possible pic of fan . it can be easily avl in open mkt. \015\012ravi ... Fedders A6P09S2A Air Conditioner

AC, Fan-Auto, Fan-On... nothing works. the request from the Thermostat doesn't engage anything. Thermostat Dispay works. How do I know if it is getting the 24volts from the relay? I presume the display wouldn't work if the 24v from relay wasn't there. I have two separate systems in the house. So therefore, I pulled the thermostat off the base and tried it on the faulty system. No luck. Still same issue. Perhaps it's the Honeywell base itself? what electronics are in there that could fail? How ca


Open the air handler. Locate the low voltage transformer. One side is 220 volts input. The other is 24 volts output. Take your VOM and touch the test leads to the input to verify 220v in. Then touch the other 2 leads to verify 24v out.If you ha ... Honeywell Air Conditioners

Amana AC model MBR2000, installed mid May 2009. When outside temp gets above a certain level the AC does not cool. fan keeps running and it keeps trying but not work. When outside air gets cooler then starts to work again. Tech here twice. 1st time when AC was working - could not find problem, 2nd time when problem was occurring. 2nd time found burnt wire and replaced. Same problem started again 2 days later. AC unit is large enough for our house, is 18 Seer 2 stage. Any suggestions as to proble


Hi it sounds to me like what actvates the 2nd stage of the compressor is not turning the compressor on when the ambeint temiture reaches the point that it calls for the 2nd stage to start it may be an out door thermostat or a ambient senser and I wou ... Air Conditioners

I'm replacing an existing ceiling fan that is wired to a light switch and a 5 position (off/high/med/low/off) speed switch on the wall. The new fan is a Hampton Bay Glendale. The wiring instructions only show basic connections to the power supply. How do I identify which wires to connect to my switches to get full functionality?


Hi. The fan has its own built in Variable speed setup. In the case that the red wire belongs to the variable device, wire the Red to Blue(light), and Black to Black Whites to white. Green to Ground. bare wires to ground. Joe ... Hampton Bay Air Conditioners

GOODMAN CMA80905CXBA FURNACE. INDUCTION BLOWER NOT ENERGIZING. GETTING 3 "BLINKS" FROM DIAGNOSTIC LIGHT (LOW PRESSURE SWITCH OPEN). THE A/C WORKS & THE BLOWER FAN COMES ON WHEN THE STAT IS IN THE HEAT MODE WITH THE FAN SWITCH ON. WHILE THE FAN IS ON , THE DIAGNOSTIC LED STILL BLINKS A CODE OF 3. THIS IS NOT A CONDENSING FURNACE. I BYPASSED THE STAT (W & R)TWISTED TOGETHER---SAME RESULT---DIAG LED COMES ON STEADY, THEN FOUR CLICKS, AND BACK TO THE CODE OF 3 BLINKS. CIRCUIT BOARD???? OR 120VAC NOT


The pressure switch is closed before the draft motor closes it.the board is telling you that this is not right.pull the wire(either) off of the pressure switch to see if furnace tries to light.if it does,you should replace the pressure switch. ... Goodman Air Conditioners

When Unit is switched off . The outside part turns on = off as if working, I have just been up to check, found compressor is also runningas is fan motor. we just switched A/C back on to cool , all working OK. Could it be the Stat unit inside at fault.If so here are No.... Electra-teck 50-00402-C ..Stat3176955.065 ... 3107612.024 Duo-Therm, Domestic Thank you Terry Email . [email protected]


The easiest way to see if it is the thermostat is to write down what wire goes where and pull all the wires off. If it still does it, it's not the thermostat. If it stops, you'll need to get a new thermostat. Let me know what you find out. ... Dometic Rooftop RV Air Conditioner

Hi weve a Mistral MSS10 and it only blows on a low speed ? No gecko damge obvious cools but only on low fan, could the fan unit second speed be faulty and were can we get parts?


... Air Conditioners

I have 4 Airtech Ceiling Fans with the RL117 Receiver and Transmitter. Two of the RL117 Receivers do not want to switch the lights on and off anymore but I can still change the fan speeds and nobody can fix the receivers for me in South Africa because they all say that they can't get any components for the receivers. Who can fix it for me or where can I get new receivers from?


... Air Conditioners

HEATER/AC WILL NOT WORK UNLESS FAN IS ON ON, IF IT DOES WORK WITH FAN ON AUTO THEN COILS INSIDE GET HOT. HAVE CHANGED THERMASTAT WHAT ELSE COULD IT BE?


Your problem is the thermostat if you read the instructions it will tell how to do it , some thermostat have some switches you probably have the settings for gas applications you need to set for electric or heat pump depending of type of brand some h ... Intertherm Air Conditioners

1. Have 610015.405 AC Penguin model that has no low or medium speed and low voltage light comes on at these speeds only. Works fine on High. Suspect control board, is that right? Where do I get a control board. 2. Have another AC, same model, that comes on even with switch off. Is this switch or control board? What is going on? Parts? Thanks in advance for your help. Van


... Dometic Rooftop RV Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific