Regarding the installation of the f500 honeywell filter system. does the output of the filter system get ported into the return air prior to the air handeler? I had my unit installed today and i believe it was installed incorrectly. The input to the filter system comes from my return air box but the output is ported into the air box after the air handeler.


Answers :

Hi,\012
Here is a tip that tells you how to get a manual for most any Honeywell productonline...

Manual Honeywell How to Find Honeywell Manuals

heatman101\012
\012cc

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Regarding the installation of the f500 honeywell filter system. does the output of the filter system get ported into the return air prior to the air handeler? I had my unit installed today and i believe it was installed incorrectly. The input to the filter system comes from my return air box but the output is ported into the air box after the air handeler.


Hi,\012Here is a tip that tells you how to get a manual for most any Honeywell productonline...Manual Honeywell How to Find Honeywell Manuals ... Honeywell Air Conditioners

We installed a Honeywell RTH230B thermostat on a Trane XE60 Air Handeler this winter. When we put the system on heat it works fine. However, when we put the system on auto for cool the compressor fan comes on but not the air handeler fan. On the air handeler the terminal strip from left to right is R W Y G B/C. The red wire on the R terminal comes from the contactor on the compressor unit. The other wire from the compressor unit is connected to a gray wire that goes to the thermostat. The W


I ran into this before and had to call Honeywell for help in the wiring...it seems the wiring was not done to standard, and they were able to help me get it straight in about 10 minutes and at no charge. ... Air Conditioners

In Dec 07 I had a complete Carrier AC/Gas Heating System installed in my home to replace my original system when my house was built in 1983.We upgraded the new system to 3-TON AC as the old AC was 2 and half ton. Since the new system was installed in the winter time it was not until the hot weather started in May that a problem arose. The first conclusion of the problem was that the coil was aligne incorrect the second was that we needed more air return so an addition vent was added. No


Air conditioning requires 400 cfm (cubic feet per minute) per ton of cooling so your old 2.5 ton system would have required 1000 cfm and your new 3 ton requires 1200 cfm. This is not a big change, but if your ductwork is too small it could cause pro ... Carrier Air Conditioners

I bought a Honeywell air purifier HPA-051. Pre-filter was in a plastic bag at the bottom of the box. The instruction manual is not very clear about the installation of it. I don't know where it should go. Should I install it inside the rear grille? The pre-filter has a black side and kind of a grey side. Which side should be facing the true HEPA filter? Thanks a lot for your help! Andrea


... Air Conditioners

My daughter has a Bryant AC Model number 563AN048-A where the outside coils are freezing up. The repairman has been out twice and has cleaned the coils on the inside and outside units and has checked the coolant levels that he says are ok. Currently, if they remove the cold air return filter, air circulation is increased slightly and in doing so, the outside coil is not freezing. Can't run the system without a filter as the internal coil will clog. Any suggestions would be appreciated. Assoc


Hi, this is a 4 ton unit, Bryant are top of the line, I believe so as I have worked on them for so many years. They were Day & night, just a name change is all. Here is what sounds like your problem is, or is your problem. Did the tech check the ... Air Conditioners

My HVAC only has a 5 degree difference from the cold air return to the discharge and my air excahrger freezes over because the unit runs constantly. I have had the entire system cleaned and the filter is only a 6 merv to maximize the air flow. What next? Have the freon charge checked?


Odds are it's either a low freon issue or low airflow. ... Air Conditioners

Just installed 4 ton Goodman air and heat unit. Loud roaring noise from return duck in living room, louder than old unit, very loud, have to turn up TV to hear program. Unit colls great and not lound anywhere but the return Vent room. Is there any king of filter or muffler to be applied


... Goodman Air Conditioners

Purchased a dometic duotherm a/c for rv partially installed it, but conected all the correct wires and it will not turn on. All new unit with new thermostat and control box. the Thermostat requires 7.5v dc to function but the control box is not producing the voltage. None can be detected on the terminals of the thermostat. there are two wires for an solar/filter indicator that should have +12v and a -12v. neither have any voltage present. tried to return the whole system to the vendor bu


Check all grounds,all grounds,I stress this because the system may need ground elsewhere to operate.If the control box is what produces the 12 volts dc,and the 7.5 volts dc,and you have power to the box,then the box(converter)is bad.Is this unit 120v ... Dometic Rooftop RV Air Conditioner

How to evacuate system after installing air conditioner air handler?


... Air Conditioners

I have an amana heating/cooling system. it is 3 years old. it has 2 fans/compressors outside the house that seem to operate fine. with all the hot weather this year we have used the air conditioner more than we typically do. i hadn't thought to change the air filter sooner because of the increased use. the filter was so clogged it got partially sucked into the air handler. i shut the switch off on the system and removed the filter to get the size off the filter. i closed the system back up witho


What you have done is restricted the air flow the water is most likely where the indoor coil is froze and you may need to clean the coil as well just from your symptoms shut unit down open the door of coil this is most likely in the shape of an A re ... Amana Air Conditioners

Should I have a return air grill with a filter?


If the closet the inside unit is in is vented to the house the filter should be inside the unit at the top or bottom.\015\012Phil ... Air Conditioners

Heating and air condition unit will not kick on when i try to turn the heat on in the morning. we have tried the auto fan and the on fan for both ac and heat...will only work for the ac. the breaker switch at the breaker box is the only solution we have found to get the unit to fire up and to start the heat for the unit...my brother has checked the wiring at the thermostate..mercury type..found no burned out wires...he changed the filter on the system...tried to clean all the contact points on


Hello , I can help you out here. First check the T-stat with all breakers on take the red t-stat wire and white t-stat wire and green t-stat wire , tie the 3 together and wait 5 minutes to see if anything starts up. If the heat starts running replace ... Air Conditioners

Hi, I have an art cool LG 2 HP split system, (non inverter) and was installed in Dec 2004. The property is rented, however, the tenant is saying that it is not very hot, even though she has set it on 30 degrees. I have cleaned the filters inside the unit on the wall, but it still seems to be giving out warm to cool air. Is this common for LG units of this kind?


No this is not common performance.\015\012\015\012LG units are great little systems and typically (if sized correctly) provide plenty of cooling for the desired space.\015\012\015\0121) As for being 'sized correctly' you menti ... LG Art Cool LA1000PR Air Conditioner

The outside compressor and fan will not shut off. I have turned the thermostat system to Off and even to heat, but it will not stop. I went on a trip, increased the room temp to 80 on the thermostat and left. When we returned 2 1/2 days later, the coils were frozen and no air was comiing through the vents, even with the blower motor working. So I turned the unit to furnace and melted the ice on the coils, but had to pull the fuses on the outside box to get the compressor to shut off. Is there a


Sounds like the contactor is stuck. That's why nothing will stop the fan and compressor except killing the power to it. You should be able to get one fairly cheap. ... Ruud UAKA037 Air Conditioner

Can Carrier split system 38G250H be converted to be controlled from a room thermostat rather than the return air thermistor. I have a very high ceiling ,2m above the indoor unit,and the stratification is a problem. I have already the ''Butcher'' ceiling fan installed and it is still cold at the floor level, and 27deg.C at the unit level.(2.4 m)


Yes it can be done as long as the thermostat has the capability of acting as a on-off switch.It could be bimetallic type which till today are the best way of tep control since the inherent qualities of the bimetallic strip is that any temp change co ... Air Conditioners

DeLonghi Split System Reverse Cycle Air Conditioner Model CP605AU Output 8.15kw I have just purchased a second hand unit and require a manual for this unit. Can I down load, when purchased it stated no gas,will there be a problem in installing this unit, can you suggest someone near Salt Ash NSW.


... DeLonghi Air Conditioners

I'm a 35 yr home builder in northern Ohio. I built a new house for myself two years ago and had my HVAC contractor install a trane system, he nat gas furnace, a/c, electronic air filter and trane humidifier. Starting my third winter here and the humidifier has never ran except in the test mode. They have been back out 3 times and say everything is working properly. I set the humidistat on the highest setting and it has never ran, except test mode. I can't get any sweating on my windows at


It's supplier responsibility to make the unit right. are you controlling your dehumidifier with remote, If so, remove battery in remote and reset it. And then check. If still problem, please get manuals fro the following site and do accordingly ... Air Conditioners

Can anyone give me an installationset out for for a brivis M30e Gas central heating system ie the size ducting needed for return air vents outgoing vents and sizes before you can drop down is size. I have had a go at installing it but I think my ducting size my be all wrong


Welcome to Fixya\015\012\015\012Sir\015\012\015\012I hope Following Link can help you\015\012\015\012Complete the form to get ... Air Conditioners

My system uses a permanent air filter that is missing. The Model is RUUD UBHB-24J18SUEA. I can't find any literature on it. Is there an owners manual out there somewhere?


... Ruud UBHC Air Conditioner

Need wiring help on wiring a 1994 Marine Air system to a Cruiseair SMXII control box


... Air Conditioners

Loud noise from air return in living, sound like a turbine fan noise, louder than any unit from return duct that I have had in past 4 ton unit installed yesterday


... Goodman Air Conditioners

My Rinnai says not to use it without an air filter and to clean the air filter once a week--but I can't see an air filter. Is it possible that it was installed without one?


If you have a RHFE263, 431 or 556, the air filter is located at the top in the seam where the wall trim piece attaches to the heater. It looks like a dryer lint filter. ... Rinnai EnergySaver 556 Air Conditioner

The air exchanger for my AC is in the ceiling of my condo. It requires a 20x25x1 air filter which I have. The filter has an up pointing arrow that says 'air flow.' Does this mean that the filter should be installed with the arrow pointing up? Or pointing down? Thanks!


Yeah, the arrow tells you the direction so it should be going up. ... Air Conditioners

Am having a Tappan Split system heat pump installed. Proposal was for a 14 SEER system including a FTBD042K heat pump and a BCS2M48C variable speed air handler. However Actual equipment installed is FT4BD-042K and B5BM-X49K-C. The Yellow Energyguide shows SEER 13.0 & HSPF 8.0 Am I getting ripped off, with an installation of a cheaper less effecient system?????


I dont think so that variable speed air handler is a nightmare when(not if) that motor goes bad its 700.00 to 900.00 the regular 3 speed one your getting 125.00 and it will last 10 to 15 years ....... if you realy want fun install a 17 seer system ... Air Conditioners

My toshiba split system will blow cold air for about 30min then it will blow what seems to be cool air but not air con cold air when it is quite hot outside. The timer light operation and filter light will flash. I have turned it on and off reset remote cleaned filters. When it's cooler outside it seems to work fine???


... Fujitsu 9RLS 9000 BTU Split System Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific