Having problems with your Air Conditioners ?

I have a Haier ESA3067 air conditioner that has worked fine for a couple years. Then it began to have trouble responding to the pushbuttons to raise and lower temp, etc. Now it has stopped running altogether. When the unit is first plugged in, the display lights up "88" for a few seconds, then goes dark. If the GFI on the cord is tripped and reset, the display stays dark. It will not respond to pressing the on/off button. Can the problem be fixed by replacing the touchpad? Or is there ano


Answers :

Yes, rightly said that it is the main controller unit that hass failed . It will worth a try to remove the board and reset the touch pads once again after resolderring on the connecctions of the microprocessor and the connectors to the display.
\015\012Check the main +5 volt to the micro processor, check the filter and regulator if the voltage is down.
\015\012If not a replacement board can be thought of , but a trail spare to confirm ultimately will be worth unless you can confirm if the mP is not oscillating at all.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a Haier ESA3067 air conditioner that has worked fine for a couple years. Then it began to have trouble responding to the pushbuttons to raise and lower temp, etc. Now it has stopped running altogether. When the unit is first plugged in, the display lights up "88" for a few seconds, then goes dark. If the GFI on the cord is tripped and reset, the display stays dark. It will not respond to pressing the on/off button. Can the problem be fixed by replacing the touchpad? Or is there ano


Yes, rightly said that it is the main controller unit that hass failed . It will worth a try to remove the board and reset the touch pads once again after resolderring on the connecctions of the microprocessor and the connectors to the display. ... Haier ESA3067 Air Conditioner

A/c was wrk.now it keeps tripping cord breaker .control panel not lighting up.when press reset can hear click in control panel but still trip cord breaker.jumped comp. tries to kick on but trips cord breaker.


Is it 220 if so check if you 120 on each pole and should be on a dedicated breaker at least 30 amps. make sure you have a good ground.even on 120 you must have a good ground. or the cord breaker is bad. but check all the above. make sure there no los ... Whirlpool ACD052MM Air Conditioner

I have 2 Frigidaire window a/c units, model# fam18eq2a1. The landlord tells me they are brand new. Both units have the same symptoms: about 30% of the time they power on and function normally. The rest of the time nothing happens when you hit the power button. After checking the appliance plug in to make sure is plugged in, I then hit the reset button, afterwhich the digital display lights up completely, beeps, and then usually goes dead, although 1 out of 15 times it will power on and cool f


... Air Conditioners

I have a Samsung Window Unit model AW12EC87. There is no power at all on the display. The light on the plug is on and goes off when you press the test button and comes back on when you press reset so I know the unit is getting power. I do not have the owners manual


... Soleus LX-120 Air Conditioner

Unit shut off by itself. unpluging and replugging With reset of CB(not tripped). Unit beeps 10 times. Blue light comes on and goes off then nothing. Repeat with plug gets same result


... Haier CPN10XCJ Air Conditioner

Hello I have a TH232 programmable thermostat that manages my underfloor heating. Recently, it started randomly resetting itself whenever it calls for heat, i.e. when there's a light click. It then goes through a cycle of displaying everything on the LCD screen, then a 17, a 13 and then back to where it was. This also happens whenever I press ANY button on the faceplate. I am trying to contact Honeywell too, but they only seem to be based in Canada or France. Any ideas? Thanks DIY Don


Hi, The problem is caused by a weak power supply from the module behind the 'stat. When it calls for heat, and it tries to operate it's relay, there is not enough power to do it, so the voltage drops and causes the 'stat to cut out. Then the volta ... Air Conditioners

The window unit has ran for 3 years never tripped the breaker now it only trips the reset button on the cord does not trip the breaker when i reset it it works great for a while it stormed the night it started this


Well they do go bad was it eclectic storm it might have fired it. but make sure the unite is clean both front and back if have air compressor blow it out,Ok! hope this helps Paul ... GE AVX10AD Air Conditioner

I have a GE air conditioner with the power surge included in the cord (attached to AC) where it plugs into the wall with 2 buttons. The air conditioner got struck by lighting and when we push the reset button, it does not reset, and the yellow light blinks.


Need new cord the gfi in cord has gotten burnt inside ... Air Conditioners

My frigidaire air conditioner cord got wet while being used and now it will not turn on. the end of the cord has "test" and "reset" buttons on the side of where it plugs in to the wall. the test button does nothing. the reset button does nothing when pressed in all the way but when slowly releasing the button the light for power will come on and blink power to the air conditioner repeatedly every second. nothing will stay on for more than 1/2 of a second and the fan will not start up at all.


Hello\015\012I would have the cord replaced.The test and reset is a ground fault,or a saftey device.\015\012If its not working correctly then have it replaced ... Frigidaire FAC124 wall/Window Air Conditioner

Everstar mpm2-10cr-bb6 will not reset on power cord. light on reset doesn't light. seems like no power is getting to the unit.


Check the outlet that the unit is plugged into, to be sure that it is in fact, working. The circuit breaker in your home's circuit breaker panel for that outlet, may have tripped. Also, the outlet may have interior damage or a loose wire connection. ... Danby DPAC8020 Air Conditioner

I have a amcor model PLM1300E and the gfci on the end of the cord will trip for no reason that i can see, when i reset the button eveything works fine for a little while and all then it will trip again? i checked the connections inside the cord and eveything is tight, what could it be. thanks for the help


Additional information: I found out that by setting the [email protected] degrees or lower, the unit does not trip the gfi if that is any help. I didn't want to have to run it by turning it off when it gets too cold, and sleeping under a comforter. It does ... Air Conditioners

I have a Goodman Model GMS80703anaa- For the last 5 days I have had to reset the furnace, now it won't go on at all. The ignitor trips, the thermostat trips, blowers go on, but no flame/heat. When I reset it, it works for about 12-24 hours....now it is not registering at all. I have read the other reviews regarding Goodman furnaces, and it tells me to look for a blinking led light on the control panel. Where would I find this? I do not see anything blinking when looking into the furnace, and whe


They should have said located on a control board.\015\012This is usually located behind the bottom door where\015\012the blower motor is located. It usually is mounted in\015\012front of the blower.\015\012\015\012On the ... Air Conditioners

My ariston boiler displays a red light and A01 fault code. It fails to ignite. Sometimes I can press reset and it will light but this is rare and at mostly even the reset won't get it to reignite. The booklet helpfully tells me it is an ignition fault, but what is causing it?


... Air Conditioners

The boiler locks out, i reset it the left hand green light is on and the red centre light the temp gauge is showing zero. i run the hot tap and the boiler starts up and the temp goes up then i stop the tap and the central heating starts and keeps going until it locks out again(about 90 deg c) - centre red light on and right green light and lockout light. temp gauge then drops right down again and i have to run hot tap again to start central heating. any ideas?


Hi,\015\012It would be helpful to us if you had includes the make and model of the boiler that you are talking about...\015\012\015\012Is it gas or fuel oil???\015\012\015\012My impression from what you have said is that ... Air Conditioners

Amana #PTC153b50AJ ser 0410686783 Customer heard a pop in unit and it went off. Breaker was tripped. Reset breaker and unit runs in a/c mode but does not heat in heat mode. This is not a heat pump but electric heat strips. Unit says there is a manual reset for the heat but we have not located the reset. We turned power off to the unit to reset fault etc and still no heat. The flashing light just blinks once every 4-5 sec. Could use some help in diagnosis Thanks DK


... Amana PTC153B50AJ Electric Heat Air Conditioner

Model PE1-09R-30 SoleusAir Portable Air Conditioner: Power Plug in light flashes on and off and clicks when reset. Test button turns light and clicking off. On/off switch on unit does not turn fan off when power is on with plug light flashing and clicking. It does turn display lights and on and off.


Hi,\015\012This is the link to download the service manual for your product. Hope it will be helpful to you. \015\012http://www.managemylife.com ... Soleus Air Conditioners

What is the error code EP on a GE window air conditioner? This air conditioner stops cooling and displays the error code EP......we have moved controls, checked breakers, checked plug, checked trip and reset on plug.......then sometimes it will display digital temp and start cooling again only to cut off cooling in a few minutes, few hours or it may run all day before displaying EP again....


Hi\015\012\015\012Unplug the machine and plugin after that push the reset button…Hope the machine will work.\015\012\015\012Let us know if you have something more to know else please accept the suggestion.\015\012 ... GE AGW18DH Electronic Room Air Conditioner

Unit keeps tripping breaker everytime i put the power to it. was working fine then began to trip the breaker. power supply cords test okay, but each time i reset breaker the unit comes on for a couple of seconds and then trips the breaker.


Hi, It's drawing too many amps. Could be a shorted wire, bad fan motor, or a bad compressor. It could also be the relay in the outside unit. One side of the relay could not be contacting.I would pull the disconnect outside and look at the co ... AmcorAire UCHW-H24AF2 Split System Air Conditioner

I have a Viessmann Vitodens 100 boiler. There was a water leak on the water flow switch which got fixed, however when I have try switching on the power, there is no display or reset light. The fan (I assume it's a fan) is constantly on however I am unable to reset the system. Usually in the past when I have had to top up the system (due to the leak), I have had to reset the 'red' button, however this is not lit. Please can you advise? John


... Air Conditioners

I have an air conditioner Appliance AAC 1100 A-PTC that wos working for two days and now its not cooling or heating:-( Both outer and inner parts of the machine seems to be running but it wont heat or cool the room. When i try to turn it on there is a red symbol that lights up on the display (defrosting) this light goes off every 5 minutes or so,then the machine starts to blow air (not heated or cooled) for aprox 20 seconds then the red light comes on again and this procedure starts over again.


... Air Conditioners

Th 132 af floor heating controller not working. the unit is nearly 3 years old and until now ihave had no problems with it. i put the controller to holiday mode in the spring and recently noticed there is no display on the unit.the supply has not tripped, i have removed the display from the backplate whitch it connects to hoping it might reset and come back on but no joy the display is still blank! any ideas


... Honeywell Air Conditioners

Unit will not turn on...no fan, no heat, no cool. Reset button on cord trips when plugged into outlet. It's 4 years old


Check out these three main causes of a portable/room unit's failure:\015\012 ... GE Zoneline AZ38H12DAD Split System Air Conditioner

Ac wont come on trip plug lights for 1 sec then goes out.


QUESTION?? WHY DAEWOO?? DID YOU EXPECT ANYTHING ELSE? ... Daewoo DWC-056CL Air Conditioner

Maytag M6Y12F2A-E Power Cord does not work properly. When reset button is pushed nothing happens. If I hold it down for a few minutes the light flashes green. Unit does not come on. Please help me figure out what is wrong with unit. Can the power cord be replaced and if it can, where can I find the part.


... Maytag M6Y12F2A Air Conditioner

We have a Britony Combi Boiler SE 80 and the pilot light will not come on. We've reset it and it comes on then goes off again and the temperature lights on 40 60 80 keep flashing. I've rang my insurance company for an engineer but they can;t come out until after 9.00 am tomorrow (Monday) morning. I have two young children and how have no heating or hot water.


... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific