Having problems with your Air Conditioners ?

Hello, my HVAC is constantly freezing, even after freon is added. I was told that I have a leak in the coils and need to chance the air handler - the outside unit is about 10 years old - air handler about 18 years old. I would like to get only the air handler for my R22 outside condensing unit. My question is if in the future can I use this same 3.5 ton air handler with a new 410 condensing unit once my outside unit needs to be replaced. In other words can a Goodman air handler be used firs


Answers :

I'm new at this and I can't tell how old the post is but I'll contribute anyway.
You probably have fixed the problem by now. I wonder what part of the system is freezing up. I don't have a lot of experience but I know you can get frost where there is a restriction in the freon. If the freon line filter near the outside unit has frost on the house side the filter is partially plugged. I have also seen fost on the evaporator (attic "A" coil) when there is a shortage of return air flow. You could have a plugged filter or colapsed return duct, or even an "A" coil with a lot of dust covering and plugging the fins. I guess restrictions in your room air supply registers could cause the problem too. Maybe you have most of the vents closed off to save energy. Just some possibilities.
Hi,
\012No you can not use a R-410 air handler with a R-22 condenser unit...the exspansion devices are different as the properties of the refrigerants are enough different that they are not interchangable...
\012Really your only choice is to replace the whole unit as it sounds like the exspansion valve or the orfice is partially clogged and it makes you constantly freeze up....
\012There are some things you could do to make it work at reduced capacity but it is way beyond what I could tell you through a computer...
\012
\012heatman101

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Hello, my HVAC is constantly freezing, even after freon is added. I was told that I have a leak in the coils and need to chance the air handler - the outside unit is about 10 years old - air handler about 18 years old. I would like to get only the air handler for my R22 outside condensing unit. My question is if in the future can I use this same 3.5 ton air handler with a new 410 condensing unit once my outside unit needs to be replaced. In other words can a Goodman air handler be used firs


I'm new at this and I can't tell how old the post is but I'll contribute anyway.You probably have fixed the problem by now. I wonder what part of the system is freezing up. I don't have a lot of experience but I know you can get frost where there ... Goodman CKL42AR42 Air Conditioner

We installed a 4 ton downflow coleman air handler with evap coil Model number 1854s2m we did not change out the outside unit. the outside unit is a 13 year old 3 1/2 ton intertherm condenser the system is only generating a 10 degree delta T. My question is, this coil came with a factory TXV I am trying to find out is this a 10 seer or 13 seer coil is it compatable with the outside unit.


You have a missmatched system, for it to work try removing the orfice on the high side txv it is not allowing the evaperator coil to fill with refrigerant properly coleman and intertherm dont like each other since they control a large market in the ... Air Conditioners

Five year old goodman unit compressor gone bad. Should I just replace the compressor or should I get new air handler and condensing unit. Really don't want to spend the money, can really use it somewhere else.


Depends on if your going to stay with the old refrigerent system of R 22 ro upgrade to the new R410A system. I have been upgreading my customers to 410A if the compressor has failed. Replacement of all components recomended on a compressor burn out. ... Goodman CKL42AR42 Air Conditioner

GOODMAN AIR HANDLER MODEL CA*F4961*6A*+MBE2000**-1 HAS HEAVY CONDENSATION IN THE TOP OF THE UNIT WHERE THE ELECTRICAL /CIRCUIT BOARD IS LOCATED.THE UNIT IS LESS THAN ONE WEEK OLD. THE COMPANY THAT INSTALLED IT HAS CHANGED THE DIP SWITCH SETTINGS AND TODAY PUT IN LARGER COLD AIR RETURN DUCTS.STILL IS THE SAME.ALSO THE COILS UNDERNEATH HAVE HEAVY CONDENSATION ON THE BOTTOM OF THEM.WHY CANT THEY FIX THIS ONE WEEK OLD UNIT.THE OUTSIDE MODEL# IS SSZ140601A*THE HOUSE IS 2480 SQ FT. THE OUTSIDE UNIT IS


This is not even a repair issue.If it is hot out and it's on quite a bit,there will be much condensation.However,condensation on a circuit board is never good.Since it is only 1 week old and you can see this serious of a potential problem,especially ... Goodman Air Conditioners

Ruud UPNE- 036JBZ 2 years old (outside unit) Ruud Acheiver air handler 1 year old inside unit... outside unit will not come on. voltage (120) ready at contacts. push manually and it comes on. yellow wire and brown wire go to board. no power on these when inside unit is running. power bill has doubled......must be running off heater coils? What would be the next thing to check. I did look at thermostat seems to be working normal. Can't get knowledgeable help.


... Air Conditioners

I have an amana heating/cooling system. it is 3 years old. it has 2 fans/compressors outside the house that seem to operate fine. with all the hot weather this year we have used the air conditioner more than we typically do. i hadn't thought to change the air filter sooner because of the increased use. the filter was so clogged it got partially sucked into the air handler. i shut the switch off on the system and removed the filter to get the size off the filter. i closed the system back up witho


What you have done is restricted the air flow the water is most likely where the indoor coil is froze and you may need to clean the coil as well just from your symptoms shut unit down open the door of coil this is most likely in the shape of an A re ... Amana Air Conditioners

Just recently converted a heat pump unit into a straight cool condensing unit. My question is how to wire, my four wire(R-G-W-Y) battery operated thermostat into the air handler with a four wire jack(


... Air Conditioners

Air Conditioning I have a ruud system with the air conditioner outside and the air handler upstairs in the attic. My systems appears to be running, and I can feel cold air at the vents, but I can barely feel it. Like there is no flow. The fan outside is running and the unit in the attic is running. I have no clue what the problem is. The large coil coming from the heat pump outside is cold and has condensation on it. It also seems to have a little ice. It has been extremely hot here in Ge


Open the access panel on the air handler in the attic and take a look at the evaporator coil. If you have no airflow, and you just changed the air filter, then you probably have a buildup of airborne crud on the coil that's blocking airflow. \015\01 ... Ruud UAKA030 Air Conditioner

I have a Trane XE 1100 outdoor unit. I had to refill the freon gas 3-4 times in 3 years. The technician mentioned that I need to replace the outdoor unit. last night, the outside unit was running and the unit in the attic was running and the copper pipe was cold and wet, HOWEVER no air was coming out of the vents all over the house. Do you have an idea WHAT IS THE PROBLEM ? My question: Do you have an idea How much it costs to replace the outside unit ?


... Air Conditioners

Hi: I have a Carrier 38CMC42300 AC unit which will not turn on and the air handler is blowing hot air. The 40 amp breaker for the AC unit trips right away when reset. Could this be a condenser or motor problem? Note: an assessment by a service tech has recommended the whole unit be replaced (it's 8 years old). Any suggestions are welcome.


Hi,Your compressor or the start components are bad...\012\012Here is a tip about troubleshooting your air conditioner...There are many things that can cause your air conditioner not to cool... ... Carrier 38CKC036 Air Conditioner

Have Coleman-Evcon heat pump system. Model DRHS0421CB. Condensing unit has intermittent no run condition. I replaced the contactor, as it was a few years old. I eliminated the thermostat from the equation by twisting together the RYO wires at the thermostat sub panel. This makes the air handler run and MOST of the time also makes the condensing unit come on as well. When it does run together, it cools great. Suction and discharge pressures are normal. The float switch is ok and no water prese


Elimate the items not needed to test the unit.\015\012Disconnect the defrost power board and set air handler to run.\015\012Disconnect the thermostat and hold contactor switch in closeing connections to the compressor and condensor fan. ... Air Conditioners

There is a condensate build up in my Trane XP 100 Air handler located in my hot Florida garage. The unit sweats on the out side and inside water drips through the heating unit which now shows rust marks and onto the squirrel cage fan. Condensate water is then splahed onto the fiberglass insulated walls of th air handler. Mold is beginning to build up both on the inside walls and on the fan unit. The air handler performs fine. My home is kept cool, but I am concerned about this condensate and


This is complicated, as you know condensation can not be avoided when cold air comes in contact withhot humid air. Here is what I would try. You have to gain access to your evap coil. Which means tearing into the sheet metal cover. The updraft ... Air Conditioners

The fan in the condenser unit appears fine its a CM42-1CE, 20 years old, The pipes between the inside unit and outside unit do not get cold? The air temp is room temperature .


Have you checked ... Goodman CLQ36AR49 Air Conditioner

Hello. I have a RUUD-UBHA-21J18SFBA electric furnace with a 3-1/2 Ton condensing unit and matching A-coil. The furnace (air-handler) has the a-coil attached to the bottom and was initially used as a downflow system. Can I convert theis system to an horzontal flow system? If so, can the a-coil be removed and rotated so that the condensate pan will then be on the bottom again, thereby allowing for the proper colection and removal of the resulting condensation? Thanks. Ray.


... Ruud Air Conditioners

This is a central air conditioning question. I have no power to the "battery-less" thermostat. I have two thermostats in the main house and swapped them out to see if one of the thermostats is bad, but both thermostats are working. There's just no power to the terminal in the living room. I checked the 5amp fuse to the air handler, and it's good. I checked the A/C unit outside and pressed down the contactor, the a/c kicks on. What am I missing?


Are you getting 24 volts from the thermostat to the transformer in the air handler? Sounds like the transformer in the airhandler. You can check it by taking the voltage from the R termianal to C Terminal and should read 24 volts. ... Air Conditioners

I have a portable air conditioner and the water condensation tank fills in about 4 hours of constant use. Is there any kind of portable water tank that I could attach to my unit that would allow me to empty the tank after overnight use rather than every 4 hours? I am hesitant to drill a hole for the plastic hose to drain outside. Thanks for your help.([email protected])


I would suggest putting a condensate pump in the reservoir, find the tube that empties the water into the reservoir and direct that into the pump. You can run tubing from the pump to a sink or any other drain in the house that is convenient. Puttin ... GE APN10AA Portable Air Conditioner

I have a Lennox CB29M Air Handler with an electric heater, which is used to heat the lower two rooms of my house. The handler unit is located in a mud room right behind the back patio. I'd like to get an air conditioner unit that can mount on the patio that can be hooked up to this air handler, so I can have air and heat in these two rooms. Are there units that are available that can work with this air handler? How hard is the install, and can you recommend anyone in the 19030 area that I can tr


Any of these Lennox dealers can help you choose a compatible HS29 or HP 29 condenser and evaporator coil to match your system.http://www.lennox.com/locate/default.asp ... Air Conditioners

Is it ok to replace outside unit of central air and heat and not the inside air handler ? The upstairs A/C( over 10 yrs old) is not keeping up with South Texas heat. The temp upstairs climbs to 84-86 degrees by the afternoon and takes 4 or more hours after dark to cool back down. I have cleaned the entire unit outside- no help. I have replaced the downstairs unit 2 yrs. ago and it works fine. I don't want to replace the upstairs air handler if I don't have to---much more cost.


I'm assuming you have had a competent Air Conditioning contractor look your unit over.if you trust your A/C contractor, why don't you work with them towards an answer? I would get an air flow and sizing analysis, a full equipment service/performance ... Air Conditioners

AC Out. Two year old house. Goodman A/C, two units one for upstairs. Cleaned coils of both outside unit, replaced filters, re-set breakers. Upstairs is cooling. Downstairs unit is running outside, not circulating air inside (inside temp 87). Vents inside are cool to touch, no air. Outside unit fan is pulling, but air exhaust is cool. Compressor ? Should air be circulating even if compressor not functioning. Is there anything in attic exchange that would affect downstairs circulation. Thanks.


Assuming that the 2 systems are isolated, that there isn't any cross over between the systems...It is normal for an air conditioner system, from window unit to central, to be able to circulate the air, even if not cooling. This is known ... Air Conditioners

Mitsubishi Mr Slim: Hi, I read your response to a question from someone who had a Mr Slim that was leaking inside their house. I have the same problem. In your response you said to locate the drainage pipe and blow into it to clear it. Could you elaborate? I have three Mr Slim units in my house but only one is leaking. The outside condenser has six hoses or pipes leading into it, I assume three are air and three are for drainage. Is there any way of figuring out which is which? and once I


There should be a clear or white pipe comming out of the back of the wall hung unit. ... Air Conditioners

I have a Jantrol heat pump & A/C. It is approximately 10 years old. For the last 3 summers the compressor unit will freeze when the air handler fans fails to come on. It worked fine for 2 weeks this year before it happened. I've be able to thaw it out and restart the unit and it works from days to weeks before this occurs again. The last time it happen, I had a problem getting the air handler fan to come back on, but it did eventually. I've been thinking it may be the sequencer, but now I'm wond


Hi,\015\012\015\012If you can safely check the supply to the motor when it should be on, then this is the best method to check it.\015\012\015\012Check the fan turns very freely - oil the bearings if it doesn't.\015\012 ... Goodman Air Conditioners

Leaking Mitsubishi Mr Slim: I read a response to a question from someone who had a Mr Slim that was leaking inside their house. I have the same problem. In the posted response the person was told that their drainage pipe was probably blocked and they should locate the drainage pipe and blow into it to clear it. Could anyone elaborate? I have three Mr Slim units in my house but only one is leaking. The outside condenser has six hoses or pipes leading into it, I assume three are air and three are


Hello my name is Heath it will be my pleasure to assist you. The drain line shouldn't be hooked to the condenser. It will run from the bottom of the unit either to a drain in the house or to a pump that will pump the water to a drain. If you pull the ... Air Conditioners

My coleman 13,500 roof a/c year 2000 does not blow as cold as used to. I have cleaned the top condenser coils, with no help. It also at times will seem to pull a heavy load when I assume the compressor kicks in, very heavy that the generator bogs way down, then runs free, i believe the compressor is shutting down as cooling worsens, it was 85 outside and the coach continued to get warmer. The AC unit has shut down completely before, not sure why I waited 30 minutes and it restarted.


If the compressor started and stoped means \015\0121 thermostat need settings \015\0122 compressor over heated due to low suction pressure need to check and repair the leak then charge the freon ... Coleman Mach III Air Conditioner

My goodman ac seems to be no cooling. i have new filter and drain line is vacumned. i changed a chip board about a year ago. the fan on the air handler is working. condenser is running outside. the thermostat reads80 and i have it on 78. its a honeywell digital


Is the compressor and fan running outside ? Is the large copper line going to the outside unit a little cool or noe at all ? Sounding like low on refrigerant. ... Air Conditioners

My goodman ac unit is not blowing cool air inside, well not hardly blowing air at all but the outside unit is blowing cool air outside


... Goodman Air Conditioners