Having problems with your Air Conditioners ?

I replaced my filter on my Coleman Mach 2006 year model with a reusable 7x16 and it is frezzing up. The original filter was a 16x16 and appeared to be much thinner. I replaced it with 7x16 because that was all that was available and that is about the size of the return air inlet. The problem is my ac lines now begin to freeze if it doesnt cycle quick enough. Could the air filter be the problem? Is it to thick?


Answers :

Your new filter is restricting the air flow to much go back to the origanal filter

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I replaced my filter on my Coleman Mach 2006 year model with a reusable 7x16 and it is frezzing up. The original filter was a 16x16 and appeared to be much thinner. I replaced it with 7x16 because that was all that was available and that is about the size of the return air inlet. The problem is my ac lines now begin to freeze if it doesnt cycle quick enough. Could the air filter be the problem? Is it to thick?


Your new filter is restricting the air flow to much go back to the origanal filter ... Coleman Mach 15 Air Conditioner

Just cut on 8 year old Goodman CPLE24-1 AC for the summer. Ran 8 hours fine, Next morning noticed outside unit running, very little cool air blowing out of inside floor vents (like the blower fan was broken). Outside unit frozen. Capicitor replaced last July. (2) separate filters inside house returns clean. Whatz the problem? Help? Advice? Gotta fix it fast! By myself hopefully. Thanks!!!!


Due to the many different questions I see about Air Conditioning, I am including this overview to help us better understand each other for trouble shooting. A basic air conditioning system has a Thermostat, Air Handler or Furnace Fan and a Condensin ... Goodman CPLE24-1 Air Conditioner

My central a/c has a problem with water dripping from the cooling coils and getting down on my air filter below. The filter then turns black with mold. I have a very expensive filter (Aprilaire) so replacing it all the time is a problem. The a/c cools the house fine. The drain isn't clogged and the filters are new. What is causing this and how can it be fixed?


You should tilt the system such that the water goes directly to the drainage pipe. it is easy however it may require a hany man.Regards ... Air Conditioners

Does the RUUD UBHA14J11SFAA air handler have a filter which needs cleaning or replacement? I change the cold air return filters regularly but have never serviced the air handler in the ten years it has been running.


... Ruud Central System Air Conditioner

I have been working on a Goodman Heat pump. The indoor coil keeps freezing. Outdoor temp is 70F and indoor is 78F. It has a brand new air filter. My superheat is 2F and subcooling is 10F. I have replaced the blower motor. This is a 2.5 unit, my return duct is 12x14, there is a return grill at the return side of the furnace 8x8. It has been working fine for the last couple of years. If I take freon out my superheat become -2. I think I got an airflow issue, and that's why I replaced the blower m


HelloIs there a high speed setting for the blower motor.Check the specs on the rpm requierd for the unit. ... Air Conditioners

I have a 4-ton Frigidfaire air conditioning unit on my 2400 square foot home, but I am not receiving the cooling I should receive. My split system model is #: FT4BF-048K. My air handlers Model is #:B4VM-X48K-C. I suspect my problem may be duct size. What should be the sizes of supply and return ducts on this unit? Phone 941-776-9270.


Hi, the ducts are 18" round at the beginning and branch out to smaller sizes for other rooms. 10" for living areas, 8" for bedroom, down to 6" for bathrooms if they have them.If this unit was just installed, I would recommend getting the contractor o ... Frigidaire Air Conditioners

Hi guys, i have a portable air conditioner 9000btu 'ariagel ag90' window) that works great for the first 5 minutes, until gradually the unit makes more and more noise until it shudders quite violently , returns to its normal noise and blows out hot air for 5 minutes. This hot air seems enough to cancel out the cooling it does. then after a while it cools gradually I've read alot about this air con problem, but nothing regarding the gradual noise and shudder. The slide out filter at the back s


This is due to the compressor going into thermal overload, It can be cause by really dirty coils preventing air flow,A restriction in the cap tubes or orafice, Or an over or under charge in the system.The noise is due to the compressor building up to ... Air Conditioners

Carrier furnace I have been having an enormous amount of dust in the last 8 months and wonder if it could be my furnace. I have replaced the filters to the returns monthly and have purchased an air filter and checked my drier vent but no solutions so far. .


Furnaces do not generate dust. Dust comes from air born polluters, such as near by construction, heavy flow of people, or seasonal. If this problem persists you can check into an air purifier. I am an Ecoquest dealer and can ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

I have a ten year old carrier heat pump unit. I recently replaced the indoor tstat. the outside contact and the transformer. Had a tech put freon in the unit also. I have to problems one is the airflow is minimal coming out of the vents it has new air filter and I cleaned the inside and outside unit coils. And the second problem is the ac with not get cold.


Two things are the most likely culprit. First check ytour inside coil with the unit running for 10 minutes or more and see if the coil is sweating there should be water running off of it. Also after one hour is there ice forming on it. These problems ... Air Conditioners

In Dec 07 I had a complete Carrier AC/Gas Heating System installed in my home to replace my original system when my house was built in 1983.We upgraded the new system to 3-TON AC as the old AC was 2 and half ton. Since the new system was installed in the winter time it was not until the hot weather started in May that a problem arose. The first conclusion of the problem was that the coil was aligne incorrect the second was that we needed more air return so an addition vent was added. No


Air conditioning requires 400 cfm (cubic feet per minute) per ton of cooling so your old 2.5 ton system would have required 1000 cfm and your new 3 ton requires 1200 cfm. This is not a big change, but if your ductwork is too small it could cause pro ... Carrier Air Conditioners

OUr air conditioning system works well until the circuit breaker trips. We added another large return vent in the hall to try to get more air circulating and that didn't work. We just replaced the outdoor airconditioning unit and the circuit trips again. The electrician says the wattage is fine. Any ideas what could be the problem. Everyone is baffled because the house is only 5 years old.


Current (amps) is voltage (volts) divided by resistance (ohms) or I=v/r. Breakers "trip" when there is too much current flowing through them. ... Air Conditioners

Regarding the installation of the f500 honeywell filter system. does the output of the filter system get ported into the return air prior to the air handeler? I had my unit installed today and i believe it was installed incorrectly. The input to the filter system comes from my return air box but the output is ported into the air box after the air handeler.


Hi,\012Here is a tip that tells you how to get a manual for most any Honeywell productonline...Manual Honeywell How to Find Honeywell Manuals ... Honeywell Air Conditioners

My unit has never worked properly as it is dripping water and ruining my wall and my filters. The business that installed my unit is giving me the run around and ignoring my requests to fix my unit once and for all. They have been to my house multiple times with different "solutions" to this problem. The last time I was able to get anyone on the phone from Air Masters, the owner told me that he would replace my unit with a new one, but that you guys would not stand behind your product. Now,


It's short of gas. That's why it's forming ice over the coil and cutoff by coil sensor and then blower only would run. At that time ice become starts defrosting resulting to this water drop. Call repairman to find the return pressure by gauge. 60psi ... Goodman Air Conditioners

My Dyna Pro 65,000 forced air heater will light, but then flickers and eventually blows itself out. I've replaced the air and gas lines as they were cracked. I also replaced the air filters, cleaned the gas filter and cleaned the nozzle and photocell lense. I've also put new fuel (kerosine) in the tank. Any ideas? Where do I go next? Thanks, Jeff


... Air Conditioners

MY frigidaire Air Conditioner model number: FAC107P1A2 has suddenly stopped blowing cool air. Check Filter light comes on but filter clean. Press Check Filter light button and blows out cool air for about a minute then blows hot air. Bought new at Lowes. Never had problem before with this air conditioner for 6 years! Please help burning up!


A few basic principles for air conditioner troubleshooting. For both central home air conditioner or window air conditioner,\015\012 the first thing to check is whether the unit is getting proper power. \015\012If the unit ... Frigidaire FAC107P1A Wall/Window Air Conditioner

I have an amana heating/cooling system. it is 3 years old. it has 2 fans/compressors outside the house that seem to operate fine. with all the hot weather this year we have used the air conditioner more than we typically do. i hadn't thought to change the air filter sooner because of the increased use. the filter was so clogged it got partially sucked into the air handler. i shut the switch off on the system and removed the filter to get the size off the filter. i closed the system back up witho


What you have done is restricted the air flow the water is most likely where the indoor coil is froze and you may need to clean the coil as well just from your symptoms shut unit down open the door of coil this is most likely in the shape of an A re ... Amana Air Conditioners

Central air My central air unit continues to freeze up on the outside, as well as on the inside on top of the furnace. I had it checked and was told the return flow was the problem and to take the fliter off and make the return flow larger. This has done nothing!!! It continues to ice over. Any ideas? Please..it is sooooooo hot here right now. Have never had a problem with this and all of a sudden it is freezing up. Thank you


HEY_ 2 viable options suggests them self to me, 1 - low airflow ----------2 low on freon charge! Thank-you-very-much! ... Whirlwind FH-778 Air Conditioner

Replacement filters? I have a sharp portable air conditioner.model# cv-p09fx. I have been on hold with sharps part dept for over 30 minutes. I've searched the internet high and low. I can not find the part number or part. For replacement air filters for this unit. Sharp has just now informed me that the do not carry the part. And suggested I call a sharp authorized dealer.(makes no sense to me?) I will also try that option. I am very burnt out on ideas or options, any ideas?...


... Sharp Air Conditioners

We have had a coleman central air system for 5 yrs. It stopped blowing cold air into the house about a week ago. You can still here it running but no air is coming out. my husband replaced the fuses and over night it did the same thing so when my husband went to check out the unit outside he said that the line had ice on it. Is there a filter within the central air unit that needs replaced?


Ice is an indication that the refrigerant is not flashing off correctly in the evaporator coil. In most cases you can simply turn the unit off (until it completely thaws inside and out) and replace the filter. Make sure that all the vents in the hous ... Coleman Air Conditioners

My frigidaire air conditioners spit dirt all over the floor. My window unit and my through the wall unit in a sleeve both do the same thing. I called Frigidaire two years ago and they told me there were no reported problems. I keep the filters clean and don't know what is causing this. My rugs and furniture are full of dirt particles when I use these units. I have had air conditioners for many, many years and have never experienced a problem like this. Please advise me if this is a problem with


1. Turn units off\0122. Remove Filter\0123. Spray a foaming cleaner on the coils (Dow Bathroom Cleaner)\0124. Use a spray bottle filled with plain water\0125. Replace Filter and Grill ... Frigidaire FAC124 wall/Window Air Conditioner

Central air only blows a small amount of cool air out the vents. After running 12 hours it only cooled my small 1BR apartment 3 degrees. The filter has not been replaced since October 2009 but I can't seem to get it out of it's little slot at the bottom of the unit. It's a Goodman Manufacturing Model Number ARUF024-00-1A. The air filter is loose but won't slide over the bottom metal lip. Is it okay to (a little aggressively) wiggle it out? Thank you so much!


I have a Goodman A/C unit APRF036-00B1. The out side unit seems to be sucking and bowing air, the coil is cool to the the touch and the blower seems to be turning. I've check what seems to be the obvious. A small amount of air is only coming out. Any ... Goodman CKL36AR36 Air Conditioner

We live in an apartment complex and have a Trane Air Conditioner, each unit has its own central air. I believe the one in our unit has clogged drain pipes, when we first moved in we didnt change the air filters and when we did, the filter was extremely dusty. My wife uses alot of powder and when I clean the drip pan below the grill where the drips into, I found a thick layer of whitish doh like crud.I feel like it is clogging the the 2 whites pipes that go from the drip pan into the drain down b


Hello You have to cut the pipe and blow out each end,You can use a 1"rubber hose from an auto parts store & 2 hose clamps, If you can't find the end.This will allow access in the future to clean out the pipes.It will slip over 3/4" PVC pipe.They sell ... Air Conditioners

I had the heating elemnt replaced in my unit and since that time I don't have the air flow volume I had before it was replaced and now I can't cool my trailer. The air is real cold (my vents is real wet) but I don't seem to get enough air to cool my trailer. What could be my problem? Model #PGB030075-1 and Ser #0104617125.


Some things that would change air flow in a system are:Blocked/Clogged Return Air. Usually a dirty filter.Blocked/Clogged A-Coil. Inside the coil box, you have to remove the cover that is on the coil itself, unless it's a down ... Goodman Air Conditioners

I have a Carrier whole house Air Conditioner I want to replace. It is model 38EN048320. @ things: 1. What "ton" is that AC rated at? It's so old I can't find what size it is so hard to pick a replacement. 2. With todays models they are all high efficency, should I get the same size replacement or can you step down a notch based on the efficency in models made today? I know a contractor would figure this all out but I'm doing this job myself as I have done this before.


1. 3 Ton Up To 4 Ton 2. You should get the same size - high efficiency means that for the same heat extracted from the residence the unit consumes less electricity than an older one. How much less is explained in the ratings: if your prese ... Air Conditioners

I have a Bryant Heating/Cooling unit. Serial # 4698E18469, Model # 597CN042-D. The water pump that pumps condensate out was replaced last weekend. A couple days ago, we stopped getting air flow. I replaced the filter, but the house still isn't cooling. I think there is more air flow, but it's not cold air. I'm not certain how to check the condensor or even if this is the first place I should look. Any advice? Thank you for your help! Rena


Hello,Is\015\012 the compressor motor running? The compressor is a football-sized case \015\012with no apparent moving parts. It is located inside the air conditioner \015\012at the center. Is it humming or making any kind of contin ... Bryant Air Conditioners

A detailed question is important to get you a relevant answers