Vulcan eco 120 stoped working, checked fault codes and it said hot serface igntier. i changed that and tryed operation, unit still dose not light. when i press reset fault codes say failure to light, but sometims it also says slow closung gas valve. how can i fix it?


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Vulcan eco 120 stoped working, checked fault codes and it said hot serface igntier. i changed that and tryed operation, unit still dose not light. when i press reset fault codes say failure to light, but sometims it also says slow closung gas valve. how can i fix it?


... Air Conditioners

My ariston boiler displays a red light and A01 fault code. It fails to ignite. Sometimes I can press reset and it will light but this is rare and at mostly even the reset won't get it to reignite. The booklet helpfully tells me it is an ignition fault, but what is causing it?


... Air Conditioners

Blue light flashing slowly reset button lit press reset button blue light still flashing does not reset worcester greenstar 24i combi boiler. need fault dignostic codes dont have them


... Air Conditioners

Amana #PTC153b50AJ ser 0410686783 Customer heard a pop in unit and it went off. Breaker was tripped. Reset breaker and unit runs in a/c mode but does not heat in heat mode. This is not a heat pump but electric heat strips. Unit says there is a manual reset for the heat but we have not located the reset. We turned power off to the unit to reset fault etc and still no heat. The flashing light just blinks once every 4-5 sec. Could use some help in diagnosis Thanks DK


... Amana PTC153B50AJ Electric Heat Air Conditioner

On ruud quiet 80 the fault code says ignition failure


Check for a bad hot surface ignitier, they generally will burn white hot and if bad may be cracked visibly with a grey area marking the crack.the unit will attempt a trial period for ignition 3 times and if not succesful will lock out. a pressure ... Air Conditioners

My haier air conditioner isn't working. The green light on the ac adapter is not turning on. i keep pressing the reset button and the light from the ac turn on for a second and it says E1. but it does not turn on. What can be wrong?


... Haier Air Conditioners

My unit's compressor will intermittantly stop working. The thermostat seems to keep the intake unit working but since it can't get the temperature down it never shuts off. We have been removing the batteries and letting the thermostat reset for 20 minutes. (thermostat Honeywell RTH23110B). After the reset the compressor will work again but will fault within a day. I am pretty sure that the compressor and fan are functional as if I press the contactor down it begans functioning. I also, to he


If the air handler coil is clogh , the air won't go through and the compresor will shut off on overload because of high head pressure, also this will happend if the condenser coil (outside) is blocked or if the fan dosn't work .Also if the outdoor un ... Air Conditioners

Stadt J-90EI ducted heater sometime doesnt turn on. when reset sometime works other time a red light flashes 5 times which on the board says "Flame Det"


Stadt ducted heater wont ignite ... Air Conditioners

We have a Halstead Ace High combi boiler with a persistent intermittent fault. ( 3 months.)It keeps going to 'lock out' - Sometimes it can be restarted by resetting but not always. Sometimes while just running the heating but also it will lockout when using the shower. We have had a new PC board fitted and 2 leaks around the manifolds and micro switches have been repaired. Every possible pressure (gas


Hi,\015\012\015\012You need to get a qualified 'Gas Safe' engineer to check the Venturi in the flue, and clean it out. The other thing to look at is the igniters, clean them wirth emery paper as this boier relies on flame rectification (i ... Air Conditioners

Heater stopped working. Fan works, control panel diagnostic check reports no failure code. Placard on front of unit says heater unit has manual reset, I can't find a reset button or breaker for heater. Help?


The front panel should be held in place by four screw at the corners or snap in place. Either remove screws or pull gently on top right corner to remove cover. You should see a red reset buttom type reset. Push it in to reset. Hope this helps. Thanks ... Amana PTC123D50AR Air Conditioner

We have a mater slave double boiler system. The master boiler will go cold, with no indication of the fault. Only a hard reset(powering off and on) will restart occasionally. Sometimes switching to the slave does a restart. We are also interested in an inexpensive lead lag controller to replace the simple Master/Slave Switch


... Air Conditioners

Working on a Carrier sx from 1990, has three wire bi-metal pilot with spark and 100% lockout on the spark module. Homeowner says it only fails in cold o.d. temps (less than 35 degrees). Home owner finds unit off and silent, resets 120v and unit re-lights and runs. Don't know what parts have been replaced so far but it looks like a new spark mod. and the pilot was clean but I cleaned it again. Limit switch looks old but I think limit failure would cause the blower to run. Any ideas?


Check the heater relay on the control board found in the blower part of this furnace. It's found in a steel enclosed box I'm having the same problem currently. I now have the blower running constantly set the thermostat to on not auto. until th ... Air Conditioners

My 15sbi boiler seems not to be turning off. The timer activation light says it is off, however the pump is not shutting off. I have tried turning the gas regulator off and swithing the unit off and on at the mains. I haave also tried a reset on the timer and reprogramming it. Any thoughts please?


... Air Conditioners

No heat, no flame, the furnace is going through its cycle, but the blower wont come on or flame.... the red led light on the cicuit board is flashing 4 times... the code for this says its an ignition fault..and to check the ground connection....followed the connection back to the armoured cable where the power is coming in and reconnected and checked all ground connections they are fine....the furnace is a g6rc frigidaire...what can i do..???


Is the pilot light on if not try relighting it. ... Frigidaire Air Conditioners

Have an amana 80 furnace blows but wont light now wont shut off . When I started testing it upper fan was stuck loosened it up. Then I reset the small button, fans started. But no heat. Then I cleaned up the heat sensor and igniter. now It wont shut it off unless I shut it of fthe breaker. Also It has a 5 blinking code. Does this sound like a thermostat? Thank you


... Air Conditioners

Furnace trouble Working on a Carrier sx from 1990, has three wire bi-metal pilot with spark and 100% lockout on the spark module. Homeowner says it only fails in cold o.d. temps (less than 35 degrees). Home owner finds unit off and silent, resets 120v and unit re-lights and runs. Don't know what parts have been replaced so far but it looks like a new spark mod. and the pilot was clean but I cleaned it again. Limit switch looks old but I think limit failure would cause the blower to run. Any idea


... Air Conditioners

Hello I have a TH232 programmable thermostat that manages my underfloor heating. Recently, it started randomly resetting itself whenever it calls for heat, i.e. when there's a light click. It then goes through a cycle of displaying everything on the LCD screen, then a 17, a 13 and then back to where it was. This also happens whenever I press ANY button on the faceplate. I am trying to contact Honeywell too, but they only seem to be based in Canada or France. Any ideas? Thanks DIY Don


Hi, The problem is caused by a weak power supply from the module behind the 'stat. When it calls for heat, and it tries to operate it's relay, there is not enough power to do it, so the voltage drops and causes the 'stat to cut out. Then the volta ... Air Conditioners

I have 4 header split type air conditioner. Time & again it stops and operation and timer light flash altenately and I have to to turn off the power at the switchboard and turn on again to reset. Sometimes this happens 2 or 3 times a day and other times it operates correctly for days. I have cleaned the filters and checked the electrical connections. 2 years ago I had a tech from Fujitsu who came and checked everything and could not find any faults. I am getting a bit concerned as this is occur


Hi,\015\012On the days it happens alot is there a temperature corolation??? Are these days warmer or colder then the days it runs all of the time???\015\012\015\012Have you checked the charge on the unit???\015\012Would there ... Fujitsu Air Conditioners

Delonghi pinguino PAC 250 U air conditiooner blows hot air. reset button must be constantly pressed in order to get normal cooling. also timer does not seem to be working


... DeLonghi PAC85 Portable Air Conditioner

Hi ...we have a split fujitsu air con for just over 5 years. The compressor in the outdoor unit is not starting up and the indoor unit blows ambient air. The operation light is lit and the timer light is continuously flashing when in use. Have reset the breaker and the units and also the remote to no avail. Can't find any info on the net or in the manual. Any tech help most appreciated. (Also doesn't seem to be a auto/manual reset buttn as such in the indoor unit)


There is a relay that the thermostat pulls in, in the unit outside. When this happens, the compressor pulls in and the unit outside will run. The compressor has to run before the unit will cool. ... Fujitsu 24C1 Air Conditioner

Ecu-Maxx Marine Air-Con. Compressor Load Fault Code (CLF) appears. Air Condition turns on but then after 2 minutes, I get the CLF code. Manuarl says it is Compressor Load Fault. How do I fix this?


Clean the filter on the water pump. It may be clogged. Even if there is just a little bit of gunk in there it can cause this error. ... Air Conditioners

I have the error code A77 on my ariston microgenus HE 28 boiler. I have looked at the fault chart and it gives you 3 options but does not tell you how to repair or test any of them. I have empted the condense trap and pushed the reset button but the fault code is still there. any ideas????


... Air Conditioners

THE RED (OPERATION) LIGHT AND GREEN (TIMER) LIGHT ON MY FUJITSU DUCTLESS AIR CONDITIONER ARE FLASHING. PRESSING THE START/STOP BUTTON ON THE REMOTE CONTROL DOES NOT MAKE IT WORK. SWITCHING THE BREAKER OFF AND ON SOMETIMES MAKES IT START BUT NOT ALWAYS. AFTER IT STARTS IT CAN STOP SUDDENLY, AND THE RED AND GREEN LIGHTS START FLASHING AGAIN. THE RED LIGHT FLASHES 6 TIMES, THEN PAUSES, BEFORE FLASHING 6 TIMES, WHILE THE GREEN LIGHT FLASHES CONTINUOUSLY. INDOOR UNITS MODEL #ASU12D1. OUTDOOR


... Fujitsu Air Conditioners

We have a Rinnai Timberflame FS 35 ETR gas fire that keeps tripping out, mostly on fault 12 (flame failure). We've had a number of gas fitters trying to repair it. Parts replaced include the pilot burner, injectors and the flame rods. After a service it runs reliably but after a few weeks the fault 12 becomes more frequent. The fault is sometimes intermittent. Generally, the fire is more reliable at colder temperatures and faults when reaching set temperature. Occasionally fault 11 occurs on sta


... Rinnai Air Conditioners

My Fujitsu Converter Air conditioner is not working... The Green light is flashing 13 times - the red light flashes continuously very quickly. The fan does not commence at all and therefore no heat or cool air comes from the conditioner at present. Also, once I press the start button on the remote control unit and the light being to flash, I am then unable to stop the unit - even after pushing the start/stop button - the lights continue to flash. Is there something I can do to make the air c


... Fujitsu Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0917 seconds