Having problems with your Air Conditioners ?

MY frigidaire Air Conditioner model number: FAC107P1A2 has suddenly stopped blowing cool air. Check Filter light comes on but filter clean. Press Check Filter light button and blows out cool air for about a minute then blows hot air. Bought new at Lowes. Never had problem before with this air conditioner for 6 years! Please help burning up!


Answers :

A few basic principles for air conditioner troubleshooting. For both central home air conditioner or window air conditioner,\015\012 the first thing to check is whether the unit is getting proper power. \015\012If the unit uses 220 volt power be sure that the proper voltage is \015\012getting to the unit. Same for 110 volt units. A voltage meter can be \015\012used to assure that the voltage is correct.

For window air conditioning units the voltage can also be checked before and after the thermostat.\015\012 If voltage is being supplied to the thermostat but not from it then the\015\012 thermostat probably needs replaced. This is a fairly common problem. \015\012Another place to check is the fan motor voltage. The fan on window air conditioners runs both the indoor blower and the condenser fan. If that motor fails than the compressor\015\012 may run for a short time, but will overheat and shut off. Continued \015\012operation like this will result in compressor failure. This motor can be\015\012 economically replaced for larger window air conditioners, but for \015\012smaller ones the cost of replacement will be more than a new unit.

Central air conditioners\015\012 for the home are more complex and there are more things that can go \015\012wrong. As with the window air conditioner the thermostat can also be a \015\012problem. The central air conditioner thermostat will only have 24 volts going to it. So don't look for high voltage there. Some units the voltage will be coming from the outdoor unit and others the voltage will be supplied by the indoor air handler or furnace. Most home central air conditioning will be supplied by the indoor air handler or the furnace. If the air conditioner is for cooling only the unit will usually have only two wires going to the condenser unit. Make sure that you have 24 volts across those wires.

The\015\012 next thing to check will be the indoor blower. If your thermostat is \015\012calling for cooling then the indoor blower should be running. If there \015\012is no air moving across the indoor cooling coil then you will soon have a big block of ice formed on the coil.\015\012 This can happen for a few reasons. The indoor blower is not working, \015\012the air flow is restricted and not allowing air to move across the coil.\015\012 A clogged air filter would also do this. Or the outdoor condenser unit has lost the charge of refrigerant.

Finally and worst of all is when you have a complete compressor failure. Often when this happens the compressor will "lock up" or not be able to turn when power is supplied to it. Overheating or lack of lubrication are usually the main causes of compressor failure. Overheating can be caused by the outdoor coil around the compressor getting clogged with dirt, leaves, or grass. Loss of the refrigerant charge will also cause the compressor to overheat. It is the cool return gas coming back to the compressor that helps to keep it from overheating.

As\015\012 you can see there are many things that can go wrong with an air \015\012conditioner and I have not come close to exhausting the possibilities \015\012here. I have just touched on the most common problems in a very basic \015\012way.
There are some basic trouble shooting things that can be done very easily. Most\015\012 problems are above out of the range of comfort for many homeowners and \015\012professional help should be consulted before any attempt is made at \015\012repairs. Remember also, that the release of refrigerant gases into the atmosphere is a federal offense in the
US. Proper care must always be taken to minimize the release of any gases. A license is also required to handle refrigerants. Make sure that the professional you call has the proper certifications to handle refrigerants properly.
\015\012
\015\012
http://www.fixya.com/support/r3636709-size_air_conditioner_need

http://www.fixya.com/support/r3623253-window_air_conditioners_clean_every_year

http://www.fixya.com/support/r3633369-portable_air_conditioning_great_portable

http://www.fixya.com/support/r3623166-heating_air_conditioning_scams

http://www.fixya.com/support/r3597468-you_can_add_air_conditioning_to_your_hot

http://www.fixya.com/support/r3583697-how_to_keep_house_cool_without_using_air

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

MY frigidaire Air Conditioner model number: FAC107P1A2 has suddenly stopped blowing cool air. Check Filter light comes on but filter clean. Press Check Filter light button and blows out cool air for about a minute then blows hot air. Bought new at Lowes. Never had problem before with this air conditioner for 6 years! Please help burning up!


A few basic principles for air conditioner troubleshooting. For both central home air conditioner or window air conditioner,\015\012 the first thing to check is whether the unit is getting proper power. \015\012If the unit ... Frigidaire FAC107P1A Wall/Window Air Conditioner

My toshiba split system will blow cold air for about 30min then it will blow what seems to be cool air but not air con cold air when it is quite hot outside. The timer light operation and filter light will flash. I have turned it on and off reset remote cleaned filters. When it's cooler outside it seems to work fine???


... Fujitsu 9RLS 9000 BTU Split System Air Conditioner

Hi guys, i have a portable air conditioner 9000btu 'ariagel ag90' window) that works great for the first 5 minutes, until gradually the unit makes more and more noise until it shudders quite violently , returns to its normal noise and blows out hot air for 5 minutes. This hot air seems enough to cancel out the cooling it does. then after a while it cools gradually I've read alot about this air con problem, but nothing regarding the gradual noise and shudder. The slide out filter at the back s


This is due to the compressor going into thermal overload, It can be cause by really dirty coils preventing air flow,A restriction in the cap tubes or orafice, Or an over or under charge in the system.The noise is due to the compressor building up to ... Air Conditioners

My air conditioner is blowing hot air instead of cool air.. what is wrong with it? a/c is blowing warm air. i checked the circuit breakers, all okay. check both fans, all okay. i pulled the filter, just a little dirty. i pulled the main panel off the unit and checked for a dirty coil, all okay. The unit is 2.5 years old and is suspended in the air in my garage. is there a clogged drain. should i get the bleach out? please help.


Check to see if you have power to the compressor. it my be a thermostate problem... ... Air Conditioners

Sometimes, our furnace will start blowing cold air when it should be blowing hot...I know it is normal that it blows hot air and then will blow cool air as it cools to shut down. This is not what I am talking about. I am talking about while the furnace is blowing hot air to heat, it will quit blowing the hot air and start blowing cold and it it like the air conditioner kicks in. It will then continue running cold air...I usually have to shut the furnance off and when it kicks back on it will


Do you have an automatic change over thermostat? this would switch it from heating to cooling. ... Air Conditioners

My lg 15000 er air conditioner is blowing hot air i could hear compressor starting for five minutez of cooling the n shuts off and hot air again i have cleen filtered and cleaned coils inside part


Hi,The unit is probably low on freon and so it is running too cold....this trips the freeze stat and shuts down the compressor till it warms up and you reset it by turning it off and then on again...The unit will need to be recharge or re ... LG BG8000ER Air Conditioner

I have a new Rheem heat pump. The cooling works fine but won't blow hot air in HEAT setting. I have reset the breakers for heat pump and air handler, changed filters and pulled batteries and reset the Braeburn 3000 thermostat. Still blows cold.... Any other suggestions?


If this is indeed a heat pump you rthermostat should also have a emergency heat setting does it work on that setting... a heat pump on heat wuns the outside unit and has a recersing valve that changes the refigerant flow ..is the outside runnigndurin ... Air Conditioners

LG Room Air Conditioner Model LSZ182VM-4 Turns on. I set a COOL temp. It displays that temp for about 10 seconds. Then C1 appears instead. Is blowing air....not hot, not cold. Filters just cleaned today. Thank you.


I would say that your return air sensor is faulty or not positioned correctly. Check sensor ... LG LS-L1210CL Mini Split Air Conditioner

My air conditioner isn't cooling, instead it is blowing out hot air. I changed the filter and it still doesn't seem to work. Any help is appreciated.


Check your condenser. if you cannot feel hot air out of it then the refrigerant is low. Check your fans. Clean your coils. Check your ... Air Conditioners

Window air conditioner keeps switching to fan mode. Which means on hot days it is blowing warm air. It sporadically switches to air conditioner mode. Room is hot because the cool air only blows for about 10 minutes. Help!


... Air Conditioners

I bought a haier electronic control air conditioner model HWR10XC6 on 6/30/08. I installed it. When I try to use the cool mode the air conditioner will only blow out cold air for about 5 - 10 minutes and then it just blows out regular air as if its on fan. I did what the manual said to do and it still continues to do this. I can't get it to blow out cold air for a longer period. Its getting really hot in here.


Hi,\015\012 It sounds as if the compressor (that provides the cooling) is cutting out due to either a faulty thermostat or is itself overheating.\015\012\015\012Obviously check the thermostat is able to move between it's minimum and ... Haier Air Conditioners

Air conditioner runs for a few hours and it works - it cools the house. Then it stops cooling - the fan still runs but it doesn't blow out cool air any more. It seems like it's overheating or something. It will blow out cool air if it has not been turned on in a while but once it's on too long it stops. I was told it could be the fan motor and the a/c guy changed the fan motor today but that didn't fix the problem. Now he says it might be the compressor or that I need a new system. I'm jus


The things I would check:\015\012Is the system properly charged with freon? Sytem may be overcharged.\015\012Is the compressor out on internal overload at the point of failure? If the overload isnt tripped and the compressor is having tro ... Air Conditioners

I have an air conditioner Appliance AAC 1100 A-PTC that wos working for two days and now its not cooling or heating:-( Both outer and inner parts of the machine seems to be running but it wont heat or cool the room. When i try to turn it on there is a red symbol that lights up on the display (defrosting) this light goes off every 5 minutes or so,then the machine starts to blow air (not heated or cooled) for aprox 20 seconds then the red light comes on again and this procedure starts over again.


... Air Conditioners

I have a Danby DPAC10030 air conditioner. It was working fine until yesterday, when we moved it to another room. Now it blows cold air for 5 minutes and then the air turns hot. The a/c motor continues to run even though the air is no longer blowing cold air. The current ambient temperature is 25 degrees C and I have the a/c set to cool to 17 degrees C. The timer has been turned off (0:00 on and 0:00 off). I noticed that the hoses (exhaust) feel quite hot. Not sure if that it normal within


Clean you filter and clean the area under the intake duck it will solve your problem ... Air Conditioners

3yr old goodman air conditioner is blowing cool air but not cooling the house. had a dirty filter and replaced filter, now it isn't cooling


Could be many problems start with making sure power is on to it may be tripped or blown fuse you most likely have dirty coils, the capacitor could be bad,if system froze up water could be in the drain pan kicking the float switch out those are most l ... Goodman CKL60AR60 Air Conditioner

Why does my air conditioner in my car blow out hot air? one minute, it'll cool just fine and the next minute, it blows out hot air.


Assuming you are not low on freon:\015\012I have seen this symptom caused by too much moisture in the system too, it freezes near the metering device which kills the refrigeration effect which makes it warm up, the ice melts and it starts worki ... Whirlwind FH-778 Air Conditioner

Air conditioner model 585CJ02450 doens't blow out cool air during the day at night blows cool air can I clean the filters and radiator


Was there any resolution? mine does the same it runs blows the fuse, but doesn't blow air out I would have liked to see what your resolution was. ... Air Conditioners

Wont work I have a Maytag central air thats about four years old. Once in a while it would stop blowing really cold air and would just blow mildly cool air. What I would do to fix this is flip the breaker off and then flip it back on again. When I did this the "high cool" light would come back on and everything would work just fine. This time that solution wont work. I have left it off for an hour at a time multiple times. I played with every switch and checked and cleaned every filter. We live


... Maytag M7Y15F2A Air Conditioner

I own a Zenith Air Conditioner, model ZW651OR. It is only a month old and it is not blowing cool air any more. I live in Guam (relatively a hot climate) the size of my room is 10' X 12' and the air conditioner runs pretty hard to cool room, what could be the problem


The problem could be dirty filters, dirty coil, refrigerant charge low,etc. Since it is only a month old I would try to return it if possible. ... Air Conditioners

My ac will blow cooled air, but then the ac unit will stop cooling and just blow hot air for a while. It'll switch back and forth instead of just blowing cool air. An ideas on what the problem i


... LG LXA1230ACL Air Conditioner

In hottest part of day it starts blowing hot air. We turn it off for 2-3 hours and comes back on anabnd blows cold air again. Technician unable to determine problem. Says we should buy all new unit. Current unit 10 years old. Coolent level ok. Coils clean. This is a 2 ton small unit cools our master suite only. Our other unit is 4 tons and cools rest of house with no problem.


For this case, either the AC needs cleaning or the compressor may be week.  You may want to check on the thermostat, it may send signal to the unit to stop cooling.  If it is a split type AC, you may want to check for leaks in the tubes tha ... Air Conditioners

My mother in law has a Ruud 10 Seer air conditioner. She's had it since 1998. The air conditioner runs fine but it will only cool the house now during early morning and evening hours. It no longer cools the house during the hot part of the day. Her power bill more than doubled this past month which is when the problem started. We changed the filter but that did not solve the problem. What else could it be?


I would shut off power to condensor and wash all the fins out as good as you can. I prefer to do this from the inside of the unit but that will require some disassembly so you can wash them from the outside if you want. If you have acess to the a-coi ... Ruud Matching Split Air Conditioner

I have a 2004 Chevy Tahoe with dual zone air conditioning plus rear air conditioner. My problem is on the 2 driver vents only it keeps going from cool air to hot air. After you drive for a while it is all hot air coming out of these 2 vents. All the other vents (passenger & rear vents) are blowing cold air.


If the truck has a dual zone temperature control in the center console then this is most likely your problem as alot of times when these go bad the think the driver side is too cold and turn the heat on to warm it up thus giving you warm air through ... Air Conditioners

My air conditioner blows very hot air out of the back and nice cool air out of the front. Is this normal?


... Windchaser PACR10 Portable Air Conditioner

My air conditioner is blowing hot air. The fan outside sounds like it is going to start but we get nothing. The air is blowing from the vents but it is not cool air.


Well that because the condenser is not turning on. you might just have burnt fuse should be right next to the unite or circuit breaker. ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific