Having problems with your Air Conditioners ?

My Maytag portable A/C will blow cold air for one cycle, then after about five minutes it just blows room temp air and never gets cold again. If I turn power off then back on it does the same thing over again. already drained the water and cleaned the filter.


Answers :

Cleaned the filter screen or the coils? There are two coils. The evaporator coil and the condensor. There is the "filter screen" in which you can clean which is located in the back top portion of the panel that is easily accessible. However to clean the coils you need to remove ALL the back screws from the back cover and remove the entire back panel. There you will see both coils. From your statement it sounds like there isn't sufficient airflow over your coils and the freon cannot release its cooling effect into the hot air thus it tends to ice up on the coils. You need to wash out all the lint dust from both coils. You can do this with with air conditioning coil cleaner or for starters use a stiff paint brush and vaccuum. Clean as much debris off as you can, then run the unit. It should last longer than your previous five minutes. If it doesn't work then your in trouble. There is a metering device called a TXV or expansion valve that may have failed causing the freon not to flow freely thoughout your system. However it is a rare occassion that it fails so it should be that the coils are dirty. GOOD LUCK

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Problem with Amcor PLM12000E Portable Air Conditioner- system stopped blowing cold air after power outage. Compressor turns on for 3 seconds and then turns off. Blowing out fanned air and room temp air out the back.


You more than likely have a blown relay or fuse ... Air Conditioners

Our 1992 brivis buffalo electronic pilot relighter does not ignite the furnace when you turn it on at the thermostat. Have tried turning it off at the power and back on again, makes a ticking noise for about 30sec then stops. Have taken the cover off to have a look, the pilot light is still lit and doesn't appear to be anything electrical. It will also intermitantly start blowing cold air and the only way to stop it is to turn it off at the power point outside. Could it be the ignition electr


... Air Conditioners

My Maytag portable A/C will blow cold air for one cycle, then after about five minutes it just blows room temp air and never gets cold again. If I turn power off then back on it does the same thing over again. already drained the water and cleaned the filter.


Cleaned the filter screen or the coils? There are two coils. The evaporator coil and the condensor. There is the "filter screen" in which you can clean which is located in the back top portion of the panel that is easily accessible. However to cle ... Maytag NMPEB08F2A Air Conditioner

The heat pump is not working properly. i think the problem is in the switch mechanism. when the heat is on and the thermostat is turned up it blows cold air. sometimes the compressor turns on and off. if you turn the other switch to the off position, then turn the thermostat up then turn it back to heat. it will blow hot air. if you then turn the thermostat down, wait till it turns off, then turn it back up, it will blow room temp air and sometimes the compressor will turn on.


Hi,\012The problem may be the switch, but it sounds more likely that the contactor in the outdoor unit is bad and is not making all of the time...then the compressor will not always run...\012To figure it out you will need to catch it at ... Air Conditioners

Sharp Air Conditioner AC09RLCSYS isnt cooling properly. Very moderate to low cold air from unit. At one point small bits of ice came out of indoor unit when on auto cool. Unit was switched off immediately and then turned back on after a few minutes with no additional problems, however still is not cooling properly. Unit is only eight months old. First used for cooling with no problems and great cold air, then for heating during winter. Now back to cooling and not getting the cold air like p


Unit may be freezing up if blowing ice crystals. Let thaw 24hrs try again. Make sure condensation drain line is cleaned out. ... Air Conditioners

I have a Heat Controller EKTH15-150J PTAC. Of lat,e toward the end of winter here in southern Missour,i the unit while in heat mode has been randomly blowing cold air. Often you can shut off the unit and let it sit for awhile and when you turn it back on it will come up heating again. A couple of years ago I replaced the control board that had been killed by a lightning induced power surge with a RSKP006 control board kit. It has run fine since, until the last few months. Sometimes I can pu


Your problem sounds more like a reversing valve issue.The reversing valve will tend to stick and not close completely causing cool air instead of warm.Check the low voltage wires to the control board(usually orange) and the 24 volt signal ... Comfort-Aire EKTH15-150J Air Conditioner

My Delonghi AC unit keeps turning off after a couple minutes. It completely loses all power. I will then unplug it and then plug it back in and it will restart. It is also not pumping out cold air like it used to. The AC will kick on for a bit but then it kicks off and just goes into fan mode


... Air Conditioners

GSH130241AC heat pump system will not work after my husband shut down main breaker to do something, after turning power back on nothing works, no heat, no air, no fan, nothing!!! Please help, I'm cold!


Please call an electrician to check power to a/c socket. ... Air Conditioners

Water tank full light keeps coming on an shuts the AC off after about 10 minutes on a Amcor A12000E Nanomax Portable Air Conditioner. I drained all the water out of it I could and it does turn back on after I turn it back on and will run for about 10 minutes. Then it beeps 6 or 7 times and the water full light comes back on and shuts it off. There is no more water coming out of it and there is a buzzing when it comes back on but it will blow cold air until it shuts off again. Please help!


Dod u get any help with your problem because i am having the same problem and ofcource the company is no longer around ... Amcor A12000E Nanomax Portable Air Conditioner

My triton t90si was airlocked so i was advised to open the casing. i unscrewed the cap into the water flow and pushed the small plastic ball back . the water flowed back in everything was fine. i put everything back in place. turned on the power and it worked perfect. but when i turned the power off there is now a constant flow of cold water from the shower head


... Air Conditioners

Our vulcan bonair ducted heating is blowing out cold air when i turn the control off it continues to blow out cold air only when i reset the main power does it turn off it flashes with reset i have reset but still not working


... Air Conditioners

My MSS15 aircondition stopped blowing cold air. Cleaned filters, turned machine off from main power, started it manually; still no cold air. Out side motor fan spins but sounds like compressor is not turning on. What can be the problem?


You will need to check the electrical side of the system....There are many thing that could be wrong. Contactor, start capacitors, thermostat, 24 volt side of circuit, compressor, Breaker tripped, bad breaker, Don't have 240 volts to unit, Manual r ... Air Conditioners

We have an American Standard Freedom 80 Gas Furnace.It is set on heat at 73 degrees and will only blow cold air throught the vents. We have tried turning off the theromstat and the breaker to the unit and then turning it back on. The little red light flashes fast until the unit kicks on then it flashes twice and it blows cold air into the house. Please help....we are freezing :(


... American Standard Air Conditioners

Changed the compacitor unit ran fine for half a day..then would not blow cold air..so i let it thaw overnight turned it back onit was fine..then after 5 hours..back to not blowing cold air..any suggestions?


If you let it thaw it sounds like your coil froze up\015\012a frozen coil is usually due to lack of air flow (a dirty air filter or bad blower motor) if both of these are ok then you probably are low on refrigerant\015\012i would suggest ... Goodman CKL24AR24 Air Conditioner

Hi, we have ducted Fujitsu air conditioner and it is displaying E:EE the error code is E .001 i have turn the power off on the until however as soon as I turn the power back on the error comes back? can you help please.


... Fujitsu Air Conditioners

I have a Sharp portable room air conditioner model CV-P10NC. The power plug RESET button and TEST button will not click in order to check out the power plug as the unit will not turn on. They did test O.K. at first but the unit would still not come on. Can the power plug back be taken off to check out the fuse inside - or since it is a type of built in circuit breaker maybe it does not have a fuse inside ? The instruction manual states that " This air conditioner uses a fused power plug". The un


The fused9G.F.C.I.) cord you speak of is probably the G.F.C.I. built onto these units by design, can you or someone you know get access inside the unit and :Hot-Wire" the units cord and,bypass the power cord ( Just To Test the Unit)and see if it stay ... Air Conditioners

I have split dual zone art cool air conditioners. Both worked this morning when I turned them on for the first time this season. I came home from work and nothing. I checked power sources and reset remotes. On both art cool screens is the temperature and "ch" flashing back and forth. The remote will turn it on for a split second and then turns off and goes back to flashing. Help! Thanks Bianca Zick


... LG Air Conditioners

COLMAN TSR I JUST BOUGHT A HONDA EU 3000 IS THAT I WAS TOLD SHOULD RUN MY AIR CONDITIONER WITCH IT DOES FINE UNTIL THE COMPRESSOR STARTS CYCLING. WHEN THE COMPRESSOR TRIES TO TURN BACK ON IT TRIPS THE OVERLOAD ALARM. I HOOKED IT TO THE HOUSE AND IT DOESN'T TRIP THE CIRCUIT BUT WHEN IT TRIES TO CYCLE THE FAN DIES ALMOST ALL THE WAY OUT FOR ABOUT 5 TO 10 SECONDS THEN THE FAN STARTS RUNNING OK AGAIN BUT NO COLD AIR FOR ABOUT 30 SECONDS THEN IT CLICKS FAN DOESNT CHANGE AND COLD AIR RESUMES. THAT LAS


3000 Watts is a little short on the power necessary for the compressor to restart. When it compressor starts it may draw 27 amps or more for a split second. 3000 / 120 = 25 amps. when the fan slows down it is telling you the voltage has dropped and i ... Coleman Mach 15 Air Conditioner

Wall A/C only SPORADICALLY blowing cold air. Turn it off and back on, you can feel it's cold, but only if you're 5 inches from it. After a couple of minutes, fan is only blowing warm air again. Vacuumed front of A/C, still doing the same thing. Filter is clean. It is over 100 degrees outside with very low humidity the last few days.(Los Angeles) ; since it's a wall a/c, of course 1/2 of it is outside in the heat. As I noted, if you put your hand right up against the front, you can feel cool air


If it blows be not with force like it used to it can be fan motor capacitor not boosting fan speed. but if speed is not the issuse. remove and clean both coils water hose ... Air Conditioners

At 30,000 miles my then 8 or 9 month old chevy 2500hd 4wd pickup truck air conditioning started blowing hot air on the driver side (the passenger side was still cold). I turned the truck off and back on and it began blowing normally for a few days and then it would do it again. A year or so later the heat on the driver side went out totally (passenger side worked properly). So now the driver side blows cold air constantly. A few months after that the blower quit working all together. Now at 185,


What year truck is this? This is actually a very very common problem on those chevy trucks. Most times it is the door blend actuator that has failed. and the default for this failure is driver side blowing hot. There are a million posts out there on ... Air Conditioners

I have a SPT model WA-9000E portable air conditioner What is going on when i turn it on to HIGH SPEED COOLING IT ONLY COOLS ON HIGH FOR ABOUT TEN MINUTES AND THEN CLICKS TO A WARM SETTING AND THE AIR IS WARM INSTEAD OF COLD STAYS LIKE THAT FOR SEVERAL HOURS THAN KICKS ON HIGH AGAIN AFTER TURNING IT OFF AND BACK ON AGAIN


... Sunpentown 9000 BTU Portable Air WA-9010E Air Conditioner

Our airconditioner has the code C6 on it. It has cut out and displayed that code. We were instructed to turn it off at the power board and turn it back on, which we did. It went back on again and tried to work but it wasn't really cooling down the air and then after 15 minutes it cut out again and displayed the same code. We don't know what the code means as there is nothing in the instruction booklet which indicates any codes at all.


I previously asked you, if the C6 appear on the unit or on the hand held remote. I contacted a friend of mine who is a service technician for the LG Split System units and he advised that it's an error code that can only be solved by a LG trained ser ... LG LA185HV Split System Air Conditioner

Our aircondituoning circuit on the power board shut down yesterday. Both air coditioners stopped. When we turned it back on the airconditioner in lounge room came on with left had light flashing continuosly but no cool air only fan working. I tried turning off the isolator switch outside for 15 seconds. The airconditioner came on with both lights working no flashing for approx 2mins and then resumed to only left light flasing again.Can you assist me with any further ideas? Thank you.Catherine za


Http://www.mitsubishipro.com/media/214656/msh-a18~24nd_servicemanual_ob427b[1]_5-18-07.pdf ... Mitsubishi Air Conditioners

Every time my heat pump turns on, the blue auxilliary light comes on, and it only blows icy air. I do not want to use that much power, so I turn it back down a few degrees. Now, it is 50 degrees in the house. Tonight it will be around 16 degrees outside. How can I get my heat pump to produce warm air?


A heat pump starts losing efficiency below 30F or so. The aux. heat helps the heat pump keep up with heat demand. The Aux heat can be electric heat strips or another type of heat. Check to make sure you have power to whatever type of aux heat you hav ... Amana PTH123B25AJ Heat Pump Air Conditioner

No heat My 7500 zoneline will not provide heat consistantly. I can unpplug the main power source to the control boards and plug it back in, ,and I will then get heat. If I turn down the thermostat (80 to 70), then turn it back up, I do not get heat again, only cool blower air. Is one of my control boards bad? Thanks.


It sounds like it could be the tstat itself. Unless you use a voltage meter to take some readings it's hard to determine if it is a board. The best thing for you to do is remove the tstat from the system and manually operate it with a jumper wire t ... GE Air Conditioners