Having problems with your Air Conditioners ?

Hi. We've been running our LG BP6000ER window unit air conditioner for four seasons. We've made seasonal efforts to clean the interior with a hose, but this year we're noticing a strong mold/mildew smell eminating from the unit particularly when the compressor cycles off. Short of taking the unit to a professional to be cleaned is there anything we can do to either (1.) clean it more thoroughly-- perhaps by removing certain parts or (2.) to kill the mold with a spray of some kind. We'd b


Answers :

Take it outside .get the hose .buy some coil cleaner hardware store .clean the coils good.. both of them .try to be carfull of the controls not to get them to wet ..cover them if you want ..after cleaning coils tilt unit to remove most of the water let it dry, use a fan its quicker should do the trick .it will work like new and smell better

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Hi. We've been running our LG BP6000ER window unit air conditioner for four seasons. We've made seasonal efforts to clean the interior with a hose, but this year we're noticing a strong mold/mildew smell eminating from the unit particularly when the compressor cycles off. Short of taking the unit to a professional to be cleaned is there anything we can do to either (1.) clean it more thoroughly-- perhaps by removing certain parts or (2.) to kill the mold with a spray of some kind. We'd b


Take it outside .get the hose .buy some coil cleaner hardware store .clean the coils good.. both of them .try to be carfull of the controls not to get them to wet ..cover them if you want ..after cleaning coils tilt unit to remove most of the water l ... LG BP6000ER Air Conditioner

Power button I have an LG 36,000 btu unit. While cleaning the filters something odd happened. The temperature display is reading 4 and nothing seems to be working. The unit is on, but the remote is not changing anything. The remote display changes, but the unit doesn't respond. Also, I tried to switch it off manually, but the on/off button is not working either. It's like it's frozen. And the room temperature is going up. Help.


Try to un hook the power by turning the breaker off for 30 minutes to reset the electronics. see if it would work after that.tnx 4 using fixya,drcool ... Air Conditioners

Condensation water is not draining properly on Goldstar AC window unit and backing up and dripping on the wood frame and floor below the unit. Is something blocked it just started happening. I am going to clean the little pipe that water drips from outside but it involves climbing a latter. Also I am going to clean the condenser coils...is there another reason or anything else I am missing and do you clean the condenser coils with little wire brushes? It occurs after the unit has been runnin


Yes,remove the ac unit from the window,and clean it out with a water hose out side,remove all debris from inside the unit,and tilt water out of unit.Make sure there is nothing in the way of the drain,and when the unit is put back in the window,make s ... Goldstar KG6000R Window Air Conditioner

We have mitsubitshi mr slim air conditioners one of the units has what appears to be mold inside the unit. one repair man wnat s to take the unitis off and clean them out anotjer says he would spray chemicals into them but not take off the unit one says this condition is typical- the other syas it is not I don't know what is best


It is not always normal but it does happen and there is a chemical that can be spryed right into the coil and pan that is very affective not necessary to pull off the unit ... Air Conditioners

I have a Goodman gas furnace (model GMP 108-3). It recently stopped working. It is an hsi unit. The HSI appears to be working - I don't see any cracks or anything. When I flip the switch at the unit, the fan kicks on, the HSI gets hot and then the top burner lights. Problem is that it doesn't stay lit and it doesn't travel to the burners below it. I took out the flame sensor and cleaned it with very fine sand paper, but that didn't seem to do anything. Any ideas?


On your flame travel tube sometimes something gets in that and blocks the path. Now this is what I found one time when same problem happened. I took it apart and found a dead **** roach in the path. Took the bug out and it worked perfe ... Air Conditioners

I can hear the thermostat click when I move it above and below room temp, but no other sound or anything from the unit. No buzzing or fan or anything. The unit is a 2006, has been sitting never used. Don't think the air ever worked from new, it is very clean when I look up in there


SHUT OF BREAKER AND CHECK ALL WIRES GOING TO THIS THERMOSTAT ,MAIN POWER WIRE MY BE BURNT OFF TSTAT CONTROL ... Dometic Rooftop RV Air Conditioner

Kenmore 580.75151500 A/C unit smells... We've had this window unit in place for 2 years. We've cleaned the front filter and coil, but we're still getting different, peculiar smells from the A/C. Sometimes it's vingar, sometimes urine-like, sometimes moldy smelling. Is there some place else that we can clean it? I've downloaded the user manual, but it's really just a parts manual - doesn't say anything about maintenance or upkeep. Thanks


Hi!!\015\012\015\012As you know, the evaporator unit (the one that the filter covers) gets a lot of condensation which is drained thru the back (outside) of the unit. That's why the unit is installed a bit tilted to the back.\015\0 ... Kenmore Air Conditioners

My Rheem RCBA3765AS17 Air conditioning unit is leaking water again from the left corner of the unit under the drain pan. I just had this fixed a month ago and cleaned the reusable filter. It is now covered with slimey black stuff! How do I get that filter clean again? I ran water forcefully through it, but that's not good enough. Is there anything else I can do myself before calling a professional again?


... Air Conditioners

I have a ruud ac unit model # rcba 3765g. I removed the filter and look up at the coils and noticed that the dirt was caked on the them. What is the best way to clean them. It looks like it will take some kind of a solution to get it off. The unit is about five years old and the coils have never been cleaned. Thanks, Paul


Welcome to Fixya !Here\012 are some steps that you may follow. Take come caustic soda ,(put a table spoon in one glass water) that will be in powder form (caustic soda) , if you do not have this caustic soda , the ... Air Conditioners

I have two Dometics on my rv. A 530515 and a 530516. They are working fine but 8 years old. I take the covers of yearly and clean the coils. Should I or could I remove the covers to the cooling coils and clean them. I keep the interior return vent filters clean but don't know if the cooling coils are really clean. My unit is full time since the last 3 years.


... Dometic Rooftop RV Air Conditioner

AC Out. Two year old house. Goodman A/C, two units one for upstairs. Cleaned coils of both outside unit, replaced filters, re-set breakers. Upstairs is cooling. Downstairs unit is running outside, not circulating air inside (inside temp 87). Vents inside are cool to touch, no air. Outside unit fan is pulling, but air exhaust is cool. Compressor ? Should air be circulating even if compressor not functioning. Is there anything in attic exchange that would affect downstairs circulation. Thanks.


Assuming that the 2 systems are isolated, that there isn't any cross over between the systems...It is normal for an air conditioner system, from window unit to central, to be able to circulate the air, even if not cooling. This is known ... Air Conditioners

Is it ok to replace outside unit of central air and heat and not the inside air handler ? The upstairs A/C( over 10 yrs old) is not keeping up with South Texas heat. The temp upstairs climbs to 84-86 degrees by the afternoon and takes 4 or more hours after dark to cool back down. I have cleaned the entire unit outside- no help. I have replaced the downstairs unit 2 yrs. ago and it works fine. I don't want to replace the upstairs air handler if I don't have to---much more cost.


I'm assuming you have had a competent Air Conditioning contractor look your unit over.if you trust your A/C contractor, why don't you work with them towards an answer? I would get an air flow and sizing analysis, a full equipment service/performance ... Air Conditioners

A/C Model: FAC107P1A My unit is not putting out cold air. The temp wire is not touching the coils. I've cleaned the filter, and behind it. What do you think the problem is? What needs to be done to fix the problem? Could it need Freon? What type of Freon does it take? I have a certified person to put it in, but I have to get the Freon myself. Is it a sealed unit? Will it be obvious to him, where to put in the Freon? He said that he's not sure, but hasn't looked at my unit yet. I have to g


Hello, if the filter, evap, coil, condenser coil are clean then most likely the unit if low on freon. most window units take either r 134a or r -22, it will say on the data plate on the unit. To charge freon into the unit a piercing valve will need t ... Frigidaire FAC107P1A Wall/Window Air Conditioner

I have an 8 year old 2 1/2 ton carrier compressor unit. I have already replaced the running coil and contactor. I now want to clean the coils and fan blades on the motor. I have never had reason to remove the top grill. I looks as though the fan motor is attached, and I don?t want to do anything stupid ?if I can help it? or damage or disconnect any of the wires. what is the proper way for me to access the inside of the unit so as to be able to spray off any debris that may be on the coils. So fa


Hey Bernie, it is possible to remove the 4 screws on the grill that the motor is mounted to (not the bolts holding the motor to the grill)and pull up and twist so its upside down and have someone else hold it as to not put to much stress on the wires ... Carrier 38CKC042 Air Conditioner

Shut unit down for cleaning, outside unit will not start now, I have line voltage at the contactor but the contactor will not engage.one wire from the thermostat runs to a little black box next to the contactor (white) the red one runs to a device down by the dryer on one side and back to the black box on the other side. Both of these wires come out of the box and attach to either side of the contactor.Could this piece be the problem or is it the black box.If I manually engage the contactor the


You are talking about the low voltage transformer ... Ruud Handle Air Conditioner

My apartment has a Ruud UAND-024-JAZ installed since 2006. It takes approximately 7 hours for it to reach the temperature the thermostat is set to (77) My landlord had a service personcome out and flush the coils 2 months ago, the unit was checked and the vents have been cleaned. He said the unit was fine. My electric bill is running about $100 a month..which I think is high. I wonder if there is something else that was overlooked.. Regards, Linda


Hi,\012With out knowing where exactly you are and how many sq. ft. you are cooling it is impossible to tell if you are working properly or not...\012The best way to tell would be for you to check the return air temperature and the supply ... Ruud UBHC Air Conditioner

Ac unit #317826 worked perfectly all summer last year. drained, cleaned and stored in an inside closet and took it out and now it won't turn on at all in any outlet or with resetting breaker on plug. Is there some sort of reset button on the unit? Anything else I can try?


I wonder if the water tray is in correct position. This manual is not a Danby but is similar. Gives checklist: 10,000 BTU ... Danby Air Conditioners

I HAVE A GOODMAN 2 AND HALF TON UNIT THAT IS NOT REALLY BLOWING THAT COOL. i CLEANED THE COIL AND CHECKED TO MAKE SURE THE DRIP PAN WASN'T CLOGGED. THE UNIT IS NOT FREEZING UP EITHER.


In order to freeze, some refrigerant must be present. The outdoor units compressor overhats and will cut out, the fan stays on, if poor refigernat charge is the problem. This overload will not reset for 1-3 hours, just enough time to defrost and refa ... Goodman Air Conditioners

No heat I have an Amana heating and a/c unit model # pth153b50ae. It was blowing heat all winter then just stopped. It now blows cold air and is either bringing in cold air from outside or is blowing a/c. It does not change no matter where the control knobs are set. I checked the fuse and actually changed it but no difference. The only way I can turn it off is either unplug it or take the cover off and switch of the little micro switch. I'm thinking the board is gone. Any help would be appreciat


Check to see if unit has a contactor,they arc and weld together,keeping your unit on ... Amana PTH153B50AE Air Conditioner

My fan stopped working, but i hear the refrigeration unit working. is there something i can do to fix this? i cleaned out the filter, that didnt do anything to the issue. when i have it set to just fan mode, nothing works. but when i set it to high AC i can hear the ac unit working but no fan movment, so im assuming its the fan that is the issue.


Yes , you may have to change your fan and it should work . seems your fan went up on your a/c .. ... Haier HWC05XCB Air Conditioner

My house is 1308sq foot living. My outside unit is about 4yrs old, the air handler is about 3yrs old. It cools decent but when I have family over (appx 10 people or more) the a/c keeps running and never cools down. Is there anything I should be doing like cleaning the coils every so often in the handler? Or clean out the lines where the water drains? I change the filter usually monthly..


Yes, change the filter every month or so, more if you have pets. Spend the extra dollars and get filters you cannot see through! If you can see through it it is worthless to start with. You should see if it gets dirty and needs changing. You may have ... Goodman CLQ36AR49 Air Conditioner

Hi, my AC unit is runs but lately it's been tripping the breaker I'm wondering if I need to clean out some kind of filter to help it run better. I've owned the RV for a year and a half and have never done anything with the AC Units.


Yes, remove the cover and clean the condenser fins with a water hose ... Dometic Rooftop RV Air Conditioner

Cleaning The vent part of my Friedrich SS10J10A window AC unit (that is, the upper part, with the movable louvers) is crusted with mildew. I would like to take it off and clean it. I unscrewed the two screws holding the piece in place but something is holding the piece in the center. I don't want to tug too hard, lest I break the plastic. Suggestions? Thank you!


My husband figured out that the grilles themselves click out--not the whole assembly. Now he is going to have to figure out how to click it back in! ... Friedrich QuietMaster Electric SS10J10AR Air Conditioner

A/c hoping can get help few different things all revolving around the blasted a/c first whenever the a/c kicks in every light in the house dims for the initial boot up then good doesn't kick anything off just common sense says when it dims that much to everything else hoping nothings wrong ain't the best thing secondly looking at the a coils on the a/c unit model # c30a 054u on what I believe in an Intertherm unit also looking to clean the thing in hopes of helping to reduce the bill the a/c un


The dimming of your lights at start up tell me two things, One is that the starting Amps may be a little high and drawing too much amperage. Have this checked by using an Amp meter. Secondly, look at your circuit breaker box. Does the Amp total on th ... Air Conditioners

Clean unit I vacuumed the front under the filter piece, the front, do you mean to take the unit out of the outer part, I'm not sure I can do that. How and or where do you get preon? Is it really expensive, and how did it get empty? Does it leak out somehow?


Could be leak out or its probably empty and need to be fill it again... its not really expensive, and doing that you may need a experience aircon/refrigeration service tech. ... Maytag M7Y15F2A Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific