I installed a Proplumber pressure switch 30/50. I also installed a new gauge. I have had difficulty adjusting the switch so it will shut off. I have 31 psi in my tank and I know I have to adjust it to 2 psi over the tank but which way do you turn the adjustment. It only has one instead of two adjustments like my old switch. The pump kicks on like crazy and I am losing my mind and sleep with that thing kicking on every minute. HELP!!


Answers :

Not sure if this will help, but I tried to research this a bit and one fellow who has the same unit said to adjust the screw downward to increase the pressure. If it's normal threading, that would mean to adjust it clockwise, from my understanding. I think increasing the adjustment might help you out...
\015\012Anyway, good luck and hope this lets you sleep better!

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I installed a Proplumber pressure switch 30/50. I also installed a new gauge. I have had difficulty adjusting the switch so it will shut off. I have 31 psi in my tank and I know I have to adjust it to 2 psi over the tank but which way do you turn the adjustment. It only has one instead of two adjustments like my old switch. The pump kicks on like crazy and I am losing my mind and sleep with that thing kicking on every minute. HELP!!


Not sure if this will help, but I tried to research this a bit and one fellow who has the same unit said to adjust the screw downward to increase the pressure. If it's normal threading, that would mean to adjust it clockwise, from my understanding ... Air Conditioners

I have two (2) singel switches next to each other that turn on the lights in the garage and the other the lights outside. I bought two (2) 1595-SWTTRWCC4's and I would like to know how to install them. Each one has two black wires coming out of the Pass & Seymour. Out of the wall I see one red and one black wire going to one existing switch, and two additional black wires going to the other switch. Ground is no problem. How do I wire the both ? Thanks Guido


I need a little more info, could you post a picture of the switch you are trying to install? ... Air Conditioners

I installed a ceiling fan in two bedrooms and when i removed the old light fixture there was a red wire capped off. Should that red wire be connected with the black and blue wiring to have a switch to turn on/off the fan only. I have two switches which one never worked when i had the old fixture up and it did not control any outlets.


Here is a Link to ... Air Conditioners

Installed two new 3312020 controlers wired with inst will only pick up zone1 all dip switches off on front unit exept furnice zone 2 on back unit old controlers only had one inside air temp i ordered two new ones still nothing on back unitwhy will it not inl back unit


... Dometic 3312020.000 Comfort Control Center II CCC2 Multi-Zone Kit

GOODMAN AIR HANDLER MODEL CA*F4961*6A*+MBE2000**-1 HAS HEAVY CONDENSATION IN THE TOP OF THE UNIT WHERE THE ELECTRICAL /CIRCUIT BOARD IS LOCATED.THE UNIT IS LESS THAN ONE WEEK OLD. THE COMPANY THAT INSTALLED IT HAS CHANGED THE DIP SWITCH SETTINGS AND TODAY PUT IN LARGER COLD AIR RETURN DUCTS.STILL IS THE SAME.ALSO THE COILS UNDERNEATH HAVE HEAVY CONDENSATION ON THE BOTTOM OF THEM.WHY CANT THEY FIX THIS ONE WEEK OLD UNIT.THE OUTSIDE MODEL# IS SSZ140601A*THE HOUSE IS 2480 SQ FT. THE OUTSIDE UNIT IS


This is not even a repair issue.If it is hot out and it's on quite a bit,there will be much condensation.However,condensation on a circuit board is never good.Since it is only 1 week old and you can see this serious of a potential problem,especially ... Goodman Air Conditioners

I recently purchased a used ac for my rv. it has two and one had gone out. the air coming out of the new one only gets down to 60 degrees while the air out of my old one is 50 degrees. they are both the same brand. does this mean the new one has something wrong with it or is it normal for some ac's to blow colder air i dont know is is should take it back or if it is working like it is suppose to help


No it means you 50 degree one is working better than perfect. Clean the one that is only getting down to 60 degrees but remember if a unit is dropping the air temp by 20 degrees its working fine. You ck this by cking the air at the intake where the f ... Dometic Rooftop RV Air Conditioner

I have an electric blanket which is two years old. I switched it on today for the first time today to test it, and discovered that the timer switch on one side works perfectly, but the other switch keeps showing up as 'timer off'. How can I remedy this please.


... Sunbeam Air Conditioners

I have been given a old Martin Industries Edison 25 dehumidifier, but have no manual. Question 1: The collection tank has a short plastic tube connected at bottom side of tank via threaded connection. Looks like water would drain out of the tank so how do I stop that? Want it to collect and shut off when full. Question 2: There's no back cover - metal coiling is exposed.Should it have a back cover? Should I improvise one and if so with what sort of material?


WOW, you do have an antique. Martin hasn't made those since back in the 80's. Martin Industries has been out of business now, for 5+ years. Since it's missing some parts and there's no Owners Manual available, I'd recommend not using it, because of t ... Air Conditioners

I have a York 90% furnace that's about 8 years old. Appeared to have a bad pressure switch but I just installed a new one and still get 3 amber lights. The burner box and combustion hoses are clear. When I disconnect the tube to the burner box from the pressure switch it starts up/ignites fine. But when it is attached to the switch it will not start.


Hi,A few thoughts....does the switch have both NO and NC contacts and you got the wires on the wrong ones???Is it possible that you have the hoses switched???Is the opening into the burner box plugged....is **** running ... Air Conditioners

I've installed a Hunter 44550 thermostat. When I programmed it to cool and turned it on, the heat came on. I then switched the two wires I had running between the RH and RC switch and now nothing comes on: not the heat, not the fan, not cold. I know I just have the wires mixed up, but am not sure which ones to switch. I have a 5 wire setup.


Do you remember how the wires were hooked up before replacing the thermostat?\015\012Do you have make and model information for both your air handler and your outdoor unit?\015\012Is this a heat pump or straight air conditioning?\01 ... Air Conditioners

I BOUGHT TWO DIFFERENT PROGRAMMABLE THERMOSTATS TO INSTALL IN MY HEAT PUMP SYSTEM, I FOLLOWED THE DIRECTIONS TO A T BUT WHEN I SET IT TO COOL THE UNIT REVERSES AND PRODUCES HEAT WITH BOTH THERMOSTATS. MY EXISTING THERMOSTAT HAS TWO MERCURY BULBS AND WORKS FINE, i HAD TO PUT THE OLD ONE BACK IN. WHAT CAN THE PROBLEM BE?


Heat pumps normally have what is called a jumper wire between you R and RC, RC run cooling. You may not have the jumper installed correctly. Instead of RC you may be using RH run heat ... Air Conditioners

Honeywell F50F 1065 electronic air cleaner. Replaced power supplies in two units, installation went well. One unit works as it should. Second unit turns on for just under a minute and then goes off. After two or three minutes unit can be turned on again but only for a minute or so and the problem continues. All wiring and switches seem to check out fine. Any thoughts or pointers you can give me?


... Honeywell Air Conditioners

One year old condenser unit salt corrosion. Inside temperature reading at vent nearest evaporator was 56 deg. At 45 psi applied salt removal solution to condenser unit removing the salt. Next day took Temperature reading and lowered inside temp. at vent to 51 deg. Can you tell me how many kilowatts I saved per deg for 1 month. Or can you tell me if a new installed unit inside temp at evaperator is 50 deg and temp inside increases one deg thru 10 deg how many more kilowatts will be used. Efficen


I was able to find a table with complete conversions for your convenience. Its at the lower part of the file specifically on pages 16-17. You may want to click here ... Weather King Air Conditioners

I have to replace the start/run capacitor (97F9971 - Duel Capacitor/ 50, 7.5 370 VAC). I have marked the terminals before removing and purchased the new capacitor. The new capacitor has minor difference with the old one. The hermatic has 3 terminals, The Fan has two terminals The Compressor (C) has 4 terminals. Now in the old unit, two wires were connected to two opposite terminals on C, one in Herm and one in Fan. My question is: How will I know which terminal to connect in the new one


All the terminals are connected together so it won't matter which terminal you use, just as long as you have the Herm, Com, and Fan wires correct. Hope this helps! ... Air Conditioners

Replacement Repairs My air conditioning unit is slightly less than three years old. It quit working so I called the business that installed it. He found that there was a blockage in the necking device on the evaporator coil increasing liquid pressure 40 PSI. I feel that, in as much as this is within a sealed unit, it is a manufacturing problem, not one due to my environment or my doing. It is a very expensive part to replace and I feel that there is some responsibility on your part for this prob


Most units have a 5 yr parts warranty but you would be resposable for labor. ... Weather King Air Conditioners

Air conditioners i have a frigidaire 13 SEER 3.0 ton unit that needs to be upgraded to 14 SEER. are there any kits available that can be installed on the unit that will increase the SEER value by one point? i am trying to qualify for an award, and it must be 14 SEER. the units i have are only two years old, so i do not want to replace them.


No kits, you will have to upgrade. ... Air Conditioners

Amana 90% model #GUCAO45AX30 SER# 0109143635 UNIT MAIN BURNERS LIGHT UP THEN SHUT DOWN IN A FEW SECONDS. DRAIN LINES ARE CLEAR, VENT PIPE CLEAR OF CONDENSATION. I BYPASSED T-STAT JUMPERED R-W NO HELP, INSTALLED NEW FLAME SENSOR STILL SHUTTING DOWN. UNIT HAS TWO PRESSURE SWITCHS OFF INDUCED DRAFT MOTOR, HOSES GOOD CONDITION AND TIGHT. I HAVE HAD PROBLEM WITH WATER IN 2 INCH ABS VENT PIPE, NOT SLOPING BACK TO UNIT, THIS ONE SEEMS TO BE CLEAR. SHOULD I CUT PIPE AT FURNACE AND TRY TO START ?.. MAYBE


Check to see if the flame rod tip is in the flame(like the hot junction on a thermocouple). the pressure switches are a normally closed switch and a blocked flue could cause them to open. the circuit board should run through the safety switches and c ... Amana PTC074B25AE Electric Heat Air Conditioner

Hello, I have a Amana Air Command 80 model #GHI90A50, 22 years old. This furnace is on its third ingnition module (last one two yeras ago). The symptom I am trying to diagnose has been ongioing since this latest ignition module was installed. The furnace is short cycling, meaning it runs often once every 8minutes but for less than 3 minutes at a time. The sequence is as follows: Cycle start (small blower turns on), followed by the ignition module illuminating (yellow) for 3 seconds then turns g


If your furnace lights and the gas stays on for 8 to 10 seconds, then shuts \012right back off, then you need to clean your flame sensor with light sand paper \012or steel wool. You might need a new flame sensor, but most of the time th ... Air Conditioners

Furnace starting Lennox furnace model G6OUHV(X) series. Furnace would not start heating cycle unless I ran thermostrat temmp. setting up and down. Most times it would than start heat cycle. If not I would shut main power switch on furnace, wait a few seconds and then the furnace would start the heating cycle. I suspected the thermostat so beofre purchasing a new one I installed the old from my privious Lexxon. It now seems worse than ever. I either move the set points up and down (sometimes it w


Hint number 1, get HVAC license. One mistake or misunderstanding and you could blow your house up. ... Air Conditioners

Sharp Air Conditioner AC09RLCSYS isnt cooling properly. Very moderate to low cold air from unit. At one point small bits of ice came out of indoor unit when on auto cool. Unit was switched off immediately and then turned back on after a few minutes with no additional problems, however still is not cooling properly. Unit is only eight months old. First used for cooling with no problems and great cold air, then for heating during winter. Now back to cooling and not getting the cold air like p


Unit may be freezing up if blowing ice crystals. Let thaw 24hrs try again. Make sure condensation drain line is cleaned out. ... Air Conditioners

I have an AlphaCB24/28 wall mounted boiler, approx. 8 years old. Whilst running my central heating and/or hot water, the boiler would cut out and a continuous red light would replace the flashing orange light! After resetting the boiler using the reset switch the boiler would function O.K. for between 15 minutes and two hours, when it would cut out again! I called in a local reputable plumber/heating engineer and he replaced the overheat stat. and repressurised the expansion tank and cleaned the


Its the air pressure switch ... Air Conditioners

How do I remove the squirrel cage to clean it in an old 20+ year Trane Weathertron? It has deposits on the blades and looks like a major job to get to it as it appears to be enclosed in a sheet metal housing that in turn is screwed into the main housing. Also, where is the model # listed on these units? A crumbling schematic found inside says it's a BWC030C100A2 but the repair tech who worked on it before noted it as a "28JE1N". He said I needed two run caps, one a 12.5uf that measures a


You won't like this,BUT, if it were mine\015\012and 20 years old,I would replace the entire unit.\015\012\015\012If you need caps, the motor will be going,\015\012before you get the squirrel out to clean ... Air Conditioners

Replacing a o smith fan fse1026sv1 into York ac unit model H2RA036s06A. Old fan had two hot legs, one from capacitor, and grnd. New fan has two brown, old fan one, that go to capacitor. Tried wiring browns together put fan shut down after about 5 minutes. And it was hot all around the top above the coil. Any suggestions?


... Air Conditioners

After removing my old two globe bathroom light I found one red wire, 2 black wires and two white wires, the two black were capped off. How do I hook up a three bar light that has one black and one white wire?


Hello. Since the two black wires were capped off, leave them that way. Now hook the red wire to the black in the light bar and the two whites to the white in the light bar.\015\012\015\012That's it. Regards, Joe\015\012\015\012ps kind ... Air Conditioners

We have a honeywell ct85 ( the round one) and we accidently broke it.. i need to buy a new one and install it but i dont know how.. i tried to take it off the wall and saw 4 wires..two red ones, one brown, and one green.. need help and explanationof the the installation process for this? does it take a long time and is it hard to do?


Do not worry about the colors, rather the terminal markings.Usually R_Rh will get Red G will get green the may used brown on Y ... Honeywell Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1069 seconds