The fan on the Ruud furnice unit runs all the time but the Ruud ac unit is not kicking on . I know nothing about any of this but would like some Ideas what I might check. I went outside and could not find any kind of breaker on the outside unit. I do have a breaker inside and I turned it off and waited then turned it back on ..no change...


Answers :

Some Ruuds have a red rubber cap reset button on the bottom of the unit or inside. Usually the fan quits and trips the switch. Or look at the metal run cap with 3 leads on it, if it looks bulged(concave on top) and not flat and sunk in, replace that and ur good to go. Let me know. Please pull the power disconnect if you attack the cap, and write down what leads come off which terminals. [email protected]

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

The fan on the Ruud furnice unit runs all the time but the Ruud ac unit is not kicking on . I know nothing about any of this but would like some Ideas what I might check. I went outside and could not find any kind of breaker on the outside unit. I do have a breaker inside and I turned it off and waited then turned it back on ..no change...


Some Ruuds have a red rubber cap reset button on the bottom of the unit or inside. Usually the fan quits and trips the switch. Or look at the metal run cap with 3 leads on it, if it looks bulged(concave on top) and not flat and sunk in, replace tha ... Ruud Central System Air Conditioner

I have a RUUD 13pja42a01 heat pump. The main breaker in the house was turned off about a week ago. We have not tried to turn on the AC until today and the outside unit will not come on. The main breaker in the house is on as well as the heat pump breaker. I was looking for a reset button but cannot find one. Also in the box outside connected to the unit it does not appear that there is a breaker in there.


Check the small wires going outside to the contactor for 24 volts. If you have 24 volts then mayb ... Air Conditioners

For ruud achiever 10 ac unit uaka-030jaz. Unit was working fine saturday...sunday we noticed air was not cold anymore. I have checked all my breakers, put a new battery in the thermostat, cleaned the filter on the furnace unit, and opened the exterior unit to see it the relay was burned( appears ok as long i understand which part is the relay.). When we turn on the ac the furnace unit in the attic will come on and blow air..however it never gets cold and nothing in the outside unit appears to co


Hi, the problem is in the outdoor unit if the indoor unit comes on and is blowing air. At the unit, you will have a disconnect box, 220 volts. Inside there will be 2- fuses. If you can't see them its because they are behind the plastic cover. You may ... Air Conditioners

I have a 1993 Model SRHF48U01A (The 0 might be a O (zero) When the thermostat calls for cooling, the inside unit (fan) starts up and continues to run but the outside unit wants to start (it comes on for a second and then trips the breaker that is located behind the outside unit. I can turn the breakers off that are inside the house and let them stay off for a short time and then reset the outside breaker and then turn the inside breakers on and the unit starts and continues to run until the te


Well the trouble is surely at the compressor side. Dont know what kind of repair man you invited. He should have atleast diagnosed the problem. Following can be the causes\015\012\015\0121. Capacitor is slightly faulty (As you said). If t ... Amana Air Conditioners

My breaker trips when the outside unit tries to turn on. The inside furnace runs. I cut the inside unit off and the breaker doesn't trip. I manually turn on the outside unit by depressing the cont


Hello, there is a short to ground somewhere, check all the wiring from the inside un it to the outside unit and make sure nothing is touching metal. ... Goodman Air Conditioners

My fan and heater work fine, but today I turned on my air conditioner for the first time this year. It did not feel like it was getting cooler so I went outside and noticed that my outside unit was not working. I went and checked the breaker and noticed it was tripped, so I turned it off and turned it back on (the breaker). Then all orf the power went off to my house. I then reset my whole breaker box and I heard what sounded like my outside unit explode. I ren over to it and it sounded lik


You had a refrigerant release. Probably two lines rubbing together in the outside unit. I have repaired several of these with this problem. It involves repairing the lines by silver solderingthen pulling a vacuum/ purging with nitrogen an ... Carrier 36KCARMS Air Conditioner

We have a new house and it came with central air. I have turned on the air and turned on the circuits and noticed that the outside fan on the outdoor unit was spinning round (good) now, I checked and the fan is not turning. Turned the unit on and off, still no turning and checkecd the circuit breakers...Any help please. Model is Aire_Flo Outdoor unit AFAIR12B30-A P I hear a low hum to the unit outside. I see trouble here.


First check to be sure the circuit breaker for the outside unit is not tripped. Turn the two pole breaker all the way off all the way off and then back on. If the outside unit still does not run you may have fuses in a disconnect box by the outside ... Air Conditioners

My unit is 4 years old. I always turn it off when I leave for work in the am and turn it back on when I get home in the pm. Last night I turned it on at 7:30pm. When I went to the front of the house about 45 minutes later, I noticed the unit outside was trying to turn on but would immediately turn off. I checked the breakers in the garage, turned them off and back on but still had the same problem. The fan inside the house is running but unit outside will not kick on. I looked for a magic


It could be a few things.. It could be the capacitor - which the most economical to replace first..\015\012\015\012If you are not really very mechanically inclined - get a trained pro to come out.. It is very dag ... Air Conditioners

My 38CKCK24330 Unit stopped running, it will try and turn on every 10 or 15 mins you can here it outside buzz, I looked outside at the unit and the fan is not running. The system has power, the breaker switches are working, the furnace turns on fromt he attic. What do I need to trouble shoot, someone told me to check the switch on the unit by pressing it in to see if the fan will turn on once the button is pressed in. I did this but the fan did not turn on. Any help would be appreciated it, I


Hi angelagaddy,With the fan not running and you are hearing a buzzing noise outside this is more likely that the fan motor needs to be replaced or the capacitor ... Air Conditioners

I have a Ruud Achiever 10 and it only puts out cold air when I turn on the heat. I've flipped the breakers both in and outside at the unit...help! We're freezing!!


Is this a heat pump? If it is the switch you thermostat to Aux. or emergency heatt. ... Ruud Matching Split Air Conditioner

A/C outside unit will not run. Inside works, breakers are on and did not trip. No noise coming from outside unit, except for low buz when 1st turned on. After 10 seconds, nothing. Goodman # CPLJ36 - 1B. No idea how old. Have tried turning breaker switches off and on. Has been 24 hours, just tried again . . . nothing happens but that short buzzing sound, a low beep, and then silence.


Sounds like your contactor/relay on compressor defective, by the way it sounds the buzz is from the magnetic coil on the contactor but its not pulling the contacts in to start the compressor ... Air Conditioners

Ruud heat pump outside unit trips circuit breaker


Check your wiring between the contactor and compressor for a short to ground, or check the compressor windings for short to ground. \015\012With the Tstat off, the contactor should be open so the only way for the compressor to be trying to do a ... Ruud Central System Air Conditioner

The outside unit on our Ruud heat pump won't turn on. The inside fan blows but the unit outside sits idle - no fan turning, nothing. It was cooling earlier today, but when I came home from shopping, the house was warm, the inside fan was blowing, but the outside unit is silent, not running.


First look for red button neer the copper line set if has one push it second inspect thermostat wires for weed eater damage check disconnect for fuses check breaker at main panel pull disconect and remove cover check stat wire connections look at the ... Ruud UPMC036 Air Conditioner

I have a Goodman CPLE42-1 split system. I had a power outage and my first floor unit would not cool anymore. The air handler/blower in the ceiling is working fine, but the fan outside is not turning on. When I went to look for an overload reset on it, I switched off the breaker on my second floor unit by accident, and now it is doing the same thing. Both fans on the outside will not turn on. Both thermostats will turn on the air handlers in the ceiling. Seems like I re-created the same exact pr


... Goodman CPLE24-1 Air Conditioner

Earlier this week, I noticed that the house felt "stuffy" but the thermostat showed everything to be cooling as expected. Last night, the house was definitely warmer than expected when we got home. My husband did some checking and found that the outside unit was running as normal, but there was no cool air coming through the vents inside the house. turning the a/c unit off at the thermostat did NOT turn off the outside unit...was only able to do this at the circuit breaker. It seems that the fan


Nope, nope, sounds like a stuck contactor in the electrical compartment of the condenser, but there are actually several things that could cause it. ... Air Conditioners

Hello, my outside unit was freezing up so I turned it off to let it thaw. When I turned the unit back on, the outside unit didn't come back on. I checked the breaker and it was fine. Can you give me any ideas as to what may be wrong? Thanks, Erich


Hi, \012 \012Here is a tip about troubleshooting your air conditioner...\012There are many things that can cause your air conditioner not to cool… ... Goodman Air Conditioners

Earlier this week, I noticed that the house felt "stuffy" but the thermostat showed everything to be cooling as expected. Last night, the house was definitely warmer than expected when we got home. My husband did some checking and found that the outside unit was running as normal, but there was no cool air coming through the vents inside the house. turning the a/c unit off at the thermostat did NOT turn off the outside unit...was only able to do this at the circuit breaker. It seems that the fan


If both fans runs (inside and outside), check if the compresor runs , if does probably the unit is low in freon and needs to be recharged after the freon leak has been fixed (remember this is a seal system and it shouldn't leak), but if the compresso ... Ruud UBHC Air Conditioner

I have a Goodman A/C unit, Inside unit P/N A42-15, my problem is inside blower won't turn on when in A/C outside unit turns on and the copper pipe going to inside unit gets cold, but no blower to circulate air, can some times get blower tot turn on by reseting inside units circuit breakers, also heater works fine.


What about the blower time delay relay: http://americanhvacparts.com/Merchant2/merchant.mvc?Screen ... Air Conditioners

I have a goodman cpk j42 -1b ac unit on the outside and a central heat and air unit inside. the ac unit come on and runs fine but when it hit the temp the thermastat clicks and the fan outside goes of but the one inside stays running and will not turn off unless i hit the breaker. is it he fan relay at the outside ac unit?


Hello BWOOD Check the thermostat FAN button is in AUTO position not ON position.That might be it .The relay is in the blower unit but they RARELY become frozen/welded stuck on. ... Air Conditioners

The outside unit won't shut off, even when the blower is not going. I flipped off the breaker and cleaned the coils. When I turned the breaker back on, the unit came on, even though I turned off the thermostat.


Shorted contactor on outside unit. The contacor works on a 24 volt signal fron the Tstat. Sometimes the contactor contacts weld together. Rusty ... Air Conditioners

I have an american standard air cond. unit outside...I tried to turn it on yesterday and it comes on in the house but no cool air...on the outside the unit is not on, fans not turning etc. checked the breakers inside they are on.....what can I do to troubleshoot. I'm tired of calling the original guys who installed it. I have to call with every season change...winter, summer, winter, summer. I do remember last time I called they replaced something that if I paid extra which I did I could get the


Installed a new controller now nothing works.Marked wires as I removed then from the old controller and installed then into the proper connector on the new controller. Reinstalled old LUX controller and still nothing works. All circuit breakers ... American Standard WCZ036F Air Conditioner

AMCOR 24,000 BTU split system. Worked fine two years, then today it had no power. Checked circuit breaker, it had popped. Reset CB and went to inside unit - would not turn on or off with remote or hard button. Checked wiring with an electrical tester, and wires to outside unit hot, as well as inside unit. No flashing codes, nothing. Unit won't turn on,even with power. Is there a fuse somewhere in the inner unit or outer unit?


I had this same problem. I disconnected the thermostat wire out side at the condenser and reconnected it and it started working. A couple days later it blew the breaker again this time I found the bus where the L1, L2. GR wire connect at the condense ... AmcorAire UCHW-H24AF2 Split System Air Conditioner

Rudd central unit , turn A/C on[therm. inside] all U can hear is a Buzzing noise coming from the outside unit , found that [1] capacitor wire had been BURNT , changed wire , then changed capacitor , turned unit on[inside], 1st nothing ???? went inside & ck'd *breaker box* , fuse is operated by "dual arm[tied together] flipped off then on & went back turned a/c back on , came on for [maybe couple of minutes] then STOP'd , tried '1' more time , all U hear is the BUZZ noise? U could smell SMOKE & H


Hello\015\012Before you buy a new condensor fan motor check the contacts to the motor are not worn or pitted.\015\012\015\012Hold or push the contactor in by using an insulated screwdriver and see if the fan motor turns.\015\0 ... Air Conditioners

I wired the unitfrom the outside breaker box,on the inside unit i have a switch that cut the power to the unit and turns it on.when i turn that switch to on my unit started making noise like it trying to run so i turn my thermostat to on my heat acts like its coming on and then my transformer blows.this happen twice


It may be wiring is wrong.Make sure the ground goes to ground, and the other 2 , 110 volts each, go to correct contactor poles. ... Ruud UBHC Air Conditioner

My fridgedaire window unit A/C and heat won't come on. I had replaced an outside light fixture a couple of weeks ago and had turned off the circuit breaker that affected this unit too. Now the unit won't come on AT ALL. I've unplugged the unit, then flipped breaker off then on again. Then plugged back in and hit "Reset" Button on the plug, then waited at least 3 min. as instructed, but still no power. The light on the plug doesn't even come on when I hit the test button. Could it be a faulty cor


Plug a light into the outlet used for the A/C, if the light does not come on when reset then the circuit breaker that provided the power to the outlet need to be reset or replaced. ... Frigidaire FAS257S2A WallWindow Air Conditioner