Fan does not come this seems but the compresser will. this seems to happen afer the unit has been on for approximently a half hour. when i did the test on the board everything worked except the fan modes. yet it works sometimes but fails the test. help me please.


Answers :

Hi,
\012The fan realy on the board is going bad... unfortunately you will have to replace the whole board...
\012
\012heatman101

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Fan does not come this seems but the compresser will. this seems to happen afer the unit has been on for approximently a half hour. when i did the test on the board everything worked except the fan modes. yet it works sometimes but fails the test. help me please.


Hi,\012The fan realy on the board is going bad... unfortunately you will have to replace the whole board...\012\012heatman101 ... Air Conditioners

I'm a 35 yr home builder in northern Ohio. I built a new house for myself two years ago and had my HVAC contractor install a trane system, he nat gas furnace, a/c, electronic air filter and trane humidifier. Starting my third winter here and the humidifier has never ran except in the test mode. They have been back out 3 times and say everything is working properly. I set the humidistat on the highest setting and it has never ran, except test mode. I can't get any sweating on my windows at


It's supplier responsibility to make the unit right. are you controlling your dehumidifier with remote, If so, remove battery in remote and reset it. And then check. If still problem, please get manuals fro the following site and do accordingly ... Air Conditioners

Fan coil unit not cold. msxy-09sv. The other four fan coil units are fine. This fan coil unit is working and all controls seem to be working fine except refrigerant did seem to come into the coil. No alarm or fault detected. Temp sensor seems to be OK. Fan is running but not cold.


... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

Amana PTAC Unit is not producing heat. Fan works fine. can not locate manual reset for heat although a label on the unit says there is one. I have an Amana pth153b35ae ptac unit that the heat will not come on. The compressor will run in the cooling mode but not in heat mode. I verified the switching valve is working and the capacitor seems to be fine as the compressor will run in cooling mode. The thermostats seem to be functional because relays can be heard clearly when changing temperature se


I know this is late but I had to add a solution to this problem since I had the exact same problem and was able to solve it. The probelm is not your control board. On these units, the heat pump compressor will not kick in unless the temperature you ... Amana PTH123B25AJ Heat Pump Air Conditioner

The fan speed in my mini split a/c indoor unit is abnormaly low even when set in High speed mode. This unit also has a powerful mode to raise the speed beyond High for 15 minutes, but it is not working either. I replaced the fan motor, the power supply board and the main board to no avail. Any help will be appreciated.


Please change the fan capacitor,all will be ok afterwards. ... Air Conditioners

Installed the Altura 56" fan (56ATR), worked fine at all speed until we put on the light. Everything worked fine for about 10 minutes, then the fan stopped working, but the light stayed on. Kept trying to get the fan to start at any speed but no luck. Seems as though something may have burned out after we installed the light.


Both the fan and light have a common connection .. usually all the white wires are connected at one wire nut .. check to see if the fan wire has pulled out of the wire nut ... remove the wire nut and re-tighten it .. pull on each wire to make sure ea ... Air Conditioners

Ruud furnace Model UGPH-10EBRJR Silhouette ll. blower fan stays on continously, (also draft blower) and the only way it will shut off is to disconnect power. I've replaced thermostat, fan limiter switch, switch on the blower housing, even replace circuit board (IFC). I've even disconnected the thermostat wires to circuit board and blower still comes on as aoon as power is connected. I've disconnected everything on the circuit board except for blower wires and 24 volt transformer and it still com


... Air Conditioners

I have an ultimate 50 ff,the fan coolining impellers broke and the boiler stopped working, i replaced the fan unit but the boiler would not work straight away,i removed one of the air hoses from the fan unit and started the boiler,then re-fitted the hose,now everything seems ok,does this sound ok?


... Air Conditioners

Frigidare window air conditioner with remote control about 3 yrs old. All controls seem to be working except when the energy saver mode is suppose to shut down the unit / the display goes dark but the units compressor seems to be still running after shutdown?? Unit will not shut completely off unless we unplug entire unit. Unit also has a built in safety breaker switch on plug which works fine. Any suggestions?????


Hi,There might be many reasons. One of them would be Thermostat. If there is an issue with thermostat, ac would show the above symptoms.Check and let me know.Hope i helped you.Thanks for using ' Fixya ' ... Air Conditioners

Heating problems intertherm mobil home ac and heat works but sometimes red light on thermosat comes on outside unit fan motor runs but fan dose not seems to work fine except for that is there aproblem that needs to be fixed


It sounds like the unit is going into a defrost cycle, which is normal for heat pumps and means all is working ok when it gets around 35 or colder they start to do this more often when the red light goes back off , the outdoor fan should come back o ... Intertherm P3RA-048K Air Conditioner

Hi there I have an lg reverse cycle aircon model LWC122RH-2 and the heating seems to work fine on it at however when I try and put the cool mode on it desn't seem to get very cold and the cool light does not come on also the defrost light doesn't come on but the heat light and the fan light and timer lights all work and come on ...please help


... LG Heat cool Window Air Conditioner

I have a Coleman G9T08012DHB13C gas furnace that the draft inducer fan won't start, but the fan is good. I've checked the 2 limit switches and they seem to be working. I've replaced the ignition board and still it isn't working correctly.


... Air Conditioners

Our Furnace doesnt seem to be working correct. We an: Air Pro BGM075128 and is Natural Gas. It will turn on when we turn up the thermostat.. but we never get any heat through the vents. There is a switch on the side that is "on" and one that is "fan". If we turn on the "fan" only cold air gets blown through. It looks like this is for cool air. So, if we leave the fan off and the "on" swith on, we get the furnace firing up, but no heat ever comes through the vents. I tested out the thermo


Sounds like the blower motor is not working, if the furnace is actually lighting up and the burns are ignited. You should set your thermostat to auto, as if it is on fan then the fan runs all the time until you take it off of fan. I am a little confu ... Air Conditioners

My Ruud heat pump fan stops after running a minute. It is 10 degrees out now and defrost mode seems to work fine. It makes a humming sound when the fan gets stuck. Sometimes if I take a ruler to it, it will unstick and starts spinning but not other times. cover over the fan motor feels very warm, almost hot to the hand. I've shut it off totally for now.


Hi,The capacitor for the fan motor is bad...replace the capacitor and you'll be good to go...\012Here is a tip about troubleshooting your air conditioner...\012There are many things t ... Ruud UBHC Air Conditioner

Fujitsu inverter hello my name is jim. my fujitsu works on all areas except heating. when turned on the it makes all the moves as it is about to work but stops as it is frozen with very little air coming out.it also has the timer light flashig constently and the operation light flashes 5 times every 10 seconds. on cooling , dry , fan it seems to power on and all levels of speed work ok.


... Air Conditioners

GOODMAN CMA80905CXBA FURNACE. INDUCTION BLOWER NOT ENERGIZING. GETTING 3 "BLINKS" FROM DIAGNOSTIC LIGHT (LOW PRESSURE SWITCH OPEN). THE A/C WORKS & THE BLOWER FAN COMES ON WHEN THE STAT IS IN THE HEAT MODE WITH THE FAN SWITCH ON. WHILE THE FAN IS ON , THE DIAGNOSTIC LED STILL BLINKS A CODE OF 3. THIS IS NOT A CONDENSING FURNACE. I BYPASSED THE STAT (W & R)TWISTED TOGETHER---SAME RESULT---DIAG LED COMES ON STEADY, THEN FOUR CLICKS, AND BACK TO THE CODE OF 3 BLINKS. CIRCUIT BOARD???? OR 120VAC NOT


The pressure switch is closed before the draft motor closes it.the board is telling you that this is not right.pull the wire(either) off of the pressure switch to see if furnace tries to light.if it does,you should replace the pressure switch. ... Goodman Air Conditioners

Hav a lg model lsnc 1264 dmo indoor fan does not work could it be the pc board or the fan motor how do i test the fan is not siezed thanks tony


... LG Air Conditioners

During air condition mode fan does not run unit freezes up and there is a red flashing light on the circuit control board. The board # is GMP 125-5. The outside compressor work normally.


Dear tomsandi,\015\012 Either the fan motor is burnt out or it is not getting the power supply, hence the fan is not working. Since there is no air passing through the evaporator the cooling is not taken off fron the co ... Air Conditioners

I have a Haier HPRBO7XC7 portable air conditioner that isn't working properly. When I turn the air conditioning mode on, the cooling unit seems to turn on, but then stops after about a minute or so, and the fan just keeps running. The unit is only about a year old. I purchased it last summer, it worked fine and then when I pulled it out the other day, it had this problem. Any suggestions?


... Haier Air Conditioners

I installed a cpg0902103bxxxba it worked good for a couple of weeks and then on the heat mode it timed out with one blinking light on the board. which means check limit switches gas valve and gas flow and flame sensor. i checked all that and wiring everything checked ok so im wondering what else to check i think it may be the board?


... Goodman Air Conditioners

HI brand JNC MOD JAC-24Y2 The air con is stuck in timer mode ! we can set the temp but it refuses to come out of timer mode , the remote control is working [it was tested it is sending a signel ] a technition advised us that the control pcb is at fault & can not get parts . i'm an electronic technicion & i can repair the board at component level but i would need a circuit drawing . hope some one can help with thanks jim brickwood


... Air Conditioners

Not colling, everything seems to be working inside the furnace, outside the unit does not make any sounds nor the outside fan is working.


You need to check for 240volts a.c. at the unit,then if you have it there then check for the low voltage 24 v.a.c. that controls the outside contactor that sends power to the compressor,if you have power to these components then replace the dual-sect ... Goodman CKL49AR49 Air Conditioner

Intermittent heat I have a Carrier (Payne) unit (FA4ANF030) with intermittent heat output. The air works as does the fan when in heat mode, but usually no heat. Sometimes it will suddenly begin to put out heat normally and will function fine...until it doesn't. The thermostat was old, so I replaced it first. Seems to make no difference at all since it works exactly as before.


Check wiring of heater, it may have loosed connection or corroded connection. ... Air Conditioners

Contactor not engaging to start condenser unit . When setting the thermnostat, i hear the click from the unit starting inside the house. Fans start and air starts blowing inside the house, but the condenser unit never starts. I tryed pushing the contactor by hand and then everything works find (cool house) as long as i keep the contactor pushed manually. Seems alike the 24 V (coil) bobine in the contactor is not been energize. When I tried the 24 V outside with a 24 V surce it worked fine. Thank


I would replace the contactor if you are getting 24 volts to the contactor and it isn't engaging therefore the magneto on the contactor is out and the contactor will need replacement. If you don't have 24 volts at the contactor then the transformer ... Air Conditioners

RV Dometic Duo Therm roof top AC w/heat pump Model #630515.321El Serial #21631212 Yr. 2003. It is the rear unit, front unit working fine. In AC mode it is blowing hot air as if the heat pump is on. Fan and compressor are working. Thermostat control was replaced and a new circuit board was applied, but did not solve issue. What is the answer to solve it?


If the Air comeing out is the same as the temp inside the RV make sure the compressor is running and not just the fans. It could be low on freon. If freon is ok then you would need to ck the wiring to the selector switch for a short. It would be obvi ... Dometic Rooftop RV Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1093 seconds