Having problems with your Air Conditioners ?

I have a problem with my 8000 BTU Fedders AC window unit. Error code EE comes preventing the unit from running. What part does this indicate to bad?


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a problem with my 8000 BTU Fedders AC window unit. Error code EE comes preventing the unit from running. What part does this indicate to bad?


... Fedders D Chassis A6D24E7A Air Conditioner

I have a Carrier infinity model 38tdb037-3. The outside unit will not come on. the control board on the outside unit shows an amber led on status 2.it is a steady constant flash.the error is an apparent stand by/on demand.munualy depressing the contactor forces the unit to run and seem to work fine. communication is good. the inside unit shows two green leds and one amber constant flash. any ideals. maybe bad control board?


... Carrier Air Conditioners

I have a American Comfort 500ch. The pump to drain the water out continues to run and when the basin is empty, the pump will continue to run and is very loud. It will do this for a few minutes then turn off and the indicator to drain the unit comes on. It is still under warrenty but I have to pay for the shipping both ways. I can' t locate any parts for this. can you help. thanks for any help in advance.


Apparently, American Comfort has a plan to start selling parts and accessories online in the near future. However, if your unit is still under warranty and the only thing you have to pay for is shipping both ways, is attempting to repair it yourself ... AMERICAN Comfort ACW500CH Portable Air Conditioner

I have a Haier room air conditioner that has been running for about a month. The E1 light comes on and will not go off. The unit cannot be powered off using the power button, only by disconnecting. After disconnecting and following directions for removing the E1 light, it goes to E2 and the same problem. The unit will not run. How do we get this unit to remove the error lights and run correctly? Thanks.


Hi,\012Here is a tip that gives a further explanation of that E-1 code. The causes of the E-1 code can be varied depending or the brand of your air conditioner.Read through this tip... it will help you under ... Haier Air Conditioners

I have a 1993 Model SRHF48U01A (The 0 might be a O (zero) When the thermostat calls for cooling, the inside unit (fan) starts up and continues to run but the outside unit wants to start (it comes on for a second and then trips the breaker that is located behind the outside unit. I can turn the breakers off that are inside the house and let them stay off for a short time and then reset the outside breaker and then turn the inside breakers on and the unit starts and continues to run until the te


Well the trouble is surely at the compressor side. Dont know what kind of repair man you invited. He should have atleast diagnosed the problem. Following can be the causes\015\012\015\0121. Capacitor is slightly faulty (As you said). If t ... Amana Air Conditioners

I installed a new colman mack thermostat in my camper witch has a colman ac unit now ac unit runs 5 min then shuts off for 3 min then starts again and keeps doing this . so I by past thermostat and it will keep runing and cool down camper good that way do I have a bad thermostat or the wrong one part number on ac unit is 7330-730 part number on thermostat is ap7862


If it is a programmable thermostat you can unhook thermostat and when it comes on select 3 instead of 1. As it sounds as though it is short cycling this happens in older houses with drafts. Hope this helps Tim ... Coleman Mach III Air Conditioner

I have an Interthem / Nordyne heat pump model E2EB-015HA. On the outside unit the fan does not turn on when the unit comes on. If I spin the fan it will come on and will run well. With the unit off the fan blades spin easily. I suspect the capacitor, but can not find a part number for it. The capacitor itself is rusty and any writing is unreadable. Please help.


Not sure what Country you're in but the Part No for the Run Capacitor is 1499-4461 and can be purchased from the following link.\015\012\015\012htt ... Air Conditioners

Hi, The unit comes up with an error code CH then 1 and alternates continuously. the indoor unit fan runs but the outside unit fan does not. What does the error code mean


Magnatic contector is faulty or its coil burnd ... Air Conditioners

Eo error code indoor unit runs 2-3 seconds then gives eo error code problem started when mr chipmunk chewed mr slims 12 volt wire connecting to out door unit and shorted it . Outdoor unit has bad control board


You need a professional here. Once this has been repaired, I would suggest running the wiring to the outdoor unit inside some sort of piping to protect it. ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

I purchased an Amcoraire split system unit for my 2 story garage. Licensced electrician did the wiring and licensed HVAC co. installed the 2 indoor units and outside unit. Outdoor unit is Model # AOM 243 HX 24000 BTU Indoor units are both Model #AWM123 HX, 12000 BTU each When I turn the unit on, it runs for about 60 seconds and then I get an error code on the inside wall unit that says P7. My manual says this has something to do with voltage. I had the power company come out and they show the


Since the manual says the error code has something to do with voltage it means the voltage is either too high or too low. And as the electric company says the voltage is within limits the the error is as a result of the voltage fluctuating. All you h ... Amcor Air Conditioners

I have LG LMU240HE multi type air conditioner. It is about 5 years old. It will not stay on. When power on, runs about 30 seconds and power indicator blinks and Sleep mode indicator comes on and completely shuts down. I have two units and both are acting the same. I have cleaned well, checked power supply, used remote to cancel sleep mode, reset remote numerous times and still not running. Please help.


... LG LMAN090HNS/LMU240HE Air Conditioner

Blower fan in the inside unit tries to turn on but wont. It can be turned manually and air conditioner comes on and runs fine. The " squirrel " cage spins completely freely and is not sticky or jammed. Is the motor bad or is it a run capacitor. Model number of inside unit is a49-15


\011Sound more like the cap, but if the motor is raging hot, it could be the motor, another thing it could is improper voltage although less likely. But Goodmans/ do have this weird fan relay issue were they just bite it some times. I wo ... Goodman Air Conditioners

Air handler fan running but AC unit is not. Reset ckt breaker off and then back on with no results. Went outside and checked fuse box near the AC unit. Inside box has two red lights with wording Line 1 fuse bad when lit and line 2 fuse bad when lit. In this case the Line 2 light is illuminated. Can you tell me what this is an indication of problem?


... Air Conditioners

Hi, I have a LG NEO PLASMA S18AHN SPLIT UNIT, It was already installed in our house upon us purchasing it, it would be approx 3 years old, has been pretty much running 24/7 and has been great up until recent, about 6months ago it stop and displayed the C6 error code, at this time I replace the external units motor start capacitor, it ran perfertly again for the next 4months, until it stopped again and again after reseting. When trying to run on Heat it comes straight up with "Defrost Mode" it


My lg 18 000 btu split neo plasma is on heating in any mode u put it\015\012what do u think is the problem ... LG Air Conditioners

My coleman Mach Rv air conditioner with built in heat strip keeps tripping it's internal circuit breaker when running for any length of time. Just replaced heat strip with new one experienced same issue. I ended up with the fan continuing to run but only cold air comes out of the vents! When I removed the old unit and reset the circuit breaker it too worked again. Have no idea what is causing this to happen. The airconditing part of unit works just fine??? HELP! Ron


There should be an overload protection device in series with the low voltage wiring(t-stat wiring) Is it resting on the heat strip or too close to it? It is a saftey device to shut off the heat strips if the fan quits or a fire in the heat strip sec ... Coleman Mach III Air Conditioner

I have an old unit approx.11yrs old.When turn on for heat,kicks my breakers off. It runs for about 1/2 hr. before shutting off. Tried running the emergency heat bu t, it continues to kick the breakers off within 1/2 hr. Were can I find parts for this unit, I just need to get through the winter. I will be leaving this home come the spring. I do not want to spend the money on a new system for a home I will not continue to live in.


Well, obviously your furnace is overloading the breaker it is on. Try this, turn off the breaker that the furnace is on and go through your house to make sure everything else still works. Furnaces are large power users and should preferably be on t ... Amana Air Conditioners

I have an goodman model # gsc130241ae ac unit outside it will not come on, no hum, fan doesn't run thermostat control is good swaped out with downstairs unit. Gas heat unit is in the attic, I don't use this part of the unit during the winter because this is the #2 unit for upstairs. Downstairs unit works great circuit breaker is on


Does the blower indoors run and move air? if not it would mean that you don't have power to the furnace.\015\012The 24 volt transformer in the furnace is used to power the thermostat and the control circuit on the A/C unit outdoors. Or you coul ... Goodman CLQ36AR49 Air Conditioner

EverStar MPM2-10CR-BB6. Comp. only runs for about 30 sec. then shuts off. Air is cold while the comp. is running. Fans continue to run. Fan slows then speeds up. Blows hot air for a couple minutes. Comp. comes on and symptoms are repeated. No error codes. Whats up? Unit is 1yr old.


Check the start gear for the comp. ... Danby DPAC8020 Air Conditioner

I have a Mitsubishi Mr Slim PK36FK3 and i get error 8 on the codes. I have cleaned the filters and checked to see there is nothing blocking the condenser fans. The fuses do not blow and the breaker does not trip. The unit stops and the green power light flashes with error P8. I can turn it off and on again and it will run for a while. Then the same error messages comes up. What is the problem????


Hi\015\012\015\012There are many things that can trigger that code. The most likely is a power problem...ie. Outage. Reset, and Recycle the power off and on and it take off and run.Other things to check are:1 Wrong wiring of I ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

CARRIER AIR CONDITIONER/HEAT PUMP PROBLEM WOULD NOT RESPOND TO THERMOSTAT. UNIT IS AT LAKE HOUSE WHERE WE DO HAVE BAD STORMS. IN CHECKING, INSIDE PART OF UNIT HAD BURNED UP THE TRANSFORMER BUT NOT BLOWN THE FUSE. REPLACED TRANSFORMER . . . COULD SMELL AND THIS TIME TRANSFORMER STARTED TO MELT AND BLEW FUSE. SOMETIMES THE FAN WOULDN'T EVEN COME ON WHEN JUST SWITCHED FAN "ON" AT THE THERMOSTAT. QUESTIONS: WHAT WOULD KEEP BURNING UP TRANSFORMER. WE REPLACED WITH EXACT TYPE THAT WAS ORI


What I have always been told is if your 24 volt side burns out check the high volt side if the hi volt side burns out check the low volt side.A quick way if the primary side is burningout due to a problem with the low volt side:1 MA ... Air Conditioners

Ac comes on compressor runs maybe 3 minutes than shuts off and comes on again. Does this indicate a bad compresssor?


This could be do to low on refrigerant, a dirty evaporator or filter, or a blower not running or not running at the proper speed and a low pressure switch opening due to low pressure. It also could be due to a dirty condenser or condenser fan not run ... Maytag M6X06F2A Air Conditioner

I have a Duo-Therm RV Roof Air Conditioner Model 57915.622, Prod # 991731648, Ser # 84818800. It will not run. I changed the Compressor and Fan start capacitors. When I turn the unit on at the Thermostat nothing comes on. The Air Conditioner Control Unit E155095, Part # 3107541.009. The fuses are okay.


... Dometic Rooftop RV Air Conditioner

I have a 98 Sunnybrook w/Dometic Furnace-A/C thermostat control. Just the other day, the furnace would keep running and it got very hot in the trailer until I could shut it off. The thermostat was set kind of low, but we needed to keep a little heat on in case we got a freeze. Do I need to replace the control unit which is electronic to correct the problem? I am assuming the thermostat went bad, but am also assuming it is a part of the control unit?! Thanks for your help. Dave


... Air Conditioners

I have an quite old AC Unit with an 18.6A 230V 60c/s single phase compressor motor MODEL BY0086B112E1 (the sub-lined "8" is badly readable, could be a "3") SERIAL 355350T23 max breaker indicated as 45A (mine is 40A) I probably will need to buy a replacement motor I do not know, as I have no catalogue, if the motor has a Run Capacitor, but I assume this is a 3 HP without RUN, only START capacitor. You surly can get the data. I must choose between buy such new motor or a modern new


It does not look like they still make the motor for this unit, you will want to call GE directly to confirm though. 1-800-626-2005 They are still open yet this evening However you will be better served by calling these folks tomorrow, t ... GE AGQ10AC Central Air Conditioner

I have a Mitsubishi Mr slim (PUH6YK2) aircond unit with a p8 error that comes up after startup,which then shuts the compressor down and just runs the fan. could you please help with this error


... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific