How many tons is a Goodman Central Air Unit with Model Number CKL30-IE?


Answers :

That is a 2.5 ton system. The model numbers are as indicated:

24- 2 ton.
30- 2.5 ton.
36- 3 ton.
42- 3.5 ton.
48- 4 ton.
60- 5 ton.

Hope this answers your question!

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

How many tons is a Goodman Central Air Unit with Model Number CKL30-IE?


That is a 2.5 ton system. The model numbers are as indicated:24- 2 ton.30- 2.5 ton.36- 3 ton.42- 3.5 ton.48- 4 ton. 60- 5 ton. Hope this answers your question! ... Goodman CKL60AR60 Air Conditioner

Hello. I would like to know how many ton my Coleman Central Air Unit is. The model number is 'ERCS0241BBB". The serial number is "WOD7699360". Thank you.


This is a 2 ton A/C I got that from the 24 in model number it means 24,000 btu which equals 2 tons cooling. If this helps please rate me and do a testimonial. ... Coleman Air Conditioners

Details I have a problem with a Goodman Model GSH130601AA, ( 5 Ton, 13 Seer heat pump) central air unit, installed 06/15/2006. (I know, I saw online reviews but unit was put in before I saw negative e


The fan motor is bad and needs replaced. Depending on how mechanically inclined you are, you can replace it yourself fairly easy, the hardest part being the fan blade without a hub puller. Just take your old one in with you to a local A/C supply stor ... Air Conditioners

Central air only blows a small amount of cool air out the vents. After running 12 hours it only cooled my small 1BR apartment 3 degrees. The filter has not been replaced since October 2009 but I can't seem to get it out of it's little slot at the bottom of the unit. It's a Goodman Manufacturing Model Number ARUF024-00-1A. The air filter is loose but won't slide over the bottom metal lip. Is it okay to (a little aggressively) wiggle it out? Thank you so much!


I have a Goodman A/C unit APRF036-00B1. The out side unit seems to be sucking and bowing air, the coil is cool to the the touch and the blower seems to be turning. I've check what seems to be the obvious. A small amount of air is only coming out. Any ... Goodman CKL36AR36 Air Conditioner

How many tons is my Kenmore Central Air Unit - Goodman CKL60AR60 Air Conditioner


You can tell by the model # ... Goodman CKL60AR60 Air Conditioner

Can a Goodman AC unit with a model number of a 24BTU-2 ton unit be upgraded to a 3 ton unit by changing the piston and the settings on the blower? They are also going to install a 3 ton compressor outside. Would this provide the same cooling capacity and performance of changing the actural HVAC unit to a 3 ton unit and would Goodman give me directions stating as much?


They would need to change the coil indoors to a 3 ton. If the blower speed can be increased it should be fine. ... Air Conditioners

PCK048 Goodman Central Air Conditioner Unit Model Number PCKD48-1 or G0182770080 or PCK048-1


... Air Conditioners

What type of capacitor comes with a 5 ton Goodman Air conditioning unit model number CK60-1C


The best way to know what size capacitor it needs is to look on the label of the fan motor itself. It will tell you the size it needs. Condenser fan motors get replaced all the time with different capacitors needed. If you cant find a label or its to ... Goodman CKL60AR60 Air Conditioner

How many tons is a Goodman central unit Model # cple48-1A


... Air Conditioners

What is the rating (tons) on my goodman central air conditioner model number ct42-1b


... Goodman Air Conditioners

Evaporator Coil I have a Goodman A/C system (2 systems...1 for 1st floor, 1 for 2nd floor). The one for downstairs is 3.5 ton. the one for 2nd floor is 3 ton unit. Installed when house was built 5 1/2 years ago. The upstairs unit has had the evap coil replaced once, and repaired a leak once - 6 months ago. The downstairs unit has had the evap coil replaced twice -and is now leaking again. Model for the air handler is ARUF042-00A-1A. Goodman part# for the coil is P140142. Can I replace this coil


Yes, just count how many pins per inch and replace with the same number of pins per inch. ... Air Conditioners

Looking for freon capacity for 5 ton goodman package unit, cannot read serial or model number.. unit is 1998-2000 model ,, we just replaced the accumulator and we are not sure how much freon to put in.. Goodman offers no help whatsoever.


Check low side which is the bigger of the two, make sure you tighten the hose good. your reading should be 65 psig.If not add refrigerant/r22 . if r410a 110 to 115. ... Goodman GPC1342H21A Air Conditioner

My goodman central air unit quit working after a storm. The circuit breaker is not blown. The furnace fan kicks on when ac is turned on at the thermostat but unit outside does not operate. Is there an internal fuse or capacitor on outside unit. Thank you very much, Bryan Model CKL36-IF Goodman


1 posible cause.the thermostat supplies 24 volts to the outside unit to control the contactor if you hear a ligth huming on the outside unit this is the being activated. if this is the case then\015\012\015\012 check to see if any ants are in ... Goodman Air Conditioners

I have a central air conditioning unit in the apartment where I live. It is a split unit - somewhere outside is my outdoor unit (and everybody elses too). Anyway I seem to get way too much humidity in my apartment. The air conditioner I suspect is 15 or 20 years old or more. The label on the indoor part is almost unreadable. Carrier is the maker. The model might be 40AC02450052. There are also other numbers 40AC901190 ? or 40709010 ? Can anyone identify what I have? I would like to know how old


The humidity problem is from the condesation drain. It is more than likely to be clogged up keeping water in the condensation pan causing the humidity problem. This can be cured by a wet vac put onto the outside drain for the inside condensation pa ... Carrier 38CKC030 Air Conditioner

We installed a 4 ton downflow coleman air handler with evap coil Model number 1854s2m we did not change out the outside unit. the outside unit is a 13 year old 3 1/2 ton intertherm condenser the system is only generating a 10 degree delta T. My question is, this coil came with a factory TXV I am trying to find out is this a 10 seer or 13 seer coil is it compatable with the outside unit.


You have a missmatched system, for it to work try removing the orfice on the high side txv it is not allowing the evaperator coil to fill with refrigerant properly coleman and intertherm dont like each other since they control a large market in the ... Air Conditioners

I have a Goodman 2.0 model no. ck24-1B and would like to change it to a 2.5 Ton 13 SEER R-410A Air Conditioning Condensing Unit. My furnace is a Goodman model # GMS8, GDS8 or GHS8 are they compatible


If it is a 410a system now you would have to change orfice. if its a r22 system now no way. ... Goodman Air Conditioners

Need some answers for a Coleman Evcon central air unit, Model number BPCH0361BA.


... Coleman Air Conditioners

We have a central air unit that is serial number BTR736B100A0 and model number 314127T18. I need to know the size of the unit. What square footage of house is this for?


This is a 3 ton unit. I go tthat from the 36 in your serial number. 36 means 36,000 btu's which equals 3 tons which cools a home 1,500 square feet to 1,700. If this help please rate me and do a testimonial. ... GE Air Conditioners

Out door unit model number PV-6YARD This model number Air conditioner howmutch Ton


Seems to be 1/2 ton. Please write which brand it belongs to and also indoor model also. If not write BTU. 12,000 BTU = 1TR. Thanks. ... Air Conditioners

Model number brcq0361bd how big is this central air unit


... Air Conditioners

I would like to know how many square feet a Model # BRCQ0421BD Serial # 990905429 Coleman Central Air Conditioning Unit will cover. The unit supply is 208-230V 1 PH 60 Hz 10.8 RLA 97 LRA.


... Coleman Air Conditioners

I have a Rheem CLassic 10 Seer Heat Pump Model Number is RPKA-035JAZ I'm not familiar with certain terminology, but basically, it seems as though the unit is not cooling down the house anymore. It is just blowing air. The thermostat is not on "Fan", it is on "Cool". The central air system is not on "Auto" but "On" for continuous cooling. The temperature is on 65 degrees but not change has been made. It's not hot in the house but it certainly isn't cool and it feels as the there is less air p


Hello my name is Heath it will be my pleasure to assist you. The auto or on switch is the fan switch put this on auto. Then on the thermostat set it to cool and turn the thermostat down and the outside unit should come on and the house should cool d ... Air Conditioners

How many tons is a goodman model #CKL 49 -1 - Goodman Air Conditioners


... Goodman Air Conditioners

We have a 3 1/2 ton unit the internal blower is blowing but the fan on the top of the unit is not turning and we have air blowing out of the vent but it is not cold model number gph1342h21ae


Hi,If it is just the fan then the motor needs to be replaced...let it cool a few hours and then try it and see if it is just the fan or the fan and compressor that does not work...If neither will start then either the t-stat is not workin ... Goodman Air Conditioners

CE25-1EB I have a Goodman Central Air Conditioner that had the condensor motor fan and cap stolen out of it...The model Number is CE25-1EB, Serial Number is 9305081968. I am needing to get the size of the Capacitor and the fan pitch. Can anyone help me get this information??


Http://gethuman.com/phone-number/Goodman-Manufacturing-Co \012 Phone Number\012 ... Goodmans Air Conditioners