Having problems with your Air Conditioners ?

My son has a Goodman Manufacturer Corp Heat Pump/air conditioner. Forced air I believe. The air conditioner quit. A repairman indicated that in order to replace the air conditioner the furnace will have to be replaced also. The air conditioner unit outside is Model No. CPE30-1-AB. Any thoughts?


Answers :

I don't see any reason to change the furnace unless it's an air handler and not a furnace with a coil on top or bottom. And then, the only reason to change the inside unit when you change the outside unit is because it's a R-22 system and your going back with a 410A system. They just discontinued R-22 equipment this year and not a lot are still available. But even if that's the case, the only thing they should have to replace is the coil and maybe the copper line set. That's all I can think of. Hope this helps!

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

My son has a Goodman Manufacturer Corp Heat Pump/air conditioner. Forced air I believe. The air conditioner quit. A repairman indicated that in order to replace the air conditioner the furnace will have to be replaced also. The air conditioner unit outside is Model No. CPE30-1-AB. Any thoughts?


I don't see any reason to change the furnace unless it's an air handler and not a furnace with a coil on top or bottom. And then, the only reason to change the inside unit when you change the outside unit is because it's a R-22 system and your going ... Goodman CKL30AR30 Air Conditioner

I have a Goodman Air Conditioner Model CK49-1B. The fan in the unit does not turn on when the thermostate is set for cooling; the fan in the furnace works and blows warm air. Checking outside I discover that the dog chewed three wires that are coming from the unit. The repair person told me that the dog shortout the CONTACTOR and had to be replaced it, he also replaced 12 inches of wires damaged by the dog.. He did the job in less than one hour and charged me $225.00. Did he over charge me? Late


Take a look on amazon for same parts, and compare the prices: Amazon com goodman air conditioner parts. I hope this was helpful. Cheers ... Goodman CLQ36AR49 Air Conditioner

I have a DuoTherm BriskAIr 13.5K BTU. The Dometic thermostat also controls my HydroFlame 8531-IV furnace. This morning, the furnace would not come on. I checked the wiring and there is no voltage at the thermostat blue wire on the furnace. If I jump 12 volts to the thermostat blue wire, the furnace works normally. Replaced thermostat; no change. I hear something clicking in the air conditioner unit when I switch the thermostat to furnace mode. I assume the A/C has a relay to control the thermost


If you look at control box at roof unit, they usually use a separate set of wires for furnace. See what colors they are attached to at harness to thermostat. Some just follow other harness, and come out at thermostat. (bypass control box) Once you've ... Dometic Rooftop RV Air Conditioner

We have a Goodman Furnace and Air Conditioner approx 7 years old. When I put the Cool on thermostat and lowered the temperature for the air conditioner to come on the furnace fan started but the outside air conditioner only made a humminging sound. How long does it take for the air conditioner to start? I thought in previous years it came on quickly. I changed batteries in thermostat and reset the brakers on the main electrical panel. Could you please give me some advice. Thank you.


Hi, You are right. The outside unit starts quickly. The humming will either be the evaporator fan or the AC compressor itself. If you can reach into the evaporater fan with something narrow and stiff you may be able to see if the fan turns. Sor ... Air Conditioners

I have a suburban lp furnace and duotherm air/heat pump roof unit. duothern thermostat. 20 amp breaker kicked ( reset breaker) & furnace quit. NOW furnace fan comes on but does not light, and the front AC will not work either, when in the COOL position on STAT the unit blows warm air instead of cold. I replaced the Thermostat and a Tech guy checked the board in the furnace and it was OK. He also switched the board from the rear air with the front and nothing changed. Rear air and heat pump works


I'm not sure what the problem may be but you could try calling All\015\012Seasons RV Appliance Parts & Service. There number is\015\0121-800-344-0673 they have helped me in the past. That and there tech\015\012calls are free so it wouldn't hurt ... Dometic Rooftop RV Air Conditioner

I have a gas furnace that was to have a 10acc air conditioner unit installed with it. Instead of the 10acc unit a 10hpr48 heat pump unit was installed, The house is 4 years old and the reversing valve has failed. The unit is not wired as a heat pump but as an ac unit with only three wires. A independent air conditioner repair company has said this installation is inproper.Is this unit installed to code and would lennox guarante a unit installed in this manner?


It should definitly be warrantied. their is nothing wrong with your set up however id have the contrator pull a new wire and go dual fuel withh outdoor sensor and get the full benifit of dual fuel. you should use the hp above 40 ... Air Conditioners

Replacement Remote I can't find a replacement remote for my Turbo Air Conditioner - Room Air-Conditioner. (Info on Wall Unit - Model of indoor unit TAS-9H, Serial # A09HI02196, Bar Code # C2G5101320) (On the back of the remote - ZHF/LW-15, Rated Voltage 3V.DC) I live in Phoenix, AZ if you can tell me some place local I can get one or order one online. Thanks so much, Robert McDonald


EMAIL: [email protected] for parts / remote controls ... Turboair Air Conditioners

The other day. my American standard air conditioning unit (Allegiance 10 model 7A0030A100A0) would not stop running. The furnace was not running, yet the air conditioning unit was on. I could see condensation on the line running to the furnace. The next day the unit would not even start running. I shut it down, tried it the next morning and the unit ran for about 30 sec and stopped. Could the capacitor need replacing?


Yes, that might be the problem but in this case you need a qualified technician to test system and find real cause of problem. ... Air Conditioners

Borg warner Is the old round York Borg/Warner thermostat incompatable with a Honeywell? I just replaced my old round mercy switch thermostat with a Honeywell RTHL111 thermostat. The air conditioner service man says it is hooked up right, but the fan on the unit will not run on auto (it must be in the on position on the thermostat [thus the fan runs all the time]). He also replaced a relay switch inside the unit. We are using air conditioning only on this unit. Red to R (strapped to Rc), gree


... Air Conditioners

Blower motor my air conditioning goes off as soon as it goes on I have a service contract with my local oil company and my repair man said I need a Bryant blower motor 8539DL 51923EEOS I have been told the part is not available because the unit is to old and they recommend replacing my furnace and air conditoner for over $15,000 I am hoping I can buy the replacement motor somewhere so I can save for the future replacement of my units Is this part available anywhere?


YES!! A universal replacement is readily available for around 200$ or so and the labor for the installation should be about the same. Sometimes it's hard to tell the Tech's and the Sales apart....GL! ... Bryant Air Conditioners

Air conditioner I have a Honeywell air conditioner unit. For the last several days it has failed to cool down to the temp I set except at night. When I came in this evening it was 87 degrees in the house. I went to the main unit in the garage and flipped the fuse buttons to off and then back on. Then I dd the same at the main fuse box for the house. (Dont ask me why I thought this would help). Now I can't get the unit to turn on at all. Any ideas?


Yes, first turn your thermostat to the off position. Try to reset both fuse boxes again. If the ac comes back on problem solved, if not fuses and or breakers may need to be replaced.\015\012\015\012Let me know if this helps and we can go futher into ... Haier Energy Star ESA3183 Air Conditioner

I have an Amana Model GUC-C 90 Hi-efficiency furnace that we installed in 1992. It has a central air unit as well. On Friday we tried to turn the air on and nothing will work. I have replaced switches in the air unit in the past but this time there is no clicking, I can't turn the circulation fan on for the unit, the heater unit will not turn on. I have power at the breaker, and on the unit itself there is a on/off switch with a round screw in fuse, that fuse is good and I have power there.


Hello,Your control transformer may have quit on you, or your thermostat may have gone out. The transformer is what supplies the current for the hvac system. The thermostat just controls what relays are energized. Since you have a probl ... Air Conditioners

Need a replacement filter & grill for a Maytag air conditioner heater unit Model MEJ12E7A. And a Emerson air conditioner heater unit filter & front Grille Model # 12GJ44H


... Air Conditioners

I have an amana air command furnace/air conditioner. model ev4 gtc, serial number 569162. it is 25 years old, original furnace when we had home built. it had been working fine, on air conditioner setting. then it stopped working completely. i had this problem a few months ago, called a service person, who spent 5 minutes, told me it was a switch that needs reset if doors are off the unit for a certain period of time and charged me $68. i have tried to look at the layout of the furnace, but what


Hi,it is just a suggestion, don't you think it will be nice for you too get a new one to save you all the stress of repairing?. 25 years is good, but it can be better if you try a new one and there will be newer models which great future ... Amana Air Conditioners

I have a 2011 Wildwood travel trailer. I tried to use the air conditioner for the first time this weekend. When I turned the themostat to cool and 65 degrees the air unit "clicked" one time but the unit did not start. I tried various settings but nothing. When I turned the thermostat off the unit clicked one time again. This is a brand new trailer and the first time I tried the air. Any thoughts?


First thing to check is that the breaker for hydro to AC unit is in the on position. The clicking sounds like 12 VDC is OK but hydro may not be on to it. ... Dometic Rooftop RV Air Conditioner

Hello - I have a heater/air conditioner; when I run the air conditioner it blows water and leaks water into the house. I was told by an air conditioner technician that I need to replace the unit; however it blows super cold air the only issue is that it leaks water. Not sure what I can do? It is a Fredrich Twintemp Model#EL25J35-A Cooling BTU/AR 24600/24000


When the filters, or heat exchanging coil, are dirty or blocked, this causes a restriction in air flow. This in turn can then cause the temperature of the coil to drop. If the coil temperature drops below zero, moisture in the air that is ... Friedrich Air Conditioners

I buy air conditioner mark haier after 3 years the compressore its failer, when replace the compressore and compleate the air conditioner i hear high sound in the outer unit such us the flowing of flow (type of air conditioner split type 2ton cooling and heating reversing valve) thank you wit best regard


If unit was not evacuated after compressor change out it is possible to have are in system. Gas needs to be reclaimed, and evacuated with vacuum pump ,and recharged. Rus ... Air Conditioners

I have a Jayco trailer with a Coleman 7300 Rooftop air conditioner. The unit is 13 years old and it doesn't put out the cold air it used to. I have cleaned the filter which improved the air flow however still not blowing cold air. Is it time to replace the air conditioner or is there something I can do to fix it.


Hi,from your problem its obvious that the problem is from the compressor.its bad and needs a replacement,however this requires the services of a technician and it will cost you a lot of money,however in the nearest future another problem may arise fr ... Coleman Air Conditioners

Hi, I have a samsung aqv18ja series split type air conditioner (cooling and heating) wall unit. the unit was install in 02/12/2009. By "one hour heating and air conditioning". In this short time service the outside compressor has been replace, the system has check and recheck,for cooling leak. the inside unit fan motor has been change. but the problem still exists. The inside unit fan continues to run when the unit is "off" and with the remote off.


Simple, check in your remote. There is an option button "Blow". Just press it. Your unit gets completely off. Please write back if helpful? ... Samsung Air Conditioners

I have a Coleman roof mounted AC unit on a travel trailer. The unit model is 83338715. The unit just blows cool air not cold air like it should. I was told to replace the "Hard Start Capacitor" and "PTCR Start Device" which I did. This did not remedy the problem. Any thoughts would be appreciated. Could the problem be the "Compressor Run Capacitor"? Reason being that I hear no change in the blower sound when the unit kicks on???


Blowing 'cool air' could mean - room temperature air or it could be 'cool' because the system is low on refrigerant, and just barely doing any 'cooling' at all.\012\012To determine which is which - you need to know "for sure" if the compressor ... Air Conditioners

Replacement remote for window unit air conditioner


I have that model Air conditioner with remote. Although the remote is marked Admiral thats the only identifying marks on the outside. Here are pictures of the remote.\015\012\015\012 ... Whirlpool ACC108PS Air Conditioner

B & D company air conditioner(model# 566DJ024-C) makes buzzing noise. I just bought a house and when I turned on the air...the unit outside makes a buzzing noise. The fans seems to work and cooler air is coming out of the vents(only ran it for a few min,didn't want further damage). I had the home inspected and the inspector said that the inside breaker is 30amps and the actual max for this particular unit is 25 amps. I don't know if that is the problem or something else...just thought I'd mentio


The circuit breakers Ampere rating has nothing to do with the buzzing noise. If you use a lesser Ampere Circuit Breaker it will trip every time the Air Con: starts, and if you use a very high Ampere Circuit Breaker it won't trip and give you the need ... Air Conditioners

I have a heil furnace / air conditioner unit. The heil is model # N9MP2075812A3 serial# L024970895. It has an intl comfort evap coil Model EPD24B15C2 serial# X120393352. It was installed in 2003. I turned on my air conditioning and the furnace keeps cycling on and off. I checked the filter and it is new. It is a gas furnace and the gas valve is blinking stadily which means it is ok. It humms....tries to turn on.....blows for about 10-20 seconds....turns off...tries to turn back on...again and ag


Not sure I understand the description.\015\012You said the "furnace" keeps cycling on and off when you turn on the AC.\015\012But you must have meant the AC cycles, because if the actual furnace went on, that would an extremely seroius pr ... Air Conditioners

Several years ago I purchased 2 Split-Type Room Air Conditioners--Models RSW-17 (Indoor Unit)/ROW-17 (Outdoor Unit) and RSW-12S (Indoor Unit)/ROW-12S (Outdoor Unit). The airconditioners themselves are fine, however,the Remote Controls for both these units, Model AR-DJ15, have gone bad and may not be repairable. How/where can I purchase replacement remote units? Alternatively, where/how can I send my remote units for repair? Chester D. Copemann [email protected] or [email protected]


Type in the mfg. name in the search bar and see if you can find resources. ... Air Conditioners

I have a Sanyo air conditioner with a remote (RCS-KS). The HVAC vender who sold me the unit ordered me a replacement remote (RCS-1PS4U-G). I can't get it to talk to my air conditioner. Is there


... Sanyo Split System Air Conditioner

A detailed question is important to get you a relevant answers