Having problems with your Air Conditioners ?

The PAC-260 runs for a few minutes, then I hear the compressor stop and it spews hot air. Pressing the reset button fixes the issue only to have it be reset again after a few minutes. Air filter is fine, the tubes are setup properly (ie. it is a straight run up and into the window). What am I missing, the reset button is supposed to be used when I figure out what is wrong, but I know it works (sort of) because when it works it still is very cold.


Answers :

I had exactly the same problem. After some diagnosis I discovered that the water pump was not engaging so I checked the float switch, it was fine.
\012
\012A press of the red reset button turned the compressor back on for a few minutes but then the same thing happened.
\012
\012So that just left the water pump. After about 10 minutes of use it was getting very hot (the water pump) then the compressor shut off. But if I ran the unit with no water in it, therefore not requiring the water pump to operate it ran with no problems. The only thing was it was a bit louder and not as efficient without water. But still blew cold air :)
\012
\012Eventually I decided to try replace the water pump but thats where I had issues. They are quite rare. I am still waiting to find one.
\012
\012However, that is what the problem turned out to be for mine.
\012
\012Btw after leaving loads of requests for help all over the web... nobody suggested the water pump LOL
\012
\012Cheers
\012
\012Phil (Australia)
\012
\012
\012
\012
\012
Hi, what this reset is for is high head pressure. Its building up high pressure and going off releasing this pressure and tripping the switch. I'm not sure if this is water cooled or has a fan in the back for air cooled. If you can get to the back coil, condenser coil and give it a good washing out with a garden hose to clean it, this will solve your problem if its air cooled only though. Try this to see if it does. If not let me know and we can go from there.
Sincerely,
Shastalaker7

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

The PAC-260 runs for a few minutes, then I hear the compressor stop and it spews hot air. Pressing the reset button fixes the issue only to have it be reset again after a few minutes. Air filter is fine, the tubes are setup properly (ie. it is a straight run up and into the window). What am I missing, the reset button is supposed to be used when I figure out what is wrong, but I know it works (sort of) because when it works it still is very cold.


I had exactly the same problem. After some diagnosis I discovered that the water pump was not engaging so I checked the float switch, it was fine. \012\012A press of the red reset button turned the compressor back on for a few minutes but the ... DeLonghi Pinguino PAC-260 Air Conditioner

My air conditioner stops cooling. Occasionally, it will just function on fan mode even though I confirm that it is on cool mode. Warm air comes out even on the absolute coldest setting. I have to turn it off and use the manual reset button on the plug to get it to work properly. The problem started after the unit iced up one night and it hasn't worked right since. Is there any way to fix this or am I gonna have to get a new AC?


If after reset the A/C cools then the fault seems related to the thermostat or the cut off pressure switch or load cut off.\012However is there is no cooling at all the compressor and the gas pressure- check for leak if gas is absent.- must be ... LG ZW6500R Air Conditioner

Sharp AF-R1108X Thru-Wall/Window Air Conditioner was working fine all summer. The past 2 days were extremely hot out. the unit was working around the clock. the unit was in low cool and keeping up fine. Then it started making beeping noises and going into energy saving mode and cycling the unit on and off constantly and would not allow me to turn it off by using the selector button. I had to unplug the unit to turn it off. I left it off for about ten min. hoping it would reset it self. I turned


... Sharp AF-R1108X Air Conditioner

I have a window unit i just put in it is one year old and has not been used this summer it is only blowing room temp air and the it is on the cool setting and willl only work on high settign and auto i tried the reset button but the compressor still isn kicking on to get the freon in the unit working


If the unit is stored in any position *other* than the intended, normal operating position, the unit will not run correctly.Cooling appliances with compressors for refrigerants such as A/C units, refrigerators, freezers, etc., whenever mo ... Air Conditioners

Have a Haier HWR05XCB air conditioner window unit that has been sitting in the garage for a few years. I cleaned it up for use in a room and plugged it in and nothing but Zeros on the digital display (00) only for about 1 second, then absolutely nothing, power button does not work. It does this every time I plug it in, I have tried several different outlets. No evidence of anything burned up or otherwise wrong from visual inspection. Is there a reset button somewhere on this unit?


... Haier Preference Plus HWR06XCA Air Conditioner

Fedders window model A6Y12F2B "New Unit",,only 10 days in use! Just stopped working No Power To Master Panel Air Conditioner Not Working Fuse Panel/Breaker ok,Outlet ok,,power to plug ok(lights up) Reset button on plug functions normally Master Panel is dead, will not light up, non functioning controls


Take it back to the store. Manufacture defect if it died after only 10 days. Attempting repair or disassembly will probably void warranty. ... Fedders Air Conditioners

I have ventless natural gas heater , u can lit the pilot , but when u let up off the button the pilot goes out . have replaced thermocouple the same problem pilot will not stay lit. have also used air compresser blew it out ,stillwill not work is there adjustment screw on the gas valve or reset button on the gas valve .


When you light the pilot, hold the button in about 1 minute to satisfy the thermocouple. Once the thermocouple is hot and satisfied, turn the gas to "ON". You may have to extend the time a bit, but 1 minute is usually enough.Best regard ... Air Conditioners

I turned on my AC. The compressor sounded like it was straining and the fan wouldn't go on, then compressor went off. But the green powwer light was still on on the plug. I turned it off, unplugged it. Started it up again after about 4 minutes. Same thing. I used the reset button. Same thing. It worked just fine the other day! What's wrong?


I am guessing it is a window or wall unit right? not central AC? If thats the case, how old is it? New? can u return it? if not, if its older than 4 or 5 years, trash it and get a new one! If the fan isnt working after a few seconds or minutes the co ... Panasonic CW-XC125HU Air Conditioner

Maytag M6Y12F2A-E Power Cord does not work properly. When reset button is pushed nothing happens. If I hold it down for a few minutes the light flashes green. Unit does not come on. Please help me figure out what is wrong with unit. Can the power cord be replaced and if it can, where can I find the part.


... Maytag M6Y12F2A Air Conditioner

Model FC24B3XN1H. Modulating Echelon 60k btu. Fan runs constantly but no heat. Was installed 9/09. When turn thermostat off, fan still runs, have to shut off at furnace. It has never been a hot heat, installer said that is normal?? Used air couple days this week, was fine. We then turned furn off at thermostat as it was not needed. Turned heat on late yesterday afternoon & problem started. Left furn power off for about 15 minutes, but would not reset. Easy solve?? Is it supposed to be a 'cool' h


Hi,The fan running constant and the unit not firing is usually an indication that the high limit reset has tripped. And yes... these furnaces will run a cooler air... that is one way they get better efficiency...Also the ... Coleman Air Conditioners

Hello I have Sharp Air con/Heating AY-XPM9FR with a floor/wall unit and a higher wall unit that are supposed to work in conjunction with each other. I have never had any problems until we had a power cut and now the timer light on both units are flashing and I can't get the units to come on and heat (it's cold!!) I have the manual and have tried to reset the timers using the remote control but still no good.


Hi Helen, i want to know the age of your Sharp Air con/Heating system. If its more than 1 year and you using it regular basic , then i suggest you change the battery or the remote control first then try . If the same thing happens then follow the ins ... Air Conditioners

I have a AMANA PTh153B50AE (PTAC unit). The air conditioner works fine. It is when I turn on my heater and it does not get warm. It just blows cold air. I have looked at the board and it appears that there are no bad spots on the board from where it had burnt. It appears that it may have a manual heater reset button. I am not sure if that will work but I can;t find the reset button. I am wondering if my heat pump has gone bad. Any help would be appreciated. Thank you.


I have the same problem, and I found the manual reset inside the unit. Turn the power off, and unplug the unit. Remove the outer cover of the unit ( inside cover ) , and remove the 2 screws holding the " wire mesh " in the front of the cover. Pul ... Amana PTH153B50AE Air Conditioner

My Rudd Achiever 10 ran on air setting flawlessly this summer. Now that I am using heat, I have a problem. I get heat into the house; however, the outside unit keeps shutting down after a few minutes of service and I keep having to walk outside to the unit to press the reset button. Can I troublehoot and fix this on my own?


The reset button usually is related to refrigerant pressures, and should be checked by an epa certified technician. ... Ruud UBHC Air Conditioner

My frigidaire air conditioner cord got wet while being used and now it will not turn on. the end of the cord has "test" and "reset" buttons on the side of where it plugs in to the wall. the test button does nothing. the reset button does nothing when pressed in all the way but when slowly releasing the button the light for power will come on and blink power to the air conditioner repeatedly every second. nothing will stay on for more than 1/2 of a second and the fan will not start up at all.


Hello\015\012I would have the cord replaced.The test and reset is a ground fault,or a saftey device.\015\012If its not working correctly then have it replaced ... Frigidaire FAC124 wall/Window Air Conditioner

I have kenMore window air conditioner model 70121 i bought last year it worked last year and when I when to use it this year I keeps tripping the rest button I have rest the button several times but


... Kenmore Slider/Casement Air Conditioner

Rudd furnace I have a RUDD furnace model UGPJ-07-NAMGR. It had stopped working, so I replaced the thermostat but it is not the thermostat. When I hold the furnace reset button, the furnace will fire according to the setting on thermostat(heat or fan). As soon as I let go of the reset button, the heater stops working. It does not matter what I do to the thernostat, the heater will not fire. I crossed the red and white wire but nothing happens. The heater is supposed to fire when I cross wire, ri


You have a safety limit switch that is either bad or needs to be manually reset. Some have little buttons between the two wires going to the switch that you can push to reset. If not they are automatic switchs then one is bad. You have to do an oh ... Ruud UBHC Air Conditioner

Problem with daewoo air conditioner, not working, reset button is on, when i press test button, is just make a noise, but air conditioner is not working


... Daewoo DWC-052C Air Conditioner

Unit worked last year has hardly been used kept in storage, the reset button does not seem to work-the reset button is in the electrical cord


... Haier 9000BTU Portable Air Conditioner

Cental air unit stopped working, I replaced the capacitor which had blown apart, but the unit does not restart. It works when I push in and hold the button on what I believe is the relay where the power comes into the panel of the unit. Is there another fuse or reset button that needs to be reset within the unit. Any suggestions? The model # is AC1BN036-A and it's from about 1995.


You shud test the relay with multimeter for any shorting out or restricions.\015\012locate it and test it, if it is not beeping or showing zero its defective and you gotta replace that relay if its good, well you gotta locate the shorting out i ... GE Air Conditioners

Delonghi pinguino PAC 250 U air conditiooner blows hot air. reset button must be constantly pressed in order to get normal cooling. also timer does not seem to be working


... DeLonghi PAC85 Portable Air Conditioner

My air conditioner will not turn on. (See below for a more detailed description.) I recently bought a used Kenmore Room Air Conditioner Model 580. 76129. It worked well for about a month (running almost continuously, usually on either energy saver or cool). About a week ago, I walked out of my room when the air conditioner was on, and it was off when I walked back in about an hour later. (The display was unlit, and it was not making noise.) The power button still does not work. The outlet


If you have a GFCI plug on A/C unit it may need to be reset at the plug. ... Kenmore 76129 Air Conditioner

Turned it on for the first time this year. After a few minutes it would stop working but all the light indicators are still on. I made sure that the energy saver is off, that is is getting the full 220 volts, and presst the test and reset buttons on the plug. No results. Unplugged it for a few minutes and tried again. Same deal -- would start and then stop working after a few minutes but also noticed a burned electrical smell. Could it be the capacitor or something?


Yes, it could very well be a burned capacitor or a burned wire from over heating, Best advice is to unplug the unit and do not attempt to use it, until it is repaired.To find an authorized service in your area, click on the link below. ... Friedrich Compact Programmable CP24N30 Air Conditioner

Frigidaire Model FAZ12HR2A Digital control pad buttons are non-responsive and air is not cold. If you reset the unit, all buttons work and you can adjust the temerature,unit runs fine and cold air is present. The temperature then appears to adjust itself (you hear beeps and the temperature increases). All LEDs are lit and control buttons are non-responsive.


My unit is making a weird sound and if you leave it on for two long you can start smelling a burning smell. Have you heard of this problem before? ... Frigidaire FAH086R1T Thru-Wall/Window Air Conditioner

GE room air conditioner control panel stopped working. The buttons on the control panel does not work and the remote stopped working also. I have use the power surge protector to cut the air conditioner on and off.


Check that your dip swtches are set right ... GE Built-In Room Air Heat Cool Air Conditioner

I have the Royal Sovereigh ARP-1400BLS, 1400ww. T/he ac turned on the first day I installed it and then after turning it off once, it would not come back on. I played w it for days making sure to leave it off for three minutes between each turn on. I floowed the direction for Power Plug Check: press the RESET button Insert the power plug in the electrical outlet Press the TESt button. If the circuit bresker is working you'll hear a clik (which I did usually hear) Press the RESET button


... Royal Sovereign Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific