What type of capacitor comes with a 5 ton Goodman Air conditioning unit model number CK60-1C


Answers :

The best way to know what size capacitor it needs is to look on the label of the fan motor itself. It will tell you the size it needs. Condenser fan motors get replaced all the time with different capacitors needed. If you cant find a label or its too weathered, try to find a model number on the fan motor and any local A/C supply store will be able to look it up. Hope this helps.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

What type of capacitor comes with a 5 ton Goodman Air conditioning unit model number CK60-1C


The best way to know what size capacitor it needs is to look on the label of the fan motor itself. It will tell you the size it needs. Condenser fan motors get replaced all the time with different capacitors needed. If you cant find a label or its to ... Goodman CKL60AR60 Air Conditioner

Trying to find what model type of capacitor was used in my Goodman Air Conditioning unit Model CK60-1C, serial number 9806465759


Contact Johnstone Supply either by phone or email ... Air Conditioners

I have a Goodman 2.0 model no. ck24-1B and would like to change it to a 2.5 Ton 13 SEER R-410A Air Conditioning Condensing Unit. My furnace is a Goodman model # GMS8, GDS8 or GHS8 are they compatible


If it is a 410a system now you would have to change orfice. if its a r22 system now no way. ... Goodman Air Conditioners

My thermostat doesn't make the little click noise when i know it should be turning the air conditioning unit on. I have a Carrier unit. And we had it on for 2 days, then all of a sudden it won't come on again It is a Carrier unit installed in 1990, but i can't find the model number


Open the thermostat and look for anything that may seem suspicious. Also, if you have a way of blowing air onto the thermostat's internal components, try doing so. There could be dust (or I've seen small insect) that could be trapped and preventing t ... Air Conditioners

Blower fan in the inside unit tries to turn on but wont. It can be turned manually and air conditioner comes on and runs fine. The " squirrel " cage spins completely freely and is not sticky or jammed. Is the motor bad or is it a run capacitor. Model number of inside unit is a49-15


\011Sound more like the cap, but if the motor is raging hot, it could be the motor, another thing it could is improper voltage although less likely. But Goodmans/ do have this weird fan relay issue were they just bite it some times. I wo ... Goodman Air Conditioners

Details I have a problem with a Goodman Model GSH130601AA, ( 5 Ton, 13 Seer heat pump) central air unit, installed 06/15/2006. (I know, I saw online reviews but unit was put in before I saw negative e


The fan motor is bad and needs replaced. Depending on how mechanically inclined you are, you can replace it yourself fairly easy, the hardest part being the fan blade without a hub puller. Just take your old one in with you to a local A/C supply stor ... Air Conditioners

Can a Goodman AC unit with a model number of a 24BTU-2 ton unit be upgraded to a 3 ton unit by changing the piston and the settings on the blower? They are also going to install a 3 ton compressor outside. Would this provide the same cooling capacity and performance of changing the actural HVAC unit to a 3 ton unit and would Goodman give me directions stating as much?


They would need to change the coil indoors to a 3 ton. If the blower speed can be increased it should be fine. ... Air Conditioners

How many tons is a Goodman Central Air Unit with Model Number CKL30-IE?


That is a 2.5 ton system. The model numbers are as indicated:24- 2 ton.30- 2.5 ton.36- 3 ton.42- 3.5 ton.48- 4 ton. 60- 5 ton. Hope this answers your question! ... Goodman CKL60AR60 Air Conditioner

My Goodman air handler RELAY, ELECTRONIC BLOWER TIME DELAY makes a clicking noise 4 or 5 five cycles (about 10+ Sec delay ) before the squirrel cage fan will come/stay on. I have reset the unit by switch it off for 5 minutes then back on and it worked for a week but now it makes the outside compressor go on and off the same number of cycles before it comes on. Do I need a new board or can the capacitor cause this problem? Help it's hot in Phoenix!


When this happens turn off power and feel motor if hot capicitor i dont think this board cost much but if it does you can get a fan sequenseing stack switch to repace the board with ... Air Conditioners

I have a goodman 5 ton a/c model gsc130601bc, it isn't cooling, keeps tripping main 60 amp breaker, blower is running at air handler. Tstat is calling for cool and contactor Is pulled in, it has a service breaker close to unit. I checked 80/5mfd capacitor with field meter, checks 79.5/4.9 mfd


... Air Conditioners

The other day. my American standard air conditioning unit (Allegiance 10 model 7A0030A100A0) would not stop running. The furnace was not running, yet the air conditioning unit was on. I could see condensation on the line running to the furnace. The next day the unit would not even start running. I shut it down, tried it the next morning and the unit ran for about 30 sec and stopped. Could the capacitor need replacing?


Yes, that might be the problem but in this case you need a qualified technician to test system and find real cause of problem. ... Air Conditioners

I have a Goodman air and heating unit model#gsc130601bc and the problem is the unit comes on but the fan does not, also the unit gets hot and no cool air is coming out of vents in the house. What can I do to fix it?


... Air Conditioners

Evaporator Coil I have a Goodman A/C system (2 systems...1 for 1st floor, 1 for 2nd floor). The one for downstairs is 3.5 ton. the one for 2nd floor is 3 ton unit. Installed when house was built 5 1/2 years ago. The upstairs unit has had the evap coil replaced once, and repaired a leak once - 6 months ago. The downstairs unit has had the evap coil replaced twice -and is now leaking again. Model for the air handler is ARUF042-00A-1A. Goodman part# for the coil is P140142. Can I replace this coil


Yes, just count how many pins per inch and replace with the same number of pins per inch. ... Air Conditioners

I have a Goodman Model number AR24-1 unit and the blower moter will not start with it turned on to fan or cool or heat. I have checked the thermostat and the unit runs outside. Just no blower. Can I jump the blower motor as I replaced the capacitor today. Hear are some numbers that may help. Part Number #15212-50 Volt 208/240 Amp 1.5 HP 1/5 No heat Kit It has a Goodman switch board # B1370735 that I can check with my meter if needed. I have checked the thermostat in the attic also. Seems like


... Air Conditioners

I have an Interthem / Nordyne heat pump model E2EB-015HA. On the outside unit the fan does not turn on when the unit comes on. If I spin the fan it will come on and will run well. With the unit off the fan blades spin easily. I suspect the capacitor, but can not find a part number for it. The capacitor itself is rusty and any writing is unreadable. Please help.


Not sure what Country you're in but the Part No for the Run Capacitor is 1499-4461 and can be purchased from the following link.\015\012\015\012htt ... Air Conditioners

My air conditioning unit stop working (outside unit). When I turn the unit I notice a buzzz sound comming from the unit. I have pressed the reset button on the unit to see it that would help but nothing happend. I check to see if there was electricity with a voltemeter and the unit is getting current all the way to the capacitor. I turned the power off to the unit to check if the capacitor had a charge and it did. What other things should I be checking? Also, the fand do not turn on! model numbe


Hi, what is happening is, you have power to the outdoor unit. I am glad you have a volt meter. This system is a split unit,condenser outside and indoor unit. This is what you need to check, and what the buzzing is, and why the fan and compressor will ... Ruud UAMB Air Conditioner

I have a 4-ton Frigidfaire air conditioning unit on my 2400 square foot home, but I am not receiving the cooling I should receive. My split system model is #: FT4BF-048K. My air handlers Model is #:B4VM-X48K-C. I suspect my problem may be duct size. What should be the sizes of supply and return ducts on this unit? Phone 941-776-9270.


Hi, the ducts are 18" round at the beginning and branch out to smaller sizes for other rooms. 10" for living areas, 8" for bedroom, down to 6" for bathrooms if they have them.If this unit was just installed, I would recommend getting the contractor o ... Frigidaire Air Conditioners

Looking for freon capacity for 5 ton goodman package unit, cannot read serial or model number.. unit is 1998-2000 model ,, we just replaced the accumulator and we are not sure how much freon to put in.. Goodman offers no help whatsoever.


Check low side which is the bigger of the two, make sure you tighten the hose good. your reading should be 65 psig.If not add refrigerant/r22 . if r410a 110 to 115. ... Goodman GPC1342H21A Air Conditioner

Goodman CK60-1C model central AC unit blwing hot air


I least you know where the problem is....Something got bent or a wire got disconnected in the thermostat. If all fails replace it. ... Goodman CKL60AR60 Air Conditioner

We installed a 4 ton downflow coleman air handler with evap coil Model number 1854s2m we did not change out the outside unit. the outside unit is a 13 year old 3 1/2 ton intertherm condenser the system is only generating a 10 degree delta T. My question is, this coil came with a factory TXV I am trying to find out is this a 10 seer or 13 seer coil is it compatable with the outside unit.


You have a missmatched system, for it to work try removing the orfice on the high side txv it is not allowing the evaperator coil to fill with refrigerant properly coleman and intertherm dont like each other since they control a large market in the ... Air Conditioners

My goodman central air unit quit working after a storm. The circuit breaker is not blown. The furnace fan kicks on when ac is turned on at the thermostat but unit outside does not operate. Is there an internal fuse or capacitor on outside unit. Thank you very much, Bryan Model CKL36-IF Goodman


1 posible cause.the thermostat supplies 24 volts to the outside unit to control the contactor if you hear a ligth huming on the outside unit this is the being activated. if this is the case then\015\012\015\012 check to see if any ants are in ... Goodman Air Conditioners

Hello , this is Bobby and I have a Coleman Mach rooftop air conditioning unit Model # 8335B8964 when I turn on the unit ,it throws the circuit breaker . I have replaced the starting capacitor and the running capacitor for the compressor, the fan runs ok.Is there a circuit board for this particular unit?


Here's a link to a service manual, with step by step tests to determine whats wrong. I'm thinking compressor shot, but this should confirm, and or help you determine for yourself. Be careful with those capacitors eh !! Read warning in service manual. ... Coleman Mach 15 Air Conditioner

I have an Amana a/c unit and the compressor outside keeps stopping however the fan goes on. The a/c service guys have been to my house 3 times and the wires each time were burnt. The last time they change the capacitor and and new heavier guage wires and it lasted for about a month. When trying to turn iton now I am back to the same situation. Do you think I should I go for a compressor or change the unit ? It is a 4 ton model BBC60a2A and the outside unit model number is RCE42A2A . Thanks


... Amana PTH123B35AJ Air Conditioner

I have a central air conditioning unit in the apartment where I live. It is a split unit - somewhere outside is my outdoor unit (and everybody elses too). Anyway I seem to get way too much humidity in my apartment. The air conditioner I suspect is 15 or 20 years old or more. The label on the indoor part is almost unreadable. Carrier is the maker. The model might be 40AC02450052. There are also other numbers 40AC901190 ? or 40709010 ? Can anyone identify what I have? I would like to know how old


The humidity problem is from the condesation drain. It is more than likely to be clogged up keeping water in the condensation pan causing the humidity problem. This can be cured by a wet vac put onto the outside drain for the inside condensation pa ... Carrier 38CKC030 Air Conditioner

Trane split air conditioning -XIL 14 MODEL- no cooling , condenser unit blowing cool air, compressor comes on once after start up and then dont't come on after that , condenser fan working


Shot of freon or loose signal wire between condenser and wall unit ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.2616 seconds