Having problems with your Air Conditioners ?

DELONGHI Pinguino PAC CT90, has been throughouly cleaned, but still no cold air blowing out? I just need to know what needs to be done to it when I take it to a local repair shop so I know what to ask for please.


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

DELONGHI Pinguino PAC CT90, has been throughouly cleaned, but still no cold air blowing out? I just need to know what needs to be done to it when I take it to a local repair shop so I know what to ask for please.


... DeLonghi Pinguino PACL90 Portable Air Conditioner

Ok So We Bought This. But We Have A Problem Does It Take Water Or Not? Thats What I Need To Know! Please Help!


The DeLonghi PACA120E Portable Air Conditioner quickly cools rooms up to 400 square feet and comes equipped with several functions that make operation easy and low maintenance. Its 3 operating modes are supplemented with no-drip technology, an adjust ... DeLonghi PAC A120E 12000 BTU Portable Air Conditioner

I require information on Glow worm flicker flame gas fire. Manual has been lost. I need to know the output for this fire before having cavity wall insulation done. Can you help please.


Glowworm Flickerflame G.C. No. 32 314 23. 3.36KW (11465 Btu/h) ... Air Conditioners

I need a selector switch for a Frigidaire AC model# fal103s1a1, I've tried everything to get a part number for that switch.I know that I can buy it from my local distributer for $70,but I was hoping to find it somewhere cheaper.Can you please help me. Thanks, [email protected]


... Frigidaire FAL103K1 Air Conditioner

I believe that one of my heating element is bad. So I will change both elements. I have done this before, but for this particular model I needed to know the part # or description before I take them out. Is there a diagraham that I could see and get the part # or description to make sure I have the correct parts before I start. RUDD Model # PE52-2T 50 Gallon Water heater. Thanks Buddy


On this water heater there are 2- 240 volt 4500 watt screw in elements. I use an 1 1/2" socket and wrench to remove them. Of course always turn off breaker and check the heater to make sure there is no electricity. here is a link to help you with mor ... Ruud Air Conditioners

I have a rinnai gas heater ultima inbuilt (i think it is called a high efficiency 30 model) which is almost 6 years old the local plumber says the timer is faulty & a new control panel is neede however he can not locate a unit, can you please let me know where i can get one as the unit has hardly been used since installation & otherwise is in perfect condition thanks Ray


You can try www.sdsmarket.com/rinnai-parts-lists-s/750.htm. Thank you. ... Rinnai Air Conditioners

I have a carrier model pv 48nboo6. It worked fine intil I had it checked and they said the the evaporator coil and expansion valve needed to be changed out, which was done under warranty. This was done and it now sweats so much it has shut down at times when the pan fills up. They have put in new dry insulation and slowed the fan but it still sweats. What needs to be done they do not seam to know.


Hi,Actually slowing down the fan will only make the condensation problem worse....they should speed the fan up, not slow it down...you need MORE air flow....also the expansion valve may need to be adjusted, but many A/C techs do not know how to ... Air Conditioners

We have a honeywell ct85 ( the round one) and we accidently broke it.. i need to buy a new one and install it but i dont know how.. i tried to take it off the wall and saw 4 wires..two red ones, one brown, and one green.. need help and explanationof the the installation process for this? does it take a long time and is it hard to do?


Do not worry about the colors, rather the terminal markings.Usually R_Rh will get Red G will get green the may used brown on Y ... Honeywell Air Conditioners

My motor for my Goodman CK36-1B condenser unit is beginning to overheat and stop in its tracks. I know I need to replace it, but the a/c place is charging 350 dollars for the part alone...that and labor is way beyond my means. I can get a "universal motor" and capacitor for it for $130, and think I might be able to install it myself, as I'm very handy with those kinds of things. However, I've never done it before...is there anything I need to know before attempting to do this on my own?


Yes....shut the power off.Just kidding.The old capacitor can hold a charge even after the power is off.be careful.make sure the motors are same hp and rpm.the universal may also have a rain plug that needs moved to the back face.besides that,pretty s ... Goodman Air Conditioners

I need to know the same thing as asked by Alan in Aug. I have a coleman thermostate 6703-340 and need to know which three wires go to which 3 termimals.Thank-you, Frank


... Coleman Mach 15 Air Conditioner

I have an amana cr2-1 model outdoor air conditioner. We just bought the house and it did not come with a manual. I was wondering what we need to do to get it ready for the season. I have never had an air conditioner before, so I don't know anything about them. Do I need to do anything with the outside unit? Are there parts inside my house I need to do something with? Are there filters, or are they the same as the funace filters? I ask this because it looks like it is tied in with my furna


... Amana Air Conditioners

Boiler unit My problem is: I have recently renovated my house. In doing so i removed one of the raditors. I had to drain out the system to be able to take out the rad. Now i have to refill it... i am totally lost. what i do know is that i wll have to bleed out the air as the water rushes through to all the different rads.... what do i need to know about doing this.also how does the expansion tank come into play I am seeking answers on how safely refill my system so i can once again have heat. th


In a hydronic system for heating you must insure that the pressure on the boiler is maintained during the process of bleeding off the air from the system. There is a regulator for the water make-up to the system which normally maintains 12 PSI with t ... Air Conditioners

Majestic dvr36rn I was told by the company who supplied & installed my 11 yr old fireplace that the valve (gas valve honeywell -nat) part #10001782 ... Needs to be replaced, however, they told me part is no longer avail & in order to repair, they need to replace it with a conversion kit from Paris, Kentucky - they said it would take btwn 3 wks & 6 mos. to get part!!! AND itis expensive! I wonder if anyone knows where I can get this part.


... Air Conditioners

Would like to know if I will be able to install a Honeywell RTH7500D1031 with my gravity furnace. I have upload pictures of my current thermostat and furnace. Please let me know if you need more information about my equipment. Pictures of them/furnace http://imgur.com/a/uO6kw


If the thermostat is battery powered you are ok just hook up red and white terminals it doesnt matter which one goes where if it is heat only ... Honeywell Digital Programable Thermostat

A/C Model: FAC107P1A My unit is not putting out cold air. The temp wire is not touching the coils. I've cleaned the filter, and behind it. What do you think the problem is? What needs to be done to fix the problem? Could it need Freon? What type of Freon does it take? I have a certified person to put it in, but I have to get the Freon myself. Is it a sealed unit? Will it be obvious to him, where to put in the Freon? He said that he's not sure, but hasn't looked at my unit yet. I have to g


Hello, if the filter, evap, coil, condenser coil are clean then most likely the unit if low on freon. most window units take either r 134a or r -22, it will say on the data plate on the unit. To charge freon into the unit a piercing valve will need t ... Frigidaire FAC107P1A Wall/Window Air Conditioner

Aircon regasing hi there i am in the uk. i bought a winnebago brave 1993 . the rooftop aircon unit a coleman tsr is not blowing cold, had it checked and everything is working fine, the fridge engineer says it needs regasing. he needs to know what type of gas and how much in grams. he stocks R600A AND R134,will these do please? regards rob


There is a specification plate on the base of the unit. It will have the refrigerant type and quantity listed. The leak should be found and repaired before re-charging with refrigerant.1993 model could be r-12,r-22 or r-134a. ... Coleman Air Conditioners

I have a ge model # asw12als1 12000btu room a/c.i think my thermostat is getting hung up. and wont stop running. there is a electronic board on the unit. this room a/c is just a year old. any suggestions on how to fix it? i took the front cover off. cleaned the evaporator and followed the thermostat back to board. very small space to work with. need to know if i need a new thermostat. temp in room going down to 60. even with thermostat set at 86. help please???????


... Air Conditioners

My condenser will not come on out side. When i take the side panel off. i hear a buzz/ hum like there is power that is not working correctly. the wires that i can see visually connected look corroded but I dont know if it is the wires that need replacing or if the connector that the wires are coming from or the silver cylinder box that some of the wires are running to need replacing?


The buzz you hear is most likely the contactor that brings the compressor on...the capacitor would be the most likely bad part as they seem to fail on regular basis...are there any burned wires that could be burned in two? the capacitor is the round ... Goodman CLQ36AR49 Air Conditioner

Warm air I have a chilled water system with 5 cassettes, basically the air off is not chilled. It is in a shopping centre with no complaintd, as far as I know, from any other shop. i am not familiar with chilled water systems and wonder if any one could let me have a schematic showing component s neede and their positions. Regards Peter Burnett


A mechanical drawing of the system before installation (assuming an architect drew and approved the plans) should be at the malls office. Also the building inspectors office may have a copy of them. The basics of chilled water are not too ... Air Conditioners

Need to know what Carrier air handler will work with a 24ana760a003 Infinity? Please help


I am a Carrier Dealer. Here is your info 1 Model FE4a or FE5a The 5 is upflow only where the 4 is multi positional. F is fan coil E is Infinity A is series N is the voltage. By the way I have the Infinity series in my home it is quiet and very low c ... Air Conditioners

Need to know what BTU a king post air conditioner RAE-007 is please


... King Post Air Conditioners

I need to know hoe to correctly onsert the energy cell. my Braun Cordless Styler - Butane Curling Iron is not heating up. please advise.


... Air Conditioners

I have a wall king commerical heat pump by Intertherm model PWYO48BAVAA, appliance # A000934067. I live in an area where locals are not familiar with this pump and would like to install. I need to locate schematic or a book for this unit. I am installing in my hobby shop


... Intertherm Air Conditioners

1999 chevy cavalier, cold air in the vents it just will not blow from vents. the repair shop said need to take out dash to get to possible issue? thinks may be leaves and feathers. isnt there an easier way ( and cheaper) to do that?


Sounds like a vacuum door, check the vacuum hoses from the manifold back to the controller on the blend doors ... Air Conditioners

My Sharp CVP-12LX air conditioner keeps shutting off with the lights blinking. Usually this means the unit needs to be drained of water, but I have already done this. I reset the remote control and the unit's circut breaker but don't know what else to try. Suggestions would be greatly appreciated.


Hi there,\012Well,  It is a reminder to check the filter may be it needs cleaning. Once you have checked/cleaned the filter and reinstalled it, then reset it again using the remote control....Hope this resolves the issue.... ... Sharp CVP12LX Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific