Having problems with your Air Conditioners ?

Purchased a fedders a/c 18000 unit still under warranty. called the 800# they said company had filed bankruptcy and were not responsible for repairs. 350$ mistake. Fan runs too slow for unit to kick in. Fan will pick up speed some times when you turn it on, will start to blow cold air but only runs for a couple of minutes before fan stops turning.


Answers :

Check the capacitor for the fan motor. You can do that with a multimeter with the capacitor test function or if the capacitor looks swollen then it is probably bad. Also, make sure the fan rotates freely by hand. Let me know if you need more help.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Purchased a fedders a/c 18000 unit still under warranty. called the 800# they said company had filed bankruptcy and were not responsible for repairs. 350$ mistake. Fan runs too slow for unit to kick in. Fan will pick up speed some times when you turn it on, will start to blow cold air but only runs for a couple of minutes before fan stops turning.


Check the capacitor for the fan motor. You can do that with a multimeter with the capacitor test function or if the capacitor looks swollen then it is probably bad. Also, make sure the fan rotates freely by hand. Let me know if you need more help. ... Fedders 12,000/10,200 BTU Heat/Cool Room Air Conditioner - White

RV ac fan runs backwards (blows out air on top of RV.) Runs correctly sometimes but after it satisfies and clicks off when it kicks back on, it runs backwards. The only thing that will turn it back around is to turn off unit and wait for around 30 minutes and turn back on. (won't reverse motion very quickly) Spoke to Coleman expert and was told it is the fan capacitor. Need instructions to identify and change the capacitor. Would like to fix myself since this will be the 3rd time to have it i


Hi, this is strange as I have never heard of this either!!! The capacitor is located by the motor and sometimes clamped to the motor. They can be the shape of a very small can, oval 3" tall with 2 leads on top with wires coming off the terminals. It ... Coleman Mach III Air Conditioner

SAME PROBLEMS 18k btu mini-split sys turn on blowing cold air for 3 mins, then turns warm for 3 mins then shuts down however the run lite blinks at 4 times intervals. outdoor unit fan alway runs at slow speed, even at start up. cleaning outdoor fan cleaning dont help. whats next? maybe the caps? thanks mike (us navy) at [email protected] in norfolk,va FAN MOVES FREELY, EVEN BY WIND BLOWN.


Glad to hear the issue is resolved.\015\012\015\012With regards. ... Air Conditioners

The fan on the Ruud furnice unit runs all the time but the Ruud ac unit is not kicking on . I know nothing about any of this but would like some Ideas what I might check. I went outside and could not find any kind of breaker on the outside unit. I do have a breaker inside and I turned it off and waited then turned it back on ..no change...


Some Ruuds have a red rubber cap reset button on the bottom of the unit or inside. Usually the fan quits and trips the switch. Or look at the metal run cap with 3 leads on it, if it looks bulged(concave on top) and not flat and sunk in, replace tha ... Ruud Central System Air Conditioner

I have the MR36TQY3f outdoor unit with 2 MW09Y3FM units and 1 MW12Y3FM indoor units! The MW12.. works great and one of the MW9... works great! When I run the 2nd MW9 only (other MW9 & MW12 off)..... the outdoor unit compressor or fan does not come on! If I run all units then ... compressor kicks on runs great, fan runs... lines get cold on the 2 good units ... nothing on 3rd unit... then I turn 2 good units off....and it sounds like the compressor kicks off and the fan will continue to run reall


After looking at the manual for the units, I believe that the system is having trouble with the number of units that you have linked. Here is a portion of the manual about multi system operation>Also link to manual:http://www.fri ... Friedrich MR36TQY3F Split System Air Conditioner

I have an Amana central air/heat unit. Model PHCB10C1 Serial # A040900070 Manufacture # P1219409C, Cat # 81K95. The problem I am haveing is the unit will not kick in(heat). When I turned off the main pwer and let off for about a hour and turned back on the unit ran fine for a couple days. Now the unit will not kick in at all even after turning the main power off and on to reset the unit. I have a brand nre thermostat in the house. When I turn the fan from auto to on the fan runs and blows out


... Amana Air Conditioners

Hi guys, I try to solve this problem i have with my AC unit American Standard YCC048F. Short: The heating and cooling are ok, the only problem is the fan doesn't turn off even if heat or cool turns off. Some times even if i put the thermostat is on off the fan starts running. I try to find a relay for the fan but i don't know what can be the problem. Please help, for now i am switching on/off the unit to have it run. Thank you. Costi


If the unit has printed circuit board the relay maybe in it which has probably welded contacts, must change the pcb then or try tapping it, it might help or even, try off and on power at circuit breaker it migt reset the pcb. ... Air Conditioners

I have an ultra sx90 unit. the compressor kicks on just fine and runs for about 10 seconds then the fan motor goes to kick in and it starts then stops about 3 to 4 times before it finally stas on. then when compressor stops the fan motor continues to run for about 20 sec then kicks off and on 4 or 5 times.


Hi,\015\012That fan is running off of either a pressure or temperature sensor....could be either one...\015\012bottom line is that this switch is going bad and the "deadband" is too small causing the unit to cycle too often...\015\0 ... Air Conditioners

I have a Goodman package unit model no.PGB030075-1 REV A. Noticed the fan was running all the time but compressor wouldn't kick on when I turned the AC on. Noticed the contactor relay was burned u


... Mitsubishi MS12TN Air Conditioner

I have a goodman gsc13 ac unit about 4 year old. When the temp gets around 90 or above outside the fan on the unit starts but the compressor does not. I had service check it out but that day they were here it was in the 80's and it worked fine. I replace the thermostat to make sure that wasn't the problem. Interesting if I turn the unit off at the thermostat and wait 15 minutes and turn it back on it will run fine. But the next time it tries to turn on automaitcally it will just be the fan o


The hum you hear is the 24v transformer which is powered form the air handler inside have you tried a hard start kit or had cap checked ... Air Conditioners

I have a 1993 Model SRHF48U01A (The 0 might be a O (zero) When the thermostat calls for cooling, the inside unit (fan) starts up and continues to run but the outside unit wants to start (it comes on for a second and then trips the breaker that is located behind the outside unit. I can turn the breakers off that are inside the house and let them stay off for a short time and then reset the outside breaker and then turn the inside breakers on and the unit starts and continues to run until the te


Well the trouble is surely at the compressor side. Dont know what kind of repair man you invited. He should have atleast diagnosed the problem. Following can be the causes\015\012\015\0121. Capacitor is slightly faulty (As you said). If t ... Amana Air Conditioners

Goodman outdoor a/c unit top fan stopped working while the family was away from home and now the compressor will not turn on. Only thing happening when a/c turned on inside is the indoor unit kicks on and the outdoor top fan begins humming and getting very hot to touch. Unit is only 5-7 years old. It is a Goodman CKL42-1L. Please, anyone with suggestions is appreciated. Definetly do not have money to replace the entire unit at this time.


... Air Conditioners

My unit is 4 years old. I always turn it off when I leave for work in the am and turn it back on when I get home in the pm. Last night I turned it on at 7:30pm. When I went to the front of the house about 45 minutes later, I noticed the unit outside was trying to turn on but would immediately turn off. I checked the breakers in the garage, turned them off and back on but still had the same problem. The fan inside the house is running but unit outside will not kick on. I looked for a magic


It could be a few things.. It could be the capacitor - which the most economical to replace first..\015\012\015\012If you are not really very mechanically inclined - get a trained pro to come out.. It is very dag ... Air Conditioners

Unit runs but will not cool. Fanruns fine but when turn dial to cool the compressor kicks in for about a second or two the kicks out. Fan works on cool but it will not produce cool air at any temp setting. I have cleaned filter and removed cometic facing and vacuumed the coil face. It was pretty dirty but after all that still would not cool, Unit is installed in a RV and power is provided from house. Gen4erator is also available for power. Unit is difficult to remove from RV and space to get at


You may need to install a hardstart kit if you can get to the compressor.\012go to your nearest appliance parts store to get the part and the instructions are usually on it. If not ask the parts man.\012\012If this was helpful pleas ... Air Conditioners

I have a york hvac system that is 5 years old. I have the thermostat set at 74 and when it turns on only the fan runs circulating the existing air in the house about 20 percent of the time. The ac works great when it is running but i'm wondering why it doesn't always come on. Just replaced the thermostat thinking that was the problem but it did not help. Sometimes after the fan runs for a half hour or so the ac will finally kick in and start blowing cold air. The lines are not frozen at a


It sounds to me like you have a delay on start timer on the compressor that possibly is starting to fail or someone may have adjusted the time band up on it. I myself would remove it and install a delay on break timer and a 5 minute setting would be ... Air Conditioners

UNIT RUNS AN EXCESSIVE AMOUNT OF TIME AND AIR IS COOL NOT COLD COMING OUT OF VENTS CARRIER 58DLA / 58DLX CENTRAL AC FAN AND COMPRESSOR ARE OPERATING BLOWER IS WORKING UNIT IS TURNED ON TO AC TEMP SET AT 76 UNIT RUNNING FOR OVER AN HOUR OUTSIDE TEMP 80 THERMOSTAT REGISTERING 77


DOES THE HOUSE FEEL DRIER IF IT IS 80 OUTSIDE WITH ALOT OF HUMIDITY THE UNIT WILL RUN FOR A LONG TIME TO REMOVE THE MOISTURE(HUMIDITY) OUT OF THE HOUSE BEFORE TEMP DROPS DRAMATICALLY IS THERE WATER COMING OUT OF THE DRAIN PIPE OUTSIDE ... Carrier Air Conditioners

I have an old RUUD central AC unit that started blowing hot air. I set the thermostat to off and set the temp gage higher than air temp to turn the unit off and save money, but inside blower unit runs constantly. I'm trying to save money to have it serviced, but noticed my electric bill was higher that last month when the ac was working. The bill was about 4 times higher than the winter when ac is off and the gas heat kicks in. Can the blower running constantly cause this power usage and what is


HelloOkay did you check your thermostat to see if you have the fan switch on auto? The switch must be on auto or the fan will continue to run. If the thermostat fan switch is on auto then there is a malfunction in the thermostat probably ... Air Conditioners

Turn the unit on, the fan runs, and when the compressor tries to start the fan slows down and the compressor will not run. After a few seconds the fan speeds back up. I put an amp meter on the compressor lead and when it tried to start I registeres 41 amps. Is this a compressor or capacitor problem?


Sounds like you have a bad capacitor, if it's not tripping the breaker it doesn't sound like the compressor is drawing LRA unless the breaker is oversized for the condenser. ... Air Conditioners

Kf-34gw/c wall unit, green run light blicks 4 times than ac shuts down and condenser fan stops turning. Cant get the unit to stay on for more than 5 minutes at a time


... Air Conditioners

The unit does not stay running but I noticed that the fan motor is not comming on but I can free spin the motor. Is the motor the problem or does the unit run then the motor kicks on after a period of time?


It could be the motor, but I would make sure it's getting power first. Then I would check the capacitor. Turn the power off before checking the capacitor. If the capacitor is good, use an ohmmeter to check out the fan motor. ... Dometic Rooftop RV Air Conditioner

Intertherm Electric Furnace in mobile home Model# MRAC 2317 SN - 79JE0501 Question: The blower stays running all the time. I have to turn the main breaker off to turn the blower off. The unit is heating when it is running. I have replaced the thermostat about 3 years ago in the summer when I had a AC problem. Would the fan switch on the furnace possibly be the problem? It has an auto & on position on the switch. It clicks when you switch to the on position but does not click when you put i


... Intertherm Air Conditioners

Air conditioning unit not running but fan keeps running even though thermostat is turned to off, auto, and temp set to highest position 90degrees. 3 amp fuse keeps blowing on the circuit board in the blower compartment. I replaced it 3 times then installed a new thermostat. no change. I can usually figure it out if I got a little input or direction. Any help would be deeply appreciated. I would much rather have a trained expert easily repair my hvac unit but I can only call the professionals in


If the fuse is blowing then this is generally indicative of a short in the low voltage wiring, isolate the wires on the thermostat and the unit ends, use an ohmmeter to verify that there is no path for continuity with no wires touching, if there is t ... Air Conditioners

I have a Kenmore window air conditioner unit. It turns on, the motor runs, but the fan does not turn on, and the front gets cold to the touch. I have taken it out a couple times and cleaned it and that has no affect. It was jolted and then ran for a day and a half, then quit. Is there anything I can do to get it back running? Thanks for your input!


99% of the time when a motor just hums on a window A/C is the motor itself thats bad. Jump to test if work fine, if not, here, for your model you can order parts replacement: ... Kenmore Air Conditioners

I'm having a problem with my heating and air system, my heat only works on emergency heat ( and run 24/7) if i turn it to regular heat it only blows cold air. i dont think my outside unit fan is turning( i could be wrong about this one) how can i fix this problem so i dont have to run my emergency heat all the time


If your Heatpump's fan isn't running but your compressor is, your fan motor is out. If nothings happening at all ensure your getting power to heatpump (ex: breaker tripped, fuses blown on outside power switch, or fuses blown in breaker box?) ... Air Conditioners

AC UNIT RUNS AND ALL OF THE SUDDEN FAN STOPS AND COMPRESSOR WILL RUN A LITTLE WHILE AND STOP. THEN FAN STARTS AND COMPRESSOR KICKS IN AS NORMAL. ONLY HAPPENED A FEW TIMES, BUT I DONT WANT TO WAIT UNTIL IT DOESNT WORK AT ALL. ITS A 15000 BTU COLEMAN. COULD THIS BE A CAPACITOR PROBLEM???


Check the condensor unit. May be dusty. Clean it. If still problem replace capacitor. ... Coleman 15000 Btu Rv Roof Air Conditioner With Heat