Our Fedders through-wall unit (A2T10F2B) turns on, and the fan works at various speeds, but the unit does not cool. What should we do?


Answers :

Hi
\015\012\015\012
\015\012\015\012
\015\012\015\012Thanks\015\012for using FixYa. The cause of not cooling can be Drain, Sensor or Electric\015\012Control might have gone bad. First of all you’ll need to check that the condensation\015\012drain is not clogged and is working fine. Also check that the thermostat sensor\015\012behind the control panel has not gone bad. The sensor should not be touching\015\012the coil but instead it should be near to it. Please check and adjust it. The\015\012thermostat sensor measures the temperature of incoming air into the evaporative\015\012coil. Due to malfunction of the sensor the AC will not cool normally. As the\015\012ACs are turned on and off frequently the fan controls and compressor may also\015\012go bad. Please also check that there is no corroded wire. Please do accept the\015\012solution if the issue is resolved or post a comment for further assistance.
\015\012\015\012
\015\012\015\012
\015\012\015\012Thanks
\015\012\015\012Rylee

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a Sanyo khs1271 that is about three years old. For the last six months it has been making a high pitch chirping sound in both heating and cooling modes. I suspect the problem is the fan on the indoor unit as the chirping only occurs when the fan speed is on high. So far, the only solution to the problem has been to turn it on quiet mode, which reduces the fan speed and thus makes the unit's ability to heat or cool less effective. Does anyone know how to access the fan on the indoor unit


Hi You can try to check this link it has the user manual.Thankshttp://www.sanyohvac.com/assets/documents/user/Use ... Sanyo Air Conditioners

Our Fedders through-wall unit (A2T10F2B) turns on, and the fan works at various speeds, but the unit does not cool. What should we do?


Hi\015\012\015\012 \015\012\015\012 \015\012\015\012Thanks\015\012for using FixYa. The cause of not cooling can be Drain, Sensor or Electric\015\012Control might have gone bad. First of a ... Fedders AED24E7F Wall/Window Air Conditioner

This is a heating and cooling through the wall heat pump. It works normally when heating is selected - the heat pump runs and both speeds of the fan blow warm air. But nothing runs when cooling is selected. In other words the unit works normally when "High Heat" or "Low Heat" is selected but nothing runs when "High Cool", "Low Cool" or "Fan Only" is selected. The position of the Fan Cycle Switch has no effect - behavior of the unit is the same in both positions of the Fan Cycle Switch.


You have a bad board or bad switch. I would say board. You can have service tech check this out. There is only so far you can go without knowledge of Controls ad electricity. Russ ... Air Conditioners

When calling for cold air, the fan in the cooling unit hums, but does not spin. With a nudge, the fan does spin. Looks to be smooth and normal speed. However ambient outside air 80 degrees. the air through the register is 72 degrees. Is there a switch that will not allow the fan to start on its own if the coolant is too low? Do I have two problems, fan starting AND insufficient cooling? Unit worked well the last two days.


Sounds like start capacator possibly bad ... Air Conditioners

My bonaire evaporative cooler cycles from high to low fan speeds when set in the cool mode. It works fine at the required speed setting when just the fan (no water) is selected. It also dumps water immediatly the cooling cycle is turned off rather than holding it for about 40Min as it should. Sounds like a controller problem, but I'm not sure if it would be the touch pad or the board up on the roof mounted unit.


... Air Conditioners

Mr. Slim Mitsubishi MSZA12NA fan is making noise. Could the fan motor be bad after only 2 years of use? Where do I find parts for this unit. Is there a potential other cause for this hum that increases in frequency with fan speed? Unit has performed excellent for past 2 years cooling and heating year round.


... Mitsubishi Air Conditioners

Air Cools well but after about an hour, water starts coming into the coach through the discharge air side. Unit does not freeze up but if I shut the unit off, the tray that holds the water drains quickly, but doesn't drain well when the A/C is running. I always run it at high speed initially, though when you put the AC on Auto fan, it starts at high speed anyhow. This unit is in a Newmar Mountainaire 40' diesel pusher motor home


Your evaporator is probably dirty and is blocking some of the air flow so the air has to move around the coil and starts coming in through the condensate drain holes. That stops the condensation (water) from draining out the holes because the air is ... Dometic Rooftop RV Air Conditioner

I have a sunbeam 12000 btu window unit air conditioner. I can't seem to change the fan speed when it is in cool mode. When I put it on fan only it blows extremely cold air and i can change the fan speed. When i press the power button it stops blowing but it sounds like the motor is still running and I must unplug it to get it to stop.


Sounds like the switch is wired wrong.\015\012When you put the switch on fan only the compressor should not run at all, therefore their shouldn't be any cold air.\015\012Check the switch to see if it's wired right. ... GE Profile ASM10AA Air Conditioner

Unit cools but has only low speed. is fan bad or control board


Hi Joe, it could be one or the other, or may be just the switch. About the only way you will know which one it is, is if you have a meter that will read the voltage up to 220 volts if that is what voltage the unit is. I have seen 3 speed motors have ... Air Conditioners

I have a Duo-Therm Penguin model#610115405 that cools and the fan changes speed(slower) when the room gets cooled and the compressor kicks out, but the fan will not shut down.I have the same unit fwd in my RV that works fine. I tried switching the thermostat,ptcr relay and the capacitor that is below the ptcr. Any other suggestions ? Dont see anything that else that I can easily switch to check.Still not shutting down?


Hi,\015\012the relay that is suppling the power to the fan is welded shut and is not opening. This often happens with relays, the contacts get pitted and then they heat up and weld fast. The relays that run the fan faster and slower are still w ... Dometic Rooftop RV Air Conditioner

I have got vulcan evaporative cooling system and the fan has stopped working. It blows air but at very low speed. i checked the unit and can see the fan moving at very low speed. The water pump if working fine though. can any one help. Thanks


Try lubricating the fan brings ... Air Conditioners

Hi weve a Mistral MSS10 and it only blows on a low speed ? No gecko damge obvious cools but only on low fan, could the fan unit second speed be faulty and were can we get parts?


... Air Conditioners

I have 2 dometic roof top units on a 2002 MH that I recently purchased. 1 of the units only runs on high speed, the stat has a high low switch, the unit cools fine. The second unit, the comp starts, but the fan only hums, the shaft turns fine. I switched the start relay from the other unit, same result. I suspect that the start winding is open, but haven't checked yet. I am not opposed to replacing the unit because of age, condition of roof cover,and suspected cost of parts. Would appreciate any


Hi, unit # 2 sounds as though the run capacitor may be open, shorted, ect.When you say you changed relay, I assume you were talking about the capacitor. If the motor didn't run when you changed it, you do have a bad winding, or open as it just hums. ... Dometic Air Conditioners

Indoor Sanyo ductless split Model # KHS 2432 serial # 0012832, Works fan on and off functions and speeds. As soon as you set the remote to heating or cooling the unit beeps 5 times quickly and then the unit no longer responds to remote control. The blower will then run for 1 minute and then the the unit no longer will work. Power must be reset for blower operations to function again. Out door unit, has enough charge, Ambient temp 39 M#CH2432 S#0012424


... Sanyo Air Conditioners

My compressor unit outside runs and cools Freon but the inside blower has a problem running. the model # is 2TEE3F31A1000AA. The fan control, in fan run control mode, shows a bright green for the fan LED and the CFM selection LED varies with the rotational speed of the fan. The motor tries to start showing , initially, a jerky back & forth movement. It squeaks some and may, or may not, start rotating. If it starts the CFM LED goes bright/on no flicker and the motor runs briefly (5 seconds) then


Hi, from what you have told me, you are loosing the bearings in this blower motor along with windings. This motor is rubbing the blower housing, tight when you turn it, and when it jerks when it tries to start tells me that you have burned or very we ... Air Conditioners

Samsung window unit. Stopped cooling. Found icing on the cooling coils in the upper rightfront and on two smaller lines in the back that appear to go into the coils. Turned it off to defrost. After defrosting, set the tepm to 72 on cool and the fan speed to 2. Icing started again in the same locations within 5 minutes.


There are only two things that will cause freezing on an ac, lack of air flow or lack of refrigerant. verify the cleanliness of the coils, the blower squirrel cage, and the filter, if all are clean the charge need to be checked, the leak reapried and ... Air Conditioners

I have a rheem prestige series contour comfort control natural gas furnace. At the end of the heat cycle the unit will shut off, then the blower kicks on to cool off the heat exchanger. It will actually kick up on high fan speed to exhaust the heat. The unit is only 3 years old and it did not do this before.


Make sure that your furnace filters are clean it sounds like it could be cycleing on high limit. ... Air Conditioners

Futitsu Inverter Air-con {ASTA09LCC}- Fan operates but no refridgerated air. Remote is on 'cool', fan speed is on medium. When the unit is switched on the Operation light (red) and Timer Light (green) flash twice together, then Operation light flashes five times this reapeated after about five seconds. I am told that this can help diagnose the problem. I have reset the remote to cler any chance of the 'Timer' being set.


To cancel the timer, press timer on setting until it comes 00.00. Or remove batteries from remote and re fix after few minutes. If still problem persists, check and rectify error code of e-5 as follows: Comms Error, check your wiring, rem ... Fujitsu 24C1 Air Conditioner

My unit is running but not blowing cool air. I went outside and the condenor fan was not moving. Took a stick and shoved a blade and the fan started moving but the air is still not cool inside. I did notice the air coming through the unit outside after fan was blowing was cooler than my 2nd a/c unit that was working fine. I wondered if the entire unit was frozen. I turned off unit at thermostat and figured I would see what happens tomorrow


Sometimes on new units it is common for the fan to not start until you give it a push. Did you happen to hear if the compressor was operating? If the unit was froze-up the Insulated Suction line would also be iced over as well. If it wasn`t it is mor ... Carrier 38CKC024 Air Conditioner

I have a carrier Modle No. 38YXA042300. I am getting an H5 error message on my Thermistat Control. I have run the Fan only mode and the fan in the air handler unit works fine. On the unit when I ingage the manual override, the condener unit and fan motor runs and cools. The unit will not run when I put the Thermidistat on Cool mode. Can you help me. Andrew Construction Mangement Speicalthes, Inc.


On some carriers they have a lock out feature outside to reset shut down power to furnace for 90secs. and then restart ... Air Conditioners

The unit powers up and the fan blows well. The green light above the cool icon doesn't light up. Every 45-60 seconds the unit seems to strain and the fan decreases it strength for about 3-4 seconds and then it returns to blowing as bed ore. The unit does not seem to be cooling well. The unit is about 4-5 years old with less than 100 hours of use. It gets used maybe once a year. It was recently used last week, cooled great for two days and then began to function as described. Suggestions?


... Amcor ALTL-12000E Portable Air Conditioner

Hs29-030-2p lennox, It is not cooling at full capacity, the outside fan unit only running half speed I can hear a buzzing sound about every 5 mins like something is trying to cut on


... Air Conditioners

I have an older (1992) Trane Gas/Electric heating and cooling system Model # YCC036F1MOAA. I have been having problems with the unit not allowing the burners to stay lit. The thermostat calls for heat, the combustion fan comes up to speed, the gas is released and the electronic igniter is energized and the burners are lit. Too often the gas is stopped and the burners stop immediately. The system goes through this cycle two more times as expected with the same result and finally the combustion fa


Hi Mke,\015\012The flame sensor system works by passing a small amount of electrical current through the flame from the flame sensor and then back to the ignition control through the ground wire...\015\012the gornd wire is the green wire ... Air Conditioners

The fan on outdoor unit sometimes starts normally, sometimes starts slowly and will get up to speed with a push or sometimes will not start at all. Loud hum when slow or stopped. Cools normally when it will start. Have replace capacitor. Any ideas?


SOME MODELS HAVE A TEMPERATURE DEVICE THAT CONTROLS THE FAN WHEN REAL HOT IT WILL CONTROL THE SPEED OF THE FAN WHEN COOL OUT THE FAN WILL VERY FROM FAST TO SLOW DEPANDS ON THE HEAT BEING PUT OUT BY THE OUT SIDE UNIT IF THIS PROBLEM OCCURES DURING BOT ... Air Conditioners

The temperature is set for 77 and it only gets cool to 84-85, which is what it displays.It's an HWR10XCB model, which looks like the unit pictured above. It's fan speed is set on HI, The function is ac, the timer isn't on. The air sweep is off and the energy saver is off. There are two lights to the right of the temp, a top and bottom light. The bottom light is lit up. Do you know how to make the ac go to 77?


Hi, there are several thing that can keep this unit from cooling. You may be low on freon, the compressor may not be coming on, these are things you need to check by going out side and look touch and listen. See if the air coming off of the condenser ... Haier HWR10XC3 Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"