Having problems with your Air Conditioners ?

I have an amana rha36b2a heat pump and am trying to hook up a new thermostat. It's a pro 1 iaq t905 programable thermostat. I have hooked up the green yellow white and red (and ran a jumper wire from rh to rc). I also ran a jumper wire from W to Y. I ran the brown wire to C. The thermostat works great for heating but won't cool. When cool is chosen the heat comes on. Help! I know the O and B on the thermostat are the heat and cooling changeover valves but what should I do to connect them if that


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have an amana rha36b2a heat pump and am trying to hook up a new thermostat. It's a pro 1 iaq t905 programable thermostat. I have hooked up the green yellow white and red (and ran a jumper wire from rh to rc). I also ran a jumper wire from W to Y. I ran the brown wire to C. The thermostat works great for heating but won't cool. When cool is chosen the heat comes on. Help! I know the O and B on the thermostat are the heat and cooling changeover valves but what should I do to connect them if that


... Air Conditioners

A Nordyne air handler, model B3BV-030K, with 4 wire thermostat. Thermostat and AC works fine in "cool". Switch it to "heat" and nothing happens.No fan, no heat.(I have built in heat strips -resistors). I jumpered (on the nordyne circuit board-input from thermostat) from R to W. (24 volts from R to W, which should start the heater. Nothing. No relay "click" like when AC comes on. If i jumper R to Y, AC comes on ok. Does this sound like a relay gone bad on the circuit board? Or what? If relay bad,


Do you get heat when you jumper R, G & W? ... Ruud Central System Air Conditioner

I just installed a P474-1100REC & P474-1100RF in place of a Honeywell Thermostat.I have a typical 4 wire 1 stage Cool 1 stage gas heat setup. The new thermostat is not working right. I noticed on the old thermostat there was a jumper wire from R to R1. Do I need a jumper wire set-up here as well? If I do where do I connect to? There is no R1. Please help


Does the new stat have a rc and an rh if so you will need a jumper between them ... Air Conditioners

I installed a new honeywell rthl111 series in Oct. 2012. I wired the blue wire to the RC because that was how the old thermostat was wired. The heat worked all winter but when I tried to change over to cool nothing would work. I checked the schematics online and realized I should have installed the blue wire to the B. I checked the fuse in the power panel and saw I had blown it. I changed it and rewired the thermostat the correct way. I tried again and still neither the cool or heat will work. A


... Goodman Air Conditioners

I have an old Miller 3 ton heat pump. It will work fine sometimes but when it decides not to work i can go outside and press the power contactor and the unit will come on as long as i hold the contactor pressed. A friend told me the defroster board could be the problem because when its cooler than 45 outside it wont come on by itself. But when i measured voltage at the thermostat no wire had 24volts.When it runs it runs good and cools or heats the house well.


It sounds to me you need just a really good tune up maybe a new contactor retest your low voltage what do you have from common to 24 volts it should be 27 volts if you test each wire you want get 24 v it will be like 7 or so ... Air Conditioners

I installed the rth2310 and it seemed pretty straightforward. I had R, W, Y, G, on the old thermostat, and hooked them up to the same, with R to Rh with the jumper in place. Now, the snowflake cooling symbol is on all the time, and when I turn on the heat, it just runs all the time. This is a zoned system. I replaced another thermostat at the same time, and it works fine (it had a black wire going to Y, but otherwise the same).


You need a jumper between RC and RH. ... Air Conditioners

Lennox Conservator III G16, Furnace, Burners stay lite for 90 seconds; no blower; but exhaust fan runs continuous. If I use a jumper from the white heat wire (including white heat wire) to the green blower wire terminal (removed the green thermostat wire) the blower fan runs (non-stop) & igniter & burners restart every 10 mins. when I remove the jumper (& wire to specs from the thermostat to the furnace) igniter & burners kick on for 90 seconds then nothing on the unit works except the exhaust f


... Air Conditioners

I have a Goodman air handler Model# PHJ042-1B Goodman unit- --------------------- R G Or Br W Y B Tstat (present wired in unit R G Blu W Y Present Hunter stat wires wire --- G Blu R Y W stat connectors G Rc Rh Y W (Rc & Rh have jumper) How do I wire new stat a pro 5000 2 heat a cool w/ 18/8 wire and have it work correctly and have the compessor reverse valve work. Pro 5000 stat reads Top


... Air Conditioners

Goodman GSH130301AB heat pump with Braeburn 1200 multi-stage thermostat - both less than 1 year old and installed in new construction. Heat can be set at 60, fan on AUTO, with room temp at 70 and heat will kick on and stay on. When this happens, turning thermostat to OFF does nothing - system continues to blow heat - and I can only shut it off by flipping the breaker. This only happens now and then - typically works fine. All wiring appears to be correct though reversing valve for cooling is


The reversing valve wire needs to be on the o terminal.nothing will be on the b terminal on the thermostat ... Goodman Air Conditioners

We installed a Honeywell RTH230B thermostat on a Trane XE60 Air Handeler this winter. When we put the system on heat it works fine. However, when we put the system on auto for cool the compressor fan comes on but not the air handeler fan. On the air handeler the terminal strip from left to right is R W Y G B/C. The red wire on the R terminal comes from the contactor on the compressor unit. The other wire from the compressor unit is connected to a gray wire that goes to the thermostat. The W


I ran into this before and had to call Honeywell for help in the wiring...it seems the wiring was not done to standard, and they were able to help me get it straight in about 10 minutes and at no charge. ... Air Conditioners

I just replace a Honeywell T87F28733844 Thermostat with a Honeywell RTH221 Thermostat since then my the furnance will not produce any heat. I replaced the thermocouple, but still no go. The pliot light is lit, but still no go. The wires that went to the T87F are yellow, green red and blue. The RTH calls for a yellow, green, red, and white, with a jumper jack in the Rh Rc. The blower for the fan works, and the ac works, but not the heater


The heat circuit uses 2 wires to the thermostat one is the power from the transformer, and the other goes to the gas manifold.\015\012\015\012The Rh and Rc is probably the power for heat and cool, and this is where the red would attach IF ... Air Conditioners

I have a hunter programmable thermostat model #44155c and Im trying to wire it to my goodman furnace. Its a 7 wire system with a white,yellow,red,green,brown,blue, and orange wire. The ac works fine but the heat wont shut off. Thanks


Make sure you do not have a jumper between the red and the white. Also make sure the wire is not hanging out from behind the screws. If the heat stayes on no matter what you do. The red wire has to be touching the white somewhere. \015\012The r ... LG LSC183VMA Split System Air Conditioner

I have an Amana RHE30A2B heat pump. I installed a new thermostat, Honeywell, last night and now the coils are not cooling & the unit is blowing hot air. I have double checked all the wiring & everything seems to work as it should. Is there a breaker or fuse on the outside unit that I am not aware of before I call a service man out. We also had an electrical storm last night. It could be a freak thing, but I am still concentrating on the thermostat.


Hello,If you can hear a click or see a light when you turn your thermostat from up to down you do have power there. Or, you can put a meter on your thermostat and see if there is any voltage or not. If not in either case, you can try this ... Amana Air Conditioners

I own a non programmable digital thermostast RTH3100C THAT WAS INSTALLED AND KEPT MY AIR CONDITIONER COOLING WELL. HOWEVER, WHEN I TURN TO HEAT IT WOULD NOT HEAT THE PLACE. I JUST GOT COOL AIR. I WAS INFORMED BY YOUR CO. THAT THIS THERMOSTAT IS NOT FOR HEATING. I HAVE AN A/C WITH A PACKAGE OUTSIDE AND AN INSIDE AIR HANDLER WITH A HEAT ELEMENT. COULD IT BE LHAT IT WAS NOT PROPERLY WIRE. I ONLY HAVE THREE WIRES FROM THE OLD THERMOSTAT


Are there any wires on the e or aux terminals. those are the terminals for heat ... Air Conditioners

Carrier thermostat Hello, My Carrier electronic thermostat is connected to a heat pump.  It was set to the COOL position during a summer thunderstorm when the AC suddenly began running no matter what the SET temperature was.  It works normally when I change it to the AUTO position.  The HEAT and EHEAT positions work normally. I tried cutting power to the unit for 2 days, after which it worked normally even on COOL, but after a short power failure it resumed the problem of running the AC continuo


I hate to say it but Ive had trouble with Carrier's Tstats doing similar improper things. Unfortunatly the only repair is going to be replacement of the whole tstat. I recommend Honeywell's FocusPRO or VisionPRO tstat. Ive yet to have one fail and th ... Air Conditioners

Reset button for Ruud Achiever 14 heat pump/AC compressor? My Ac/heat thermostat was blowing fan on and would not turn off. I switched it off at the circuit box, and bought a new thermostat RTH221, wired it and it would not blow cool air when on cool nor warm air when on heat. Called the 800 number for Honeywell and tech said I had wired it correctly, to check outside and see if the compressor was running. It was not. This Ruud unit is only 8years old so I'm wondering if a reset button has


... Air Conditioners

I have an intertherm rpbmb030k combo a/c and heat. Had frion put in the unit over the summer and a new digital thermostat. Unit has worked great until we needed heat. Unit works great on aux. heat but keeps switching to to defrost mode when standard heat is on. Switched out the defrost board on the unit to no avail and an a/c guy checked to ensure the new thermostat was wired correctly.


Hi, if the unit had a leak in it, was the leak located and repaired? Did he check the pressures in the unit now? If it switches to the aux mode ( Heat Strips ) is normally caused when your primary unit, compressor and freon are low on charge. I would ... Intertherm P3RA-060K Air Conditioner

Amana PTAC Unit is not producing heat. Fan works fine. can not locate manual reset for heat although a label on the unit says there is one. I have an Amana pth153b35ae ptac unit that the heat will not come on. The compressor will run in the cooling mode but not in heat mode. I verified the switching valve is working and the capacitor seems to be fine as the compressor will run in cooling mode. The thermostats seem to be functional because relays can be heard clearly when changing temperature se


I know this is late but I had to add a solution to this problem since I had the exact same problem and was able to solve it. The probelm is not your control board. On these units, the heat pump compressor will not kick in unless the temperature you ... Amana PTH123B25AJ Heat Pump Air Conditioner

My heat isnt working now but in the summer time my ac works. but last year my heat woulodnt work but then one day started working. then the summer time my ac wouldnt work then one day started working an now that it is cold out again my heat wont work. what could be the problem. i already tryed replacing thermostat. an the heater core is working cause both lines are hot.


What kind of air con is it. it would be a sticky reversing valve either from inside the valve or the solinoid pulling it siting on the valve. http://t3.gstatic.com/images?q=tbn:SMSfcwrA_p4i6M:http://www.daviddarling.info/images/reversing_valve.jpg&t= ... Air Conditioners

Amana heat pump ptac pth123b35ampb heat does not work when wired through the thermostat, when configuring the ptac to c1 re on the touchpad only and not using the thermostat, the heat works just fine, what could cause this issue?


... Amana PTH153B50AJ Heat Pump Air Conditioner

Rudd furnace I have a RUDD furnace model UGPJ-07-NAMGR. It had stopped working, so I replaced the thermostat but it is not the thermostat. When I hold the furnace reset button, the furnace will fire according to the setting on thermostat(heat or fan). As soon as I let go of the reset button, the heater stops working. It does not matter what I do to the thernostat, the heater will not fire. I crossed the red and white wire but nothing happens. The heater is supposed to fire when I cross wire, ri


You have a safety limit switch that is either bad or needs to be manually reset. Some have little buttons between the two wires going to the switch that you can push to reset. If not they are automatic switchs then one is bad. You have to do an oh ... Ruud UBHC Air Conditioner

I have a Tempstar model NFCP3600A1 (style # FCP3600A) ICP Heat Pump. Starting last week, the unit kept heating well over the set temperature. I swapped out the thermostat thinking it went bad, but it still continued heating and the "off" wouldn't work at the new thermostat either. Next, I checked for shorts in the thermostat wires and they seemed OK. I then replaced the TI 26FC-2 circuit board. Once the unit heated the house to the set temp, it continued running up to 75 degrees. "Off" and lowe


... Air Conditioners

Heat Pump I have a intertherm heat pump , compreser working , fan on outside working , thermostat calling for cooling , large line from compreser to inside coil sweating and cold and still no cool air ??/


Your inside cooling coil in the air conditioning mode could be frozen over. Change the fan setting to on and operate it that way when in the cooling mode. Turn the air conditioning OFF with the fan ON to clear the coil of frost which should take abou ... Air Conditioners

Still working on our ac inside unit Coleman EB20B outside unit Goodman CKL49-1. We had a short in the thermostat wiring that we repaired. Now the AC is working when the fan switch is on run. It doesn't run with the therm switch on the cool cycle. Have we crossed wires somewhere or is our thermostat bad? Thanks Ken Rohm


You could have either situation. You could also have a bad thermostat sensor, as it talks about in this blog:\015\012http://hubpa ... Coleman Air Conditioners

My 2001 VW jetta VR6 heating and cooling are not working. Sometimes if I turn the AC on I will get a little bit of cool air but it wont blow hard, but most of the time it doesnt work the heating is the same way.


... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1311 seconds