Air conditioner blower motor not kicking on - Air Conditioners


Answers :

Either motor is bad or contactor is not suppling power to motor, but chech panel for blower, there is a switch that must be pushed in or it will not operate

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Air conditioner blower motor not kicking on - Air Conditioners


Either motor is bad or contactor is not suppling power to motor, but chech panel for blower, there is a switch that must be pushed in or it will not operate ... Air Conditioners

Hi, just replaced the capacitor thinking that would solve the problem but it appears it did not. The motor outside would kick on the unit inside would kick on but the blower motor inside works sometimes and wont other times. Basically, the unit will work just fine all day then we notice the house is getting warm, check the inside unit and everything is running fine but the blower motor is not circulating the air. I have a goodman a30-10 unit. I read where some people said the relay could be bad


Turn off the power to the air handler(indoor unit). Remove the access panel. From the motor,trace the wires back to the fan relay. One wire will probably trace back to the incoming power terminal. The other is the fan relay. It could be intermittent ... Air Conditioners

Blower fan motor wont start on carrier package unit air conditioner I have a Carrier 50ZPA042-301TP package unit


... Air Conditioners

Blower motor in home air conditioner does not work


The most common failure for this problem is either the start/run capacitor or the fan motor. IF YOU ARE NOT experienced with electricity then I would strongly suggest hiring a technician. The volts are 220 with a potential of 50 amps in a common resi ... Air Conditioners

Dometic 579 Series Brisk Air AC runs fine-blower still runs but every couple minutes it "kicks on and off" it will blow hot air and then cold air and continues to do this. Did not do this until we installed a new motor.


Sounds like it is skipping the motor I mean, I am assuming that it was replaced with the correct motor(rpms,hp,volts). As if it was not it will skip, like it is doing now. ... Dometic Rooftop RV Air Conditioner

Goodman air conditioner model #PC036-1a; when you put on heat the unit kicks on and blows out air with no problems but when you try to turn ac on, you can hear the motor click on like it's trying to start but no air blows out of the vents. thought it might be the relay switch? any suggestions


Try replacing the control board most the time its a relay stuck open for high speed on your fan ... Goodman Air Conditioners

I have a ruud furnace/airconditioner Model:UGPN-07EAMER, Serial: FU5D302F390401344. When the thermostat calls for heat, a little motor (within the furnace itself) or something kicks on, the burners ignite a few seconds later, then the blower starts. It's at this time the flame goes out and the blower is just sending cold air throughout the house. There are two green lights (power and ok) lit normally and the orange(ish) blinking "flame" light on the main board. When the flame goes out, the


Hi, this motor is the inducer motor, which is the first thing to start on a call for heat. Everything seems to be going through its sequence of operation just fine, but then shutting down on a safety. Look on the panel for a chart that should tell yo ... Air Conditioners

02 mercury grand marquis. i have no air hot or cold coming out the vents. i removed the blower motor and it spins ok. everything in the panel lights on but no air is coming out. i can hear the ac kicking in and out.


Check the fuse for the blower motor. It may have blown. If that's not it, it may be the damper door in the heater box itself is stuck closed. Not sure if that model year damper door is operated pneumatically or electrically. Hopefully, you still hav ... Air Conditioners

Replace fan motor xe 1200 trane blower motor - Air Conditioners


... Air Conditioners

Gibson air handler blower motor runs slow - Gibson Air Conditioners


Change the fan capacitor. ... Gibson Air Conditioners

Air conditioner runs for a few minutes then kicks off and won't kick back on. Replaced the fan motor and capacitor. Not sure what else it could be?


... Air Conditioners

Hello i have Carrier Weathermaker 38tkb air conditioner unit. It's about 6 years old and when i got home today, the unit itself wasn't working. Although the blower fan in the furnace inside was blowing, the fan on the a/c unit outside was not moving. I can hear a humming sound coming from it and once in a while, you hear it trying to kick in (the lights in the house even dim a bit, which is unusual), but it never kicks in. The top center of the unit is extremely hot to the touch. I've checked


The humming noise and dimming of the lights is an indication something in the outdoor unit is locked up or has failed.Check the capacitor as it may have gone bad. If the capacitor is good, then you either have a failed motor, a failed co ... Air Conditioners

I have a wall mounted Kenmore 21,000 BTU/hr air conditioner model 106.8752192. The compressor and cooling portion of the air conditoner works fine. However, the blower motor bearing appears to be going bad. The noise at ''LO'' speed with the compressor off is gradually getting worse. Is it repairable? What is the estimated repair cost?


Sure it is repairable, in fact it's a relatively simple process if you are familiar with electronic devices and handy with tools.\015\012\015\012You will need to simply replace the blower motor and capacitor.\015\012\015\012Mo ... Air Conditioners

Need to change a broken blower motor in RUUD central air unit. Old central air blower motor (GE electric) was connected with brown and orange wire to 15 MHD capacitor. Another orange wire from central air unit connected to orange motor wire on capacitor. Black wire from motor (Hi Speed) connected to central air unit. Blue and red wires not connected. New motor is an AO Smith FD6000A. Has Black, brown/white, brown, blue,yellow,red, white and black wires. Need to connect to a 5 MHD capacitor. M


On the motor should be a diagram detailing the wires. brown white goes to either side of the capacitor and brown wire to other side of capacitor. hi speed goes to normally open contact on the indoor fan relay and the wire designated common on the mot ... Air Conditioners

There is always a build up of water around the blower motor. When turned upside down the water will come out...but come back almost immediately!! The water noise is very loud and the air conditioner is not cooler the room as well as before.


Clean your air filter located in the front of the unit dirty filters can cause ice build up ... Frigidaire FAX054P7A Wall/Window Air Conditioner

I have land cruiser wagen model 1995 the proplem in air conditioner when oprate the plower switch to low or m1 or m2 or high is ok but when moving the thermostat to hot the blower motor is not working.


In some models the air conditioning system and the heating system are separate and you need to switch off the aircon if you use the heater. Or if it is a heatpump system, the fan will switch off while it is in reverse cycle allowing pressure to build ... Air Conditioners

When I turn on the air conditioner (DeLonghi Pac L90) the fan blows but the coolant motor isn't kicking on.


This could be a couple problems: A bad relay to the motor, a bad capacitor on the main board that feeds power to the motor, or the brushes inside the motor are stuck to the motor's armitron. Try lightly tapping all around the motor to see if it freez ... Air Conditioners

The fan or blower motor is not turning when I switch air conditioner on.


MY AC UNITE IS ARCHING OUT SIDE THE CURCUITE BREAKER IS TRIPPING OFF ... Goodman CKL36AR36 Air Conditioner

Replace blower motor - Air Conditioners


I have beumark referigerator and its fan cooling freezer went off.I need solution ... Air Conditioners

Relace blower motor... - Air Conditioners


... Air Conditioners

Blower motor wont stop - Carrier 38CKC036 Air Conditioner


If you are talking about the indoor blower motor, check the fan switch on your thermostat to make sure that it is in the auto position. If it is, you could possibly have a stuck contact in the thermostat or the relay in the board has stuck open, you ... Carrier 38CKC036 Air Conditioner

My air conditioner won't turn on. When thermostat is set to cool, the furnace blower kicks on but the compressor and outdoor fan do not.


Sounds like your not getting a low voltage signal to the condenser, if your Air handler is in the attic check your secondary drain pan it might be off on the float switch, if your air handler is in a closet you need to check your float switch, it wil ... Goodman CKL42AR42 Air Conditioner

Air Conditioner seems to be working but the Blower Motor does not come on.


Some units use a relay to change fan speeds.Heat requires a slow speed while cool requires a faster speed, Take a ... Air Conditioners

I don't know if the motor is shot or what, but when you turn it on, it hums as though it's going to come on, but nothing blows out and nothing ever kicks on. Trying to decide if it's worth it to try to find someone to fix it (it's a casement window air conditioner, so it's not like we can replace it for $100), or whether we should just look into buying another.


The fan motor might be bad or the fan blades are obstructed. the compressor won't turn on if the fan isn't blowing. see if you can move the fan easily manually. ... Fedders Air Conditioners

DO i need to oil the blower motor? - Intertherm Air Conditioners


If the motor has oil ports add just 3 drops of 20weight non-detergent or turbine oil in each port. Do not over oil it and do not use 3n1 oil. ... Intertherm Air Conditioners