I am installing a totaline progammable thermostat, the old one is a rheem, i hooked the b wire to the b terminal the r wire to the r terminal the g to the g terminal and the y to the y terminal the e l and o were not used, my problem is the old thermostat had a w2 and a x terminal the new one has aux and c which wire goe to which?


Answers :

First off, make sure that the wires you are connecting at the thermostat match the circuit board of the unit. It is good practice, but not always followed to do a "1 for 1". To answer your question, W2 is simply when there is 2-stages of heating. If your furnace does not have 2-stage heating, then leave it empty on the t-stat. "C" is common. Common is neutral, so it should have continuity to the ground or L2. If your old stat did not utilize this, I wouldn't worry about it, unless the new stat is a touchscreen and constantly lit stat. Just keep this in mind. W-warm (heat), Y-cooling, G-fan, R-hot (main 24v power from furnace to thermostat), C-common (not always required), AUX (auxillary, if there wasn't one used on your last furnace, I wouldn't worry about it.). X may have been a common, or a dead terminal. \015\012
\015\012Bottom line, if you open your furnace to see the circuit board and where the thermostat wire connects, and match above, you should be just fine. Make sure you turn power off prior to opening the furnace, and when landing the wires on the stat. You could inadvertently blow the 24v transformer.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I am installing a totaline progammable thermostat, the old one is a rheem, i hooked the b wire to the b terminal the r wire to the r terminal the g to the g terminal and the y to the y terminal the e l and o were not used, my problem is the old thermostat had a w2 and a x terminal the new one has aux and c which wire goe to which?


First off, make sure that the wires you are connecting at the thermostat match the circuit board of the unit. It is good practice, but not always followed to do a "1 for 1". To answer your question, W2 is simply when there is 2-stages of heating. ... Air Conditioners

I bought a hunter 44860 and i want to replace my old ruud thermostat that has wire code: w2 which has one wire jumped to e, b, g, r, y, and x my new hunter has wire code: y1, y2, w2, g, rh jumped to rc/r, b, w1,e, o, c, and l. i dont know which one goes where can you help me?


Hopefully you have heat pump with electric resistance back up\015\012Y to Y1. R to Rc/Rh. X to C. Everything else should be same ... Ruud Air Conditioners

I have to replace the start/run capacitor (97F9971 - Duel Capacitor/ 50, 7.5 370 VAC). I have marked the terminals before removing and purchased the new capacitor. The new capacitor has minor difference with the old one. The hermatic has 3 terminals, The Fan has two terminals The Compressor (C) has 4 terminals. Now in the old unit, two wires were connected to two opposite terminals on C, one in Herm and one in Fan. My question is: How will I know which terminal to connect in the new one


All the terminals are connected together so it won't matter which terminal you use, just as long as you have the Herm, Com, and Fan wires correct. Hope this helps! ... Air Conditioners

I am installing a new 3 1/2 ton heat pump the thermostat they sold me does not have the W-1 terminal for the white thermostat wire run from unit or the W-2 for the brown wire. One must go to Aux. Heat and the other the heat and although I am licensed and experienced I cant for the life of me remember which goes to which


Hi,W-1 goes to the heat and W-2 to the Aux. heat...so white on the heat and brown on the Aux.heatman101 ... Goodman CKL30AR30 Air Conditioner

Replacing old heat pump thermostat with not quite so old heat pump thermostat. New thermostat is Luxpro psmh45. Old thermostat had an AUX tab. New one(lux) does not. Where do I put white wire that went to Aux on old thermostat on new one?


Can you provide the manufacturer name and model number of the old and new thermostats? ... Air Conditioners

I tried to replace my digital manual Honeywell thermostat that is only 6 months old (new construction) with a programable thermostat. I followed the instructions marking the wires and connecting them up the same way. There was one wire "C" wire that the old thermostat connection said was optional with batteries that there was no place to connect on the new thermostat. I taped it off and left it off. The new thermostat with batteries powered up but the AC would not respond, nor the fan, nor t


Your "R" terminal is basically your "hot" and your "C" terminal is basically your "neutral" to simplify explanation. The Furnace supplies the "R" power to the thermostat and then depending on what wire the thermostat sends the power back on determine ... Honeywell Air Conditioners

Installed a new Filtrete thermostat on a new Carrier high-efficiency furnace. I followed instructions exactly. It doesn't work. What did I do wrong? Furnace was installed in December. Broom handle cracked faceplate of Carrier thermostat and rendered it inoperable. Installed new thermostat according to instructions. Connected white wire (labeled V+ on the old Carrier thermostat) to the W terminal on the new Filtrete thermostat. Connected red wire (labeled Vg on the old Carrier thermostat) to the


Thanks for the update, regarding the thermostat.Hope replacing the thermostat resolves the problem.Keep updated.Thanks.Helpmech. ... Air Conditioners

I am installing a new thermostat for my baseboard electric heat. The electric box has 2 wires comming into it. So I have 2 black, 2 white and 2 ground. The old thermostat had a place for all 4 wires (one side line one side load) the new thermostat is a honeywell RLV430 High voltage (at least I got the high voltage part right). It only has 2 wires so I am at a loss as to what to hook up where. My inclination is to hook the load to one and the line to the other. But I don' know if this is r


Hi tlef\015\012\015\012To answer your question;\015\012\015\012Tie the two whites together with a marette , and the two blacks to the thermostat , it doesn`t matter which wire goes where on the thermostat since there is no polarity.\015\ ... Air Conditioners

I am replacing a white-rodgers thermostat with a blue wire connected to a terminal label '4'. The only other reference to a '4' terminal is in the honerwell installation manual which says that if there is both an r and 4 terminals on the old thermostat it was incompatible. I returned it for a ritetemp guaranteed to be compatible though I'm still not sure what to do with the blue wire. on the old thermostat the red wire goes to rc, the yellow to y, white to w, and green to g. Does blue just go t


Blue just goes to B ... Air Conditioners

I have a Janitrol Heat Pump Thermostat HPT-18-60 and need assistance connecting my new Honeywell RTH7500D thermostat I have a Goodman Heat Pump System Indoor Unit Model#AWB24-05C REV D Outdoor Unit Model#CPLE18-1 Here is the wiring of the old thermostat Y-Yellow Wire G-Green Wire R-Red Wire O-Orange Wire W2-White Wire E-Blue Wire C-Black Wire Where should each of these be connected to the new thermostats terminals?


... Air Conditioners

I am changing an old circular Honeywell AC thermostat to a new Honeywell VisionPro TH8321U thermostat. There are two wires coming from the old thermostat and I want to know which terminals do I attach the wires to on the new thermostat?


Ac only?r and y ... Honeywell Air Conditioners

I have a Rheem Gas Furnace with an old analog thermostat (Wires conneected to terminals R and 4 for the thermostat). I went to install a Rheem digital and programmable thermostat and it indicated that it would not work for that wire configuration (Instructions indicated that the thermostat would not work with wires to the #4 thermostat terminal). Is there a setting on the furnace circuit board I can change, or is there a digital, programmable thermostat one can use on this unit - Model RGDJ 12EA


If you have 2 wire at thermostat Terminals at furnace that the thermostat wire attach to should be R & W if your new thermostat has R & W terminals is should work, an easy thing to remember is the red wire on R the white wire on W. If 4 wire ... Air Conditioners

I have a carrier 38YKC036300 heat pump with an electric furnace. I am attempting to install a new bryant T6-PRH thermostat http://www.catalog.bryant.com/wcs/proddesc_display/0,,CLI1_DIV42_ETI4641_PRD1583_SIT70,00.html. The wires dont exactly match up with my old existing thermostat. My existing thermostat has the following connections: W2, C, R, G, E, O, and Y. My new thermostat has Rc, Rh, W/W1, G, Y/Y2, C, O/W2/B, Y1. Please tell me which wires go with which terminals on the new thermostat. P


Old Tstat New Tstat\015\012R Jumper Rc & Rh\015\012E W/W1\015\012G G\015\012Y Y/Y2\015\012C ... Carrier 38CKC036 Air Conditioner

I just got a new honeywell thermostat and it when i first hooked it up it wouldnt turn on so i check to find out which connections on the thermostat when open i changed my wire to make it correct now when it turns on it doesnt turn off. i only have 2 wire that were on the old thermostat and the new one shows spots for 3 wire do i need to run a 3rd wire to get the furnace to shut off after it reaches desired temp? right now i have to disconnect the thermostatto shut it off.?


Hello my name is Heath it will be my pleasure to assit you. If you did not turn the power off to the furnace before rerplacing the thermostat then you may have burned out the board in the furnace. But first if there is a RH/Rc terminal in the new the ... Honeywell Air Conditioners

I have a Trane XE 1000 and attempted to replace the thermostat. When I saw that the wiring configuration was set up for a different configuration I put the new thermostat back in the box without trying to wire it. I put the old thermostat back on, wired it just like it was (I took a pic of the config before I removed it) and now I can not get the system to power back on. Is it possible I blew a fuse or tripped a breaker in the process of reinstalling the old thermostat? There was one point where


You could test this by totally by passing the stat and connecting through a wire linc.\015\012However you seem a little to inexperienced to be doing this and in my opinion you should for safety sake wait until monday,for a tech. ... Air Conditioners

I currently havea honeywell thermostat model# T8112D1005 (1) 0347 PF2A and a replacing it with a Honeywell TX1500E. My only issue is my old thermostat has a "R" wire that was connected up to it and my new unit only shows two options "RH" and "RC" it does not have an output of only "R". My question is where do I hook up the wire marked "R" from my old unit or do I even hook it up? The instructions mention if replacing a TM-11 to tape off the R wire and hook up the B wire to the B terminal. Im nit


... Honeywell Air Conditioners

My thermastate went out and i cant hook up the new one because it is not labled, and i need to know how i figure out what wires need to go to with letters (o/b, y, r, g, w). There is a plug with 10 wires ( there are colored ) that goes from the a/c unit to the thermostate, and seperate red and wite wires going to the thermostate. Also there was 12v power going to the other thermostat. The only thing the new thermostat has for hookups is o/b, y, r, g, w. can you help


Let me guess, you have a flat ribbon type harness coming from AC unit to thermostat, correct?Older Ac unit? What thermostat model came off, and what type are you trying to install? ... Dometic Rooftop RV Air Conditioner

Thermostat wiring I have a Frigidaire Model R4GA FWA and Central A/C system. I am trying to replace the thermostat with a programable Hunter model. I do not have the original wiring diagram and the old thermostat is no help. The wiring colors I have is Green, Red, Brown, Yellow, White and Orange-(not used). The terminals on the new thermostat are RH, RC, Y/O, W/B, G, and Y1.


Your best bet and where i would start is to identify where the coulors are conected at the fernace. in the industry we use standard wireing coulors wher green is g for fan and red is rh=switched trans power for heating . rc=switched transformer pow ... Air Conditioners

Trying to connect a new dual capacitor for an a/c unit. Three wires came off the old one, blue to the motor, red to the contactor and a brown wire. The new capacitor has two black and 1 white connectors, whick one goes where.


The cap should be marked to with goes where. White is more than likely common which will go to the contactor. The other two one to the motor and one to the fan. May be marked C-C-F Compressor, Common,Fan ... Amana Air Conditioners

I've replaced my very old (mercury) Honeywell thermostat with a new one (round, Model: YCT87K1011), but I can't get it to control the temperature. If I connect the two wires one way, the furnace comes on but won't shut off. If I reverse the wires, the furnace doesn't come on at all. I've actually tried two of these replacement thermostats with the same results. Any suggestions? John


Hey John, man that ole T87 has been around for a hundred years and I have installed many of them, but I cant remember the letters on the wiring. Seems to me that it is R-W-Y, any way you will use the R and W. I have a t87 at home still in the box an ... Honeywell Air Conditioners

Replacing the thermostat, took the old one off without marking the wires. Hooked it up by color and we get the furnace when we put it on cool. wires are green, red, yellow & blue (ground wire)on the wall. The new thermostat wires are red, yellow & green. Can you tell me which wires go where correctly?


The normal wiring for stats is white=w=heat,red=r=24volts,green=g=fan,blue=c=common,yellow=y=cooling.\015\012see what ties into your furnace board and match the terminals. ... Honeywell Air Conditioners

I need to replace an old Thermostat that just has 3 wires coloured Red, Blue and Yellow. The Honeywell THR830TUK Thermostat I have bought shows 5 wires on the diagram. I'm not sure which wire goes into which Terminal. Can you please advise? Regards Tim


The honeywell THR830TUK thermostat does not require a neutral as shown in the instructions.Connect the LIVE to terminal "1" and your YELLOW SIGNAL wire to terminal "3".Connect your EARTH (if you have one) to the EARTH connection on the top left ... Air Conditioners

Hi I have a hot air furnace and just replaced the board ith a new one from a gmp 100-3 to a b18099-13 I connected the wires as the directions said to but the staus light goes on continuous but nothing happens no flame or anything there is a terminal FS do I have to take the blue wire off the edge board and connect to this terminal its the only terminal that has nothing connected to it


What is the model number of the unit you are installing this on. ... Goodman Air Conditioners

I recently purchased a Honeywell RTH2520 thermostat. Our old mercury thermostat only has 2 wires, red and white or red and black. The new thermo has terminals Rh Rc W Y and G, with a red jumper in between Rh and Rc. Where do I connect the wires to? Do I have to take out the red jumper? Or leave it in while connecting to Rh and W...we have no AC


Use the RH & W terminals. You cannot connect it backwards so it's a breeze. ... Honeywell Air Conditioners

Hi i have a white rodgers thermostat model 1f58w-58. And I need help! We tried to change the thermostat to a new one, but for some reason the ac would not turn on. So we put the old one (white rodgers) and put all the wires back how they were and it still won't turn on! is there a fuse or something?


... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0948 seconds