Having problems with your Air Conditioners ?

Looking for freon capacity for 5 ton goodman package unit, cannot read serial or model number.. unit is 1998-2000 model ,, we just replaced the accumulator and we are not sure how much freon to put in.. Goodman offers no help whatsoever.


Answers :

Check low side which is the bigger of the two, make sure you tighten the hose good. your reading should be 65 psig.If not add refrigerant/r22 . if r410a 110 to 115.
Hi, Normally the amount is stamped on the data plate on the amount the unit holds. Unless it is rubbed off to, it will be right there in pounds and oz.. You can charge it if you know the type of freon, R-22 by using the charging chart on it which it should also have. You can also charge it by using your amp probe and gauge's to get it real close until the suction line starts to sweat and you are not over amping the unit. Also, you can charge it by using your gauge's and the ambient temperature. Install your gauges and start to add freon. Watch your high side gauge. Take a reading on the out door temperature. If you are using R-22 or 410-A look at the scale on the gauge lets say its R-22. The 22 scale represents temp. Outer is P.S.I. If its 90 degrees outside, look on the inner R-22 scale, temp, and when it gets to 90, add another 27degrees to that which would be 117degrees on the scale and the head pressure will be right around 250 P.S.I. The charge will be very close give or take a few oz's. This is not a critical charge unit. Rule of thumb, when in doubt, add 27 to 30 degrees to the outdoor ambient temperature and you will be very close to the proper charge. Again, look on the data plate as it will be on there the amount of freon it holds. Please keep me posted if you need my help.
Shastalaker7

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Looking for freon capacity for 5 ton goodman package unit, cannot read serial or model number.. unit is 1998-2000 model ,, we just replaced the accumulator and we are not sure how much freon to put in.. Goodman offers no help whatsoever.


Check low side which is the bigger of the two, make sure you tighten the hose good. your reading should be 65 psig.If not add refrigerant/r22 . if r410a 110 to 115. ... Goodman GPC1342H21A Air Conditioner

Central air only blows a small amount of cool air out the vents. After running 12 hours it only cooled my small 1BR apartment 3 degrees. The filter has not been replaced since October 2009 but I can't seem to get it out of it's little slot at the bottom of the unit. It's a Goodman Manufacturing Model Number ARUF024-00-1A. The air filter is loose but won't slide over the bottom metal lip. Is it okay to (a little aggressively) wiggle it out? Thank you so much!


I have a Goodman A/C unit APRF036-00B1. The out side unit seems to be sucking and bowing air, the coil is cool to the the touch and the blower seems to be turning. I've check what seems to be the obvious. A small amount of air is only coming out. Any ... Goodman CKL36AR36 Air Conditioner

We have a Coleman roof unit a/c on our RV. We are going to be replacing it and we're not sure what the btu's are. We are thinking 13,500. The model no. is 6759-707. Can anyone tell us what the btu's are and can we replace that with a 15,000 btu unit? I'm not sure what actual model it is. Coleman Mach 15 a/c was the only category available in order to submit this question. Thanks!


\015\012COLEMAN R.V. PRODUCTS\015\012GO TO rvcomfort.com\015\012Click on RVP (RV PRODUCTS) \015\012Click on type of AC, if you can’t find the information you want there,\015\012then click on contact us on the Green ... Coleman Mach 15 Air Conditioner

Evaporator Coil I have a Goodman A/C system (2 systems...1 for 1st floor, 1 for 2nd floor). The one for downstairs is 3.5 ton. the one for 2nd floor is 3 ton unit. Installed when house was built 5 1/2 years ago. The upstairs unit has had the evap coil replaced once, and repaired a leak once - 6 months ago. The downstairs unit has had the evap coil replaced twice -and is now leaking again. Model for the air handler is ARUF042-00A-1A. Goodman part# for the coil is P140142. Can I replace this coil


Yes, just count how many pins per inch and replace with the same number of pins per inch. ... Air Conditioners

A/C Model: FAC107P1A My unit is not putting out cold air. The temp wire is not touching the coils. I've cleaned the filter, and behind it. What do you think the problem is? What needs to be done to fix the problem? Could it need Freon? What type of Freon does it take? I have a certified person to put it in, but I have to get the Freon myself. Is it a sealed unit? Will it be obvious to him, where to put in the Freon? He said that he's not sure, but hasn't looked at my unit yet. I have to g


Hello, if the filter, evap, coil, condenser coil are clean then most likely the unit if low on freon. most window units take either r 134a or r -22, it will say on the data plate on the unit. To charge freon into the unit a piercing valve will need t ... Frigidaire FAC107P1A Wall/Window Air Conditioner

I have a Trane XE 1100 outdoor unit. I had to refill the freon gas 3-4 times in 3 years. The technician mentioned that I need to replace the outdoor unit. last night, the outside unit was running and the unit in the attic was running and the copper pipe was cold and wet, HOWEVER no air was coming out of the vents all over the house. Do you have an idea WHAT IS THE PROBLEM ? My question: Do you have an idea How much it costs to replace the outside unit ?


... Air Conditioners

Can a Goodman AC unit with a model number of a 24BTU-2 ton unit be upgraded to a 3 ton unit by changing the piston and the settings on the blower? They are also going to install a 3 ton compressor outside. Would this provide the same cooling capacity and performance of changing the actural HVAC unit to a 3 ton unit and would Goodman give me directions stating as much?


They would need to change the coil indoors to a 3 ton. If the blower speed can be increased it should be fine. ... Air Conditioners

Our Goodman inside unit has an accumulation of ice on the Larger of the two lines from the outside unit. A thermometer in the grill in the ceiling indicates that the temp at the grill is 76.4 F even with the thermostat set at 73 F. The red light on the Control in the inside unit is illuminated and the outside unit is on. When placing your hand on the freon lines near the air handler, the freon seems to be pulsing. By that I mean that you can feel the pulsing thru the insulation of the large


It could be that the unit is to small and the compressor does not cycle on and off Try turning it off for a 1/2 hour then turn it on again and then check the air temp of the air coming out. If that does not work it might be low on freon. ... Air Conditioners

I have the opportunity to purchase a Mitsubishi Mr Slim a/c unit that is 3-4 years old. It has been unhooked with the lines and freon removed. I was told that the copper pipes will need to be replaced because of possible dust contamination. How much freon needs to be placed back in to the unit? It is a single unit with 22,000 btu's


It will be posted on the unit as factory charge. ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

My goodman central air unit quit working after a storm. The circuit breaker is not blown. The furnace fan kicks on when ac is turned on at the thermostat but unit outside does not operate. Is there an internal fuse or capacitor on outside unit. Thank you very much, Bryan Model CKL36-IF Goodman


1 posible cause.the thermostat supplies 24 volts to the outside unit to control the contactor if you hear a ligth huming on the outside unit this is the being activated. if this is the case then\015\012\015\012 check to see if any ants are in ... Goodman Air Conditioners

Model ck42-1a compressor won't come on. I replaced the intake filter about a month ago. It was a pleated filter and was real caked when I replaced this month. Can that cause the compressor to go out? I have two units and the pipe coming in to the house is cold on the good unit but not on the bad. Could that be anything but the compressor? Low freon or a-coil freezing in the house?


The fact the filter was very dirty and the door partly open allowing non filtered air to enter the system leads me to a possible dirty evaporative coil on the furnace. That can cause poor airflow and iced up coil reducing airflow even more. In the lo ... Goodman CKL42AR42 Air Conditioner

Replacement Remote I can't find a replacement remote for my Turbo Air Conditioner - Room Air-Conditioner. (Info on Wall Unit - Model of indoor unit TAS-9H, Serial # A09HI02196, Bar Code # C2G5101320) (On the back of the remote - ZHF/LW-15, Rated Voltage 3V.DC) I live in Phoenix, AZ if you can tell me some place local I can get one or order one online. Thanks so much, Robert McDonald


EMAIL: [email protected] for parts / remote controls ... Turboair Air Conditioners

I have a Goodman Model number AR24-1 unit and the blower moter will not start with it turned on to fan or cool or heat. I have checked the thermostat and the unit runs outside. Just no blower. Can I jump the blower motor as I replaced the capacitor today. Hear are some numbers that may help. Part Number #15212-50 Volt 208/240 Amp 1.5 HP 1/5 No heat Kit It has a Goodman switch board # B1370735 that I can check with my meter if needed. I have checked the thermostat in the attic also. Seems like


... Air Conditioners

I have a Goodman Air Conditioner Model CK49-1B. The fan in the unit does not turn on when the thermostate is set for cooling; the fan in the furnace works and blows warm air. Checking outside I discover that the dog chewed three wires that are coming from the unit. The repair person told me that the dog shortout the CONTACTOR and had to be replaced it, he also replaced 12 inches of wires damaged by the dog.. He did the job in less than one hour and charged me $225.00. Did he over charge me? Late


Take a look on amazon for same parts, and compare the prices: Amazon com goodman air conditioner parts. I hope this was helpful. Cheers ... Goodman CLQ36AR49 Air Conditioner

I am working on a GE air conditioner Model # AZ35H15D5BMI, Serial # TA659138, manufactured date 10/01, I replace the control board part number WP26X10018 and the board fried a resistor or a diod. I have purchased a new control board and don't want to burn this board. I need a schematic of the unit to make sure I rewire the unit properly. There is no schematic in the unit that I can find, I have slide the unit out and looked in the outside unit for paper work or a diagram but have had no luck


Dear friend i got some model number for you... have a look....please click here and have a look... ... GE Air Conditioners

I have a Goodman Furnace model#GDS80703AXBC.The unit is one year old and ran fine until the gas got shut off accidently outside at the meter.Unit was cycling with no gas for 2 days.we turned the gas back on and the unit is showing one light blinking for over cycle trys.The unit did eventually start up but it does not fire up after each time the thermostat is calling for heat.The unit has been running like this for about 10 days now.I have replaced the Diagnostic computer, glow igniter,flame sens


The only part not replaced so far is the gas valve. Because the gas valve is getting power does not mean it is opening.You could also have gotten trash(corrosion/scale) in the valve orifice and or the burner orifices.Is there a drip ... Goodman Air Conditioners

Hello, my HVAC is constantly freezing, even after freon is added. I was told that I have a leak in the coils and need to chance the air handler - the outside unit is about 10 years old - air handler about 18 years old. I would like to get only the air handler for my R22 outside condensing unit. My question is if in the future can I use this same 3.5 ton air handler with a new 410 condensing unit once my outside unit needs to be replaced. In other words can a Goodman air handler be used firs


I'm new at this and I can't tell how old the post is but I'll contribute anyway.You probably have fixed the problem by now. I wonder what part of the system is freezing up. I don't have a lot of experience but I know you can get frost where there ... Goodman CKL42AR42 Air Conditioner

I have a whirpool window a/c and heat unit. The model number is ACE184XL0. The unit is 8 years old. It no longer cools the air like it use to. The unit heats well. Do I have realistic repair alternatives? I have been told the window units have no easy way to re-charge the freon and it is cheaper to replace it.


Try cleaning the air filter on the unit. ... Whirlpool Air Conditioners

59516.606c1. We have a 1999 hitchhiker 2. The a/c unit will not turn off even when you turn the controller to the off position. We are looking to replace the entire unit but we're not for sure what kind it is. Where do I look to find the unit model and make.


... Dometic Rooftop RV Air Conditioner

Fan won't turn on outside unit but has a hum noise to the unit -replaced fan motor but did not help at all. The unit is a Goodman Model #CK-361A


Sounds like a capcitor is bad they cost around 10 to 30 bucks ... Air Conditioners

I have a goodman gsc13 ac unit about 4 year old. When the temp gets around 90 or above outside the fan on the unit starts but the compressor does not. I had service check it out but that day they were here it was in the 80's and it worked fine. I replace the thermostat to make sure that wasn't the problem. Interesting if I turn the unit off at the thermostat and wait 15 minutes and turn it back on it will run fine. But the next time it tries to turn on automaitcally it will just be the fan o


The hum you hear is the 24v transformer which is powered form the air handler inside have you tried a hard start kit or had cap checked ... Air Conditioners

The motor or blower wheel om my Goodman model GMP 100-4 unit whistles and sticks. How can I fix this? Can the motor or blower wheel be lubricated? Does the motor need to be replaced. If I manualy spin the blower wheel and get it turming some what and then start the unit by pressing the safty switch located behind the lower front panel the blower will start, the wheel fan will turn. If I turn the unit off and try to turn it on again before the wheel stops turning the blower will work. But, if


Yes its the motor problem.the noise is from motor.as the blower wheel is not making noise when car is turned off.and when checked manually the blower wheel is not making noise.that means motor is faulty\015\012thanks.please do rate the solution ... Air Conditioners

I have a Goodman CKJ60-1c. A technician just replaced the cap due to the breaker tripping (he said cap was causing high amps). Once cap was replaced, now fan is running backwards. i checked wiring - everything seems wired according to schematic (no assist start installed). He says fan motor is bad and needs replaced. Never heard of a motor running backwards - aside from a wiring issue. Not sure if cap he installed is proper for unit. Cap is MARS 80 5 uf+-6% 440vac, 12297. Any advice?


... Goodman Air Conditioners

Need goodman outside unit only to replace model cpke30-18


... Goodman CKL42AR42 Air Conditioner

I have a Goodman (AR24-1) unit, the heating is electric not gas. How do I test the blower motor with out removing it. I have a part number but not sure if it is the blower motor number or not. Part number 15212-50. (1.5 AMP 1/5 HP) 208/204 Volts) I have replaced the capacitor today but still did not start when I have the Fan switch turned on. I have checked the thermostat. Any way to check the motor? The switch board number is ( # Goodman B1370735) I can test it with my meter if needed.


... Goodman CKL24AR24 Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific